FR
Briggs & Stratton logo
Notice d'utilisation officielle

Briggs & Stratton Portable Generator (01532-4)

48 pages·3.8 MB·Groupe électrogène portable·PDF·ENDEITNLJA
Briggs & Stratton Portable Generator (01532-4)
Table des matières 54 sections SAFETY RULES · SAVE THESE INSTRUCTIONS · DESCRIPTION · Hazard Symbols and Meanings · … AfficherMasquer
Page 1 of the Briggs & Stratton Portable Generator (01532-4) user manual — Hazard Symbols and Meanings
Page 1 · cliquer pour agrandir
Page 1

SAFETY RULES

SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS Safety Rules 2-4 Know Your Generator 5 Assembly 6 Operation 7-12 Specifications 13 Maintenance 13 Storage 14 Troubleshooting 15 Notes 16 Warranty 17 EQUIPMENT

SAFETY RULES

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

DESCRIPTION

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.

The generators are an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is driven at about 3,600 rpm by a single- cylinder engine.

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Hazard Symbols and Meanings

Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice.

The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.

Explosive Pressure Chemical Burn

Copyright © 2005 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

Show 5 more labels / short text on this page
Toxic Fumes · Electrocution Electrical Shock · Fire Explosion · Hot Surface · Kickback
Page 2 of the Briggs & Stratton Portable Generator (01532-4) user manual — SAFETY RULES
Page 2 · cliquer pour agrandir
Page 2
Briggs & Stratton Portable Generator (01532-4) — SAFETY RULES diagram (page 2)
Fig. 1
DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. • DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. • Wear protective goggles, rubber apron, and rubber gloves.

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

  • WHEN ADDING OR DRAINING FUEL
  • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
  • Fill or drain fuel tank outdoors.
  • DO NOT overfill tank. Allow space for fuel expansion.
  • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • DO NOT light a cigarette or smoke. WHEN STARTING EQUIPMENT
  • Ensure spark plug, muffler, fuel cap and air cleaner are in place.
  • DO NOT crank engine with spark plug removed.
  • If fuel spills, wait until it evaporates before starting engine. WHEN OPERATING EQUIPMENT
  • Do not tip engine or equipment at angle which causes fuel to spill.
  • This generator is not for use in mobile equipment or marine applications. WHEN TRANSPORTING OR REPAIRING EQUIPMENT
  • Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
  • Disconnect spark plug wire. WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
  • Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

  • Operate generator ONLY outdoors.
  • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
  • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

  • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
  • DO NOT touch bare wires or receptacles.
  • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • DO NOT operate generator in the rain.
  • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • DO NOT allow unqualified persons or children to operate or service generator.
  • This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.
  • Failure to use the appropriate U. S. Coast Guard approved generator could result in death, serious injury and/or property damage.
Page 3 of the Briggs & Stratton Portable Generator (01532-4) user manual — SAFETY RULES
Page 3 · cliquer pour agrandir
Page 3

SAFETY RULES

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises or sprains could result.

Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load.

  • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.
  • DO NOT modify generator in any way.
  • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
  • NEVER start or stop engine with electrical devices plugged in and turned on.

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, etc. can catch fire.

  • See “Don’t Overload Generator”.
  • Start generator and let engine stabilize before connecting electrical loads.
  • Connect electrical loads in OFF position, then turn ON for operation.
  • Turn electrical loads OFF and disconnect from generator before stopping generator.
  • DO NOT touch hot surfaces.
  • Allow equipment to cool before touching.
  • The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
  • Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
  • In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

Improper treatment of generator can damage it and shorten its life.

  • Use generator only for intended uses.
  • If you have questions about intended use, ask dealer or contact your nearest authorized service center.
  • Operate generator only on level surfaces.
  • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
  • DO NOT insert any objects through cooling slots.
  • If connected devices overheat, turn them off and disconnect them from generator.
  • Shut off generator if: -electrical output is lost; -equipment sparks, smokes, or emits flames; -unit vibrates excessively.

Unintentional sparking can result in fire or electric shock.

  • WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.
Page 4 of the Briggs & Stratton Portable Generator (01532-4) user manual — KNOW YOUR GENERATOR
Page 4 · cliquer pour agrandir
Page 4
Briggs & Stratton Portable Generator (01532-4) — KNOW YOUR GENERATOR diagram (page 4)
Fig. 2

KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

12 Volt DC, 8.3 Amp Accessory Jack

120 Volt AC, 7.5 Amp Receptacle

Oil Fill/Drain (inside cover)

12 Volt DC, 8.3 Amp Accessory Jack — May be used to power 12 Volt DC electrical devices or recharge 12 Volt DC batteries.

