This generator is rated in accordance with CSA (Canadian Standards
Association) standard C22.2 No. 100-04 (motors and generators).
MILWAUKEE, WISCONSIN, U.S.A.
Manual No. 311157GS Revision C

Thank you for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them. This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment. Save these original instructions for future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final assembly procedures. Follow the instructions completely.
Where to Find Us You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at BRIGGSandSTRATTON.COM.
Date Purchased
Copyright © 2011. Briggs & Stratton Power Products Group, LLC Milwaukee, WI, USA. All rights reserved. BRIGGS & STRATTON POWER PRODUCTS is a registered trademark of Briggs & Stratton Corporation Milwaukee, WI, USA
Model Number · Revision · Serial Number



Safety Symbols and Meanings
Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating and direct current (AC & DC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is driven at about 4,500 rpm (with POWERSMART mode switch off) by a single-cylinder engine.
Hot Surface Moving Parts
Explosive Pressure Chemical Burn
Every effort has been made to ensure that the information in this manual is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve the generator and this documentation at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board.
The safety alert symbol indicates a potential personal injury hazard. A signal word (DANGER, WARNING, or CAUTION) is used with the alert symbol to designate a degree or level of hazard seriousness. A safety symbol may be used to represent the type of hazard. The signal word NOTICE is used to address practices not related to personal injury.
Important Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others. You must also make sure that the procedure, work method or operating technique that you choose does not render the generator unsafe.

flammable and explosive which could cause burns, fire or explosion resulting in death, serious injury and/or property damage. WHEN ADDING OR DRAINING FUEL
WHEN OPERATING EQUIPMENT • DO NOT operate this product inside any building, carport, porch, mobile equipment, marine applications, or enclosure.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

shock or burn resulting in death or serious injury.
electric shock resulting in death or serious injury.
entangle hands, hair, clothing, or accessories resulting in serious injury.

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115. If calling for assistance, please have the model, revision, and serial number from the identification label available. See Generator Features and Controls for identification label location.
Unpack Generator
Fuel must meet these requirements:
The generator is supplied with:
To protect the fuel system from gum formation, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands. This engine is certified to operate on gasoline. The emission control system for this engine is EM (Engine Modifications).

Special Requirements There may be Federal, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:

Clearances and Air Movement

combustibles, structures or damage fuel tank causing a fire, resulting in death, serious injury and/or property damage. • Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.
High Altitude At altitudes over 5,000 feet (1524 meters), a minimum 85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See a Briggs & Stratton Authorized Dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended.
Place generator outdoors in an area that will not accumulate deadly exhaust gas. DO NOT place generator where exhaust gas (C) could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning generator.

Fuel Tank Cap Vent Lever The fuel tank cap is provided with a vent lever (B) to seal the fuel tank. The vent lever must be in the “ON” position for the engine to run.

When the engine is not in use, leave the vent lever in the “OFF” position to reduce the possibility of fuel leakage. Allow the engine to cool before turning the vent lever to the “OFF” position.
Grounding Fastener The generator neutral is floating, which means that the AC stator winding is isolated from the grounding fastener and the AC receptacle ground pins. On a floating neutral generator the AC receptacle ground pins are not functional. Electrical devices, such as a GFCI, requiring a functioning AC receptacle ground pin will not operate.

Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

A - Fuel Tank Cap Vent Lever — Turn the vent lever to the
L - Overload Alarm — A red LED light comes on and cuts
“On” position when operating generator. Turn to the “Off” position when not in use. B - Fuel Tank — Capacity of 1.0 U.S. gallons (3.7 L). C - Choke Lever — Used when starting a cold engine. D - Side Maintenance Cover — Remove to gain access to
power to the receptacles when the generator is overloaded. M - Low Oil Indicator — A yellow LED light comes on when
the oil in the generator drops below a preset level. N - POWERSMART Switch— Use this switch to turn the
POWERSMART mode on and off. P - Spark Arrester Muffler — Exhaust muffler lowers engine
the air cleaner and oil service. E - Recoil Starter — Used to start the engine manually. F - Engine Switch — Set this switch to “On” before using
noise and is equipped with a spark arrester screen. R - Top Maintenance Cover — Remove to gain access to
recoil starter. Set switch to “Off” to stop engine. Also turns fuel valve on and off. G - Output Indicator — A green LED light comes on when
the spark plug.
Items Not Shown: Air Cleaner (under side maintenance cover) — Protects engine by filtering dust and debris out of intake air. Identification Label — Provides model, revision, and serial number of generator. Please have these readily available when calling for assistance. Oil Fill Cap (under side maintenance cover) — Check and add engine oil here.
the generator is working correctly and producing power at the receptacles. H - 12 Volt DC Receptacle — Use this receptacle with
battery charge cables to charge a 12 Volt battery. This receptacle is protected by a push to reset circuit breaker. J - Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area. K - 120 Volt AC, 20 Amp, Duplex Receptacle — May be
used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool, and motor loads.

