TABLE OF CONTENTS Safety Rules 2-4 Know Your Generator 5 Assembly 6-7 Operation 8-14 Maintenance 15-16 Storage 16 Troubleshooting 17 Schematic/Wiring Diagram 18-19 Replacement Parts 20-23 Notes 24 Warranty 25 EQUIPMENT

SAFETY RULES

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

DESCRIPTION

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by the engine. This generator incorporates GFCI (Ground Fault Circuit Interrupter) outlet protection and has its neutral bonded to ground to pass OSHA inspections on job sites.This generator will not function when connected to a transfer switch since the home or building main breaker box also has a neutral bonded to ground.When both the generator and the home or building breaker box contains a neutral bonded to ground, the generators GFCI will open and no outlets will function.

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Hazard Symbols and Meanings

Electrical Shock Electrocution Electrical Shock

Fire Explosion Toxic Fumes

DO NOT remove the neutral bond.

  • Removing the neutral bond could result in death, bodily injury and/or property damage.

Explosive Pressure Chemical Burn

Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.

Hot Surface

Page 3 of the Briggs & Stratton PRO8000 user manual — DANGER
Page 3 · cliquer pour agrandir
Page 3

DANGER

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

  • Operate generator ONLY outdoors.
  • WHEN ADDING OR DRAINING FUEL
  • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
  • Fill or drain fuel tank outdoors.
  • DO NOT overfill tank.Allow space for fuel expansion.
  • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • DO NOT light a cigarette or smoke. WHEN STARTING EQUIPMENT
  • Ensure spark plug, muffler, fuel cap and air cleaner are in place.
  • DO NOT crank engine with spark plug removed.
  • If fuel spills, wait until it evaporates before starting engine. WHEN OPERATING EQUIPMENT
  • Do not tip engine or equipment at angle which causes fuel to spill.
  • This generator is not for use in mobile equipment or marine applications. WHEN TRANSPORTING OR REPAIRING EQUIPMENT
  • Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
  • Disconnect spark plug wire. WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
  • Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.
  • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

DANGER

Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

  • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
  • Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.
  • DO NOT touch bare wires or receptacles.
  • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • DO NOT operate generator in the rain.
  • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • DO NOT allow unqualified persons or children to operate or service generator.
DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. • DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. • Wear protective goggles, rubber apron, and rubber gloves.
Briggs & Stratton PRO8000 — DANGER diagram (page 3)
Fig. 3
  • This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.
  • Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.
Page 4 of the Briggs & Stratton PRO8000 user manual — DANGER
Page 4 · cliquer pour agrandir
Page 4

Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load.

Unintentional sparking can result in fire or electric shock.

  • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.
  • DO NOT modify generator in any way.
  • WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

  • See “Don’t Overload Generator”.
  • Start generator and let engine stabilize before connecting electrical loads.
  • Connect electrical loads in OFF position, then turn ON for operation.
  • Turn electrical loads OFF and disconnect from generator before stopping generator.

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.

  • DO NOT touch hot surfaces.
  • Allow equipment to cool before touching.
  • Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.
  • In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

Improper treatment of generator can damage it and shorten its life.

  • Use generator only for intended uses.
  • If you have questions about intended use, ask dealer or call 1-800-743-4115.
  • Operate generator only on level surfaces.
  • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
  • DO NOT insert any objects through cooling slots.
  • If connected devices overheat, turn them off and disconnect them from generator.
  • Shut off generator if: -electrical output is lost; -equipment sparks, smokes, or emits flames; -unit vibrates excessively.
Page 5 of the Briggs & Stratton PRO8000 user manual — KNOW YOUR GENERATOR
Page 5 · cliquer pour agrandir
Page 5
Briggs & Stratton PRO8000 — KNOW YOUR GENERATOR diagram (page 5)
Fig. 4

KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

12 Volt DC Receptacle

120 Volt AC, 20 Amp Duplex Receptacles

120 Volt AC, 30 Amp Locking Receptacle

Circuit Breakers (AC) 120/240 Volt AC, 30 Amp Locking Receptacle

12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery.

Data Tag – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.

120 Volt AC, 20 Amp Duplex Receptacles — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Fuel Tank — Capacity of seven (7) U.S. gallons. GFCI Circuit Breaker — A GFCI circuit breaker is provided to protect against electrical ground fault and protect the generator against electrical overload.

120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Grounding Fastener — If required, please consult a qualified electrician, electrical inspector, or local agency having jurisdiction.