Engine ON/OFF Switch — Used to stop a running engine.

Fuel Shut-Off Valve — Use this valve to turn the fuel supply on and off.

120 Volt AC, 7.5 Amp Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

Fuel Tank — Capacity of 1.2 U.S. gallons (4.5 liters) of fuel.

Grounding Lug — Use this connection to properly ground the generator. See ”System Ground” on page 7.

Air Cleaner — Protects engine by filtering dust and debris out of intake air.

Oil Fill/Drain — Access to oil fill dipstick and engine oil drain plug.

Choke Lever — Used to manually provide proper starting mixture when engine is cold.

Recoil Starter — Used for starting the engine.

Circuit Breaker (AC) — Receptacles are provided with a push-to-reset circuit breaker to protect the generator against electrical overload.

Spark Plug — Access to engine spark plug.

Data Tag — Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.

Show 11 more labels / short text on this page
Spark Plug (inside · Fuel Tank · cover) · Engine ON/OFF Switch · Choke Lever · Circuit Breaker (AC) · Air Cleaner · Fuel Shut-Off Valve · Recoil Starter · Data Tag · Grounding Lug
Page 5 of the Briggs & Stratton Portable Generator (01532-4) user manual — Carton Contents
Page 5 · cliquer pour agrandir
Page 5

ASSEMBLY

ASSEMBLY

BEFORE STARTING ENGINE

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.

Add Engine Oil and Fuel

  • Place generator on a level surface.

If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the model, revision, and serial number from the data tag available.

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

  • Refer to engine manual for oil and fuel fill information.
  • Damage to equipment resulting from failure to follow this instruction will void warranty.

Remove Generator From Carton

1. Set carton on a rigid flat surface with “This Side Up” arrows pointing upward.
  • Refer to engine owner’s manual and follow oil and fuel recommendations and instructions.
2. Carefully open top flaps of shipping carton.
3. Cut down corners at one end of carton from top to bottom and lay that side of carton down flat.
4. Remove all packing material, carton fillers, etc.
5. Remove generator from shipping carton.

Carton Contents

Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-743-4115. Shipped with your generator is:

  • Main unit
  • Owners manual
  • Engine manual
  • Battery charge cables
  • Oil bottle
Page 6 of the Briggs & Stratton Portable Generator (01532-4) user manual — Connecting to a Building’s Electrical
Page 6 · cliquer pour agrandir
Page 6
Briggs & Stratton Portable Generator (01532-4) — USING THE GENERATOR diagram (page 6)
Fig. 3

USING THE GENERATOR

Generator Location

Generator Clearance

System Ground

Briggs & Stratton Portable Generator (01532-4) — Generator Clearance diagram (page 6)
Fig. 4 · Generator Clearance
WARNING fRunning generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, ainting or death. • Operate generator ONLY outdoors. • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings. • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is not connected to the AC neutral wire. If the generator is tested by a receptacle tester, it will not show the same ground circuit condition as for a home receptacle.

Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.

  • In some areas, generators are required to be registered with local utility companies.
  • If the generator is used at a construction site, there may be additional regulations which must be observed.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 1). Prevailing winds and air currents should be taken into consideration when positioning generator.

Connecting to a Building’s Electrical

System

Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

Briggs & Stratton Portable Generator (01532-4) — Connecting to a Building’s Electrical diagram (page 6)
Fig. 5 · Connecting to a Building’s Electrical

Generator produces powerful voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

  • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
  • DO NOT touch bare wires or receptacles.
  • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
  • DO NOT operate generator in the rain.
  • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
  • DO NOT allow unqualified persons or children to operate or service generator.
Page 7 of the Briggs & Stratton Portable Generator (01532-4) user manual — Connecting Electrical Loads
Page 7 · cliquer pour agrandir
Page 7

OPERATING THE

GENERATOR

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises or sprains could result.

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

  • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
  • NEVER start or stop engine with electrical devices plugged in and turned on.
  • See “Don’t Overload Generator”.
  • Start generator and let engine stabilize before connecting electrical loads.
  • Connect electrical loads in OFF position, then turn ON for operation.
  • Turn electrical loads OFF and disconnect from generator before stopping generator.