Cord Sets and Receptacles Use only high quality, well-insulated, grounded extension cords with the generator’s receptacles. Inspect extension cords before each use. Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for AC loads 15 Amps or greater. Check operator’s manuals of devices to be powered for the manufacturer’s recommendations. Keep extension cords as short as possible to minimize voltage drop.
12 Volt DC Receptacle The maximum current available for the battery charge circuit is 5 Amps. A DC circuit breaker protects this receptacle from overloads. If an overload occurs, the circuit breaker will trip (push button pops out). Wait a few minutes and push the button in to reset the circuit breaker. This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cable provided.
120 Volt AC, 20 Amp, Duplex Receptacle The duplex receptacle is protected against overload by an internal overload system.
This receptacle can not be used to crank an engine having a discharged battery. See Charging a Battery before attempting to recharge a battery. NOTICE When using the battery charge circuit, turn the POWERSMART switch to the “Off” position.
Output Indicator The green LED output indicator light comes on when the generator is operating normally. It indicates that the generator is producing power at the receptacles.
Use receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 1,600 watts (1.6 kW) at 13.3 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 15 Amps (or greater).
Overload Alarm The red LED overload alarm light comes on and cuts power to the receptacles if you overload the generator. The green output indicator light will also go off. If the generator was overloaded, you must turn off and unplug all electrical loads, shut down the generator and restart it to continue in normal operating mode.
Low Oil Indicator The low oil indicator system is designed to prevent engine damage caused by not enough engine oil. If the engine oil level drops below a preset level, the yellow LED low oil indicator light comes on and an oil switch will stop the engine. If the engine stops or the yellow LED low oil indicator light comes on when you pull the recoil handle, check the engine oil level.

To start engine thereafter:
6B. Grasp recoil handle and pull slowly until slight resistance is felt. Then pull rapidly one time only to start engine.
Starting the Engine Disconnect all electrical loads from the generator. Use the following start instructions:

To recharge 12 Volt batteries, proceed as follows:


and explosive which could cause burns, fire or explosion resulting in death, serious injury and/or property damage. • DO NOT stop engine by moving choke control to “Choke” position ( ).
This feature is designed to greatly improve fuel economy. When this switch is turned ON, the engine speed will increase as electrical loads are connected, and decreased as electrical loads are removed. With the switch off, the engine will run at full governed speed. Always have the switch OFF when starting and stopping the engine. NOTICE Always have the switch OFF when starting or stopping the generator or when using the DC receptacle.
Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. NOTICE

NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.
Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Wattage Reference Guide. 3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Essentials Light Bulb - 75 watt 75 — Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator/Freezer - 18 cf 800 1600 Water Well Pump - 1/3 hp 1000 2000 Heating/Cooling Window AC - 10,000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower - 1/2 hp 800 1300 Kitchen Microwave Oven - 1000 Watt 1000 — Coffee Maker 1500 — Electric Stove - Single Element 1500 — Hot Plate 2500 — Family Room DVD/CD Player 100 — VCR 100 — Stereo Receiver 450 — Color Television - 27 in 500 — Personal Computer w/17 in monitor
Example:

(Starting) Watts Window Fan 300 600 Deep Freezer 500 500 Television 500 — Security System 180 —
Light (75 Watts) 75 — 1555 Total Running Watts
Total Rated (Running) Watts = 1555 Highest Additional Surge Watts = 600 Total Generator Output Required = 2155
Power Management To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting its engine. The correct and safe way to manage generator power is to sequentially add loads as follows:
Other Security System 180 — AM/FM Clock Radio 300 — Garage Door Opener - 1/2 hp 480 520 Electric Water Heater - 40 gallon 4000 — DIY/Job Site Quartz Halogen Work Light 1000 — Airless Sprayer - 1/3 hp 600 1200 Reciprocating Saw 960 960 Electric Drill - 1/2 hp 1000 1000 Circular Saw - 7-1/4 in 1500 1500 Miter Saw - 10 in 1800 1800 Table Planer - 6 in 1800 1800 Table Saw/Radial Arm Saw - 10 in 2000 2000 Air Compressor - 1-1/2 hp 2500 2500
* Wattages listed are approximate only. Check tool or appliance for actual wattage.

Emissions Control Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.
Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.
Every 8 Hours or Daily
Generator Maintenance Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material. NOTICE DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Every 50 Hours or 3 Months
Every 100 Hours or 6 Months
Cleaning Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Keep the area around and behind the muffler free from any combustible debris. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed. Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:
Every 250 Hours or Yearly
1 Service more often under dirty or dusty conditions.
General Recommendations Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service. The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
Some adjustments will need to be made periodically to properly maintain your generator. All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above. NOTICE Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.
First 10 Hours

Cleaning Fuel Strainer The fuel strainer helps prevent debris from entering the fuel system. Clean the fuel strainer as follows:
Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.