120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Hour Meter — Displays and records how many hours your generator has run (up to 9,999.9).

Idle Control Switch — The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.

Air Cleaner — Uses a dry type filter element and foam pre–cleaner to limit the amount of dirt and dust sucked into the engine. Choke Lever — Used when starting a cold engine.

Ignition Switch — Push to start and stop the engine.

Oil Fill Cap — Add oil to engine here. Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.

Circuit Breakers (AC) — Push to reset circuit breakers are provided to protect the generator against electrical overload.

Show 11 more labels / short text on this page
Oil Fill Cap · Air Cleaner · Fuel Tank · Hour Meter · Idle Control Switch · Ignition Switch · Choke Lever · Data Tag · Spark Arrester Muffler · Grounding Fastener · GFCI Circuit Breaker
Page 6 of the Briggs & Stratton PRO8000 user manual — Carton Contents
Page 6 · cliquer pour agrandir
Page 6
Briggs & Stratton PRO8000 — ASSEMBLY diagram (page 6)
Fig. 5

ASSEMBLY

ELECTRIC START

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.

Your unit is equipped with electric start capability but can be started manually. If you choose not to use the electric start feature, you do not need to install the battery.

If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115.

Check Battery / Attach Negative

Battery Wire

The sealed battery on the generator is fully charged and pre–installed except for the negative (black) battery cable.

Remove Generator From Carton

1. Set the carton on a rigid flat surface with "This Side Up" arrows pointing upward.

To install: 1. Cut off tie wrap securing loose end of negative (black) cable.

2. Carefully open the top flaps of the shipping carton.
3. Cut down corners at one end of carton from top to bottom and lay that side of carton down flat.
2. Remove nut and washer on negative battery terminal.
3. Slide negative battery cable over screw on negative terminal (Figure 1).
4. Remove all packing material, carton fillers, etc.
5. Remove the generator from the shipping carton.

Figure 1 — Negative Battery Connection

Carton Contents

Check all contents against those listed below:

  • Main unit
  • Engine oil
  • Owner’s manual
  • Engine manual
  • Battery charge cables
  • Battery charger
  • Locking 120/240V, 30A plug
  • Locking 120V, 30A plug
  • Wheel kit
4. Reattach washer and nut and tighten.

If any parts are missing or damaged, call the generator helpline at 1-800-743-4115.

5. Verify that connections to battery and generator are tight and secure.
Show 5 more labels / short text on this page
Nut · Washer · Screw · Negative battery cable · Positive battery cable
Page 7 of the Briggs & Stratton PRO8000 user manual — TANK
Page 7 · cliquer pour agrandir
Page 7

BEFORE STARTING THE

Add Fuel

ENGINE

Add Engine Oil

  • Place generator on a level surface.

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

  • Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure. WHEN ADDING FUEL
  • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
  • Fill fuel tank outdoors.
  • DO NOT overfill tank.Allow space for fuel expansion.
  • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • DO NOT light a cigarette or smoke.
  • Refer to engine manual for oil fill information.
  • Damage to equipment resulting from failure to follow this instruction will void warranty.
  • Refer to engine owner’s manual and follow oil recommendations and instructions.
1. Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful not to fill above the baffle.This allows adequate space for fuel expansion (Figure 2).

Figure 2 — Typical Fuel Expansion Space

TANK

FUEL

4. Install fuel cap and wipe up any spilled fuel.

Baffle

Page 8 of the Briggs & Stratton PRO8000 user manual — Starting the Engine
Page 8 · cliquer pour agrandir
Page 8
Briggs & Stratton PRO8000 — USING THE GENERATOR diagram (page 8)
Fig. 6

USING THE GENERATOR

OPERATING THE

GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

  • See “Don’t Overload Generator”.
  • Start generator and let engine stabilize before connecting electrical loads.
  • Connect electrical loads in OFF position, then turn ON for operation.
  • Turn electrical loads OFF and disconnect from generator before stopping generator.

Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

DANGER

  • In some areas, generators are required to be registered with local utility companies.

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

  • If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical

  • Operate generator ONLY outdoors.

System

  • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

Starting the Engine

DANGER

Disconnect all electrical loads from the generator. Use the following start instruction steps in numerical order:

Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

1. Make sure unit is on a level surface.
  • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
  • Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.
  • DO NOT touch bare wires or receptacles.
  • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • DO NOT operate generator in the rain.
  • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • DO NOT allow unqualified persons or children to operate or service generator.
2. Turn fuel valve to “ On ” position (Figure 3).

