PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
Copyright ©2003 PSC Inc. An Unpublished Work - All rights reserved. No part of the contents of this documentation or the pro- cedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC"). Owners of PSC products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting PSC Customer Administra- tion. Electronic versions will either be downloadable from the PSC web site (www.pscnet.com) or provided on appropriate media. If you visit our web site and would like to make comments or suggestions about this or other PSC publications, please let us know via the “Contact PSC” page.
Reasonable measures have been taken to ensure that the information included in this manual is complete and accurate. How- ever, PSC reserves the right to change any specification at any time without prior notice.
PSC is a registered trademark of PSC Inc. The PSC logo is a trademark of PSC. All other trademarks and trade names referred to herein are property of their respective owners.
Disclaimer

Section 1. Introduction 1-1 Manual Overview 1-2
How to Use This Manual 1-3
Manual Conventions 1-3 Scanner and Scanning-Scale Nomenclature 1-4
Connectors 1-5 Physical Parameters 1-6
Scanning 1-6 Weighing 1-6
Rated Weight Capacity 1-6 Minimum Increment 1-6 Maximum Static Weight (Overload) 1-6 Automatic Zero Maintenance 1-7 Warm-Up Time 1-7
Thermal Equilibrium 1-7 Power-up 1-7 User Configurable Warm-up 1-7 Electrical Specifications 1-9
Power Supply 1-9 Laser and Product Safety 1-10 Labeling 1-12 Agency Compliances 1-13 Bar Codes Supported 1-14
Section 2. Site Preparation and Installation 2-1 Pre-Installation Considerations 2-2 Checkstand Design 2-3 Scanner Installation 2-4 Scanner Maintenance 2-4 References 2-4 Scanner Usage 2-4 Site Preparation Overview 2-5 Ventilation and Spacing 2-7 Service Access 2-8 Power Installation 2-9

Grounding 2-9 Checkstand Preparation 2-10
Liquid Spills and Moisture 2-11 Counter Cutout 2-11
Checkstand Mounting 2-16 Installation Overview 2-16
Unpacking 2-16 Operational Verification 2-18 Diagnostic Modes 2-20
Scanner Diagnostic Mode 2-20 Scale Diagnostic Mode 2-21 Cables & Connections 2-21 Remote Scale Display Placement/Installation 2-23
Lighting Considerations 2-23 Viewing Angle 2-24 Placing and Installing the Remote Scale Display 2-25 Changing Weighing Modes 2-28 Set-Up & Installation 2-28
Set-up 2-28 Installation 2-30 System Power-Up Recap 2-33
Scanning Items 3-1
Proper Scanning Technique 3-2 Proper Weighing Technique 3-3 Operational Controls 3-4 Operational Modes 3-4
Power-Up/Selftest & Pre-Operation 3-4
Power-Up/Selftest 3-4 Error Reporting 3-5 Operational Configuration 3-5 Operating Mode 3-6
Normal Operation 3-6 Sleep Mode 3-6 Additional Functions 3-7
Programming 3-7

Diagnostic Mode 3-7 Scanner and Scale Reset 3-7 Scale Adjustments 3-8
Zeroing the Scale 3-8 Calibrating the Scale 3-8 Operational Maintenance 3-10
Vertical Scan Window Replacement 3-11 Horizontal Scan Window Replacement (WRG) 3-13
Power-Up Selftest 4-1 Operational Tests 4-1 Diagnostic Tests 4-2 Diagnostic Procedures 4-2 Error Codes 4-3 Scale Error Reporting 4-6 Flowcharts 4-7
Section 5. Calibration 5-1 Description of Calibration Sequence 5-2 Motion Test 5-3 Automatic Zero Setting Test 5-3
Automatic Zeroing if Scale is Under Zero 5-4
Verification of Automatic Zeroing if Scale is Under Zero 5-4 Preparing the Scanner/Scale for Calibration 5-4 Calibrating the Scale (Pounds & Kilograms) 5-5 Calibration Verification (U.S. Pounds) 5-8
Increasing-Load Test (Phase 1) 5-9 Shift Test 5-9 Increasing- Load Test (Phase 2) 5-11 Blanking Test 5-11 Decreasing-Load Test 5-12 Return to Zero Test 5-12 Calibration Verification (Kilograms) 5-13
Increasing-Load Test (Phase 1) 5-13 Shift Test (Metric) 5-14 Increasing- Load Test (Phase 2) 5-15 Blanking Test 5-16

Decreasing-Load Test 5-17 Return to Zero Test 5-17
Section 6. Programming 6-1 Introduction to Label Programming 6-1 Understanding the Basics 6-1 Integrating the Scanner With Your Host System 6-1
Customizing Your Scanner’s Operation 6-2 Programming Overview 6-3
Programming via Handheld Device 6-3 What Is Programming Mode? 6-4 Entering and Exiting Programming Mode 6-4 Programming Session 6-5
Programming Sequence 6-7 LED and Beeper Indicators 6-9 If You Make a Mistake 6-9
Return to Factory Settings 6-9 Test Mode 6-10 General Scanner and Scale Features 6-11
Double Read Timeout 6-11 Laser Timeout 6-13 Motor Timeout 6-15 Green LED Idle State 6-18 Scanner Button Options 6-19 Power-up Beep Control 6-21 Good Read Beep Control 6-23 Good Read Beep Frequency 6-24 Good Read Beep Length 6-26 Good Read Beep Volume 6-27 Good Read When to Indicate 6-30 Scale Enable 6-32 Scale Country Mode 6-33 Scale Enforced Zero Return 6-35 Scale Automatic Zeroing 6-37 Scale Interface Type 6-38 Scale Motion Level Filter 6-40 Scale LED Enable 6-42

Remote Display — Enable/Disable 6-43 EAS Active State 6-44 EAS Timeout 6-45 Aux Port Mode 6-46 Laser Failure Mode 6-48 Productivity Index Reporting (PIR)/Cashier Training (CT) 6-49 Interface Related Features 6-50
Interface Type 6-50
RS-232 Interface Selection 6-52 RS-232 Wincor-Nixdorf Interface Selection 6-53 RS-232 Single Cable Interface Selection 6-54 IBM Port 17 Interface Selection 6-55 IBM USB Interface Selection 6-56 Maximum Host-Transmitted Message Length 6-57 Number of Host Transmission Buffers 6-58 Global Prefix 6-59 Global Suffix 6-61 IBM Features 6-63
IBM Interface Options 6-63 IBM Scale Address 6-64 IBM Transmit Labels in Code 39 Format 6-66 IBM USB Interface Options 6-67 IBM USB Scanner Device Type 6-69 RS-232 Features 6-70
RS-232 Baud Rate 6-70 RS-232 Number of Data Bits 6-74 RS-232 Number of Stop Bits 6-75 RS-232 Parity 6-76 RS-232 Hardware Control 6-78 RS-232 Intercharacter Delay 6-80 RS-232 Software Flow Control 6-81 RS-232 Host Echo 6-82 RS-232 Host Echo Quiet Interval 6-83 RS-232 Ignore Host Commands 6-84 RS-232 TTL 6-85 RS-232 TTL Invert 6-86 RS-232 Beep on ASCII BEL 6-87

RS-232 Beep After Weigh 6-88 RS-232 Beep on Not on File 6-89 RS-232 ACK NAK Enable 6-90 RS-232 ACK Character 6-92 RS-232 NAK Character 6-93 RS-232 Retry on ACK NAK Timeout 6-94 RS-232 ACK NAK Timeout Value 6-95 RS-232 ACK NAK Retry Count 6-96 RS-232 ACK NAK Error Handling 6-97 RS-232 Label ID Control 6-99 Single Cable RS-232 Options 6-101
Single Cable RS-232 Scanner Only Protocol 6-102 Single Cable RS-232 RTS CTS Selection 6-103 Single Cable RS-232 Use BCC 6-106 Single Cable RS-232 Use ACK/NAK 6-107 Single Cable RS-232 Use STX 6-108 Set Single Cable RS-232 STX Character 6-109 Single Cable RS-232 Use ETX 6-110 Set Single Cable RS-232 ETX Character 6-111 Single Cable RS-232 PSC Extensions 6-112 Symbology Programming 6-113 UPC-A Enable 6-113
UPC-A Number System Character Transmission 6-114 UPC-A Check Character Transmission 6-115 Expand UPC-A to EAN-13 6-116 UPC/EAN AIM ID 6-117 UPC-A Label ID 6-118 UPC-A 2-Digit Supplemental Label ID 6-119 UPC-A 5-Digit Supplemental Label ID 6-120 UPC-A 128 Supplemental Label ID 6-121 UPC-E Enable 6-122
UPC-E Number System Character Transmission 6-123 UPC-E Check Character Transmission 6-124 Expand UPC-E to UPC-A 6-125 Expand UPC-E to EAN-13 6-126 UPC-E Label ID 6-127 UPC-E 2-Digit Supplemental Label ID 6-128

UPC-E 5-Digit Supplemental Label ID 6-129 UPC-E 128 Supplemental Label ID 6-130 EAN-13 Enable 6-131
EAN-13 First Character Transmission 6-132 EAN-13 Check Character Transmission 6-133 EAN-13 ISBN Conversion Enable 6-134 EAN 13 Label ID 6-135 EAN-13 2-Digit Supplemental Label ID 6-136 EAN-13 5-Digit Supplemental Label ID 6-137 EAN-13 128 Supplemental Label ID 6-138 Bookland AIM ID 6-139 Bookland Label ID 6-140 EAN-8 Enable 6-141
EAN-8 Check Character Transmission 6-142 Expand EAN-8 to EAN-13 6-143 EAN 8 Label ID 6-144 EAN-8 2-Digit Supplemental Label ID 6-145 EAN-8 5-Digit Supplemental Label ID 6-146 EAN-8 128 Supplemental Label ID 6-147 EAN-8 Decoding Levels 6-148 Other UPC/EAN Options 6-151
UPC/EAN Reconstruction 6-152 Price Weight Check 6-153 Enable EAN Two Label 6-156 Addons 6-157 UPC-A and EAN-13 Decoding Levels 6-159 GTIN Enable 6-162
GTIN Label ID 6-163 GTIN 2-Digit Supplemental Label ID 6-164 GTIN 5-Digit Supplemental Label ID 6-165 GTIN Code 128 Supplemental Label ID 6-166 RSS-14 Enable 6-167
RSS-14 Check Character Transmission 6-168 RSS-14/EAN-128 Emulation 6-169 RSS-14 2D Component Enable 6-170 RSS-14 AIM ID 6-171 RSS-14 Label ID 6-172

RSS Expanded Enable 6-173
RSS Expanded EAN-128 Emulation 6-174 RSS Expanded 2D Component Enable 6-175 RSS Expanded AIM ID 6-176 RSS Expanded Label ID 6-177 RSS Expanded Length Control 6-178 RSS Expanded Maximum Label Length 6-179 RSS Expanded Minimum Label Length 6-180 RSS Expanded Fixed Length 1 6-181 RSS Expanded Fixed Length 2 6-182 Code 39 Enable 6-183
Code 39 Start Stop Character Transmission 6-184 Code 39 Check Character Calculation 6-185 Code 39 Check Character Transmission 6-186 Code 39 Full ASCII 6-187 Code 39 AIM ID 6-188 Code 39 Label ID 6-189 Code 39 Length Control 6-190 Code 39 Maximum Label Length 6-191 Code 39 Minimum Label Length 6-192 Code 39 Fixed Length 1 6-193 Code 39 Fixed Length 2 6-194 Code 39 Stitching 6-195 Pharmacode 39 Enable 6-196
Pharmacode 39 Start Stop Character Transmission 6-197 Pharmacode 39 Check Character Transmission 6-198 Pharmacode 39 Label ID 6-199 Code 128 Enable 6-200
Code 128 Transmit Function Characters 6-201 Convert Code128 to Code 39 6-202 Code 128 AIM ID 6-203 Code 128 Label ID 6-204 Code 128 Length Control 6-205 Code 128 Maximum Label Length 6-206 Code 128 Minimum Label Length 6-207 Code 128 Fixed Length 1 6-208 Code 128 Fixed Length 2 6-209

Code 128 Stitching 6-210 EAN-128 Enable 6-211
EAN 128 AIM ID 6-212 EAN 128 Label ID 6-213 Interleaved 2 of 5 (I 2 OF 5) Enable 6-214
I 2 of 5 Check Character Calculation 6-215 I 2 of 5 Check Character Transmission 6-216 I 2 of 5 AIM ID 6-217 I 2 of 5 Label ID 6-218 I 2 of 5 Length Control 6-219 I 2 of 5 Maximum Label Length 6-220 I 2 of 5 Minimum Label Length 6-221 I 2 of 5 Fixed Length 1 6-222 I 2 of 5 Fixed Length 2 6-223 I 2 of 5 Stitching 6-224 Codabar Enable 6-225
Codabar Start Stop Character Transmission 6-226 Codabar Start Stop Character Set 6-227 Codabar Start Stop Character Match 6-229 Codabar Check Character Calculation 6-230 Codabar Check Character Transmission 6-231 Codabar AIM ID 6-232 Codabar Label ID 6-233 Codabar Length Control 6-234 Codabar Maximum Label Length 6-235 Codabar Minimum Label Length 6-236 Codabar Fixed Length 1 6-237 Codabar Fixed Length 2 6-238 Codabar Stitching 6-239 Code 93 Enable 6-240
Code 93 AIM ID 6-241 Code 93 Label ID 6-242 Code 93 Length Control 6-243 Code 93 Maximum Label Length 6-244 Code 93 Minimum Label Length 6-245 Code 93 Fixed Length 1 6-246 Code 93 Fixed Length 2 6-247

