Thank you and congratulation on your purchase of our electric fireplace product. Please read the installation instructions before installing and operating this appliance. IMPORTANT: Read all the instructions and warnings carefully before using. Failure to follow these instructions may result in a possible electric shock, fire hazard and/or injury. If you are assembling this unit for someone else, give this manual to him or her to read and save for future reference.
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE Wherever the manual speaks about the heater, this only applies for the MF1530H and the MF1510H units. I. Please ensure the following points before installation: 1. The rated voltage and power supply of the electric fireplace must be the same; 2. The fireplace bulbs should be in a good condition. Please refer to the maintenance section of the manual. II. The electric fireplace heater may give off a little harmless odor upon first use which is normal and will soon disappear. III. If the fireplace does not give off any heat, first check that the heating switch is in the correct position. For detailed information, please refer to the operation section of the manual.

Please read the following specifications thoroughly and follow them carefully to prevent accidental fire, electric shock and physical injury.
1. Please read the specifications carefully before using the product. 2. The electric fireplace will get hot when in use. Please do not touch the hot surfaces or bulb as this can result in a burn. Also, please keep flammable materials such as clothes, bedclothes, furniture, paper and curtains 100cm away from the fireplace. Do not cover or block the heater’s outlet or other outlets at any time. Do not place the fireplace on a soft surface because this may also block the outlet. 3. Keep this electrical appliance out of reach of children or persons with reduced physical or men tal capabilities. Do not let them use the appliances without supervision. 4. Do not install this electric fireplace directly on a carpet or on any other surface that may interfere with the circulation of air at the base of the fireplace. 5. Please pull out the power plug when not in use. 6. When switching off the electric fireplace, please turn off all the switches and pull the power plug out of the wall socket. 7. This product is for indoor use only. 8. The fireplace may not work in a wet environment such as in the bathroom or near the washing machine. Please keep the electric fireplace away from water containers. 9. Do not use the fire place if the power cable is damaged, it must be replaced by the manufactur er, a service agent or a similarly qualified person in order to avoid a hazard. 10. Do not lay the wire under a carpet. Do not put rugs, the legs of furniture or other heavy objects on the wire. Keep the wire out of areas of general use. 11. Keep the outlets clear of any material as this may cause electric shock, accidental fire or dam age the fireplace. 12. Due to the possibility of spark generation, do not use the fireplace in areas which store gas, paint and other inflammable and explosive substances. 13. It is prohibited to alter the product in any way. Please use the electric fireplace as per specifi cation. Any other methods that are not recommended by the manufacturer may cause accidental fire, electric shock or physical injury. 14. If you use an extension cable, please use three-core expansion cable with load bearing capac ity under 250V/16A and earth it reliably. 15. If the heating unit becomes overheated, the fireplace will make a warning sound or a warning light will flash. In this case, please turn off the heating unit immediately. 16. Do not burn wood or other materials inside the electric fireplace. 17. Do not hit the glass of the fireplace. 18. Please use the socket with excellent earth, fuse and earth electrode. 19. Please pull out the power plug when cleaning, maintaining or removing the fireplace. 3

Leave a clearance of at least 1cm between the fireplace recess and the surround of the fireplace to ease installation.
The electric fireplace does not need a flue.
Warning 1. The power socket shall be AC230V/15A three-core socket with excellent earth, fuse and earth leakage protection. 2. Note: In order to avoid overheating, do not cover the heater. Do not scrape the plastic off the core of fireplace or install the core directly on a soft surface. Otherwise, it may block the air circulation and cause fire accidents. Install the electric fireplace in dry and safe places free from dust and flammable articles. Please ensure that objects such as curtains not to block the outlet. 3. It is possible that the flames become lower when the heating function is switched on. This can be prevented by placing the surround 10 mm from the wall.
Reminder 1. It is advisable to install the electric fireplace near the socket to ease electric installation. 2. First place the electric fireplace on the selected position to see whether it is satisfactory. 3. This electric fireplace is not allowed to be installed directly onto a wall. Place the mantel in the desired location or build a fireplace recess in the desired location on the floor near the wall. The size of the recess should be:

Specification of The Opening
MF1530H 45.0cm 66.0cm 26.0cm
MF1510H 63.5cm 68.5cm 26.0cm
When placing the fireplace or building the wall structure, please place the insert in dry, safe and clean place.
Model

WARNING Do not install an electric circuit or socket arbitrarily in order to prevent fire accidents, elec tric shock or physical injury. Please ask a professional electrician to install the circuit. 1. Turn off the switch on the core of the fireplace. 2. Insert the power plug into AC230V/15A socket. The cable should be laid along the wall. 3. Pull the core of fireplace into the frame or the wall structure until it parallels with the panel or wall. 4. Finish the installation ensuring that the power plug is accessible after installation. 5. Level the fire by adjusting the feet.