Figure 3 — Fuel Shut-off Valve

Page 9 of the Briggs & Stratton PRO8000 user manual — Operating Automatic Idle Control
Page 9 · cliquer pour agrandir
Page 9
3. Make sure Idle Control switch is in “ Off ” position (Figure 4).
  • Connecting Electrical Loads
  • Let engine stabilize and warm up for a few minutes after starting.
  • Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.
  • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.
  • DO NOT connect 3–phase loads to the generator.
  • DO NOT connect 50 Hz loads to the generator.
  • DO NOT OVERLOAD THE GENERATOR . See “Don’t Overload Generator”.

Figure 4 — Idle Control Switch

4. Follow start instructions given in engine owner’s manual. Push and hold the Ignition switch in “ Start ” position (Figure 5) until generator starts.To prolong the life of starter components, DO NOT hold Ignition switch in “ Start ” position for more than 15 seconds, and pause for 1 minute.

Stopping the Engine 1. Turn OFF and unplug ALL electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Move idle control switch to “Off” position. 3. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. 4. Move fuel valve to “Off” position. 5. Set Ignition switch in “Stop” position.

Figure 5 — Ignition Switch

Operating Automatic Idle Control

This switch is designed to greatly improve fuel economy. When this switch is turned ON, the engine will only run at its normal high governed engine speed when electrical loads are connected.When an electrical load is removed, the engine will run at a reduced speed.

With the switch off, the engine will run at the normal high engine speed. Always have the switch off when starting and stopping the engine.

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.

  • DO NOT touch hot surfaces.
  • Allow equipment to cool before touching.
  • Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.
  • In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.
Page 10 of the Briggs & Stratton PRO8000 user manual — How to Use the Battery Charger
Page 10 · cliquer pour agrandir
Page 10

Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6 Volt batteries. DO NOT use the unit to crank an engine having a discharged battery.

7. Connect battery charge cable clamp with black handle to the negative (–) battery terminal (Figure 6).
8. Start engine. Let engine run while battery recharges.
9. When battery has charged, shut down engine
DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. • DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. • Wear protective goggles, rubber apron, and rubber gloves.

How to Use the Battery Charger

Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage.

1. Plug charger into unit’s “Battery Float Charger” jack, which is located on the control panel (Figure 7). Plug battery charger into a 120 Volt AC wall receptacle.
Briggs & Stratton PRO8000 — How to Use the Battery Charger diagram (page 10)
Fig. 7 · How to Use the Battery Charger

To recharge 12 Volt batteries, proceed as follows: 1. Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. DO NOT use tap water.

2. If battery is equipped with vent caps, make sure they are installed and are tight.
3. If necessary, clean battery terminals.
2. Unplug charger from unit and wall outlet when generator is being started and while in operation.
4. Connect battery charge cable connector plug to panel receptacle identified by the words “12-VOLTS D.C.”.
3. Keep charger plugged in when generator is not in use to prolong battery life.The charger has a built in float equalizer and will not overcharge battery, even when plugged in for an extended period of time. IMPORTANT: See “Battery Maintenance” on page 16 for additional information. Figure 6 — Battery Connections
5. Move idle control switch to “ Off ” position.
6. Connect battery charge cable clamp with red handle to the positive (+) battery terminal (Figure 6).
Briggs & Stratton PRO8000 — How to Use the Battery Charger diagram (page 10)
Fig. 8 · How to Use the Battery Charger
Page 11 of the Briggs & Stratton PRO8000 user manual — NEMA L14-30 Ground (Green)
Page 11 · cliquer pour agrandir
Page 11

COLD WEATHER

RECEPTACLES

OPERATION Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your generator may experience icing of the carburetor and/or the crankcase breather system. Build a structure that will enclose three sides and the top of the generator: 1. Make sure entire muffler-side of generator is exposed. Note that your generator may appear different from that shown in Figure 8.

Briggs & Stratton PRO8000 — COLD WEATHER diagram (page 11)
Fig. 9

Receptacles may be marked with rating value greater than generator output capacity.

  • NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.
  • DO NOT overload the generator. See “Don’t Overload Generator”.

120/240 Volt AC, 30 Amp, Locking Receptacle

Figure 8 — Permanent Cold Weather Shelter

Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volts AC at 30 Amps (or greater) (Figure 9).You can use the same 4–wire cord if you plan to run a 120 Volt load.