Code 93 Stitching 6-248 MSI/Plessey Enable 6-249
MSI/Plessey Check Character Calculation 6-250 MSI/Plessey Number of Check Characters 6-251 MSI/Plessey Check Character Transmission 6-252 MSI/Plessey AIM ID 6-253 MSI/Plessey Label ID 6-254 MSI/Plessey Length Control 6-255 MSI/Plessey Maximum Label Length 6-256 MSI/Plessey Minimum Label Length 6-257 MSI/Plessey Fixed Length 1 6-258 MSI/Plessey Fixed Length 2 6-259 MSI/Plessey Stitching 6-260 Standard 2 of 5 Enable 6-261
Standard 2 of 5 Check Character Calculation 6-262 Standard 2 of 5 Check Character Transmission 6-263 Standard 2 of 5 AIM ID 6-264 Standard 2 of 5 Label ID 6-265 Standard 2 of 5 Length Control 6-266 Standard 2 of 5 Maximum Label Length 6-267 Standard 2 of 5 Minimum Label Length 6-268 Standard 2 of 5 Fixed Length 1 6-269 Standard 2 of 5 Fixed Length 2 6-270 Standard 2 of 5 Stitching 6-271
Appendix A. LED/Beeper Indications & Controls A-1 Controls and Indicators A-1
Indicator LEDs A-2 Volume/Tone Push Button A-3 Scale Zero Push Button A-5 Calibration Switch A-5
Calibration Switch Seal A-5 Calibration Switch Cover A-6
Appendix B. Cable Information B-1 Introduction B-1
General Specifications B-1
Wire Requirements B-1

RS-232 Cable Pinout B-2
Scanner B-2
Connector Hardware B-2 Scale B-3
Connector Hardware B-3 IBM Cable Pinout B-4
Scanner and Scale B-4
Connector Hardware B-4 IBM USB Cable Pinout B-5
Scanner and Scale B-5
Connector Hardware B-5 Auxiliary Port B-6
External Handheld Input B-6
Connector Hardware B-6 EAS Interlock Connector B-7
Scanner and Scale B-7
Connector Hardware B-7
Appendix D. Host Commands D-1 Accepting Commands from an RS-232 Scanner Host D-1
Appendix F. Handheld Data Format Requirements ........................................................... F-1
Handheld Data Format Requirements General F-1 PSC Handheld Data Format Requirements F-2
RSS-14 F-2 RSS Expanded F-2 UPC-A F-2 UPC-A with 2-Digit Supplemental F-2 UPC-A with 5-Digit Supplemental F-3 UPC-A with Code 128 Supplemental F-3 UPC-E F-3 UPC-E with 2-Digit Supplemental F-4 UPC-E with 5-Digit Supplemental F-4 UPC-E with Code 128 Supplemental F-4

EAN-8 F-5 EAN-8 with 2-Digit Supplemental F-5 EAN-8 with 5-Digit Supplemental F-5 EAN-8 with Code 128 Supplemental F-5 EAN-13 F-6 EAN-13 with 2-Digit Supplemental F-6 EAN-13 with 5-Digit Supplemental F-6 EAN-13 with Code 128 Supplemental F-6 Code 39 F-7 Code 39-Pharmacode F-7 I 2 of 5 F-7 Codabar F-8 Code 128 F-8 MSI/Plessey F-9 Code 93 F-9 PDF417 F-9 AIM Formats F-10
UPC-A F-10 UPC-E F-10 EAN-13 F-10 EAN-8 F-10 2-Digit Supplemental F-11 5-Digit Supplemental F-11 Code 128 Supplemental F-12 Bookland F-12 Code 39 F-12 Codabar F-13 MSI/Plessey F-13 Code 93 F-13 RSS-14 F-13 RSS Expanded F-14 I 2 of 5 F-14 Code 128 / EAN128 F-14 PDF417 F-15

This Product Reference Guide contains comprehensive instructions on how to install the scanner or scanning-scale (either model may be termed “scanner” for the purpose of simplicity in this manual), how to program it using special programming feature bar code labels, and advanced user information as described in the following overview.

Section 1, Introduction, presents the manual’s contents, describes features and specifications, provides regulatory and safety information, and lists the bar code symbologies the scanner will read.
Section 2, Site Preparation and Installation, supplies physical dimensions for the scanner or scanning-scale and its most common accessories, and details counter preparation and installation. Cable routing, connection and testing are also explained in this section.
Section 3, Operation and Maintenance, describes use and maintenance; providing details about operator controls, programming and diagnostic modes, scale “zeroing” and calibration. Scanner and scale routine mainte- nance are outlined in this section as well.
Section 4, Problem Isolation, provides an outline of three scanning-scale test modes: Selftest, Operational Tests and Diagnostic Tests. Descriptions of the error indications if the scanner detects a system problem and trou- bleshooting flowcharts to aid in problem resolution are also presented.
Section 5, Calibration, explains scale calibration and verification proce- dures, including procedures for calibrating the scale in pounds as well as kilograms.
Section 6, Programming, details procedures and provides custom barcodes for setting programmable scanner and scanning-scale features. This sec- tion is organized by the categories: General Features, Interface Related Features and Symbology Related Features.
Appendix A, LED/Beeper Indications & Controls, lists the various functions and indications of the scanning-scale control panel features.
Appendix B, Cable Information, outlines wire requirements, connector specifications and pinout details for associated product cabling.
Appendix C, Keypad, furnishes bar codes representing the digits and char- acters required to enter extended programming data needed during certain programming sessions.
Appendix D, Host Commands, contains a partial listing of available host commands that can be used with a compatible host interface.

You’ll find it helpful to familiarize yourself with the first section of this manual, since it provides both a general description of the product’s fea- tures and an overview of the manual’s contents and organization. Refer- ence the other sections as required for information about scanner or scanning-scale installation, operation, maintenance, calibration and bar code programming.
‘NOTE’ blocks contain information that is helpful and recommended. They provide information that is critical to operations and/or procedures described in this manual.
‘LEGAL NOTE’ blocks indicate procedures or activities which may be regulated under law by governmental agencies. It is your responsibility to ensure compliance with the regulations that gov- ern installation of weighing devices.
‘CAUTION’ blocks inform you that proper handling (adherence to the procedures described) is required to avoid damage to equipment and/or property.
‘WARNING’ blocks alert you to potential physical harm or injury. These statements do not include potentially fatal hazards, which would be desig- nated as ‘DANGER’ blocks. Use of this product does not warrant the need for a DANGER block.

Controls, indicators and other nomenclature are shown in Figure 1-1.
Figure 1-1. Scanning-Scale Nomenclature


The appearance of the connector panel will vary depending upon the fac- tory options purchased with your model. Reference Figure 1-2.
Figure 1-2. Connector Panel
POS Terminal Remote Display Aux. Port EAS Interlock Power Scale Host
POS TERMINAL REMOTE DISPLAY AUXILIARY PORT SCALE HOST EAS INTERLOCK POWER
· Test Port · On Screen Programming (OSP) · Application Download · RS-232 Handheld Scanner Input · Auxiliary RS-232 Label Data Output
Scale Data (dual cable scanner/scale) Drives Remote Display · Label Data · Scale Data (for single cable interfaces) · Application Download (where appropriate)
· Provides Good Read output to enable EAS antenna RF output · Provides signal to drive external speaker
OR Power off Terminal
Dual cable units only. (Scale connection may

This section provides specifications for performance, environmental and electrical parameters. Reference the second section of this manual, Site Preparation and Installation, for physical measurements of all models and some accessories.
The scanner has a scan zone between the two windows where the scanner projects laser light in order to scan items. Two separate projections, one from the horizontal window and one from the vertical window, combine to form a zone where bar code labels are read. Refer to the Operation and Maintenance section of this manual for more details about the topic: Scan- ning Items.
Specifications for scale capacity, settling time, minimum and maximum static weight, zeroing, and warm-up time are given below. For more infor- mation regarding the topic: Proper Weighing Technique, refer to the Opera- tion and Maintenance section of this manual.
) # !*( The scale’s operational weight capacity is:
%% % The minimum weight that can be accurately measured by the scale is 0.02 lb. (0.005 kg).
%%) # + , A maximum static weight of 150 pounds (68 kg) can be sustained by the scale without incurring damage or degrading performance.

.%/ The scale’s software constantly monitors and adjusts the Zero point as long as the deviation is within acceptable limits1, while compensating for any debris accumulation or removal. During power-up, the scale automat- ically re-zeros after verifying that all subsystems are functional. Addition- ally, the scale may be manually “zeroed” by pushing the Scale Zero Push Button located on the top of the vertical enclosure.
There are two pertinent warm-up times that apply to the scanner or scan- ning-scale:
The two warm-up periods can be performed concurrently, thereby reducing the total required warm-up time to 60 minutes.
%012% When the unit is moved from a cooler temperature (such as a storage area) to a warmer environment (such as a checkstand location), 60 minutes must be allowed to acclimate the unit to ambient conditions prior to cali- bration or operation.
* Once installed and powered up, a warm-up time of 15 minutes must be allowed before calibrating or performing weighing operations.
! #2 )%* The user may configure the unit for a pre-programmed warm-up time that is activated every time the scanner is powered up. During this time, the scale is viewed by the POS terminal as off-line.


Contact technical support to learn more about this advanced programmable feature.
Figure 1-3. Environmental Specifications

Temperature 10 to +40 C 50 to +104 F
Hot / Dry 40˚C / 5% RH Cold / Dry 10˚C / 5% RH Warm / Wet 25%C / 50% RH
Temperature -40 to +70 C -40 to +158 F

Before installation, always verify that the site’s electrical service meets the scanning-scale’s requirements. The scanner has been engineered for com- patibility with most international electrical systems operating in ranges from 100 to 240VAC at 50-60 Hz. Verify that the power source will sup- ply “clean” electrical power to the equipment; that is, it must be free of excess electrical noise.
Check the IEC power cord shipped with the scanning-scale. If the cord will not plug into your AC power receptacle, the power cord shipped is not compatible with your electrical system. Please contact your distributor immediately to receive the necessary information and components to ensure electrical compatibility.
The scanner utilizes a single power supply for all models. Unique installa- tion and international connections are accomplished through selection of the proper IEC power cord
VOLTAGE FREQUENCY CURRENT (RMS) PART NUMBER 100-240VAC ±10% 50-60 Hz 0.5 Amps @ 100V 8-0559
Safe operation of your scanner or scanning-scale requires properly grounded electrical outlets. Be sure to have a qualified electrician certify the earth- ground connection on circuits which will be used to power the unit.
The scanner is powered on/off by connecting/disconnecting its AC power supply.

Laser safety requirements are based on IEC Standard Publication 60825-1 (2001) and CDRH 21CFR, Chapter 1, Subchapter J and (CDRH) Laser Product Performance Standard, User information [1040.10(h)1]:
Exposure to the light emitted from the scan windows has been shown not to be harmful. The safety record of bar code scanning is perfect after mil- lions of hours of use worldwide. This safe and efficient use of laser tech- nology has gained wide acceptance in industries throughout the world.
Operators and installers of the unit should observe the following cautions and warnings:
Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.
The use of optical instruments with the scanner will increase eye hazard. (Opti- cal instruments include binoculars, microscopes, telescopes and magnifying glasses. This does not include eyeglasses worn by the user).
To prevent exposure to laser light, do not remove the protective housing of the scanner. There are no user-serviceable parts inside your scanner or scanning- scale.

Safety precautions to be taken:
No adjustments or alteration of the scanner or scanning-scale housing are to be attempted by the user.
The failure of the facet wheel motor while the unit is continuing to emit a laser beam causes the emission levels to exceed those for inherently safe operation. The unit has safeguards to prevent this occurrence. If, however, a stationary laser beam is ever emitted, the failing unit should be disconnected from its power supply until repaired by a qualified technician.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment gener- ates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interfer- ence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe A respecte toute les exigences du Reglement sur le material broilleur du Canada.

Regulatory, reference and safety labeling is shown in Figure 1-4.
Figure 1-4. Labeling
This illustration shows label placement ONLY. For actual regulatory, patent and other applicable information, view the labels on the product itself, or call your nearest sales or service office.
Or...
Max Min e =
min e = III
CAPACITE
CAPACITY

SCANNER/SCALE MODEL XXX PSC CLASS:XXXXXX-XXXXX-XX Manufacture Date: April 200x PSC S/N: XXXXXXXX MAGELLAN 8500 PSC
PSC Scanning, Inc. 959 Terry Street Eugene, Oregon, USA 97402
PSC, Inc. 959 Terry Street Eugene, OR 97402 USA
CLASS 1 LASER PRODUCT LASER KLASSE 1 CATAGORIA 1 PRODUCTO LASER APPAREIL Á LASER DE CLASSE 1 based on 10 sec; IEC 60825-1:2001
THIS LASER PRODUCT COMPLIES WITH 21CFR 1040 AS APPLICABLE AS A CLASS IIA PRODUCT
This Class A digital apparatus complies with Canadian ECES-003. Cet appareil numérique de la Classe A est confirme à la norme NMB-003 du Canada.
N263 Product of USA NRTL
Use ONLY PSC INC. AC/DC Power Supply Input: 50 - 60 Hz (0.5 - 0.25A)
COVERED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 4,709,195 4,709,369 4,712,853 4,749,879 4,786,798 4,792,666 4,798,943 4,799,164 4,816,660 4,861,972 4,861,973 4,866,257 4,868,836 4,879,456 4,963,719 4,991,692 5,144,118 5,179,270 5,198,649 5,247,162 5,229,588 5,410,108 5,459,308 5,440,110 5,475,207 5,493,108 5,705,802 5,723,852 5,834,708 5,929,421 6,059,189 6,237,852 RE37,166 OTHER PATENTS PENDING

The scanner and scanning-scale meets or exceeds the requirements for its device type as set forth by the following agencies and regulations:
Electrical United States UL 1950 TÜV NRTL
Canada CAN/CSA C22.2 No. 1950 TÜV NRTL
World IEC60950 / IEC 825-1:2001 TÜV CB
Australia AS 3260 AS (power adapter)
Emmisions United States 47CFR Part 15J FCC
Canada ICES-0003 Class B
Europe EN 55022 Class B
Australia/N Zealand AS/NZ 3548 Class B
Japan VCCI Class B
Taiwan CNS 13438 Class B
Safety & Emissions EMC Directive 89/336/EEC CE Mark
LV Directive 73/23/EEC CE Mark
Laser Safety United States CDRH, 21CFR Part 1040 CDRH Class IIa laser device
Canada same as CDRH SGM-1 specification
Weights & Measures United States
NIST Handbook 44 (Dept. of Commerce)
New Zealand 1987 Part 1 Reg. 4, Reg. 4A
New York New York Certificate
Contact PSC® Marketing at (541) 683-5700, or your PSC representative for a complete listing of approvals for other countries.

