TABLE OF CONTENTS Safety Rules 2-4 Know Your Generator 5 Assembly 6-7 Operation 8-14 Maintenance 15-16 Storage 16 Troubleshooting 17 Schematic/Wiring Diagram 18-19 Replacement Parts 20-23 Notes 24 Warranty 25 EQUIPMENT
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.
Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by the engine. This generator incorporates GFCI (Ground Fault Circuit Interrupter) outlet protection and has its neutral bonded to ground to pass OSHA inspections on job sites.This generator will not function when connected to a transfer switch since the home or building main breaker box also has a neutral bonded to ground.When both the generator and the home or building breaker box contains a neutral bonded to ground, the generators GFCI will open and no outlets will function.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
Electrical Shock Electrocution Electrical Shock
Fire Explosion Toxic Fumes
DO NOT remove the neutral bond.
Explosive Pressure Chemical Burn
Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.
Hot Surface

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.
Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.


Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load.
Unintentional sparking can result in fire or electric shock.
Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.
Improper treatment of generator can damage it and shorten its life.


Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
12 Volt DC Receptacle
120 Volt AC, 20 Amp Duplex Receptacles
120 Volt AC, 30 Amp Locking Receptacle
Circuit Breakers (AC) 120/240 Volt AC, 30 Amp Locking Receptacle
12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery.
Data Tag – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.
120 Volt AC, 20 Amp Duplex Receptacles — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
Fuel Tank — Capacity of seven (7) U.S. gallons. GFCI Circuit Breaker — A GFCI circuit breaker is provided to protect against electrical ground fault and protect the generator against electrical overload.
120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
Grounding Fastener — If required, please consult a qualified electrician, electrical inspector, or local agency having jurisdiction.
120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
Hour Meter — Displays and records how many hours your generator has run (up to 9,999.9).
Idle Control Switch — The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.
Air Cleaner — Uses a dry type filter element and foam pre–cleaner to limit the amount of dirt and dust sucked into the engine. Choke Lever — Used when starting a cold engine.
Ignition Switch — Push to start and stop the engine.
Oil Fill Cap — Add oil to engine here. Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.
Circuit Breakers (AC) — Push to reset circuit breakers are provided to protect the generator against electrical overload.


ELECTRIC START
Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.
Your unit is equipped with electric start capability but can be started manually. If you choose not to use the electric start feature, you do not need to install the battery.
If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115.
Battery Wire
The sealed battery on the generator is fully charged and pre–installed except for the negative (black) battery cable.
To install: 1. Cut off tie wrap securing loose end of negative (black) cable.
Figure 1 — Negative Battery Connection
Check all contents against those listed below:
If any parts are missing or damaged, call the generator helpline at 1-800-743-4115.

Add Fuel
ENGINE
Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
Figure 2 — Typical Fuel Expansion Space
FUEL
Baffle


OPERATING THE
GENERATOR
System Ground
The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).
Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.
Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.
Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.
Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
DANGER
Disconnect all electrical loads from the generator. Use the following start instruction steps in numerical order:
Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.
Figure 3 — Fuel Shut-off Valve

Figure 4 — Idle Control Switch
Stopping the Engine 1. Turn OFF and unplug ALL electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Move idle control switch to “Off” position. 3. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. 4. Move fuel valve to “Off” position. 5. Set Ignition switch in “Stop” position.
Figure 5 — Ignition Switch
This switch is designed to greatly improve fuel economy. When this switch is turned ON, the engine will only run at its normal high governed engine speed when electrical loads are connected.When an electrical load is removed, the engine will run at a reduced speed.
With the switch off, the engine will run at the normal high engine speed. Always have the switch off when starting and stopping the engine.
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.

Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6 Volt batteries. DO NOT use the unit to crank an engine having a discharged battery.
Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage.

To recharge 12 Volt batteries, proceed as follows: 1. Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. DO NOT use tap water.


RECEPTACLES
OPERATION Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your generator may experience icing of the carburetor and/or the crankcase breather system. Build a structure that will enclose three sides and the top of the generator: 1. Make sure entire muffler-side of generator is exposed. Note that your generator may appear different from that shown in Figure 8.