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions:

  • DO NOT touch hot surfaces.
  • Allow equipment to cool before touching.
  • The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
  • Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
  • In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.
1. Make sure unit is on a level surface.
2. Turn the fuel valve to the “ On ” position (Figure 2). The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 2 — Fuel Valve in Open Position

Connecting Electrical Loads

  • Let engine stabilize and warm up for a few minutes after starting.
  • Plug in and turn on the desired 120 Volt AC, single phase, 60 Hz electrical loads.
  • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.
  • DO NOT connect 3–phase loads to the generator.
  • DO NOT connect 50 Hz loads to the generator.
3. Start engine according to instructions given in the engine owner’s manual.
  • DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload Generator”.
Page 8 of the Briggs & Stratton Portable Generator (01532-4) user manual — Charging a Battery
Page 8 · cliquer pour agrandir
Page 8
Briggs & Stratton Portable Generator (01532-4) — Stopping the Engine diagram (page 8)
Fig. 6 · Stopping the Engine

Stopping the Engine

3. If the battery is equipped with vent caps, make sure they are installed and are tight.
1. Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON .
4. Connect battery charge cable connector plug to the 12 Volt DC panel receptacle.
5. Connect battery charge cable clamp with red handle to battery post or terminal indicated by Positive , POS or ( + ) (Figure 3).
2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.
Figure 3 — Battery Connections To 12 Volt DC Panel Receptacle Red Lead Negative Positive 6. Connect battery charge cable clamp with black handle
Briggs & Stratton Portable Generator (01532-4) — Stopping the Engine diagram (page 8)
Fig. 7 · Stopping the Engine
3. Turn engine off according to instructions given in the engine owner’s manual.
4. Move fuel valve to “ Off ” position.

Charging a Battery

Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. DO NOT use the unit to charge any 6 Volt batteries. DO NOT use the unit to crank an engine having a discharged battery.

DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid will cause severe chemical burns. • DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery. • Wear protective goggles, rubber apron, and rubber gloves.
7. Start generator. Let the engine run while battery recharges.
8. When battery has charged, shut down engine (see “Stopping The Engine”)

To recharge 12 Volt batteries, proceed as follows: 1. If necessary, clean battery posts or terminals.

2. Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. DO NOT use tap water.
Page 9 of the Briggs & Stratton Portable Generator (01532-4) user manual — 12 Volt DC Accessory Jack
Page 9 · cliquer pour agrandir
Page 9

CONNECTOR PLUGS

This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See “Charging a Battery” (page 9) before attempting to recharge a battery.

Receptacles may be marked with rating value greater than generator output capacity.

EXTENSION CORDS

  • NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.
  • DO NOT overload the generator. See “Don’t Overload Generator”.

Use only high quality, well-insulated, extension cords with the generator’s 120 Volt electrical receptacles.

Check the ratings of all extension cords before you use them. Such cords should be rated for 125 Volt AC loads at 15 Amps (or greater) for most electrical devices. Some devices, however, may not require this type of extension cord. Check the owner’s manuals of those devices for their recommendations.

120 Volt AC, 15 Amp Receptacle

Each outlet socket is protected against overload by a 7.5 Amp push-to-reset circuit breaker. Use each receptacle to operate 120 Volt AC, single phase, 60 Hz electrical loads requiring up to 1,000 watts (1.0 kW) of power (Figure 4).

Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.

Figure 4 — 120 Volt AC, 15 Amp Duplex Receptacle

COLD WEATHER

Under certain weather conditions (temperatures below 40°F [4°C] combined with high humidity), your generator may experience icing of the carburetor and/or the crankcase breather system. To reduce this problem, you need to perform the following:

12 Volt DC Accessory Jack

This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cable provided. Camping-style air pumps, lanterns, fans, or other 12 Volt devices having a cigarette lighter-type plug may also be powered by this outlet (Figure 5).

1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil (synthetic preferred, see engine manual).

Figure 5 — 12 Volt DC Accessory Jack

4. Check oil level daily or after every eight (8) hours of operation.
5. Maintain generator following “Maintenance Schedule” in engine manual.
6. Shelter unit from elements.
Page 10 of the Briggs & Stratton Portable Generator (01532-4) user manual — CONNECTOR PLUGS
Page 10 · cliquer pour agrandir
Page 10
Briggs & Stratton Portable Generator (01532-4) — CONNECTOR PLUGS diagram (page 10)
Fig. 8

In an emergency, use the original shipping carton as a temporary shelter:

For a more permanent shelter, build a structure that will enclose three sides and the top of the generator.