The scanner can read/decode the following bar code types (symbologies):

*
This section provides a reference for preparing most checkstands to receive the scanner or scanning-scale. Included are physical parameters and instructions for checkstand preparation, power and ventilation consider- ations, cable routing information and unit installation.
Site Preparation lists all procedures necessary to prepare the checkstand. The instructions that follow, titled Checkstand Preparation, detail steps for the three models that are available (shown in Figure 2-1 below) to facili- tate easy installation into almost any checkstand application around the world:
Model 8500 — Short Scanner Model 8501 — Long Scanner
Model 8502 — Long Scanning-Scale
Some models are designed to fit with little or no modification into open- ings cut for previously installed scanners such as other PSC® Magellan® scanners, or NCR® scanner models 7820/24 and 7870. Other models are designed for applications with smaller footprint requirements.
Once the procedures in this section are complete, the scanner is ready for operation; with the exception that if a scanning-scale was installed, cali- bration will be required before placing the unit into operation. You must consult the local weights and measures authority to ensure that all legal requirements are met concerning calibration and certification. Section 5, Calibration, contains detailed procedures for calibrating the scale in either pounds or kilograms.

Figure 2-1. The Scanner/Scale Family
Model 8502
!
It should be noted that the scope of this manual does not encompass all factors related to worker safety and checkstand design. It does, however, offer a list of considerations that may be helpful in ensuring greater safety and productivity. Careful planning using these general guidelines should result in a more efficient, comfortable work environment.
The U.S. Bureau of Labor Statistics reports that the incidence of repetitive motion injuries has increased dramatically in recent years. Checkstand design and scanner installation and operation procedures can reduce the risk of repetitive motion injuries, but not eliminate it.
Although there are currently no formal guidelines for checkstand ergo- nomics, the Food Marketing Institute (FMI) and the National Institute of Occupational Safety (NIOSH) of the Department of Health and Human Services have released the reports listed at the end of these recommenda- tions. These reports contain useful suggestions for ergonomic improve- ment of checkstand designs and scanner installation, maintenance and usage. Portions of the reports are summarized below. For copies of the complete reports, or to inquire about any modifications to the recommen- dations, contact FMI and NIOSH at the addresses listed at the end of these recommendations.


Anonymous, 1992, “Ergonomic Improvement of Scanning Checkstand Designs”, Food Marketing Institute 800 Connecticut Ave. N.W. Washington, D.C. 20006
Grant, Katharyn A. et al., 1992, “Ergonomic Evaluation of Checkstand Designs in the Retail Food Industry”, National Institute of Occupational Safety and Health 4676 Columbia Parkway Cincinnati, Ohio 45226
Develop a smooth fluid motion during scanning, sharing work equally between hands.
Use the entire hand for grasping and lifting items.

Since the scanner reads labels on all four sides plus the top and bottom, there is no need to turn a bar code toward either of the scanner windows.
Develop efficient scanning motions, not necessarily faster hand movements. Simply slide the item across the scanner’s horizontal window with as little orientation motion as neces- sary.
Leave items in an upright position; do not lift and tilt.
Learn how the scanner functions and where the scanning area is located.
Do not favor either the vertical or horizontal window; slide items across the scanner in their natural orientations on the checkstand as much as possible. *
Consider the following factors before installing the scanner/scanning-scale and its optional Remote Scale Display.
Ventilation Requirements. The scanner operates without the use of a ventilation fan. As long as there is adequate convective air flow and no major heat producing equipment in close proximity, the unit’s housing provides adequate heat dissipation. The air temperature in the checkstand around the scanner must not exceed 104°F (40°C).
Service Access Requirements. Routine operations such as ‘zeroing’ and calibration do not require removal of the scanner from the checkstand or disassembly of the product. The installer should plan service access for the AC/DC Power Supply and cables.
Recommended Power Installation. Since the typical grocery environ- ment includes conveyor belts and electric motors, care should be taken to ensure that the scanner has a supply of “clean” power (power without excessive electrical noise). A wiring diagram shows the recommended wir- ing that will provide the scanner with a “clean” source of power. Refer to Figure 2-4.

Counter Preparation. Since the majority of grocery checkout lanes are designed as “left-hand take away,” the counter drawings in this section focus on this counter design. Simply reverse the layout for a “right-hand take away” requirement. The unit scans equally well in either of these two configurations.
Liquid Drainage. Should a liquid spill occur, ensure that moisture can flow through the checkstand without pooling.
Leveling. Plan ahead and provide screws/bolts in the checkstand mounts and a leveling guide (board) to allow leveling of the scanner or scanning- scale within the counter. Use a 0.375” thick board to replicate the mount- ing flange on the long scanner or scanning-scale, and adjust screws or bolts until the board is flush within the counter. Use a 4.0” wide board stood on its end to adjust leveling screws/bolts in rail support applications.
Cable Routing. Placement of the scanning-scale should be planned to allow easy access to other components as well as optimize communication between the scanner, the POS terminal and the optional Remote Scale Display. Note that cables may drop straight down from the scanner’s con- nector panel, or may be conveniently routed along the unit’s side using the hardware provided. Do not route interface cables near any electrical motors or other sources of electromagnetic interference.
Remote Scale Display Placement. The customer, and checker in some instances, must be able to easily view and read the Remote Scale Display. Ambient light and mounting height considerations are discussed later in this section.
Vertical Clearance. Provision must be made to allow adequate space above the scanner bonnet for removal and replacement of the All Weighs™ Platter (the L-shaped platter). Optimal clearance permits the platter to be grasped at its top vertical edge and lifted for removal without obstruction (such as a fixed keyboard mount or any type of enclosure). Should such an enclosure be unavoidable, an alternate method of platter removal using two coins may be employed, however a minimum vertical clearance of 1.5” (3.8 cm) MUST be provided (reference Figure 2-2). Another consideration is that the scan zone must be kept free of obstruc- tions such as enclosures, keyboard mounts, etc.

Figure 2-2. Vertical Clearance
DO NOT Obstruct L-Platter Removal
DO NOT Obstruct Scan Zone
Allow a minimum clearance of 1.5" (3.8cm)
The scanning-scale’s perimeter housing has been designed to provide ade- quate space for convective cooling and unrestricted movement of the weighing apparatus. Figure 2-3 shows the debris chutes and ventilation slots. The checkstand design must allow:
DO NOT place the scanner in a close-fitting, fully enclosed checkstand. Pro- vide a MINIMUM of 16 square inches (103.2 square centimeters) of air intake from below the installation for sufficient convective cooling.
If motors, conveyor belts, or other heat producing equipment are located near the scanner, forced air ventilation may be required. In most installa- tions, a 30 cfm (.84 cmm) axial fan should provide sufficient air move- ment. If a ventilation fan is installed, one with a removable filter that may be washed or replaced is recommended.
(Keyboard Mount) · (Enclosure)

Figure 2-3. Debris Chutes & Ventilation Slots
.
The scanner and scanning-scale have been engineered to allow perfor- mance of all routine service and maintenance (such as “zeroing” and cali- bration) without removing the scanner from the checkstand. Additionally all cable connections made at the scanner can be connected and removed while the unit is sitting on the countertop. The installer should provide service access to all remaining cable connectors as well as the AC/DC Power Supply (if installed).

Reference the wiring diagram in Figure 2-4 for the recommended fusing arrangement.
The AC/DC Power Supply should have an AC outlet with a clean earth ground. If you are not sure how to verify the amount of electrical noise (interference) on the power line, ask a qualified electrician to measure the input line voltage.
Figure 2-4. Input Power Wiring
Inductive Loads (e.g. Conveyor Belts, Motors, etc)

Reference Figure 2-5. When performing a first time installation into a new checkstand, verify before cutting that room will be allowed for cabling and the AC/DC Power Supply. When making the opening, take extra care to accurately cut to the correct dimensions. Mounting may require installation of support(s), countertop routing, or other such devices. Depending upon checkstand design, you may wish to install an item diverter to direct items toward the scan window. See the instructions in this manual titled “Counter Cutout” for more details concerning the location and preparation of the opening.
Figure 2-5. Installation Overview
Item Diverter
AC/DC Power Supply
Routed Support
Cabling
Lip
Support Rails

Select a checkstand design which allows fluids to flow through, and directs liquids away from any electronic equipment or storage areas. ! !
The most important consideration when planning the counter opening for the scanner is the operator’s comfortable reaching distance. The ideal, ergonomically sound installation allows items to be directed within easy reach, and a scanning area requiring no lifting or special orientation of items. If you haven’t already read the information at the beginning of this section titled, Pre-Installation Considerations, please do so before continu- ing these instructions.
The symmetrical design of the scanner permits the operator to easily pass items from one hand to the other while scanning (either from right-to-left or left-to-right). With the unique 360- scan zone, scanning is accom- plished in one fluid motion. The operator simply slides the item from the conveyor belt or diverter area through the scanning area and passes the item to the other hand, which in turn bags it or places it on a take-away conveyor belt. Movement should flow naturally over the surface of the scanner.
Figure 2-6 shows a typical “left-hand-take-away” checkstand design.
Follow these basic steps to install the unit:

Interface cables (and display cable, if applicable) should be routed away from all highly inductive electrical devices, like motors and conveyor belts, and even away from the unit’s power cable if possible.
Cables should be easy to remove in the event that replace- ment is required. A little planning now will save a lot of frus- tration later.
The scanner should be installed so that leading and trailing edges of the All Weighs™ Platter are flush with the countertop to enhance smooth, slide-through scanning (reference the insert in Figure 2-6). Keep in mind that the debris chutes on both sides of the platter provide the necessary clearance for proper scale operation if you are installing a scanning-scale (you won’t need to provide an additional gap for that).

Figure 2-6. Typical Checkstand Design & Cutout Location


Refer to the appropriate drawing (Figure 2-7, Model 8500; Figure 2-8, Models 8501 and 8502) for dimensional information on the model you’ll be installing.
Figure 2-7. Model 8500 (Short Scanner) Cutout Dimensions


Figure 2-8. Models 8501 and 8502 Long Scanner or Scanning-Scale Cutout Dimensions

If leveling feet are needed for models 8501 and 8502, use the placement shown here, represented with plus signs (+).

There are a number of things to take into account when installing the unit into a checkstand. Key factors are ergonomic/worker safety, loading capac- ity and stability. Consider the scanner or scanning-scale’s weight when cal- culating the robustness of construction needed to support it as well as maximum capacity of weighed and scanned items.
If you choose to rout a countertop with a thickness of 0.75” (1.9 cm) ply- wood, you’ll need to add a backing strip that supports the area routed out for the support flanges (see Figure 2-5). This support strip should minimally be made of 0.75” (1.9 cm) thick plywood and be approximately 4.0” (10.2 cm) wide and 14.0” (35.6 cm) long. This strip should be glued as well as screwed to the underside of the countertop.
The preceding Site Preparation Overview dealt with installed location and counter preparations to accommodate the scanner or scanning-scale. Hav- ing completed those steps, physical installation of the scanner or scanning- scale can begin. The following instructions apply to all models.
This section describes:
The following text describes each of these steps.
To unpack the unit:

For added protection during shipment, the All Weighs™ Platter is covered with a tight-fitting layer of vinyl as shown in Figure 2-9. This vinyl layer MUST BE REMOVED before placing the unit into service.
Figure 2-9. Remove Protective Vinyl
Protective vinyl MUST be removed
platter before use.
from the

Follow these steps to ensure that your unit has arrived undamaged and is fully functional before installing it in the counter and connecting it to your POS system.
1. If the unit is a scanning-scale, connect the Remote Scale Display to the proper connector on the unit’s connector panel (refer to Figure 2-13). Note that if the Remote Scale Display is not con- nected, a scanner power-up Selftest will sound a long, low beep, and the number “8” will appear on the 7-segment display indicat- ing a remote display error. Power-down, connect a known-good Remote Display to the appropriate port, and restart to correct this problem. Alternatively, you can disable the Remote Display using programming bar codes (see Section 6, Programming for more information).
When power is applied to the unit, the normal indicator sequence is:
Scale calibration may be necessary to obtain a zero reading on the display on rare occasions.
3. The unit should be permitted to reach thermal equilibrium before proceeding to the next steps. (Reference the topic Warm- Up Time in Section 1.) When the unit is moved from a cooler temperature (such as a storage area) to a warmer environment (such as a checkstand location), a period of 60 minutes must be allowed to acclimate the unit to ambient conditions. Once installed and powered up, a “power-up” warm-up period of 15 minutes must be allowed before calibrating or performing weigh- ing operations. These two warm-up periods may run concur- rently.