REFILLING WATER 1. When there is no mist, or you hear the water shortage alarm, please refill the water tank imme diately. 2. When the water no longer covers the atomization sheet, atomization stops in 3 seconds and there will be no flame effect. 3. When the atomizer stops, please turn all controls off, unplug the appliance, refill the water tank, plug back in and restart. 4. Fill Water Tank with tap water only. Distilled water must not be used.
A. Take off the log set. Keep in mind that the log-piece has to be removed by holding it with both hands, lifting the right side before lifting it up as a whole. When placing it back, place the left side first and then the right side. Water may leak out of the log set.


B. Take out the water tank. C. Twist off the cap on water tank for water refilling. Before placing it back, carefully check that the watertank is not leaking. Close the cap tightly.
MAINTENANCE Warning Before cleaning and repairing the electric fireplace, please pull out the power plug to pre vent fire accidents, electric shock or physical injury.
Replacing the Bulbs Please clean the top of the lamps regularly (every 150 hours). If areas of artificial flame turn dark, please change the bulbs. There are 5 or 7 halogen bulbs in the electric fireplace under the artificial charcoal, you only need to change the problem bulb.
The halogen bulb used in the fireplace is not a regular type, please contact the sales agent if a bulb requires changing.
Take out the log set and water tank as shown in the images shown on REFILLING WATER Take off the problem light bulb, replace with new light bulb. Please make sure the light bulb is cool before replacement.


Atomizer Cleaning 1. In order to enjoy the optimum visual effect of your mist fireplace it is suggested that you clean the water scale and stain on the atomization unit at least every two to four weeks. (The volume of mist will reduce by no less than 30% after 3000 hours use.) 2. Take out the log set and water tank as the steps show on above images. 3. Take out the distributor as per the following image.

Take out the atomizer and unplug the connector.

head.


REMOTE CONTROL SPECIFICATION I. Remote Controller and Control Panel There are three buttons on the control panels of the remote control and electric fireplace. The buttons with the same characters have the same function.


D
D
A. POWER SWITCH: This is a rocker switch for the mains power of the electric fireplace, the switch is located on the right hand side underneath the log set. B. CONTACT SWITCH: This is a safety switch. When the power switch is placed on I, there will be a tone when you place back the log set. The tone means the unit is well connected, and the product is in standby mode. C. CONTROL PANEL: There are two control panels on both sides. Control Panel on Right: including ON/OFF, LOW, HIGH Control Panel on Left: including DIMMER+ and DIMMER- ON/OFF: power on/off LOW: press this button to have low heating (700W), press again to turn off heating HIGH: press this button to have high heating (1500W), press again to turn off heating DIMMER+ and DIMMER-: flame adjustment, dimmer+ for higher flame effect and dimmer- for lower flame effect D. The opening on both sides are the infrared receivers for the remote control, the signal will be re ceived through the grid to the bump. Do not cover the grid. When using the remote control, please note the left side is for dimmer control and right side is for on/off and heating control, these are the same features as for the manual control panel.

II. Operation of Remote Controller and Control Panel

This fireplace includes a remote controller. Please ensure the remote controller is used with batteries included. The remote controller will not work when it is without batteries or batteries out of power. Please direct the remote controller at the electric fireplace at 1-5 meters distance, otherwise the remote controller could not work properly. Please point the remote controller to the relevant grid for the required functions. Do not cover the receiver on the remote controller.
There is one main power switch on the appliance and four buttons on both control panel and remote controller of the fireplace.
When the cassette version is built in, there is a possibility that you have to hold the remote higher for a good connection with the receiver. A. POWER SWITCH: This is a switch for main power of the electric fireplace, turn the switch to I for power on. Once power is turned on, it comes with a crisp warning tone to warn the operator the power supply has been connected. All the function operations will not start automatically. To turn off the power, turn the switch to O. Remote Control: B. ON/OFF: Push the ON/OFF button once to turn on the internal electric source of fireplace. Meanwhile, the indicator light is on and simulated log set is lit up. Please note it will take about 48 seconds to see the flame effect due to the mist generation process. The heater functions will not turn on unless push the heating buttons. Push the ON/OFF button again to turn off the fireplace. C. DIMMER+ and DIMMER-: Flame adjustment, dimmer+ for higher flame effect and dimmer- for lower flame effect. This unit has the memory function, it keeps the record for last flame adjustment when you use it next time. If you don’t see the flame after 48 seconds, please try to push dimmer+, a few times. D. LOW/HIGH: When the unit is under working condition, push the LOW button once, the heater starts to work at low heating after a warning tone. Push the button again, the heater stops. Push the HIGH button once, the heater starts to work at high heating after a warning tone. Push the button again, the heater stops. When the unit is under low heating, push HIGH button will switch from low heating to high heating. E. Switch off the power if you leave the fireplace for a long time.
Fireplace Surface Cleaning Use a cloth dampened with warm water only to clean painted surface of electric fireplace. Do not use abrasive cleaners.
Service Except bulb replacement, water refill, atomizer cleaning and surface cleaning, all the other clean ings or modification please contact its service agent.