Receptacles may be marked with rating value greater than generator output capacity.
Figure 8 — Permanent Cold Weather Shelter
Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volts AC at 30 Amps (or greater) (Figure 9).You can use the same 4–wire cord if you plan to run a 120 Volt load.
Figure 9 — 120/240 Volt AC, 30 Amp Receptacle
120V 120V W (Neutral)
X (Hot) Y (Hot)
Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.
This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts of power at 30 Amps for 120 Volts; 7,200 watts of power (7.2 kW) at 30 Amps for 240 Volts.The outlet is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.
Wind · 4-Wire Cord Set

Figure 11 — 120 Volt AC, 20 Amp, Duplex Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire cord set rated for 125 Volts AC at 30 Amps to the plug (Figure 10).
Figure 10 — 120 Volt AC, 30 Amp, Locking Receptacle
Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).
This receptacle (Figure 12) allows you to recharge a 12 Volt automotive or utility style storage battery.
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.6 kW) of power at 30 Amps.The outlet is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.
Figure 12 — 12 Volt DC, 10 Amp Receptacle
Each duplex receptacle (Figure 11) is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.
This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See “Charging a Battery” on page 10 before attempting to recharge a battery.This outlet is protected by a 10 Amp self resetting circuit breaker.

Ground Fault Protection This unit is equipped with a Ground Fault Circuit Interrupter (GFCI).This device meets applicable federal, state and local codes. The GFCI protects against electrical shock that may be caused if your body becomes a path which electricity travels to reach ground.This could happen if you touch a “Live” appliance or wire, or are touching plumbing or other materials that connect to the ground. When protected by a GFCI, one may still feel a shock, but the GFCI should cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury.
If circuit breaker does not reset properly:
During Generator Use If circuit breaker trips during use, it usually indicates faulty electrical equipment or cords. However, test the circuit breaker as follows;
Generator produces powerful voltage.
If circuit breaker trips in the 1 minute period:
Test GFCI Circuit Breaker Test your GFCI circuit breaker (Figure 13) every month, as follows:
Figure 13 — GFCI Circuit Breaker
If circuit breaker tests correctly:
Generator produces powerful voltage.
If circuit breaker does not trip:

Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items.This is the amount of power your generator must produce to keep your items running. See Figure 14. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Figure 14 - Wattage Reference Chart
Watts Essentials Light Bulb - 75 watt 75 - Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator/Freezer - 18 Cu. Ft. 800 1600 Water Well Pump - 1/3 HP 1000 2000 Heating/Cooling Window AC - 10,000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower - 1/2 HP 800 1300 Kitchen Microwave Oven - 1000 Watt 1000 - Coffee Maker 1500 - Electric Stove - Single Element 1500 - Hot Plate 2500 - Family Room DVD/CD Player 100 - VCR 100 - Stereo Receiver 450 - Color Television - 27” 500 - Personal Computer w/17” monitor 800 - Other Security System 180 - AM/FM Clock Radio 300 - Garage Door Opener - 1/2 HP 480 520 Electric Water Heater - 40 Gallon 4000 - DIY/Job Site Quartz Halogen Work Light 1000 - Airless Sprayer - 1/3 HP 600 1200 Reciprocating Saw 960 960 Electric Drill - 1/2 HP 1000 1000 Circular Saw - 7 1/4” 1500 1500 Miter Saw - 10” 1800 1800 Table Planer - 6” 1800 1800 Table Saw/Radial Arm Saw - 10” 2000 2000 Air Compressor - 1-1/2 HP 2500 2500
Tool or Appliance Rated (Running)
(Starting) Watts Window Air Conditioner
Refrigerator 800 1600 Deep Freezer 500 500 Television 500 - Light (75 Watts) 75 - 3075 Total Running Watts
1800 Highest Surge Watts
Total Rated (Running) Watts = 3075 Highest Additional Surge Watts = 1800 Total Generator Output Required = 4875
Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator.There should be nothing connected to the generator outlets before starting it's engine.The correct and safe way to manage generator power is to sequentially add loads as follows: 1. With nothing connected to the generator, start the engine as described in this manual. 2. Plug in and turn on the first load, preferably the largest load you have. 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
*Wattages listed are approximate only. Check tool or appliance for actual wattage.


SPECIFICATIONS Maximum Surge Watts 10,000 Watts Continuous Wattage Capacity 8,000 Watts Power Factor 1.0 Rated Maximum Continuous Load Current
NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
At 120 Volts 66.6 Amps At 240 Volts 33.3 Amps Phase 1-phase Rated Frequency 60 Hertz Fuel Tank Capacity 7 U.S. gallons Shipping Weight 270 lbs. GENERAL MAINTENANCE

Unintentional sparking can result in fire or electric shock.
The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a damaged or defective generator.
Engine Maintenance
The fuel valve is equipped with a fuel sediment cup, screen, retaining ring and o-ring that need to be cleaned every 6 months or 100 hours (whichever occurs first).
See engine owner’s manual for instructions.