Scanner. Pass UPC/EAN bar code labels in front of the scanner’s win-
dows. Since the interface cable is not yet connected to the POS terminal, the scanner may be limited to reading only one or two labels (see the note that follows). The scanner indicates when each label has been successfully read by flashing the green scanner light and emitting a good read tone (beep).
When not connected to the host, the scanner may be limited to reading only one or two labels. (This limitation is dependent upon the interface type.) To scan multiple labels without connecting to the host, place the unit in Scanner Diagnostic Mode by pressing the Volume/Tone Push Button for four seconds.
Scale. If the Yellow LED is not lit, press the Scale Zero Push Button
momentarily. If the scale is operating correctly, the yellow LED will illuminate and remain on steady, and the display will show a reading of 0.00 lb (0.000 kg for metric). If the display is blank or a is displayed, it may be necessary to calibrate the scale before continuing. Refer to Section 5, Calibration, for calibration procedures.
Remote Scale Display. Check to verify that 0.00 lb (0.000 kg for met-
ric) is displayed, then place an item on the weighing platter. Ver- ify that the display shows a weight and that the yellow LED goes out. Remove the item and observe that Remote Scale Display shows 0.00 lb (0.000 kg for metric) and that the yellow LED is On.
After you have verified that the scanner and scale (if present) are com- pletely functional, continue with the following procedures to complete the installation.

Two diagnostic modes are available which allow you to initiate scanner or scale diagnostic tests, as well as verify the scanner’s ability to read bar codes.
9# While in Scanner Diagnostic Mode, continuous scanning of labels is allowed, permitting the user to scan an unlimited number of bar codes while troubleshooting problems. Under normal operation, the scanner stores label data, awaiting the signal which transmits it to the host. When the scanner is not connected to a host, it may read and store only up to two labels, then quit reading until power is cycled (clearing the memory). This mode of operation removes this limitation.
To place the scanner in Scanner Diagnostic Mode, press the Volume/Tone Push Button for approximately four seconds. While pressing the button, the scanner will first sound three tones, wait a few seconds, then sound six rapid tones; after which you should immediately release the button.
While in Scanner Diagnostic Mode, identification numbers for interface1 type, firmware and configuration will scroll continually across the scan- ner’s 7-segment FRU (Field Replaceable Unit) display. This is useful infor- mation for field diagnostics. See Figure 4-1 for the location of the display. For example, if the dual cable RS-232 interface (type 05) were enabled, the firmware designation was R96-1234, and the configuration was R96- 5593, the following would be shown (slowly, with blanking between each of the items):
IF-05 r96-1234 r96-5593.
To exit Scanner Diagnostic Mode, cycle power to the unit or press and hold the Volume/Tone Push Button for eight seconds to reset the scanner. See the topic, Scanner and Scale Reset in Section 3 for more information about unit resets.

9# To enter Scale Diagnostic Mode, press the Scale Zero Push Button for approximately four seconds. Six rapid tones will be sounded, indicating the unit is leaving normal operation and entering Scale Diagnostic Mode. The Remote Display will flash a ‘1’ across the display while the dignostic routine is being run. When diagnostics are completed successfully, the dis- play will indicate that the unit has passed the diagnostic test by displaying
. Next, the display shows a listing of how many times the unit has been calibrated and zeroed in the form of: where x equals the number of times the scale has been calibrated. Next, the unit will dis- play where x is the number of times the scale has been zeroed. Finally, all segments will be displayed in the form of: to allow visual verification of display function. If the diagnostics routine is not completed successfully, the scanner will sound a series of tones and the Remote Display will show an error code. Turn to Section 4, Problem Isolation for a description of error codes.
c XXX -18.8.88
Press the Scale Zero Push Button once more to reset the unit and exit Scale Diagnostic Mode. See the topic, Scanner and Scale Reset in Section 3 for more information about unit resets.
Considerations when routing the power and interface cables for the scan- ner and scanning-scale are:
Do not plug the AC power cord into the outlet at this time. It is a good practice to always connect the power cable to the scanner first before plug- ging it into the AC receptacle. The procedures titled, Set-Up, provided later in this section will instruct you to connect the power cord at that time. Figure 2-10 illustrates the basic cable routing scheme.
Zero XXXX

Figure 2-10. Cable Routing
POS Terminal, Printer &
Remote Scale Display Cable
2-22

Figure 2-11 provides physical dimensions for the AC/DC Adapter (part number 8-0599).
2.3" (5.8 cm)
5.51" (14 cm)
3.1" (7.8 cm)
When installing the optional Remote Scale Display, consider both the cus- tomer’s viewing angle and the amount of daily ambient light conditions anticipated at this installation site. Figure 2-12 shows available adjustment for the display head.
The display will be easily readable unless placed in direct sunlight or other very strong light sources. Light interference will not be a factor in most installations.

The optimum viewing angle is directly facing the customer. To ensure that the display is easily readable for the majority of your customers, the dis- play should be approximately 48 to 60” (122 to 152 cm) from the floor.
Check with local Weights and Measures authorities regarding proper posi- tioning of scale displays used in retail trade.
Figure 2-12. Remote Scale Display
CAPACITY / CAPACITE - 30 X .01 lb / 15 x .005 kg 0.00 lb

The connector at the Remote Scale Display end is secured with a rubber band during shipping to prevent damage to the “locking tabs” (see Figure 2-14). After routing the cable, remove this rubber band before the cable end connecting to the Remote Scale Display head. Failure to remove the band will keep the connector from latching properly when it is connected to Remote Scale Display port.
It may be necessary to shorten the stalk that supports the display head so that the display is installed at eye level.

5.6" 14.2 cm
CAPACITY / CAPACITE - 30 X .01 lb / 15 x .005 kg 0.00 lb
2.75" 7.0 cm
1.0" 2.5 cm
5.3" (13.5 cm) Maximum
11.5" (29.2 cm)
3.375" 0.953 cm
1.5" 3.8 cm
4.5" 31.6 cm
Minimum

Figure 2-14. Remote Scale Display Components.
11.5" (29cm)
after rubberband is removed.
Figure 2-15. Remote Scale Display Mounting Template
4 1/2" (11.4 cm)
3 3/8" (8.57 cm)
1 1/2" (3.8 cm)
3/4" (1.9 cm)

Your scanning-scale has been programmed for weighing in either pounds or kilograms depending upon the initial operating environment that was specified when you ordered your scanning-scale. If you need to change from pounds to kilograms or vice-versa, call technical support.
You can verify that the scale is set correctly for your country’s requirements by observing that the Remote Scale Display shows the appropriate mea- surement symbol (lb or kg) when the power-up Selftest is completed.
Any time the scale weighing mode is changed, the scale must be re-calibrated before commercial use. LEGAL NOTE
These setup and installation procedures assume that you have already pre- pared your checkstand to receive the scanner or scanning-scale. If you have not already made the counter cutout and routed power and interface cables, do so now as described in the previous instructions. If your check- stand has been prepared, proceed as follows:
If you have a scanner with no scale, there will be only one interface cable to the POS terminal.

Figure 2-16. Connecting Cables to the Scanner/Scale
POS Terminal Remote Display Aux. Port EAS Interlock Power Scale Host
POS TERMINAL REMOTE DISPLAY AUXILIARY PORT SCALE HOST EAS INTERLOCK POWER
Scale Data (dual cable scanner/scale) Drives Remote Display · Label Data · Scale Data (for single cable interfaces) · Application Download (where appropriate)
· Test Port · On Screen Programming (OSP) · Application Download · RS-232 Handheld Scanner Input · Auxiliary RS-232 Label Data Output
· Provides Good Read output to enable EAS antenna RF output · Provides signal to drive external speaker
OR Power off Terminal
Dual cable units only. (Scale connection may

Figure 2-17. Removing the All Weighs™ Platter
b OR
Vertical Bezel
2-30

Failure to install a scanning-scale in a stable and level position will inhibit weighing, calibration and zeroing operations. The platter MUST make unob- structed contact with all of its supports for proper weighing operation.

Figure 2-18. Using the Lift Handles

The System Power-Up procedure may vary depending upon the require- ments of your POS system. It is generally a good practice to power-down (switch off) all equipment prior to connecting cables. Check with your System Supervisor and/or refer to your POS terminal manual for proper power-down and power-up procedures and interface requirements when connecting any peripheral device.
If you have not identified any specific requirements for your POS system, follow these steps.


*
The information contained in this section describes how to operate and maintain the scanner and scale. Topics include “how to’s” on scanning, weighing, re-zeroing the scale, removing the top cover and cleaning the upper and lower windows.
To scan items using the scanner, slide or push them through the scan zone as shown in Figure 3-1. The scanner will work equally well with either a left-to-right or right-to-left motion through the scan zone. There is no need to reorient an item’s bar code since the scanner can “see” the left, right, front and back side, as well as the top and bottom of an item.

“Limited Scanning Mode” is entered by default by interfaces such as USB and IBM until a Point Of Sale (POS) terminal enables scanning. Labels are “chirped” while in this mode.
Figure 3-1. Scan Zone


* # 1 The scanner was designed to provide the ultimate in ergonomic enhance- ments for Point-Of-Sale (POS) scanning. To take advantage of these advancements:
Practice the techniques below to improve scanning efficiency:

It is important that items rest entirely on the platter for their full weight to be accurately recorded.
Figure 3-2. L-Shaped Platter & Item Placement

The function of scanner and scale controls and indicators is listed in Appendix A, LED/Beeper Indications & Controls. Turn to that appendix for full details. *
The scanner or scanner/scale features a number of modes that are impor- tant to both the user and the system support personnel. These modes can be combined into three groups: pre-operational, operational; and addi- tional functions. The following text describes these modes, what they mean, and how and when they are seen.
Pre-Operation describes those steps that must be successfully completed before the scanner sounds the initial good read tone and illuminates the lamps indicating the scanner and/or scale are ready for operation. These steps include Power-Up Selftest, Error Reporting, and Operational Con- figuration.
*< Power-Up Selftest begins when power is applied. The scanner’s software immediately begins the testing sequence to verify that all systems are func- tioning properly. This routine, which only takes a few seconds, checks all the functions of the scanner, scale, remote scale display and interface prior to indicating that it is ready for operation.
A tone indicating Selftest is complete is a configurable feature. See the topic Power-up Beep Control in the Programming section of this manual.

0 * # If a fatal error is detected during Selftest or operation, the unit will not advance to Normal Operation Mode. Selftest diagnostics will cause the unit to sound a long, low tone and/or display an error message on the 7- segment display indicating where the failure occurred. These messages are coded to assist the repair technician in identifying the failed component. If an error is indicated, make note of it and contact your supervisor or technical support representative. A table containing descriptions of these error codes is included in Section 4, Problem Isolation.
If a non-fatal1 error is detected (such as the loss of one of the two lasers), the unit will sound a long, low tone and display a number on the 7-seg- ment display. The unit will advance to Normal Operating Mode, but per- formance may be affected until a correction or repair is made.
* ! # Once Selftest diagnostics have been successfully run, a tone is emitted (if configured to do so, and the unit enters an operational configuration state. The scanner or scanner/scale will automatically load your specific interface settings which are required to communicate with the host system. There are two conditions that must be met before the unit can enter Operating Mode:
. lb
. kg
display will be seen if there is a weight on the platter at power-up. Removing the weight or pressing the Scale Zero Push Button should allow the scale to find zero.

Operating Mode includes Normal Operation (scanning and weighing) and Sleep Mode. These two modes are most commonly observed by the user/operator.
$%* This condition is indicated by the green light being on dim and steady. For scanner/scale models, the yellow light indicates that the scale senses a weight of zero on the platter. If you have a scanner without scale model, the yellow lamp will not be lit when the scanner is ready for scanning.
Yellow and Green LED indications are configurable. Your scanner may not be pro- grammed to operate in the standard manner described above.
Once the scanner enters Normal Operation, it begins a countdown sequence. If there is no activity during a preset period of time (also called time-out1), the unit will shut off the laser and/or motor in order to pro- long the life of the electrical and mechanical components. Once the scan- ner has timed out, it enters Sleep Mode.
After the scanner has been left idle for a preset period of time, the laser and/or motor automatically turns off (goes to sleep). This state is called Sleep Mode, and is indicated by a “slow” blink of the green light (blinking at a 2-second rate). To wake up the unit, press anywhere on the weigh platter (scanner/scale models only), press the Volume Selection switch or wave your hand in front of the vertical window. The unit will recognize any of these signals as a wake-up call and instantly return to Normal Operation.

Additional scanner and scale functions include programming, running scanner or scale diagnostics, initiating a reset, zeroing the scale, and cali- brating the scale.
When your scanner or scanner/scale is shipped from the factory it is con- figured to work with the POS system interface at your store and read the bar code symbologies you designated. If you need to change this configu- ration information for any reason, Section 6, Programming, contains spe- cial bar code labels for changing the unit’s settings.
Refer to Section 2, Diagnostic Modes for details about running scanner and scale diagnostics. Turn to Section 4, Problem Isolation, for a description of error codes resulting from diagnostics.
The reset procedures and indicators are identical for scanner and scanner/ scale models. As with any electronic equipment, it is sometimes necessary to reset the electronics. The reset procedure allows you to initiate a reset command to the scanner. This may be necessary if the POS terminal has been switched off or the store system has been reset while the unit is on. Reset can also be used to initiate and run the unit’s internal Selftest rou- tine.
Pressing and holding the Volume/Tone Push Button for approximately eight seconds initiates a reset, which is sounded by a rapid number of beeps. If the motor had been spinning, the lamps will blink while the motor spins down. At that point, the motor will spin back up and the scanner will continue to run the Selftest diagnostics. For more informa- tion, see the topic, Power-Up/Selftest & Pre-Operation earlier in this sec- tion.