Oil Recommendations We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.

* Below 40°F (4°C) the use of SAE 30 will result in hard starting.
** Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.
Oil · Adding Engine Oil

Changing Engine Oil If you are using your generator under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often.
Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Service more often if operating under dirty or dusty conditions.
To service the air cleaner, follow these steps:
KEEP OUT OF REACH OF CHILDREN. DON’T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Change the oil while the engine is still warm from running, as follows:
1. Make sure generator is on a level surface. 2. Loosen the side maintenance cover screws and remove the side maintenance cover. 3. Clean area around oil fill and remove oil fill cap. 4. Tip your generator to drain oil from oil fill into a suitable container making sure you tip your unit toward the oil filler neck. When crankcase is empty, return generator to upright position. 5. Slowly pour oil (about 13.5 oz.) into oil fill opening to the point of overflowing at oil fill cap. DO NOT overfill.
3. Carefully remove foam air cleaner (C) by pulling it out towards you. 4. Carefully remove breather filter (D) by pulling it out towards you. 5. Wash foam air cleaner and breather filter in liquid detergent and water only. Squeeze dry in a clean cloth. 6. SATURATE foam air cleaner in clean engine oil and squeeze in a clean cloth to remove excess oil. 7. Reinstall clean or new foam air cleaner inside base. 8. Reinstall clean or new breather filter inside base. 9. Reinstall the air cleaner cover and tighten screw. 10. Reinstall the side maintenance cover and hand tighten the cover screws.
Service Spark Plug Changing the spark plug will help your engine to start easier and run better.

Clean and inspect the spark arrester as follows:
Inspect Muffler and Spark Arrester Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if equipped, and inspect for damage or carbon blockage. If replacement parts are required, make sure to use only original equipment replacement parts.
Check Valve Clearance Regular valve clearance check and adjustment will improve performance and extend engine life. This procedure cannot be done without partial engine disassembly and the use of special tools. For this reason we recommend that you have an authorized Service Dealer check and adjust valve clearance at recommended intervals (see Maintenance Schedule in the Maintenance section). WARNING Exhaust heat/gases could ignite

Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.
Change Engine Oil While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil.
Long Term Storage Instructions Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs & Stratton FRESH START® fuel stabilizer, available as a liquid additive or a drip concentrate cartridge. There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to 24 months. If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.
resulting in death, serious injury and/or property damage.
Other Storage Tips · Generator Storage

Engine is running, but no AC output is available.
Engine runs good at no-load but “bogs down” when loads are connected.
Engine will not start; shuts down when running or starts and runs rough.
Engine lacks power.
Engine “hunts” or falters. Carburetor is running too rich or too lean. Contact authorized service facility.
Problem Cause Correction



Briggs & Stratton Emissions Control Warranty Provisions The following are specific provisions relative to your Emissions Control Warranty Coverage. It is in addition to the B&S engine warranty for non-regulated engines found in the Operator’s Manual.
Your Warranty Rights And Obligations The California Air Resources Board, U.S. EPA, and Briggs & Stratton (B&S) are pleased to explain the emissions control system warranty on your Model Year 2011-2012 engine/equipment. In California, new small off-road engines and large spark ignited engines less than or equal to 1.0 liter must be designed, built, and equipped to meet the State’s stringent anti-smog standards. B&S must warrant the emissions control system on your engine/equipment for the periods of time listed below provided there has been no abuse, neglect, or improper maintenance of your engine or equipment. Your emissions control system may include parts such as the carburetor or fuel injection system, fuel tank, ignition system, and catalytic converter. Also included may be hoses, belts, connectors, sensors, and other emissions-related assemblies. Where a warrantable condition exists, B&S will repair your engine/equipment at no cost to you including diagnosis, parts, and labor.
Manufacturer’s Warranty Coverage: Small off-road engines and large spark ignited engines less than or equal to 1.0 liter are warranted for two years. If any emissions-related part on your engine/equipment is defective, the part will be repaired or replaced by B&S.
Owner’s Warranty Responsibilities:

The warranty on emissions-related parts is as follows:
Look For Relevant Emissions Durability Period and Air Index Information On Your Small Off-Road Engine Emissions Label Engines that are certified to meet the California Air Resources Board (CARB) small off-road Emissions Standard must display information regarding the Emissions Durability Period and the Air Index. Briggs & Stratton makes this information available to the consumer on our emissions labels. The engine emissions label will indicate certification information. The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant, assuming proper maintenance in accordance with the Operating & Maintenance Instructions. The following categories are used:
Moderate: Engine is certified to be emissions compliant for 125 hours of actual engine running time.
Intermediate: Engine is certified to be emissions compliant for 250 hours of actual engine running time.
Extended: Engine is certified to be emissions compliant for 500 hours of actual engine running time. For example, a typical walk-behind lawn mower is used 20 to 25 hours per year. Therefore, the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years. Briggs & Stratton engines are certified to meet the United States Environmental Protection Agency (USEPA) Phase 2 emissions standards. For Phase 2 certified engines, the Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emissions requirements. For engines less than 225 cc displacement. Category C = 125 hours Category B = 250 hours Category A = 500 hours For engines of 225 cc or more displacement. Category C = 250 hours Category B = 500 hours Category A = 1000 hours