Figure 9 — 120/240 Volt AC, 30 Amp Receptacle

120V 120V W (Neutral)

2. Ensure a minimum of two feet clearance between open side of box and nearest object. 3. Face exposed end away from wind and elements. 4. Enclosure should hold enough heat created by generator to prevent problems.

X (Hot) Y (Hot)

DANGER

NEMA L14-30 Ground (Green)

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts of power at 30 Amps for 120 Volts; 7,200 watts of power (7.2 kW) at 30 Amps for 240 Volts.The outlet is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.

  • Operate generator ONLY outdoors.
  • Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.
  • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
  • Remove generator from shelter when temperature is above 40°F [4°C].

Wind · 4-Wire Cord Set

Page 12 of the Briggs & Stratton PRO8000 user manual — 120 Volt AC, 20 Amp, Duplex Receptacle
Page 12 · cliquer pour agrandir
Page 12

120 Volt AC, 30 Amp Locking Receptacle

Figure 11 — 120 Volt AC, 20 Amp, Duplex Receptacle

Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire cord set rated for 125 Volts AC at 30 Amps to the plug (Figure 10).

Figure 10 — 120 Volt AC, 30 Amp, Locking Receptacle

NEMA L5-30

Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).

12 Volt DC, 10 Amp Receptacle

This receptacle (Figure 12) allows you to recharge a 12 Volt automotive or utility style storage battery.

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.6 kW) of power at 30 Amps.The outlet is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.

Figure 12 — 12 Volt DC, 10 Amp Receptacle

120 Volt AC, 20 Amp, Duplex Receptacle

Each duplex receptacle (Figure 11) is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.

This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See “Charging a Battery” on page 10 before attempting to recharge a battery.This outlet is protected by a 10 Amp self resetting circuit breaker.

Show 4 more labels / short text on this page
3-Wire Cord Set · Neutral · Hot · Ground (Green)
Page 13 of the Briggs & Stratton PRO8000 user manual — DANGER
Page 13 · cliquer pour agrandir
Page 13

Ground Fault Protection This unit is equipped with a Ground Fault Circuit Interrupter (GFCI).This device meets applicable federal, state and local codes. The GFCI protects against electrical shock that may be caused if your body becomes a path which electricity travels to reach ground.This could happen if you touch a “Live” appliance or wire, or are touching plumbing or other materials that connect to the ground. When protected by a GFCI, one may still feel a shock, but the GFCI should cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury.

2. If handle moves to center, reset circuit breaker by firmly moving handle to “ Off ” (down) position, then to “ On ” (up) position.

If circuit breaker does not reset properly:

  • DO NOT use generator.
  • Call a Briggs & Stratton Power Products service center.

During Generator Use If circuit breaker trips during use, it usually indicates faulty electrical equipment or cords. However, test the circuit breaker as follows;

DANGER

1. Disconnect loads, reset and test circuit breaker as described earlier. Let generator run without any loads for 1 minute.

Generator produces powerful voltage.

  • The GFCI will not protect you against the following situations: -Line-to-line shocks; -Current overloads or line-to-line short circuits.
  • The fuse or circuit breaker at the control panel must provide such protection.

If circuit breaker trips in the 1 minute period:

  • DO NOT use generator.
  • Call a Briggs & Stratton Power Products service center.
2. If circuit breaker tests correctly, the electrical equipment or extension cords may be faulty. Replace faulty electrical equipment and cords before further use.

Test GFCI Circuit Breaker Test your GFCI circuit breaker (Figure 13) every month, as follows:

Figure 13 — GFCI Circuit Breaker

If circuit breaker tests correctly:

  • Have qualified personnel check all electrical equipment and cords for any defects.
  • Replace electrical equipment and cords or take to a qualified repair center.

DANGER

Generator produces powerful voltage.

1. While generator is running, push white “ Test ” button. The circuit breaker should trip (handle will move to approximate center position), which will disconnect power to outlets.
  • DO NOT touch bare wires or receptacles.
  • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • DO NOT operate generator in the rain.
  • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • DO NOT allow unqualified persons or children to operate or service generator or electrical loads.

If circuit breaker does not trip:

  • DO NOT use generator.
  • Call a Briggs & Stratton Power Products service center.
Page 14 of the Briggs & Stratton PRO8000 user manual — Example:
Page 14 · cliquer pour agrandir
Page 14

DON'T OVERLOAD

4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, as described above.