The scale allows two user adjustments: zeroing and calibration. The first, and most frequently performed, is ‘zeroing’ the scale. This operation resets the scale’s “at rest” reading to zero which must be within the range of - 0.2 pounds (- 1.25 grams) to +0.6 pounds (0.27kg) since the last calibration. While the ‘at rest’ reading remains within the zero range, the scale will automatically adjust itself to true zero. The scale also automatically zeros itself on power-up if the weight present on the scale is within these defined limits.
/ # The zeroing operation may be performed by checkers and other store per- sonnel. Pressing and releasing the Scale Zero Push Button should return the scale to Normal Operation. If the zero point moves out of the zero range due to debris accumulation or other causes, pressing the Scale Zero Push Button will not reset the zero point. In this case the weigh platter must be cleaned, debris chutes cleared of debris or the scale must be recal- ibrated.
With the scanner/scale powered-up and at operating temperature:
!2 # The second adjustment, calibration, defines and sets a standard reference weight range against which all product weights are compared. If your scale is set for weighing in pounds, this range is 0 - 30 pounds, and, if your scale is set for weighing in kilograms, the range is 0 - 15 kilograms. The scale must be calibrated upon initial installation, whenever the scale cannot be zeroed, when the scale diagnostics indicate a calibration error, when the weighing measure (pounds or kilograms) is changed, or when the scale module has been replaced.

Normally, once the scale has been calibrated, the calibration must be veri- fied and/or approved by a local regulatory body. In many areas of the United States, the scale calibration switch must be sealed before being placed into service. Consult the agency responsible for regulating weigh- ing devices in your area to ensure that you are meeting all legal and regula- tory requirements. Section 5, Calibration, describes the calibration sequence and verification process.
Calibration can only be performed if the tamper seal that secures access to the Calibration Switch is broken and the switch cover is removed. Break- ing the seal may legally render the scale inoperable until it has been recerti- fied and a new seal attached. Consult your local regulations before removing the calibration seal if you are unsure of the legal requirements. Although the scale will physically continue to weigh products, a broken seal may require recertification by a proper authority as designated by your local laws.

The scanner or scanner/scale will provide dependable service for many years. The following maintenance procedures will keep your scanner or scanner/scale operating at peak performance.
Cleaning the Weigh Platter and Scan Windows. Clean the exterior sur- faces of the horizontal and vertical scan windows at least twice daily with a nonabrasive, mild, water-based glass cleaner and paper towels or lint-free cleaning tissues. The textured plastic surfaces and stainless steel can also be cleaned using the same cleaning agents.
Cleaning the Air Gap/Debris Chutes & Drip Rail. Daily, clear the debris chutes between the platter and the outer housing. Most items can be cleared from the debris chutes by carefully running a thin stiff object like a credit card along all sides of the weighing surface. If necessary, remove the top cover to clear the debris chutes and drip rail.

The Vertical Scan Window enclosed in the All Weighs™ Platter is a replaceable part. Follow these instructions to remove and replace the win- dow:
To remove the Vertical Scan Window:
Figure 3-3. Platter Removal
b OR
Vertical Bezel
3-11

Use caution to avoid damage to the now exposed horizontal and vertical scan windows. If cleaning of these windows is necessary, use a nonabrasive, mild, water-based glass cleaner and paper towels or lint-free cleaning tis- sues and take care to avoid scratching these windows (damage to the win- dows can degrade scanning performance).
Figure 3-4. Vertical Scan Window Removal/Replacement

Wear Resistant Glass (WRG) horizontal scan windows are replaceable and can be removed and replaced following the instructions below.
Sapphire glass does not require replacement, so it is permanently fastened in place. Do not attempt to remove Sapphire glass from the platter.

Figure 3-5. Removing/Replacing the WRG Window
Slide WRG Window Out

2 %
In the event of a suspected functional problem, use the troubleshooting references provided in this section. This useful information will help you to identify and resolve the cause of the problem.
The scanner/scale has a number of features that indicate when a scanner or scale problem occurs. The unit may:
Three error reporting modes are used: Power-Up Selftest, Operational tests and Diagnostic tests. These test sequences are explained on the fol- lowing pages.
* The Power-up Selftest is a pre-operational series of tests that must be suc- cessfully completed before the scanner indicates readiness for operation. This pre-operational period is the time between power-up and normal operation during which the motor comes up-to-speed and software, firm- ware and hardware are being tested. These tests ensure that all subsystems are fully functional before turning on the Visible Laser Diode (VLD). Refer to the Section 3 subsection titled, Operational Modes for a more detailed description of this and other scanner and scale modes.
* These are the tests that run continually during Normal Operation and Sleep Mode. Firmware checks all subsystems, accessory connections and the POS interface to verify everything is operating normally. If a problem is detected at any time, a long, low tone is sounded, an error code is shown on the 7-segment display, and operation may be halted. If you press the Volume/Tone Push Button at that time, a series of tones will be sounded that matches the error code displayed.

9# See Section 2, Diagnostic Modes, for details about running diagnostic tests for the scanner and/or scale. If a problem is discovered during diagnostics, the scanner will provide feedback about the source of the problem. The remainder of this section describes these failure indications and includes troubleshooting flowcharts to help isolate the problem. 9#
Your Point-Of-Sale (POS) system may contain many components that operate as a system. Since almost all scanner or scale problems are caused by either the scanner, scale, POS terminal or communication links between them, these troubleshooting flowcharts focus on these compo- nents. Additionally, the optional Remote Scale Display, AC/DC Power Supply and their cables are potential problems addressed in this section.
The flowcharts provided in this section walk you through a diagnostic process that will isolate the failed component and instruct as to the correc- tive action required. Since internal scanner and scale components cannot be replaced by an operator or installer, most functional errors will require the assistance of a trained technical support person. However, if the prob- lem is caused by faulty cable, power supply or remote display, you can fix the problem by replacing the defective component and complete the installation.

If an error is detected, the scanner will sound a long low tone (for three seconds) and alternately flash its LEDs, indicating a failure. When this occurs, press the Volume/Tone Push button to display the error code on the 7-segment display (refer to Figure 4-1). If it is configured to do so, the scanner will also sound a series of beeps corresponding to the error code. The table below describes what these codes mean and what action should be taken for each.
When troubleshooting, always remember to check all cable connections first before proceeding with other problem isolation steps.

2 "@0! ! .
Error Code Probable Cause Corrective Action
No POS interface has been selected (Null interface). See the topic, Interface Type, in Section 6 to select the required interface using programming bar codes.
1 Configuration Error See Section 6, Programming, for details about configuring the scan- ner using programming bar codes.
2 Interface Board Unplug unit and call technical support personnel.
3 Motor Unplug unit and call technical support personnel.
4 Horizontal Lasera Call technical support personnel.
5 Vertical Lasera Call technical support personnel.
6 Digital Board Unplug unit and call technical support personnel.
7 Scale See the topic Scale Error Reporting in this section for problem identification and corrective actions.
Connect the Remote Display. If necessary, replace display or cable. Alternatively, you can disable the Remote Display using the program- ming procedures described in Section 6.
A Button Module Call technical support personnel.
C Scale Calibration Proceed to scale calibration procedure.
Decimal Point 3.3 V Present If not lit, call technical support personnel.
a. If only one laser is non-functional, the scanner may continue to work (this is a configurable feature);
however, the 7-segment display will show the error code indicating the failed laser. If both lasers have failed, the 7-segment display will display either a 4 or a 5, and the scanner will cease to function until serviced. No alternate blinking of lamps will occur if only one laser has failed.
0 Blinking Configuration · 8 Remote Display

Figure 4-1. 7-Segment LED Display

Scale diagnostics uses the Remote Scale Display and the Zero Status lamp to communicate specific scale failures. The following chart shows the Remote Display messages, the Scale Status lamp indication, the problem that the scale is experiencing and what action should be taken. When troubleshooting, always remember to check all cable connections first before proceeding with other problem isolation steps.
2 "@ 0 * #
Problem Description Action Required
Check for stable installation. Change scale motion filter using the labels found in Section 6; restart. If problem persists, scale may require calibration.
Flash, pause, 1 blink, long pause, repeat sequence.
Too much motion at power- up.
Flash, pause, 2 blinks, long pause, repeat sequence.
Calibration lost. Call technical support personnel. Re- calibrate; restart; recertify (if required).
Flash, pause, 3 blinks, long pause, repeat sequence.
Scale communication lost. Internal scanner/scale prob- lem.
Call technical support personnel; report error.
Flash, pause, 4 blinks, long pause, repeat sequence.
Scale module failure. Call technical support personnel; report error.
Flash, pause, 5 blinks, long pause, repeat sequence.
Internal software fault. Call technical support personnel; report error.
- Check debris chutes. - Verify that the weigh platter moves freely. - Remove item(s) from scale - Press Scale Zero Push Button - for more information. - If the scale still fails to zero, recali- brate the scale.
Cannot zero at power- up or weight remains on scale for more than 4 minutes or weight has not returned to zero between POS weight requestsa.
- 0 - Off
a. This is a configurable feature.

The problem isolation flowcharts on the following pages allow you to identify and troubleshoot problems with your system.
For units using an AC/DC adapter, verify that... 1. AC power cord is connected to a functional AC outlet. 2. IEC connectors are firmly connected. 3. DC power cord is firmly connected to scanner.
If your unit is a model which receives Power Off the Terminal POT), verify that the I/F cable is securely connected at both ends.
Power-up Scanner power-up is signified by any or all of the following: - Facet wheel shows movement - Lasers turn on - Status LED(s) turn on - Speaker sounds tone(s) - Remote display shows message - A single red dot is visible on the 7- segment display
Have you checked the
NO Does the scanner
Flashing Green LED If the Green LED is flashing slowly, the scanner is most likely in Sleep Mode. Press and release the Volume/Tone Push Button or wave your hand in front of the vertical window to "wake-up" the scanner. A flashing Green LED can also mean the scanner has been disabled by the POS terminal. To exit this mode, cycle power or have the terminal re-enable the scanner.
NO Is the Green LED
Ensure the Green LED is enabled via pro- gramming bar codes.
NO Is the Green LED
YES
Selftest Failure If the scanner fails its Selftest, the following takes place: - Speaker sounds a tone at the lowest value for approx. 3 seconds. - Green and Yellow LEDs flash on and off alternately. - 7-segment display shows a code (1 to C) to indicate the failure.
NO Does the scanner pass Selftest
Go to Selftest flowchart
Consult the Selftest flowchart if you're unsure the unit has passed Selftest.
YES NO NO Will the scanner read
Does the scale weigh
Go to Scale flowchart
Go to Poor/No Reading flowchart
Other Problems? Call Tech Support

START
Scan the Factory Defaults bar code in Section 6 to enable the default configuration file. Restart the unit.
NO Does the 7-segment display show
Does the 7-segment display show
Does the 7-segment display show
YES
No interface selected (Null Interface). Select an interface.
YES Does the 7-segment display show
Error code 4. indicates a failed horizontal VLDM (laser) assembly, while 5. indicates a failed vertical VLDM. If configured to do so1, the scanner will remain operational with only one of these lasers until the unit can be serviced. If both lasers have failed, the unit will no longer function.
YES Does the 7-segment display show
YES Does the 7-segment display show
7 or A. ?
YES Does the 7-segment display show
Go to Remote Display flowchart
For this error, the Remote Display may also show -0- or an error (E__#).
Does the 7-segment display show
Go to Scale flowchart
1 Refer to the feature Laser Failure Mode in Section 6.

Have you verified that all scan windows are clean
Before proceeding, verify that bar code samples presented to scanner are of good quality and a symbology the scanner can read.
Enter Scanner Diagnostic Mode by holding the Volume/Tone Push Button for 4 seconds (until first 3, and then 6 rapid tones are sounded) then release. Scan a known-good bar code.
A good read is signified by one flash of the Green LED and a single beep1.
NO Does the scanner read
the bar code satisfactorily
Reset the scanner by holding down the Volume/Tone Push Button for 8 seconds.
If unexpected data is being sent from the host to the scanner, consider enabling the programmable feature Ignore Host Commands to debug the system.
Does the scanner pass
Does the scanner read
YES
DONE
NO
NO
Go to No Transmit to POS flowchart
Verify programmable parameters using the information and programming bar codes provided in Section 6. Check bar code symbology options and other configurable features.
Does the scanner read
DONE
NO
Troubleshoot the host or call Tech Support.
Green and Yellow LEDs and beeper indications are configurable features. Behavior may vary from that described here. 1

START
Check the interface (I/F) cable connections. If possible, retest the system using a known- good I/F cable.
Verify programmable parameters using the information and programming bar codes provided in Section 6. Check interface and I/F options, inactive symbologies and other configurable features.
Does the scanner read
DONE
NO
NO Does the scanner pass
Troubleshoot the host or call Tech Support.
DONE
4-10

If this is a new installation, make sure any foam packing pieces have been removed from the scale cavity before proceeding. Lift off the platter to verify, then set the platter back into position.
View the Remote Display and/or the Yellow scale status LED for the scale error code. Reference the topic, Scale Error Reporting in Section 4 for more information.
Is the motion filter at its maximum
DONE
YES -0- shown on RemoteDisplay/
- Check for debris under platter. - Verify that the weigh platter moves freely. - Remove item(s) from scale. - Press Scale Zero Button - If the scale still fails to zero, recalibrate the scale. NO
Increase the scale motion filter setting by 1. Reference Section 6 for more information.
E__1 shown on Remote Display/
Problem is too much motion at power-up. Correct excess vibration in counter if possible.
DONE
NO
NO
E__2 shown on Remote Display/
Problem is calibration lost. Recalibrate the scale using the procedures in Section 5.
DONE
NO
For this error, the 7-segment display may also show a 'C'.
YES E__3 shown on RemoteDisplay/ Yellow LED Flash
Problem is scale communication lost. Verify cable connections to/from the scale.
NO
NO
E__4 shown on Remote Display/Yellow LED Flash 4 times. Problem is Scale Load Cell failure.