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY
Effective November 1, 2009; replaces all undated Warranties and all Warranties dated before November 1, 2009.
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON.COM.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state or country to country.
*Second year parts only
The warranty period begins on the date of purchase by the first retail end user, and continues for the period of time stated above. “Consumer Use" means personal residential household use by a retail consumer. “Commercial Use" means all other uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:
MILWAUKEE, WI, USA

Product Specifications
Starting Wattage 2,000 Watts Wattage* 1,600 Watts Load Current:
at 120 Volts AC 13.3 Amps at 12 Volts DC 5 Amps Rated Frequency 60 Hertz Phase Single Phase Displacement 6.44 cu. in. (105.6 cc) Spark Plug Gap 0.023-0.027 in. (0.6-0.7 mm) Intake Valve Clearance 0.0031 - 0.0047 in.
(0.08 - 0.12 mm) cold Exhaust Valve Clearance 0.0051 - 0.0067 in.
(0.13 - 0.17 mm) cold Fuel Capacity 1.0 U.S. gallon (3.7 L) Oil Capacity 13.5 Ounces (0.4 L)
Foam Air Cleaner 311388GS Breather Filter 311389GS Resistor Spark Plug NGK CR7HSA Engine Oil Bottle 100005 or 100028 Synthetic Oil Bottle 100074 Fuel Stabilizer 100002 or 5041
Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and rating performance has been obtained and corrected in accordance with SAE J1995 (Revision 2002-05). Torque values are derived at 3060 RPM; horsepower values are derived at 3600 RPM. Net power values are taken with exhaust and air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher than net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the wide array of products on which engines are placed, the gas engine may not develop the rated gross power when used in a given piece of power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components (air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to-engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of higher rated power for this Series engine.
* This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators).
Briggs & Stratton Power Products Group, LLC
P.O. Box 702 Milwaukee, Wisconsin, 53201-0702 U.S.A.
(800) 743-4115


Este generador está clasificado conforme a la norma C22.2 No. 100-04
(motores y generadores) de la CSA (Canadian Standards Association
[Asociación canadiense de normalización]).
MILWAUKEE, WISCONSIN, U.S.A.
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Engine is running, but no AC output is available. | 1. Red overload alarm light is on. Generator is overloaded. 2. Green output indicator light not on. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. | 1. See Don’t Overload Generator in Operation section. Shut down generator and restart. 2. Contact authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. | p.19 |
| Engine runs good at no-load but “bogs down” when loads are connected. | 1. Short circuit in a connected load. 2. Engine speed is too slow. 3. Generator is overloaded. 4. Shorted generator circuit. | 1. Disconnect shorted electrical load. 2. Contact authorized service facility. 3. See Don’t Overload Generator in Operation section. 4. Contact authorized service facility. | p.19 |
| Engine will not start; shuts down when running or starts and runs rough. | 1. Engine switch set to “Off”. 2. Fuel cap vent lever is in “Off” position. r o 3. Low oil indicator light comes on. Low oil level. f 4. Dirty air cleaner. c t 5. Out of fuel. o u 6. Stale fuel. N d 7. Spark plug wire not connected to spark o plug. 8. Bad spark plug. r 9. Water in fuel. p e 10. Flooded. 11. Excessively rich fuel mixture. R 12. Intake valve stuck open or closed. 13. Engine has lost compression. | 1. Set engine switch to “On”. 2. Turn fuel cap vent lever to “On” n position. o 3. Fill crankcase to proper level or place generator on level surface. i t 4. Clean or replace air cleaner. 5. Fill fuel tank. 6. Drain fuel tank and carburetor; fill with fresh fuel. 7. Connect wire to spark plug. 8. Replace spark plug. 9. Drain fuel tank and carburetor; fill with fresh fuel. 10. Wait 5 minutes and re-crank engine. 11. Contact authorized service facility. 12. Contact authorized service facility. 13. Contact authorized service facility. | p.19 |
| Engine lacks power. | 1. Load is too high. 2. Dirty air filter. | 1. See Don’t Overload Generator in Operation section. 2. Replace air filter. | p.19 |
| Engine “hunts” or falters. | Carburetor is running too rich or too lean. | Contact authorized service facility. | p.19 |