GENERATOR

Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items.This is the amount of power your generator must produce to keep your items running. See Figure 14. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Figure 14 - Wattage Reference Chart

Watts Essentials Light Bulb - 75 watt 75 - Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator/Freezer - 18 Cu. Ft. 800 1600 Water Well Pump - 1/3 HP 1000 2000 Heating/Cooling Window AC - 10,000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower - 1/2 HP 800 1300 Kitchen Microwave Oven - 1000 Watt 1000 - Coffee Maker 1500 - Electric Stove - Single Element 1500 - Hot Plate 2500 - Family Room DVD/CD Player 100 - VCR 100 - Stereo Receiver 450 - Color Television - 27” 500 - Personal Computer w/17” monitor 800 - Other Security System 180 - AM/FM Clock Radio 300 - Garage Door Opener - 1/2 HP 480 520 Electric Water Heater - 40 Gallon 4000 - DIY/Job Site Quartz Halogen Work Light 1000 - Airless Sprayer - 1/3 HP 600 1200 Reciprocating Saw 960 960 Electric Drill - 1/2 HP 1000 1000 Circular Saw - 7 1/4” 1500 1500 Miter Saw - 10” 1800 1800 Table Planer - 6” 1800 1800 Table Saw/Radial Arm Saw - 10” 2000 2000 Air Compressor - 1-1/2 HP 2500 2500

Example:

Tool or Appliance Rated (Running)

(Starting) Watts Window Air Conditioner

Refrigerator 800 1600 Deep Freezer 500 500 Television 500 - Light (75 Watts) 75 - 3075 Total Running Watts

1800 Highest Surge Watts

Total Rated (Running) Watts = 3075 Highest Additional Surge Watts = 1800 Total Generator Output Required = 4875

Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator.There should be nothing connected to the generator outlets before starting it's engine.The correct and safe way to manage generator power is to sequentially add loads as follows: 1. With nothing connected to the generator, start the engine as described in this manual. 2. Plug in and turn on the first load, preferably the largest load you have. 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).

*Wattages listed are approximate only. Check tool or appliance for actual wattage.

Show 8 more labels / short text on this page
Additional · Rated* (Running) · Surge (Starting) · Tool or Appliance · Watts · Additional Surge · Watts · 1200 1800
Page 15 of the Briggs & Stratton PRO8000 user manual — Generator Maintenance
Page 15 · cliquer pour agrandir
Page 15
Briggs & Stratton PRO8000 — RECOMMENDATIONS diagram (page 15)
Fig. 10

SPECIFICATIONS Maximum Surge Watts 10,000 Watts Continuous Wattage Capacity 8,000 Watts Power Factor 1.0 Rated Maximum Continuous Load Current

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

At 120 Volts 66.6 Amps At 240 Volts 33.3 Amps Phase 1-phase Rated Frequency 60 Hertz Fuel Tank Capacity 7 U.S. gallons Shipping Weight 270 lbs. GENERAL MAINTENANCE

Briggs & Stratton PRO8000 — RECOMMENDATIONS diagram (page 15)
Fig. 11

Unintentional sparking can result in fire or electric shock.

  • WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a damaged or defective generator.

Fuel Valve Maintenance

Engine Maintenance

The fuel valve is equipped with a fuel sediment cup, screen, retaining ring and o-ring that need to be cleaned every 6 months or 100 hours (whichever occurs first).

See engine owner’s manual for instructions.

Briggs & Stratton PRO8000 — Fuel Valve Maintenance diagram (page 15)
Fig. 12 · Fuel Valve Maintenance
1. Move fuel valve to “ Off ” position. 2. Remove sediment cup from fuel valve. Remove o-ring, retaining ring and screen from fuel valve (Figure 15).

Avoid prolonged or repeated skin contact with used motor oil.

Briggs & Stratton PRO8000 — Fuel Valve Maintenance diagram (page 15)
Fig. 13 · Fuel Valve Maintenance
  • Used motor oil has been shown to cause skin cancer in certain laboratory animals.
  • Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

3. Wash sediment cup, o-ring, retaining ring, and screen in a nonflammable solvent. Dry them thoroughly.
Page 16 of the Briggs & Stratton PRO8000 user manual — Other Storage Tips
Page 16 · cliquer pour agrandir
Page 16
4. Place screen, retaining ring, and o-ring into fuel valve. Install sediment cup and tighten securely. 5. Move fuel valve to “ On ” position, and check for leaks. Replace o-ring if there is any leakage.

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.

