Manuel d'utilisation / d'entretien du produit 2310 du fabricant Vermont Casting
Aller à la page of 28
0898 Vigilant Cover 8/6/01 djt V igilant II Coal Stove Model #2310 Homeowner ’ s Installation and Operating Instructions For Use in North America Do Not Discard This Manual: Retain for Future Use SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T .
2 V er mont Castings V igilant 2000898 W elcome Congratulations on your choice of a V ermont Castings Vigilant II Coal Stove. With this purchase, you have made a commitment to make the hearth a place of warmth, beauty and comfort in your home.
3 V er mont Castings V igilant 2000898 Specifications Vigilant II Coal Stove Model #2310 Coal type ................................ Anthracite or bituminous Coal size ....................................................... Pea or nut Maximum heat output .
4 V er mont Castings V igilant 2000898 Installation Codes and Listings Conforming to local building codes will be an important part of your planning. Local authorities make the final decision on whether or not an installation will be ap- proved. They need to know that your installation is safe and meets local codes.
5 V er mont Castings V igilant 2000898 Weak draft situations are characterized by smoking and odor problems in the house, low heat output, and difficulty maintaining a fire, especially at low thermostat settings.
6 V er mont Castings V igilant 2000898 A B C E D F G H I J H ST562 Chimney hazards 12/14/00 djt ST562 Fig. 6 Existing chimney . D. Blockage within flue; remove. E. Improper clearance between chimney and com- bustible materials. Generally , a clearance of 2” (50 mm.
7 V er mont Castings V igilant 2000898 Clearances Y our stove and chimney connector will radiate energy in all directions when in operation. An important part of planning a safe installation is to be sure combustible materials near your stove do not overheat due to inad- equate clearance.
8 V er mont Castings V igilant 2000898 If the Vigilant is installed in a corner (corner installation) and no shields are used, the corners of the stove must be at least 16” (410 mm) from nearby walls. (Fig. 6) Measure these distances from the edge of the top plate of the stove nearest the wall to the combustible part of the wall.
9 V er mont Castings V igilant 2000898 VIGILANT 24" (610mm) Max. ST687 chimney connector 8/7/01 djt Prefabricated Chimney Single-wall Chimney Connector Chimney Connector Heat Shield Bottom Heat Shield ST687 Fig. 9 Chimney connector heat shields may be used to re- duce clearances when single-wall connectors are used.
10 V er mont Castings V igilant 2000898 V igilant II Clearance Chart Unprotected Surfaces Side Rear Corners Side Rear Corners Stove in Corner Stove Installed Par- allel to W all Stove in Corner Stove .
1 1 V er mont Castings V igilant 2000898 Floor Protection Freestanding Installations A tremendous amount of heat radiates from the bottom plate of a Vigilant Coal Stove, and the floor beneath re- quires special protection.
12 V er mont Castings V igilant 2000898 An unprotected mantel must have a minimum clear- ance of 36”, measured from the stove’s top plate; with a ventilated shield the clearance may safely be reduced to 18”.
13 V er mont Castings V igilant 2000898 Horizontal runs of chimney connectors should slope upward 1/4” per foot going from the stove toward the chimney . The recommended maximum length of a horizontal run is 3 feet. The total length of chimney connector should be no longer than 8 feet to prevent the cooling of flue gases.
14 V er mont Castings V igilant 2000898 Securing the Connector to a Prefabricated Chimney Follow the installation instructions of the chimney manufacturer exactly as you install the chimney .
15 V er mont Castings V igilant 2000898 connector enters the chimney . Follow all the guidelines for installing a chimney connector into a freestanding masonry chimney , and watch these additional points: ST695 Vigilant above fireplace 8/8/01 VIGILANT� Thimble Sleeve Mantel Bottom Heat Shield Damper - closed and locked ST695 Fig.
16 V er mont Castings V igilant 2000898 Operation The Vigilant Controls The Thermostat Lever Adjust the thermostat lever to control the heat level. Move the thermostat lever to the left to make the fire burn hotter . Move it to the right for less heat.
17 V er mont Castings V igilant 2000898 3. Continue building up the fire until there is a thick bed of hot embers on the grates. IMPORT ANT : Don’t hurry this part of the burn. Inad- equate preheating of the chimney system is the most common cause of poor coal stove performance.
18 V er mont Castings V igilant 2000898 Reloading the Stove Put on a small layer of fresh coal and allow it to catch before clearing the grates of ash. Once the new coal is ignited, shake the grates with full, steady strokes of the shaker handle. Stop shaking when red coals cover the ashpan or when you feel resistance.
19 V er mont Castings V igilant 2000898 Maintenance The fire must be out and the stove no longer hot before you work on the stove. We suggest you wear gloves and safety goggles when working on your stove. Cleaning Cast Iron An occasional dusting with a dry rag is usually all that is necessary to keep your Vigilant looking new .
20 V er mont Castings V igilant 2000898 • Select the appropriate gasket. Y our V ermont Cast- ings Authorized Dealer carries a complete line of gaskets. Cut to the recommended length plus a 1” - 2” excess. • Place an unbroken 1/8” bead of gasket cement in the channel or groove.
21 V er mont Castings V igilant 2000898 Because access to the areas behind the side plates and lower fireback is possible through the three clean- out access covers, it usually will not be necessary to remove any other interior parts.
22 V er mont Castings V igilant 2000898 Adjust the Chain Length 1. Make the initial chain adjustment when the stove is cold. With the lever pointing straight up, connect the ball chain to the air intake shutter so the shutter is half open. This setting will work well for most instal- lations.
23 V er mont Castings V igilant 2000898 The Maintenance Guidelines given below will help you develop a schedule that works for you. Once you have developed a maintenance schedule, stick to it. Daily: • Ashes should be removed before the ashes reach the top of the ashpan.
24 V er mont Castings V igilant 2000898 1 48 51 54 53 56 55 47 21 45 44 50 41 40 15 49 20 58 18 17 46 12 1 1 16 13 14 19 10 9 15 2 52 51 3 4 5 6 7 8 22 32 31 62 61 33 34 30 57 59 36 37 38 43 42 39 29 .
25 V er mont Castings V igilant 2000898 V igilant Coal II Model 2310 (continued) Item Description Part Number Item Description Part Number 13. T riangle Firebrick 1600906 14. Right Inner Side 1305002 15. T ie Rod (1) 1601629 T ie Rod Set (4) 5007497 16.
26 V er mont Castings V igilant 2000898.
27 V er mont Castings V igilant 2000898 Limited Three Y ear W arranty CFM Corporation warrants that this Vigilant II Coal Stove will be free of defects in material and work- manship for a period of th.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vermont Casting 2310 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vermont Casting 2310 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vermont Casting 2310, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vermont Casting 2310 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vermont Casting 2310, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vermont Casting 2310.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vermont Casting 2310. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vermont Casting 2310 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.