Scanner-scale models that include a Remote Display when shipped from the factory, are configured for use with the display. If you're unsure of the settings for your unit, contact Tech Support.
Is the unit configured
Use the programming bar codes in Section 6 to enable operation using a Remote Display.
YES
Verify that the Remote Display cable is securely attached to the external Remote Display port and reset the scanner.
YES
DONE
Re-connect using a known-good Remote Display. Reset the scanner and retest.
YES
Replace the Remote Display
NO
DONE
4-12

!2
A number of situations require the scale to be calibrated. They are:
Follow the procedures on the following pages to ensure that the scanner/ scale will meet Weights and Measurement requirements.
Certification of the scanner/scale’s weighing apparatus is subject to Federal, State and Local Weights and Measures statutes and is restricted to authorized government agencies and/or duly registered agents thereof. Anytime a scale is calibrated, it should be properly sealed with a lead and wire or paper seal before being placed into ser- vice.
It is your responsibility to check with the appropriate authorities in your area to ensure compliance with pertinent regulations before removing any official seals or placing a newly calibrated scanner/scale into service.

The Calibration Sequence sets the scale to an accurate reference point for weighing. This process involves the use of a Field Standard Weight Set (31.5-pounds) for calibration in pounds, (18.5-kilograms) for Metric. Once calibration has been successfully completed, the scanner/scale uses the certified weight as a reference for subsequent weighing activities.
These verification procedures follow the U.S. National Institute of Stan- dards and Technology 44 Handbook guidelines for bench/counter scale installations.
If any of these tests fail to meet the required weight indications, you must calibrate the scanner/scale. Refer to the calibration procedures in this sec- tion for the proper procedures.
You may be required by state and/or local regulations to have procedures other than these performed by a certified technician or verification offi- cial.
Access to the calibration switch should be restricted with a paper or a wire and lead seal after the calibration has been performed if required by your local regulatory agency.
The Calibration Sequence must be performed without removing the scanner/ scale from its installed position.
The following tools and supplies will be required to perform the calibra- tion process:

This test verifies that the scale will not ‘zero’ when the weighing surface of the scanner/scale is in motion.
This test verifies that the scanner/scale automatic zero setting mechanism is operating correctly.
The scanner/scale has an adaptive zero capture mechanism that re-zeros the scale over time if there is a slow change in the zero level; thus if all the weight is not placed on the weighing surface at one time, the Yellow LED will remain On and the Remote Display will read 0.00 pounds (0.000 kilograms). When the weight is removed, the Yellow LED will turn off and the display will
show a minus sign . Press the Zero Push Button to re-zero the scale.
. lb

The scanner/scale is equipped with a feature that automatically zeros the scale if it has been under zero for five seconds. (See “Scale Automatic Zeroing” on page 37.) Local requirements may require temporarily dis- abling this feature during certification. For the most accurate weighing function, it is recommended that the automatic zeroing feature be enabled.
: .%/ # /
0.00lb 0.00kg
then, after five seconds, the display should read (or kg). * # < !2
0.00lb
lb

To protect static sensitive circuitry, follow Electro-Static Discharge (ESD) pro- cedures when exposing internal scanner-scale components.

the Field Standard Weight set on the center of the weighing area and press the Zero Push Button again.
until the scale is ready to proceed.
You have completed the scale calibration procedure. You must now con- tinue with the calibration verification tests to complete the scale’s calibra- tion. If you are weighing in pounds, continue with the following procedures to verify that the scale was successfully calibrated and that it weighs properly. If you are weighing in kilograms, turn to the instructions titled, Calibration Verification (Kilograms), later in this section.

Figure 5-1. Calibration Access Cover
Figure 5-2. Calibration Switch

Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
These calibration verification procedures cover five different tests:

This test checks Scale operation with five, ten and fifteen pound weights.
The Shift Test checks to ensure that items placed anywhere on the weigh- ing surface of the scanner/scale are weighed properly. Refer to Figure 5-3 when performing this test.

Figure 5-3. Shift Test
A C B
D
D

After completing the Shift Test, you must complete the Increasing Load Test using 20.0, 25.0 and 30.0 pounds of weight.
The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 30 pounds, which is the standard setting. For this test, continue to place weights in five pound increments only up to the upper weight limit set for your scale.
This test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater than 0.05 pounds over its maximum upper weight limit is placed upon the unit.
The scanner/scale may blank (show an underscore and three hyphens) at any weight greater than its upper limit, but must blank when the upper limit plus 0.051 pounds are set upon the weighing surface.

This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object.
If the upper weight limit for your scale is not set at 30 pounds, begin by plac- ing weight equaling your upper limit setting.
This test ensures that, after all other tests have been completed success- fully, the scanner/scale returns to zero. Remove all weights from the scale and verify that the scale reads 0.00 lb.
After completing this test, close the calibration access cover and seal per local Weights and Measures requirements. This final step must agree with the legal requirements of your state or local government.
You have completed the calibration and verification process for weighing in pounds.
If the scanner/scale passes all these tests,
If the scanner/scale fails any of these tests, it should be serviced by a quali- fied technician.

Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
These calibration verification procedures cover five different tests:
This test checks Scale operation for increasing loads from 0.100 kg and 7.50 kg.

The Shift Test checks to ensure that items placed anywhere on the weigh- ing surface of the scanner/scale are weighed properly. Refer to Figure 5-4 when performing this test.

Figure 5-4. European Shift Test (Metric)
C D
B
A
D
CENTER
#6 + ,
After completing the Shift Test, you must complete the Increasing Load Test using 10.00, 12.50 and 15 kilograms of weight.
The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 15 kilograms, which is the standard set- ting. For this test, continue to place weights in 2.50 kilgram increments only up to the upper weight limit set for your scale.

This test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater than 0.82 over its maximum upper weight limit is placed upon the unit.
The scanner/scale may blank (show an underscore and three hyphens) at any weight greater than its upper limit, but must blank when the upper limit plus 0.82 pounds are set upon the weighing surface.

This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object.
If the upper weight limit for your scale is not set at 15 kilograms, begin by placing weight equaling your upper limit setting plus 0.8 kilograms.
This test ensures that, after all other tests have been completed success- fully, the scanner/scale returns to zero. Without any weight on the weigh platter, verify that the scale reads 0.000 kg.
You have completed the calibration and verification process for weighing in kilograms.
If the scanner/scale passes all these tests,
If the scanner/scale fails any of these tests, it should be serviced by a quali- fied technician.


#%% #
The programming bar code labels contained in this manual will allow you to customize and configure features and settings for your scanner (scan- ner/scale). To ensure full compatibility and proper function, use only the programming bar codes in this manual and other product-specific publi- cations to program scanner features.
This manual has been developed to make it quick and easy for users of all levels to find the information needed to understand and configure fea- tures. The following descriptions will help you to determine where to go from here. # 7
If you have little or no prior experience with programming using bar code labels, you should review the first few pages of this section to familiarize yourself with the basics of scanner programming before performing any changes to your configuration. # # ) B ( %
Your scanner MUST be equipped with the correct hardware (interface board, cable, etc.) to properly communicate with your host system. Con- tact your dealer for information if you have questions about your scanner’s hardware compatibility.
You may also want to contact the dealer or your system administrator if you have no record of how your scanner was pre-programmed at the fac- tory. Scanners are typically programmed with the default settings for spe- cific interface types (see Appendix E, Factory Defaults for more information); however, your scanner may have been custom configured with settings that are unique to your company or application.

Once you know the scanner’s current settings, you can determine what changes will be required to allow communication with your host system and/or optional features you choose to modify to customize your installa- tion. After recording the modifications needed, finish reading this section, then turn to the appropriate page and follow the instructions to program the scanner.
When all scanner features are programmed to your satisfaction, the scan- ner is ready to be placed into operation.
Most scanner programming falls within three general categories:
It is possible, via programming bar codes, to change the interface type (for example: from RS-232 to IBM Port 17). Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Ensure that your planned modifications are compatible with the current inter- face. For example, baud rate selections are only valid in the RS-232 interface. The scanner will sound an error tone when scanning programming labels for features invalid to the current interface group.

If you experience difficulties, have questions or require additional infor- mation, contact your local distributor, or call your dealer or sales represen- tative. #%% #
The scanner’s programmable feature settings can be modified to accom- modate your system’s unique requirements. These settings can be commu- nicated to the scanner in one of two ways:
When you program the scanner using any of the methods above, the scan- ner will store the changes until reprogrammed or returned to factory defaults.
The scanner can also accept programming via its auxiliary port using a handheld scanning device. Eligible handheld devices must have the ability to transmit Code 128 function codes such as the programming bar codes presented in this manual. PSC models QuickScan® 1000 and Quick- Scan® 6000 support this functionality. Handheld data format require- ments (baud rate, parity, etc.) are presented in Appendix F of this manual. Additionally the programmable feature, Aux Port Mode, must be set to “External Handheld Input” to allow operation.

Programming Mode is a state in which the scanner must be placed in order to accept commands via programming bar code labels. When pro- gramming using the bar code labels in this manual, the scanner is typically placed in Programming Mode by scanning the SWITCH label.
While in the Programming Mode, the scanner only recognizes the special programming bar codes contained in this programming guide. See Appendix A for information about scanner indications while in the Pro- gramming Mode.
Use the bar code label below to enter and exit (‘switch” into and out of) Programming Mode.
6-4

A typical programming session is conducted as follows:
Not all features are available for all interfaces and the scanner will sound an error tone when scanning programming bar codes for features invalid to the current interface. Only features supported by the currently active interface will be implemented.
If a bar code is scanned that changes the scanner’s interface, all previous configuration items scanned in the programming session are lost.
Additionally, when programming a feature requiring you to scan single digits to set a multi-digit number, such as Minimum Label Length, scan- ning the SWITCH bar code (or any item tag/item value bar code) before completing all input will result in an error tone and cause the scanner to exit Programming Mode. Under these circumstances, the current feature you were trying to set is thrown out; any previous bar codes scanned dur- ing the session will take effect.

It is recommended that programming sessions be limited to one feature at a time. Should you make a mistake in the programming sequence, it can be difficult to discover where an error has been made if several fea- tures are programmed at once. Additionally, it can be confusing to deter- mine which features may or may not have been successfully set following such a session.
The scanner will exit Programming Mode under the following conditions:
— the programming sequence has been completed or the
SWITCH bar code is scanned
— five minutes have passed without scanning activity. Any data
programmed during the current session will be ignored1, and the scanner will reset and revert to its condition previous to initiating the exited session.
— power is disconnected. Disconnecting power during Pro-
gramming Mode, before scanning the SWITCH bar code, will cause all new settings to be ignored. On power-up, the scanner will return to previous settings.

#%% # 1 To modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 6-1). There are three possi- ble programming sequences:
If the scanner’s interface type must be changed, always be sure that inter- face configuration is the FIRST item scanned during a programming ses- sion. (Selecting an interface type resets ALL other configuration items to the factory default for that interface type.)
A. Programming sample A (the most commonly used format) dem-
onstrates how three bar codes are scanned in sequence to do the following:
B. Sample B provides an example of a programming feature requir-
ing the entry of a range value. Like sample A, the scanner is placed in Programming Mode and an Item Tag1 is scanned. Then, a value must be entered before ending the programming session. In the example, three digits must be scanned from the number pad in Appendix C. This type of format, requiring several bar codes, is necessary to allow flexible programming for item val- ues with larger numeric ranges.
C. The programming sequence shown in example C requires scan-
ning of a single, extended length bar code. This special program- ming bar code contains all the data necessary to enter Programming Mode, set the Item Tag1 and Item Value, and exit Programming Mode (all in one step).

2 '@#%% # 1

ONE BAR CODE CONTAINS SWITCH + ITEM TAG + ITEM VALUE + SWITCH

The scanner provides a set of indicators that verify/announce the various scanner functions.
If, during a programming session, you find that you are unsure of the scanner’s settings or wish to reset the scanner’s configuration, use the Return to Factory Settings label below to return the scanner’s configura- tion to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
Scan this bar code to return the scanner to the default settings configured at the factory for the currently active interface. This bar code is typically used to return the scanner to a “known” operating state when the present programming status is not known, faulty, or suspect.

Use this bar code with caution, since it will reset ALL features that may have been programmed since the scanner’s installation.
DO NOT scan the SWITCH bar code before and after scanning this bar code.
6-9

Use this feature to place the scanner into a testing, or “demo” mode. This special mode disables the scanner interface, meaning that bar code data is not sent out to the host via the scanner interface. This allows the bar code to be scanned continuously without requiring a response from the POS terminal.
To return the scanner to normal function, scan the TEST MODE = DIS- ABLE bar code below.