7. Cut off all carton flaps.
7. Make sure entire muffler-side of generator is exposed, as shown in Figure 6.
8. Cut out one long side of carton to expose muffler side of unit as shown in Figure 6.
Briggs & Stratton Portable Generator (01532-4) — CONNECTOR PLUGS diagram (page 10)
Fig. 9
8. Face exposed end away from wind and elements.
9. Structure should hold enough heat created by the generator to prevent icing problem.
10. Start and run engine outdoors.
11. Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
Briggs & Stratton Portable Generator (01532-4) — CONNECTOR PLUGS diagram (page 10)
Fig. 10

Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death.

  • Operate generator ONLY outdoors.
  • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
  • DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C). Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush, ect. can catch fire.

12. DO NOT enclose generator any more than shown in Figure 6.
13. Remove shelter when temperatures are above 40°F [4°C].
  • DO NOT touch hot surfaces.
  • Allow equipment to cool before touching.
  • The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
  • Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
  • Remove shelter when temperatures are above 40°F [4°C].
14. Turn engine OFF and let cool two (2) minutes before refueling.
9. Cut appropriate slots to access receptacles of unit.
10. Start unit, then place carton over it.
Page 11 of the Briggs & Stratton Portable Generator (01532-4) user manual — Example:
Page 11 · cliquer pour agrandir
Page 11
Briggs & Stratton Portable Generator (01532-4) — DON'T OVERLOAD diagram (page 11)
Fig. 11

DON'T OVERLOAD

4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.

GENERATOR

Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Figure 7. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Figure 7 - Wattage Reference Chart Tool or ApplianceRated* (Running) WattsAdditional Surge (Starting) Watts Essentials Light Bulb - 75 watt75- Deep Freezer500500 Sump Pump8001200 Refrigerator/Freezer - 18 Cu. Ft.8001600 Water Well Pump - 1/3 HP10002000 Heating/Cooling Window Fan300600 Furnace Fan Blower - 1/2 HP8001300 Kitchen Microwave Oven - 1000 Watt1000- Coffee Maker1500- Electric Stove - Single Element1500- Hot Plate2500- Family Room Stereo Receiver450- Television - 27”500- Personal Computer w/17” monitor800- Other AM/FM Clock Radio300- Electric Water Heater - 40 Gallon4000- Quartz Halogen Work Light1000- Airless Sprayer - 1/3 HP6001200 Reciprocating Saw960960 Electric Drill - 1/2 HP10001000 Circular Saw - 7 1/4”15001500 Miter Saw - 10”18001800 Table Saw/Radial Arm Saw - 10”20002000 Air Compressor - 1-1/2 HP25002500

Example:

Tool or ApplianceRated (Running) WattsAdditional Surge (Starting) Watts Deep Freezer500500 Television500- Light (75 Watts)75- 1075 Total Running Watts500 Highest Surge Watts

Total Rated (Running) Watts = 1075 Highest Additional Surge Watts = 500 Total Generator Output Required = 1575

Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting it's engine. The correct and safe way to manage generator power is to sequentially add loads as follows: 1. With nothing connected to the generator, start the engine as described in this manual. 2. Plug in and turn on the first load, preferably the largest load you have. 3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly.

*Wattages listed are approximate only. Check tool or appliance for actual wattage.

Page 12 of the Briggs & Stratton Portable Generator (01532-4) user manual — Engine Maintenance
Page 12 · cliquer pour agrandir
Page 12

SPECIFICATIONS AND MAINTENANCE

SPECIFICATIONS

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Starting Wattage 1,000 Watts Wattage 900 Watts Rated Current

At 120 Volts AC 7.5 Amps At 12 Volts DC 8.3 Amps Phase Single Phase Rated Frequency 60 Hertz Packaged Weight 61 lbs. GENERAL MAINTENANCE

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a damaged or defective generator.

Unintentional sparking can result in fire or electric shock.

  • WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.

Engine Maintenance

See engine owner’s manual for instructions.

Avoid prolonged or repeated skin contact with used motor oil.

  • Used motor oil has been shown to cause skin cancer in certain laboratory animals.
  • Thoroughly wash exposed areas with soap and water.

Generator Cleaning • Use a damp cloth to wipe exterior surfaces clean.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Improper treatment of generator can damage it and shorten its life.

  • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
  • DO NOT insert any objects through cooling slots.
  • Use a soft bristle brush to loosen caked on dirt or oil.
  • Use a vacuum cleaner to pick up loose dirt and debris.
  • Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator. These openings must be kept clean and unobstructed.
Page 13 of the Briggs & Stratton Portable Generator (01532-4) user manual — Generator Storage
Page 13 · cliquer pour agrandir
Page 13

STORAGE

STORAGE

Engine Storage

See engine owner’s manual for instructions.

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Other Storage Tips

  • To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor. The unit and fuel can then be stored for up to 24 months. Fuel stabilizer can be purchased locally.

Generator Storage

  • Clean the generator as outlined in “Generator Cleaning”.
  • Check that cooling air slots and openings on generator are open and unobstructed.
  • DO NOT store fuel from one season to another unless it has been treated as described above.
  • Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.

Storage covers can be flammable.

  • Store unit in a clean and dry area.
  • DO NOT place a storage cover over a hot generator.
  • Let equipment cool for a sufficient time before placing the cover on the equipment.
Page 14 of the Briggs & Stratton Portable Generator (01532-4) user manual — TROUBLESHOOTING
Page 14 · cliquer pour agrandir
Page 14

TROUBLESHOOTING

TROUBLESHOOTING

Problem Cause Correction

1. One of the circuit breakers is open.
1. Reset circuit breaker.
2. Fault in generator.
2. Contact Authorized service facility.

No AC output is available, but generator is running.

3. Poor connection or defective cord set.
3. Check and repair.
4. Connected device is bad.
4. Connect another device that is in good condition.
1. Short circuit in a connected load.
1. Disconnect shorted electrical load.

Generator runs good at no-load but "bogs" down" when loads are connected.

2. Generator is overloaded.
2. See "Don't Overload Generator".
3. Shorted generator circuit.
3. Contact Authorized service facility.

Generator will not start; or starts and runs rough.

Low oil level. Fill crankcase to proper level or place generator on level surface.

1. Out of gasoline.
1. Fill fuel tank.

Generator shuts down during operation.

2. Low oil level.
2. Fill crankcase to proper level or place generator on level surface.

Generator lacks power. Load is too high. See "Don't Overload Generator".

Page 15 of the Briggs & Stratton Portable Generator (01532-4) user manual — NOTES
Page 15 · cliquer pour agrandir
Page 15

NOTES

NOTES

Page 16 of the Briggs & Stratton Portable Generator (01532-4) user manual — BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
Page 16 · cliquer pour agrandir
Page 16

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY

Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.

OUR EQUIPMENT*

OUTBOARD

PRESSURE

WATER PUMP (Not available in the

PORTABLE GENERATOR

HOME STANDBY GENERATOR SYSTEM

MOTOR

WASHER

USA)

WELDER Less than 10 KW 10 KW or greater Transfer switch

WARRANTY PERIOD**

3 years or 1500 hours none

* The engine and starting batteries are warranted solely by the manufacturers of those products. ** 2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and Home Standby Generator System - Less than 10 KW, outside of European Union.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty. Equipment used for prime power in place of utility are not applicable to this warranty. Electric powered pressure washers used for commercial purposes are not warranted.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:

  • Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment.
  • Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments, fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
  • Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. This warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support applications.

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Show 14 more labels / short text on this page
Consumer Use · 2 years · 1 year · 1 year · 2 years · 2 years · 3 years · Commercial Use · none · 90 days · 90 days · 1 year · none · none
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
No AC output is available, but generator is running.1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad.1. Reset circuit breaker. 2. Contact Authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. p.14
Generator runs good at no-load but "bogs" down" when loads are connected.1. Short circuit in a connected load. 2. Generator is overloaded. 3. Shorted generator circuit.1. Disconnect shorted electrical load. 2. See "Don't Overload Generator". 3. Contact Authorized service facility. p.14
Generator will not start; or starts and runs rough.Low oil level.Fill crankcase to proper level or place generator on level surface. p.14
Generator shuts down during operation.1. Out of gasoline. 2. Low oil level.1. Fill fuel tank. 2. Fill crankcase to proper level or place generator on level surface. p.14
Generator lacks power.Load is too high.See "Don't Overload Generator". p.14

Poser une question sur : Briggs & Stratton Portable Generator (01532-4)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Briggs & Stratton Portable Generator (01532-4)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Briggs & Stratton Portable Generator (01532-4) manuel PDF

48 pages·3.8 MB·Groupe électrogène portable·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…