Generator Storage

  • Clean the generator as outlined in “Generator Cleaning”.
  • Check that cooling air slots and openings on generator are open and unobstructed.

Generator Cleaning • Use a damp cloth to wipe exterior surfaces clean.

Storage covers can be flammable.

Improper treatment of generator can damage it and shorten its life.

  • DO NOT place a storage cover over a hot generator.
  • Let equipment cool for a sufficient time before placing the cover on the equipment.
  • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
  • DO NOT insert any objects through cooling slots.

Engine Storage

See engine owner’s manual for instructions.

  • Use a soft bristle brush to loosen caked on dirt or oil.
  • Use a vacuum cleaner to pick up loose dirt and debris.
  • Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

Other Storage Tips

  • To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor. The unit and fuel can then be stored for up to 24 months. Fuel stabilizer can be purchased locally.
  • DO NOT store fuel from one season to another unless it has been treated as described above.
  • Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.
  • Store unit in a clean and dry area.
Page 17 of the Briggs & Stratton PRO8000 user manual — Problem Cause Correction
Page 17 · cliquer pour agrandir
Page 17
Briggs & Stratton PRO8000 — TROUBLESHOOTING diagram (page 17)
Fig. 14

TROUBLESHOOTING

Problem Cause Correction

1. One of the circuit breakers is open.
1. Reset circuit breaker.
2. Fault in generator.
2. Contact Authorized service facility.

No AC output is available, but generator is running.

3. Poor connection or defective cord set.
3. Check and repair.
4. Connected device is bad.
4. Connect another device that is in good condition.
1. Short circuit in a connected load.
1. Disconnect shorted electrical load.

Generator runs good at no-load but "bogs" down" when loads are connected.

2. Generator is overloaded.
2. See "Don't Overload Generator".
3. Shorted generator circuit.
3. Contact Authorized service facility.
1. Failed battery.
1. Replace battery.

Generator will not start; or starts and runs rough.

2. Low oil level.
2. Fill crankcase to proper level or place generator on level surface.
1. Out of gasoline.
1. Fill fuel tank.

Generator shuts down during operation.

2. Low oil level.
2. Fill crankcase to proper level or place generator on level surface.

Generator lacks power. Load is too high. See "Don't Overload Generator".

Page 18 of the Briggs & Stratton PRO8000 user manual — SCHEMATIC
Page 18 · cliquer pour agrandir
Page 18
Briggs & Stratton PRO8000 — SCHEMATIC diagram (page 18)
Fig. 15

SCHEMATIC

Briggs & Stratton PRO8000 — SCHEMATIC diagram (page 18)
Fig. 16
Page 19 of the Briggs & Stratton PRO8000 user manual — WIRING DIAGRAM
Page 19 · cliquer pour agrandir
Page 19

WIRING DIAGRAM

Briggs & Stratton PRO8000 — WIRING DIAGRAM diagram (page 19)
Fig. 17
Page 20 of the Briggs & Stratton PRO8000 user manual — UNIT EXPLODED VIEW
Page 20 · cliquer pour agrandir
Page 20
Briggs & Stratton PRO8000 — UNIT EXPLODED VIEW diagram (page 20)
Fig. 18

UNIT EXPLODED VIEW

Briggs & Stratton PRO8000 — UNIT EXPLODED VIEW diagram (page 20)
Fig. 19
Page 21 of the Briggs & Stratton PRO8000 user manual — Parts Not Illustrated
Page 21 · cliquer pour agrandir
Page 21

UNIT PARTS LIST

Item Part # Description 1 B193230GS CRADLE, Gen Black 2 194209GS KIT, Engine Support Hardware 3 56893GS CRIMPTITE, 10-24 x 1/2 4 190220GS ADAPTER, Engine 5 NSP ASSY,Alternator (see page 22) 6 194151GS KIT,Adapter Mounting Hardware 7 62265GS GROMMET 8 96796GS WASHER 9 194208GS KIT,Alt to Heat Shield Hardware 10 190274BGS SCREW, SBHC, 3/8-16 x 1" 11 25254GS HHCS 5/16-24 x 9-7/8 12 189302BGS ASSY,Wire 13 * HHCS, M8 - 1.25 x 16 14 * WASHER, Shakeproof, Ext. 5/16 15 * WASHER, Shakeproof, Ext. M6 16 B77304GS SUPPORT, Engine 17 75246GS TAPTITE, 3/8 - 16 x 1-1/4 18 96867GS ASSY, Stepper Motor 19 J93074GS SUPPORT, Heatshield 20 B4986GS DECAL, Ground 21 194155GS KIT,Vibration Mount 22 194542GS KIT, Stepper Motor Hardware 23 193646GS KIT, Grounding Hardware 24 194950GS ASSY, Heat Shield 26 74908GS TAPTITE, M5 - 0.8 x 10 30 194543GS KIT,Throttle Linkage Hardware 31 191436GS DECAL, Caution Hot Muffler 33 194211GS KIT, Starter Contact Hardware 34 186347GS COVER, RBC Plastic 35 194214GS KIT, Hose, Fuel 36 194210GS KIT, Starter Mounting Hardware 37 * SCREW, Self Driller, 12-14 x 7/8 38 192376GS SCREW, 12 - 24 x 1/2 Thd Forming 40 194212GS KIT, Fuel Tank Hardware 41 193272GS VALVE, Fuel 43 B4769GS CONTACTOR, Starter 44 193299GS ASSY,Tank Fuel (Includes Items 41,