DO NOT scan the SWITCH bar code before and after scanning the bar codes on this page.
Scanning the TEST MODE = DISABLE bar code sets the Double Read Timeout to 600ms.
TEST MODE = ENABLE
6-10

The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identi- cal items in succession).
To set the Double Read Timeout:

If the incidence of multiple reads is not acceptable, increase the Double Read Timeout setting to a higher value.
DOUBLE READ TIMEOUT = 400ms
DOUBLE READ TIMEOUT = 600ms

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
DOUBLE READ TIMEOUT = 800ms
6-12

The laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. Using this feature can prolong the life of the VLDs.
To set the Laser Timeout:
6-13

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
LASER TIMEOUT = 15 MINUTES
6-14

The Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use.
Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the motor and the laser will both shut off when the motor timeout expires.
To set the Motor Timeout:
6-15

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
MOTOR TIMEOUT = 15 MINUTES
6-16

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
MOTOR TIMEOUT = 60 MINUTES
6-17

This feature specifies the state of the green scanner LED when the scanner is idle and ready to read a label. Options are:
To set the LED Idle State:
GREEN LED IDLE STATE = ON DIM
6-18

Configure the scanner volume button to one of the following modes of operation:
To set the desired Scanner Button Option:
SCANNER BUTTON OPTION = ENABLE ONLY VOLUME/TONE/RESET
6-19

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
SCANNER BUTTON OPTION = DISABLE ALL BUTTON FUNCTIONS
6-20

Specifies the type of audible indication that is made when entering scan- ner-active mode on power-up. Choices are:
To set the Power-up Beep:
6-21

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
POWER-UP BEEP = THREE BEEPS
6-22

This feature enables/disables scanner beep upon successfully decoding of a label.
GOOD READ BEEP = ENABLE
6-23

Adjusts the scanner’s good read beep to sound at low, medium, or high fre- quency (controls the beeper’s pitch/tone).
To set the Good Read Beep Frequency:
6-24

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GOOD READ BEEP FREQUENCY = HIGH
6-25

Specifies the duration of a good read beep.
To set the good read beep length:
250 = 2,500ms (2.5 seconds)
6-26
001 = 10ms · 005 = 50ms · 040 = 400ms

Selects the beeper volume upon a good read beep. There are five selectable volumes, with each volume increment adding approximately five decibels to the previous level:
To set the Good Read Beep Volume:
6-27

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GOOD READ BEEP VOLUME = MEDIUM
6-28

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GOOD READ BEEP VOLUME = HIGHEST
6-29

This feature specifies when the scanner will provide indication (beep and/ or flash its green LED) upon successfully reading a bar code.
The “Indicate after CTS goes inactive...” mode applies to RS-232 STD and RS-232 WN interfaces only. If set to this mode in other interfaces, “Indicate after decode” mode will be implemented.
To set the Good Read When to Indicate feature:
6-30

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GOOD READ = INDICATE AFTER CTS GOES INACTIVE, THEN ACTIVE
6-31

Use this feature to enable or disable scale operation.

Recalibration/recertification may be required when adding scale functional- ity. Consult your local Weights and Measures authority.
If this feature is enabled the scanner will expect that it is to function as a scanner-scale, and will indicate an error if it is not a scale-equipped unit. See Error Codes in Section 4 for more information.
SCALE = ENABLE
6-32

When a weight is presented, the scanner/scale will apply the country-spe- cific weighing rules specified via this feature.

Scale Country Mode applies only when a scale is enabled.
SCALE COUNTRY MODE = U.S.A.
SCALE COUNTRY MODE = U.K.

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
6-34

This feature enables/disables the enforced zero return of the scale. Three settings are available for this feature:
6-35

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
SCALE ENFORCED ZERO RETURN = SCALE MUST RETURN TO ZERO WEIGHT
SCALE ENFORCED ZERO RETURN = SCALE MUST RETURN TO ZERO WEIGHT
6-36

This feature enables/disables automatic zeroing of the scale if it goes under zero. If an under-zero condition is detected and persists for at least five seconds, the scale will be zeroed as it the zero button had been pressed. This feature ensures accurate weighing by automatically zeroing after under-zero conditions are detected, such as after the platter has been cleared.
SCALE AUTOMATIC ZEROING = ENABLE
6-37

Use this feature to select the scale interface type for RS-232 Standard and RS-232 Wincor/Nixdorf POS interfaces. Choices are:
To set the Scale Interface Type:
SCALE INTERFACE TYPE = RS-232 — SASI
6-38

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
6-39

In environments where checkstands generate excessive vibration, the scale can be set to filter a certain amount of the motion with regard to its oper- ation.

This filter is generally used only in applications where scale error E_1 (too much motion at power-up) has occurred.
SCALE MOTION LEVEL FILTER = MEDIUM LOW
6-40

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
SCALE MOTION LEVEL FILTER = HIGH
6-41

This feature enables/disables Scale LED (Yellow LED) operation.
SCALE LED = ENABLE
6-42

The scanner-scale can be configured to operate with or without a Remote Display.

Recalibration/recertification may be required when adding a Remote Display. Consult your local Weights and Measures authority.
If this feature is enabled the scanner-scale will expect that it is connected to a Remote Display, and will indicate an error if one is not. See Error Codes in Section 4 for more information.
REMOTE DISPLAY = ENABLE
6-43

Specifies the active state polarity of EAS (Electronic Article Survellance); the inactive state is its opposite polarity. EAS output goes active during the good read of a bar code, allowing the EAS device to deactivate a tag on the product.
To set the EAS Active State:
EAS ACTIVE STATE = ACTIVE HIGH
6-44

Specifies the amount of time that an EAS (Electronic Article Survellance) signal is held in its active state for a good read.
To set the EAS Timeout:
000 = EAS timeout disabled
250 = 2,500ms (2.5 seconds)
A setting of 0 (000) disables this feature.
6-45
001 = 10ms · 005 = 50ms · 040 = 400ms

Selects the usage for the scanner’s optional auxiliary port. The choices listed below are mutually exclusive (only one option can be active at a time).
Cable pinout information for the Aux Port is provided in Appendix B of this manual. A connected handheld scanner must be configured to transmit data as outlined in Appendix F.
6-46

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
AUX PORT MODE = PIR/CT
6-47

This configuration item selects whether the scanner should continue oper- ating if only one laser is functional. (The scanner has two lasers: One for the horizontal window, and one for the vertical window.) Options for this feature are:
LASER FAILURE MODE = SINGLE LASER FAILURE FATAL
6-48

( * #+ ,<! # +! ,
When PIR/CT is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read. CT allows the scanner to provide feedback to the cashier on how to scan in a more ergonomic fashion.
PIR/CT = ENABLE
6-49

Specifies the current scanner interface. Selections are:
INTERFACE TYPE INTERFACE IDENTIFICATION NUMBERa
RS-232 Single Cable 20
IBM Port 17 04
Null Interface Indicated by 7-segment FRU display flashing
a. To access a scanner’s interface identification number, place the
scanner in Scanner Diagnostic Mode and view the 7-segment FRU display (reference Scanner Diagnostic Mode in Section 2 for more information).
A new scanner may have been shipped from the factory with a Null Inter- face (no interface type selected) to ensure system compatibility at instal- lation. In this case, the correct Interface Type programming bar code must be scanned first before the scanner can be used with a POS system.
If the scanner’s interface type must be changed, always be sure that inter- face configuration is the FIRST item scanned during a programming ses- sion. (Selecting an interface type resets ALL other configuration items to the factory default for that interface type.)
RS-232 Standard 05 · RS-232 Wincor-Nixdorf 12 · 0 at start-up

To select the desired interface:
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
When an interface is selected, the scanner loads the factory configuration for that interface as the selection is made, erasing any and all custom configura- tion that may have previously been done.
Once the correct interface has been set, it will be necessary to proceed to the appropriate pages in this manual that select parameters and options for that interface. For example, if RS-232 is selected, turn to the pages in this manual headed as features specific to the RS-232 interface.

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
INTERFACE TYPE = RS-232 STANDARD
6-52

) $ Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
INTERFACE TYPE = RS-232 WINCOR-NIXDORF
6-53

# !2 Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Single cable installations require connection at the POS Terminal (host) port. The Scale Host port connection is not used for this interface.
6-54

7- Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
When connecting to the POS terminal, you must specify either “Scanner Only” (“Scanner/Scale Only”) or “IBM 4698” as the model number. The “Scanner Only” or “Scanner/Scale Only” setting allows for bar code label programming and sets the unit to factory defaults; the “IBM 4698” setting will allow host configuration of the unit.
The associated POS sockets are 9A and 9E.
Single cable installations require connection at the POS Terminal (host) port. The Scale Host port connection is not used for this interface.
6-55

7 7 Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Single cable installations require connection at the POS Terminal (host) port. The Scale Host port connection is not used for this interface.
6-56

Specifies the maximum number of data characters allowed in messages transmitted to the host.
To set the Maximum Host-Transmitted Message Length:
If this configuration item is set to 0 (000), there is no general length limit imposed on data being transmitted to the host.
6-57

Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFF- ERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted. When the feature, Good Read Beep Control, is enabled, the scanner will beep when the data is placed in a transmission buffer.
When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered.
To select the Number of Host Transmission Buffers:
NUMBER OF HOST TRANSMISSION BUFFERS = 2
6-58

This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the prefix that is added to beginning of label transmission.
To specify the Global Prefix Character(s):
3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the hex designation for the desired character(s). A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-char- acter value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. Up to 20 hex pairs can be designated.
To specify “no Global Prefix,” scan 00.

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
TERMINATE SEQUENCE
6-60

This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that is added to end of a label trans- mission. Three standard options are available below. Contact your dealer for other alternate settings for this feature.
To set the Global Suffix:
6-61

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GLOBAL SUFFIX = CR LF
6-62

IBM interfaces offer specific control over interaction with certain devices.

The IBM USB interface provides its own set of options. Refer to the feature, IBM USB Interface Options, in this chapter.
Options for this feature are as follows:
IBM INTERFACE OPTION = IGNORE HOST I/F CONFIG OF SCANNER & SCALE

This feature applies to IBM Port 17 ONLY.
Specifies IBM scale address for IBM Port 17. The following three addresses are available:
To set the IBM Scale Address:
6-64

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM SCALE ADDRESS = 6E
6-65

This feature enables/disables scanner’s ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B.
When enabled, this feature has no effect on IBM Port 17.
To enable/disable the IBM Transmit Labels in Code 39 Format feature:
IBM TRANSMIT LABELS IN CODE 39 FORMAT = DISABLE
IBM TRANSMIT LABELS IN CODE 39 FORMAT = ENABLE

The IBM-USB interface offers specific control over interaction with cer- tain devices. Options for this feature are as follows:
This feature applies only to the IBM USB interface. For other IBM interfaces, refer to the feature, IBM Interface Options, earlier in this chapter.
IBM USB INTERFACE OPTION = FULL HOST INTERFACE SUPPORT

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM USB INTERFACE OPTION = COMPATIBLE W/MAGELLAN SL HOST I/F SUP-
IBM USB INTERFACE OPTION = IGNORE HOST I/F CONFIG OF SCANNER &
6-68

The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scan- ners you may already have connected to a USB POS, you may need to change this setting to enable all scanners to communicate. Options are:
IBM USB SCANNER DEVICE TYPE = TABLE TOP SCANNER
6-69

This feature selects the baud rate required for sending and receiving data.

Single cable interfaces are limited to Baud Rate selections up to 19200. They cannot communicate at Baud Rates of 38400 and up.
To specify the RS-232 Baud Rate:
RS-232 BAUD RATE = 2400
6-70

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 BAUD RATE = 9600
6-71

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 BAUD RATE = 38400
6-72

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 BAUD RATE = 115200
6-73

Specifies number of data bits required for sending and receiving data.

8 data bits with 2 stop bits and parity enabled is not a valid configuration.
RS-232 NUMBER OF DATA BITS = 8
6-74

Specifies number of stop bits required for sending and receiving data.

8 data bits with 2 stop bits and parity enabled is not a valid configuration.
RS-232 NUMBER OF STOP BITS = 2
6-75

Specifies parity required for sending and receiving data.
8 data bits with 2 stop bits and parity enabled is not a valid configuration.
Options for this setting are:
6-76

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 PARITY = ODD
6-77

Enables/disables use of the RS-232 CTS signal for flow control and/or scan control.
Options are:
6-78

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 HARDWARE CONTROL = ENABLE CTS SCAN CONTROL
6-79

Specifies delay between the end of one character and the beginning of the next in 10-millisecond increments.
To set the RS-232 Intercharacter Delay:
100 = 1,000ms (1 second)
6-80
001 = 10ms · 005 = 50ms · 040 = 400ms

Enables/disables RS-232 Flow Control using XON/ XOFF characters. .

This item will be ignored when the feature, RS-232 NAK Character, is enabled
RS-232 SOFTWARE FLOW CONTROL = ENABLE
6-81

When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmis- sion to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set via RS-232 Host Echo Quiet Interval). The scanner can be set to observe this delay before sending its data in order to avoid RS-232 transmission conflicts.

When RS-232 Host Echo is enabled, the following features are ignored: RS- 232 Software Flow Control and RS-232 ACK NAK Enable as well as all other ACK/ NAK related operations, plus processing of RS-232 host commands.
To enable/disable this feature:
RS-232 HOST ECHO = ENABLE
6-82

This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.
To set the Host Echo Quiet Interval:
100 = 1,000ms (1 second)
6-83
001 = 10ms · 005 = 50ms · 040 = 400ms

When set to ignore host commands, the scanner will ignore all host com- mands except for the minimum set necessary to keep the interface active, transmit labels, and transmit scale information. For normal operation of the interface, disable this feature.
RS-232 IGNORE HOST COMMANDS = ENABLE
6-84

Specifies whether RS-232 interface provides TTL levels on the output pins TxD and RTS.
Choices are:
RS-232 LEVELS = TTL
6-85

Enables/disables inversion of TTL.
RS-232 TTL INVERT = ENABLE
6-86

Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).
To enable/disable this feature:
RS-232 BEEP ON ASCII BEL = ENABLE
6-87

Enables/disables the ability of the scanner to beep after weight data is transmitted to the host. Scale interfaces that support this item are: RS-232 ICL, RS-232 SASI, and RS-232 Single Cable.
To enable/disable the Beep After Weigh feature:
BEEP AFTER WEIGH = ENABLE
6-88

Select for the host to beep (or not) when a not-on-file condition is detected by the host. This feature is also applicable to single cable RS-232.
ENABLE
6-89

This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are:
To select the option for RS-232 ACK NAK Enable:
RS-232 ACK/NAK = LABEL TRANSMISSION
6-90

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 ACK/NAK = LABEL & HOST
6-91

This feature specifies which ASCII character will be used as an ACK char- acter.
DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Num- ber of Data Bits, is set to 7 data bits.
To specify the RS-232 ACK Character:
3. Scan the appropriate digits from the keypad in Appendix C that represent the hex designation for the desired character. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal dig- its for the desired character. For example, if ASCII “A” were the desired ACK character, you would scan the digits “4”, then “1” (the ASCII corresponding hex value).
SET RS-232 ACK Character