Avoid prolonged or repeated skin contact with used motor oil.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.
Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.
Generator Cleaning • Use a damp cloth to wipe exterior surfaces clean.
Storage covers can be flammable.
Improper treatment of generator can damage it and shorten its life.
See engine owner’s manual for instructions.


No AC output is available, but generator is running.
Generator runs good at no-load but "bogs" down" when loads are connected.
Generator will not start; or starts and runs rough.
Generator shuts down during operation.
Generator lacks power. Load is too high. See "Don't Overload Generator".









Item Part # Description 1 B193230GS CRADLE, Gen Black 2 194209GS KIT, Engine Support Hardware 3 56893GS CRIMPTITE, 10-24 x 1/2 4 190220GS ADAPTER, Engine 5 NSP ASSY,Alternator (see page 22) 6 194151GS KIT,Adapter Mounting Hardware 7 62265GS GROMMET 8 96796GS WASHER 9 194208GS KIT,Alt to Heat Shield Hardware 10 190274BGS SCREW, SBHC, 3/8-16 x 1" 11 25254GS HHCS 5/16-24 x 9-7/8 12 189302BGS ASSY,Wire 13 * HHCS, M8 - 1.25 x 16 14 * WASHER, Shakeproof, Ext. 5/16 15 * WASHER, Shakeproof, Ext. M6 16 B77304GS SUPPORT, Engine 17 75246GS TAPTITE, 3/8 - 16 x 1-1/4 18 96867GS ASSY, Stepper Motor 19 J93074GS SUPPORT, Heatshield 20 B4986GS DECAL, Ground 21 194155GS KIT,Vibration Mount 22 194542GS KIT, Stepper Motor Hardware 23 193646GS KIT, Grounding Hardware 24 194950GS ASSY, Heat Shield 26 74908GS TAPTITE, M5 - 0.8 x 10 30 194543GS KIT,Throttle Linkage Hardware 31 191436GS DECAL, Caution Hot Muffler 33 194211GS KIT, Starter Contact Hardware 34 186347GS COVER, RBC Plastic 35 194214GS KIT, Hose, Fuel 36 194210GS KIT, Starter Mounting Hardware 37 * SCREW, Self Driller, 12-14 x 7/8 38 192376GS SCREW, 12 - 24 x 1/2 Thd Forming 40 194212GS KIT, Fuel Tank Hardware 41 193272GS VALVE, Fuel 43 B4769GS CONTACTOR, Starter 44 193299GS ASSY,Tank Fuel (Includes Items 41,
Item Part # Description 51 194799GS DECAL, Danger 52 93826GS DECAL, Operating Instructions 53 194034GS KIT, Folddown Handle Hardware 55 191435GS DECAL, Fuel Shutoff 56 95349GS PLATE,Adjust 57 189759GS KIT, Fuel Valve Repair 58 194949GS ASSY, Control Panel (see page 23) 59 * WASHER, M6 - 1/4, Int. Shakeproof 60 J193512GS SUPPORT,Tray Battery 61 95348GS BRACKET, Bell Crank 62 95921GS LINKAGE, Bell Crank to Throttle 63 96717GS SPRING 68 J192985GS TRAY, Battery 69 B4489GS BATTERY 70 * HHCS, M6 -1.0 x 12 74 193347GS KIT, Hardware Battery 76 185939GGS ASSY,Wire 78 189302EGS ASSY,Wire 83 192403YGS ASSY,Wire 85 B193200GS ASSY, Fold Down Handle (Includes
Item 86) 86 189718GS GRIP, Handle 900 NSP ENGINE
194947GS MANUAL, Owner's MS5375 MANUAL, Engine BB3061GS BOTTLE, Oil B4177GS CHARGER, Battery 65787GS CABLES, Battery Charge 193662GS KIT, Decal Service 43438GS PLUG, 120/240V, 30A 4P 37806GS PLUG, 125V, 30A 3P 193454GS SHEET, Instruction,Wheel Kit 690661 SCREW,Tapping Hex 392390 ARRESTER, Spark 692099 ASSY, Muffler 691513 BRACKET, Muffler 692056 SCREW 690898 CLAMP, Muffler 692539 SCREW
51, 52 & 57) 45 189135GS CAP,Tank Fuel 46 B4135GS PIN, Handle Release 47 77395GS NUT, Lock, M6 48 14353621GS WIRE, Ground 49 95920GS LINKAGE, Stepper Motor to Bell
* - Items without part numbers are common fasteners and are available at local hardware stores.
Crank