Item Part # Description 51 194799GS DECAL, Danger 52 93826GS DECAL, Operating Instructions 53 194034GS KIT, Folddown Handle Hardware 55 191435GS DECAL, Fuel Shutoff 56 95349GS PLATE,Adjust 57 189759GS KIT, Fuel Valve Repair 58 194949GS ASSY, Control Panel (see page 23) 59 * WASHER, M6 - 1/4, Int. Shakeproof 60 J193512GS SUPPORT,Tray Battery 61 95348GS BRACKET, Bell Crank 62 95921GS LINKAGE, Bell Crank to Throttle 63 96717GS SPRING 68 J192985GS TRAY, Battery 69 B4489GS BATTERY 70 * HHCS, M6 -1.0 x 12 74 193347GS KIT, Hardware Battery 76 185939GGS ASSY,Wire 78 189302EGS ASSY,Wire 83 192403YGS ASSY,Wire 85 B193200GS ASSY, Fold Down Handle (Includes

Item 86) 86 189718GS GRIP, Handle 900 NSP ENGINE

Parts Not Illustrated

194947GS MANUAL, Owner's MS5375 MANUAL, Engine BB3061GS BOTTLE, Oil B4177GS CHARGER, Battery 65787GS CABLES, Battery Charge 193662GS KIT, Decal Service 43438GS PLUG, 120/240V, 30A 4P 37806GS PLUG, 125V, 30A 3P 193454GS SHEET, Instruction,Wheel Kit 690661 SCREW,Tapping Hex 392390 ARRESTER, Spark 692099 ASSY, Muffler 691513 BRACKET, Muffler 692056 SCREW 690898 CLAMP, Muffler 692539 SCREW

51, 52 & 57) 45 189135GS CAP,Tank Fuel 46 B4135GS PIN, Handle Release 47 77395GS NUT, Lock, M6 48 14353621GS WIRE, Ground 49 95920GS LINKAGE, Stepper Motor to Bell

* - Items without part numbers are common fasteners and are available at local hardware stores.

Crank

Page 22 of the Briggs & Stratton PRO8000 user manual — ALTERNATOR EXPLODED VIEW AND PARTS LIST
Page 22 · cliquer pour agrandir
Page 22

ALTERNATOR EXPLODED VIEW AND PARTS LIST

Briggs & Stratton PRO8000 — ALTERNATOR EXPLODED VIEW AND PARTS LIST diagram (page 22)
Fig. 20

Item Part # Description 1 186059GS ADAPTER, Mounting,Alternator 2 192938GS ROTOR 3 192937AGS STATOR 4 186060GS RBC, with O-Ring (p/n 189197GS) 5 66449LGS HHCS, M6 - 1.0 x 190 SEMS 6 66386GS ASSY, Holder, Rectifier/Brush 7 66849GS TAPTITE, M5 - 0.8 x 16 8 22097GS WASHER, Lock, 1/4 - M6 9 81917GS PIN, Roll, 4mm x 10 10 65795GS RECTIFIER, Battery Charge 11 66849CGS TAPTITE, M5 - 0.8 x 30 12 23762GS WASHER, Shakeproof, Ext. #10 13 189769GS REGULATOR,Voltage-AVR

Page 23 of the Briggs & Stratton PRO8000 user manual — CONTROL PANEL EXPLODED VIEW AND PARTS LIST
Page 23 · cliquer pour agrandir
Page 23