Item Part # Description 1 186059GS ADAPTER, Mounting,Alternator 2 192938GS ROTOR 3 192937AGS STATOR 4 186060GS RBC, with O-Ring (p/n 189197GS) 5 66449LGS HHCS, M6 - 1.0 x 190 SEMS 6 66386GS ASSY, Holder, Rectifier/Brush 7 66849GS TAPTITE, M5 - 0.8 x 16 8 22097GS WASHER, Lock, 1/4 - M6 9 81917GS PIN, Roll, 4mm x 10 10 65795GS RECTIFIER, Battery Charge 11 66849CGS TAPTITE, M5 - 0.8 x 30 12 23762GS WASHER, Shakeproof, Ext. #10 13 189769GS REGULATOR,Voltage-AVR

Item Part # Description 1 B192834GS PANEL, Control 2 B192837GS BOX, Control Panel 3 * WASHER, Flat, #10 - M5 4 * WASHER, Lock, M5 5 * PPHMS, M5 - 0.8 x 12 6 * WASHER, M6 - 1/4, Int. Shakeproof 7 82538GS SWITCH, Rocker 8 192855GS SWITCH, Rocker 9 77604GS METER, Hour 10 * WASHER, Lock, M3 11 * NUT, M3 - 0.5 12 * PHMS, M3 - 0.5 x 10 13 77314GS THERMAL, Relay 14 87962GS BREAKER, Circuit, 10A, 12V 15 84028GS TRANSFORMER, Idle Cnt 16 64525GS STANDOFF, HEX, 3/4" 17 94117GS PCB, Idle Control, 10KW 18 * PHTS, 6 - 32 x 3/8" 19 92953GS TERMINAL, Block 20 * WASHER, Lock, M4 21 * PPHMS, M4 - 0.7 x 20
Item Part # Description 22 * NUT, M4 - 0.7 23 * WASHER, Flat, M4 24 192931GS BRACKET, GFCI Breaker 25 * WASHER, Shakeproof, Int. #8 26 192828EGS BREAKER, Circuit, GFCI, 40A 27 68868GS OUTLET, 120V, 30A 28 43437GS OUTLET, 120/240V, 30A 29 68759GS OUTLET, 120V, 20A, Duplex 30 194953GS HARNESS,Wire 31 193597GS JUMPER,Terminal Block 32 75207GS BREAKER, Circuit, 20A w/hardware 33 90418GS OUTLET, 12VDC, Snap 34 B4694GS JACK, Coaxial 35 75207NGS BREAKER, Circuit, 35A, w/hardware 36 188632GS BOOT, Rubber Wire Outlet 37 77043BGS CONDUIT, Flex, .50 I.D. x 9.5 38 62265GS GROMMET
* - Items without part numbers are common fasteners and are available at local hardware stores.



BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY
Effective June 1, 2004 replaces all undated Warranties and all Warranties dated before June 1, 2004
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.
OUTBOARD
PRESSURE
WATER PUMP (Not available in the
HOME GENERATOR SYSTEM
MOTOR
WASHER
USA)
WELDER Less than 10 KW 10 KW or greater Transfer switch
3 years or 1500 hours none
* The engine and starting batteries are warranted solely by the manufacturers of those products. ** 2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and Home Generator System - Less than 10 KW, outside of European Union.
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty. Equipment used for Prime Power in place of utility are not applicable to this warranty. Electric Powered Pressure Washers used for commercial purposes are not warranted.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:
JEFFERSON, WI, USA
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| No AC output is available, but generator is running. | 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. | 1. Reset circuit breaker. 2. Contact Authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. | p.17 |
| Generator runs good at no-load but "bogs" down" when loads are connected. | 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. See "Don't Overload Generator". 3. Contact Authorized service facility. | p.17 |
| Generator will not start; or starts and runs rough. | 1. Failed battery. 2. Low oil level. | 1. Replace battery. 2. Fill crankcase to proper level or place generator on level surface. | p.17 |
| Generator shuts down during operation. | 1. Out of gasoline. 2. Low oil level. | 1. Fill fuel tank. 2. Fill crankcase to proper level or place generator on level surface. | p.17 |
| Generator lacks power. | Load is too high. | See "Don't Overload Generator". | p.17 |
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.