CONTROL PANEL EXPLODED VIEW AND PARTS LIST

Item Part # Description 1 B192834GS PANEL, Control 2 B192837GS BOX, Control Panel 3 * WASHER, Flat, #10 - M5 4 * WASHER, Lock, M5 5 * PPHMS, M5 - 0.8 x 12 6 * WASHER, M6 - 1/4, Int. Shakeproof 7 82538GS SWITCH, Rocker 8 192855GS SWITCH, Rocker 9 77604GS METER, Hour 10 * WASHER, Lock, M3 11 * NUT, M3 - 0.5 12 * PHMS, M3 - 0.5 x 10 13 77314GS THERMAL, Relay 14 87962GS BREAKER, Circuit, 10A, 12V 15 84028GS TRANSFORMER, Idle Cnt 16 64525GS STANDOFF, HEX, 3/4" 17 94117GS PCB, Idle Control, 10KW 18 * PHTS, 6 - 32 x 3/8" 19 92953GS TERMINAL, Block 20 * WASHER, Lock, M4 21 * PPHMS, M4 - 0.7 x 20

Item Part # Description 22 * NUT, M4 - 0.7 23 * WASHER, Flat, M4 24 192931GS BRACKET, GFCI Breaker 25 * WASHER, Shakeproof, Int. #8 26 192828EGS BREAKER, Circuit, GFCI, 40A 27 68868GS OUTLET, 120V, 30A 28 43437GS OUTLET, 120/240V, 30A 29 68759GS OUTLET, 120V, 20A, Duplex 30 194953GS HARNESS,Wire 31 193597GS JUMPER,Terminal Block 32 75207GS BREAKER, Circuit, 20A w/hardware 33 90418GS OUTLET, 12VDC, Snap 34 B4694GS JACK, Coaxial 35 75207NGS BREAKER, Circuit, 35A, w/hardware 36 188632GS BOOT, Rubber Wire Outlet 37 77043BGS CONDUIT, Flex, .50 I.D. x 9.5 38 62265GS GROMMET

* - Items without part numbers are common fasteners and are available at local hardware stores.

Page 24 of the Briggs & Stratton PRO8000 user manual — NOTES
Page 24 · cliquer pour agrandir
Page 24
Briggs & Stratton PRO8000 — NOTES diagram (page 24)
Fig. 21

NOTES

Page 25 of the Briggs & Stratton PRO8000 user manual — BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
Page 25 · cliquer pour agrandir
Page 25

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY

Effective June 1, 2004 replaces all undated Warranties and all Warranties dated before June 1, 2004

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.

OUR EQUIPMENT*

OUTBOARD

PRESSURE

WATER PUMP (Not available in the

PORTABLE GENERATOR

HOME GENERATOR SYSTEM

MOTOR

WASHER

USA)

WELDER Less than 10 KW 10 KW or greater Transfer switch

WARRANTY PERIOD**

3 years or 1500 hours none

* The engine and starting batteries are warranted solely by the manufacturers of those products. ** 2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and Home Generator System - Less than 10 KW, outside of European Union.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty. Equipment used for Prime Power in place of utility are not applicable to this warranty. Electric Powered Pressure Washers used for commercial purposes are not warranted.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:

  • Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment.
  • Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments, fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
  • Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. Also excluded is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support applications.

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Show 14 more labels / short text on this page
Consumer Use · 2 years · 1 year · 1 year · 2 years · 2 years · 3 years · Commercial Use · none · 90 days · 90 days · 1 year · none · none
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
No AC output is available, but generator is running.1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad.1. Reset circuit breaker. 2. Contact Authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. p.17
Generator runs good at no-load but "bogs" down" when loads are connected.1. Short circuit in a connected load. 2. Generator is overloaded. 3. Shorted generator circuit.1. Disconnect shorted electrical load. 2. See "Don't Overload Generator". 3. Contact Authorized service facility. p.17
Generator will not start; or starts and runs rough.1. Failed battery. 2. Low oil level.1. Replace battery. 2. Fill crankcase to proper level or place generator on level surface. p.17
Generator shuts down during operation.1. Out of gasoline. 2. Low oil level.1. Fill fuel tank. 2. Fill crankcase to proper level or place generator on level surface. p.17
Generator lacks power.Load is too high.See "Don't Overload Generator". p.17

Poser une question sur : Briggs & Stratton PRO8000

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Briggs & Stratton PRO8000

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Briggs & Stratton PRO8000 manuel PDF

60 pages·2.3 MB·Groupe électrogène portable·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…