This feature specifies which ASCII character will be used as a NAK char- acter.
DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits.
To specify the RS-232 NAK Character:
3. Scan the appropriate digits from the keypad in Appendix C that represent the hex designation for the desired character. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal dig- its for the desired character. For example, if ASCII “A” were the desired NAK character, you would scan the digits “4”, then “1” (the ASCII corresponding hex value).
SET RS-232 NAK Character

This option specifies the action scanner performs on expiration of the RS- 232 ACK NAK Timeout Value.
RS-232 RETRY ON ACK NAK TIMEOUT = ENABLE
6-94

This item specifies the time the scanner will wait for an ACK character from the host following a label transmission.
To set the ACK NAK Timeout Value:
00 = Infinite timeout
05 = 1,000ms (1 second)
40 = 8,000ms (8 seconds)
75 = 15,000ms (15 seconds)
6-95
01 = 200ms

This feature sets the number of times for the scanner to retry a label trans- mission under a retry condition.
To set the RS-232 ACK NAK Retry Count:
A setting of 255 specifies “retry forever.”
6-96

This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors.
To select the option for RS-232 ACK NAK Error Handling:
6-97

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 ACK NAK ERROR HANDLING = ASSUME NAK
6-98

This feature specifies whether or not Label IDs are transmitted to the host and if so, whether to attach them as a prefix or suffix.
RS-232 LABEL ID CONTROL = ENABLE AS PREFIX
6-99

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
6-100

The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces. Rather than repeat them in this section as Single Cable options, please find them referenced as follows:

This sets the type of interface protocol that will be used in Single Cable RS-232.
Options are:
SINGLE CABLE RS-232 PROTOCOL = SCANNER ONLY
6-102

Specifies how RTS and CTS are used to control the data flow. RTS is con- trolled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the con- figuration values state, to determine when to send label data.
Choices are:
RTS CTS SELECTION = OPTION 1
6-103

# !2 ! E
Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RTS CTS SELECTION = OPTION 3
6-104

# !2 ! E
Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RTS CTS SELECTION = OPTION 5
6-105

Enables/disables the ability of the scanner to use BCC.
SINGLE CABLE RS-232 USE BCC = ENABLE
6-106

Enables/disables the ability of the scanner to use ACK/NAK.
SINGLE CABLE RS-232 USE ACK/NAK = ENABLE
6-107

Enables/disables the ability of the scanner to use STX.
SINGLE CABLE RS-232 USE STX = ENABLE
6-108

This feature selects the STX character.
To specify the STX Character:
3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual. ASCII parameters must be input by scanning dec- imal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a single charac- ter value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any decimal value from 001 to 127.
6-109

Enables/disables the ability of the scanner to use ETX.
SINGLE CABLE RS-232 USE ETX = ENABLE
6-110

Allows selection of the ETX character.
To specify the ETX Character:
3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual. ASCII parameters must be input by scanning dec- imal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a single charac- ter value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any decimal value from 001 to 127.
6-111

When PSC extensions are enabled, scale calibration mode information is communicated to the host. Contact Customer Support for the format of this information. Choices for this feature are:
SINGLE CABLE RS-232 PSC EXTENSIONS = SUPPORT PSC EXTENSIONS TO
6-112


If the scanner’s interface type must be changed, always be sure that inter- face configuration is the FIRST item scanned during a programming ses- sion. (Selecting an interface type resets ALL other configuration items — including symbology programming — to the factory default for that inter- face type.)
Enables/disables the ability of the scanner to decode UPC-A labels.
UPC-A = ENABLE
6-113

Enables/disables transmission of a UPC-A number system character.

This feature MUST be enabled for IBM interfaces for proper function.
This item is ignored when the advanced feature, Full Label Edit, is enabled.
UPC-A NUMBER SYSTEM CHARACTER TRANSMISSION = ENABLE
6-114

Enables/disables transmission of a UPC-A check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
UPC-A CHECK CHARACTER TRANSMISSION = ENABLE
6-115

Enables/disables expansion of UPC-A labels to EAN/JAN-13.
EXPAND UPC-A TO EAN/JAN-13 = ENABLE
6-116

This feature enables/disables transmission of the UPC/EAN AIM symbol- ogy identifier.
UPC/EAN AIM ID = ENABLE
6-117

This feature specifies a UPC-A label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-118

This feature specifies a UPC-A 2-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-119

This feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-120

This feature specifies a UPC-A 128 Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-121

Enables/disables the ability of the scanner to decode UPC-E labels.
UPC-E = ENABLE
6-122

Enables/disables transmission of a UPC-E number system character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
UPC-E NUMBER SYSTEM CHARACTER TRANSMISSION = ENABLE
6-123

Enables/disables transmission of a UPC-E check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
UPC-E CHECK CHARACTER TRANSMISSION = ENABLE
6-124

0* !0 !.
Enables/disables expansion of UPC-E labels to UPC-A.
EXPAND UPC-E TO UPC-A = ENABLE
6-125

Enables/disables expansion of UPC-E labels to EAN/JAN-13.
EXPAND UPC-E TO EAN/JAN-13 = ENABLE
6-126

This feature specifies a UPC-E label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-127

This feature specifies a UPC-E 2-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-128

This feature specifies a UPC-E 5-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-129

This feature specifies a UPC-E 128 Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-130

Enables/disables the ability of the scanner to decode EAN/JAN-13 labels.
EAN-13 = ENABLE
6-131

Enables/disables transmission of EAN/JAN-13 first character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
EAN-13 FIRST CHARACTER TRANSMISSION = ENABLE
6-132

Enables/disables transmission of an EAN/JAN-13 check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
EAN-13 CHECK CHARACTER TRANSMISSION = ENABLE
6-133

Enables/disables conversion of EAN/JAN-13 labels starting with 978 to Bookland ISBN labels.
EAN-13 ISBN Conversion= DISABLE
EAN-13 ISBN Conversion = ENABLE

This feature specifies an EAN 13 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-135

This feature specifies an EAN-13 2-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-136

This feature specifies an EAN-13 5-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-137

This feature specifies an EAN-13 128 Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-138

This feature enables/disables transmission of the Bookland AIM symbol- ogy identifier.
BOOKLAND AIM ID = ENABLE
6-139

This feature specifies a Bookland label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-140

Enables/disables the ability of the scanner to decode EAN/JAN-8 labels.
EAN-8 = ENABLE
6-141

Enables/disables transmission of an EAN/JAN-8 check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
EAN-8 CHECK CHARACTER TRANSMISSION = ENABLE
6-142

Enables/disables expansion of EAN/JAN-8 labels to EAN/JAN-13.
EXPAND EAN/JAN-8 TO EAN/JAN-13 = ENABLE
6-143

This feature specifies an EAN 8 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-144

This feature specifies an EAN-8 2-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-145

This feature specifies an EAN-8 5-Digit Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-146

This feature specifies an EAN-8 128 Supplemental label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-147

Decoding levels allow the decoder to be set to perform at one of four selectable levels:
Use caution when setting this feature, as the aggressive settings for this fea- ture allow a higher potential for misreads.
It is important to note that the default for this feature is the “Slightly More Aggressive” setting. For default settings for other features, see Appendix E.

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 DECODING LEVELS = SLIGHTLY MORE AGGRESSIVE
6-149

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 DECODING LEVELS = VERY AGGRESSIVE
6-150

The following pages contain other selectable features for UPC/EAN sym- bologies:

Enables/disables the ability of the scanner to decode a class of UPC/EAN labels with voids. The label voids may be caused by printing defects or physical damage. This feature may be helpful in environments with in- store printed labels.
Enabling this feature increases the potential of misreads.
UPC/EAN RECONSTRUCTION = ENABLE
6-152

Enables/disables calculation and verification of price/weight check digits. Applies to all UPC-A and EAN/JAN-13 labels with eligible1 Number Sys- tem/First Character digits.
Options are:

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
PRICE WEIGHT CHECK = 5-DIGIT PRICE/WEIGHT
6-154

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
PRICE WEIGHT CHECK = 5-DIGIT EUROPEAN PRICE/WEIGHT
6-155

Enables/disables the ability of the scanner to decode EAN two-label pairs.
Contact Customer Support for details about advanced programming for this feature.
EAN TWO LABEL = ENABLE
6-156

The scanner is capable of processing different types of addon codes, including:
Options are provided on the following pages for your convenience:
Contact customer support for advanced programming of optional and conditional addons.
6-157

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
6-158

Decoding levels allow the decoder to be set to perform at one of four selectable levels:
Use caution when setting this feature, as the aggressive settings for this fea- ture allow a higher potential for misreads.
It is important to note that the default for this feature is the “Slightly More Aggressive” setting. For default settings for other features, see Appendix E.

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC-A/EAN-13 DECODING LEVELS = SLIGHTLY MORE AGGRESSIVE
6-160

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC-A/EAN-13 DECODING LEVELS = VERY AGGRESSIVE
6-161

Enables/Disables the ability to convert UPCE, UPCA, EAN8, and EAN13 labels into the GTIN 14-character format.

If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN bar code.
GTIN = ENABLE
6-162

This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF (for each of the two characters).
6-163

This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 2-digit supplemental addon bar code labels are converted.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF (for each of the two characters).
6-164

This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 5-digit supplemental addon bar code labels are converted.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF (for each of the two characters).
6-165

This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and Code 128 supplemental addon bar code labels are converted
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF (for each of the two characters).
6-166

Enables/disables the ability of the scanner to decode RSS-14 labels.
This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability.
RSS-14 = ENABLE
6-167

Enables/disables transmission of the RSS-14 check character.
RSS-14 CHECK CHARACTER TRANSMISSION = ENABLE
6-168

Enables/disables the ability of RSS-14 to be transmitted as EAN-128.
RSS-14/EAN-128 EMULATION = ENABLE
6-169

When this feature is enabled, the software will not decode an RSS-14 bar code with a 2D component associated with it, and the 2D component will be discarded.
RSS-14 2D COMPONENT = ENABLE
6-170

This feature enables/disables transmission of the RSS-14 AIM symbology identifier.
RSS-14 AIM ID = ENABLE
6-171

This feature specifies an RSS-14 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-172

Enables/disables the ability of the scanner to decode RSS-Expanded labels.
This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability.
RSS-EXPANDED = ENABLE
6-173

Enables/disables EAN 128 emulation for RSS Expanded.
RSS EXPANDED/EAN-128 EMULATION = ENABLE
6-174

When this feature is enabled, the software will not decode an RSS Expanded bar code with a 2D component associated with it, and the 2D component will be discarded.
RSS EXPANDED 2D COMPONENT = ENABLE
6-175

This feature enables/disables transmission of the RSS Expanded AIM symbology identifier.
RSS EXPANDED AIM ID = ENABLE
6-176

This feature specifies an RSS Expanded label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-177

This feature specifies either variable-length or fixed-length decoding for RSS Expanded.

If variable-length control was selected, you must now set the features RSS Expanded Maximum Label Length and RSS Expanded Minimum Label Length. If fixed-length control was selected, you must now set RSS Expanded Fixed Length 1 and RSS Expanded Fixed Length 2.
RSS EXPANDED LENGTH CONTROL = FIXED-LENGTH
6-178

This feature specifies the maximum allowable length of an RSS Expanded label.
Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variable-length decoding.
Maximum Label Length should be greater than or equal to Minimum Label Length.
6-179

This feature specifies the minimum allowable length of an RSS Expanded label.
Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variable-length decoding.
Minimum Label Length should be less than or equal to Maximum Label Length.
6-180

This feature specifies RSS Expanded first fixed length.
This applies when RSS Expanded Length Control is set to fixed- length decoding.
6-181

This feature specifies RSS Expanded second fixed length.
This applies when RSS Expanded Length Control is set to fixed- length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-182

Enables/disables the ability of the scanner to decode Code 39 labels.
CODE 39 = ENABLE
6-183

Enables/disables transmission of Code 39 start and stop characters.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
CODE 39 START STOP CHARACTER TRANSMISSION = ENABLE
6-184

Enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in label is treated as a data character.

If check calculation is disabled, the risk is increased that a misread can occur.
CODE 39 CHECK CHARACTER CALCULATION = ENABLE
6-185

Enables/disables transmission of optional Code 39 check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
CODE 39 CHECK CHARACTER TRANSMISSION = ENABLE
6-186

Enables/disables the ability of the scanner to translate to Code 39 full ASCII labels.
CODE 39 FULL ASCII = ENABLE
6-187

This feature enables/disables transmission of the Code 39 AIM symbology identifier.
CODE 39 AIM ID = ENABLE
6-188

This feature specifies a Code 39 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-189

This feature specifies whether variable-length or fixed-length decoding will be set for Code 39.

If variable-length control was selected, you must now set the features Code 39 Maximum Label Length and Code 39 Minimum Label Length. If fixed-length control was selected, you must now set Code 39 Fixed Length 1 and Code 39 Fixed Length 2.
CODE 39 LENGTH CONTROL = FIXED-LENGTH
6-190

This feature specifies the maximum allowable length of a Code 39 label.
Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-191

This feature specifies the minimum allowable length of a Code 39 label.
Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding.
Minumum label length should be less than or equal to maximum label length.
6-192

This feature specifies Code 39 first fixed length.
This applies when Code 39 Length Control is set to fixed-length decoding.
The minimum decodable length is four when an optional check character is present.
6-193

This feature specifies Code 39 second fixed length.
This applies when Code 39 Length Control is set to fixed-length decoding.
If Fixed Length 2 is set to 00, then Fixed Length 1 will apply
6-194

Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
CODE 39 STITCHING = ENABLE
6-195

Enables/disables the ability of the scanner to decode Italian Pharmacode 39 labels.
PHARMACODE 39 = ENABLE
6-196

Enables/ disables transmission of start and stop characters for Pharmacode 39.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
PHARMACODE 39 START STOP CHARACTER TRANSMISSION = ENABLE
6-197

Enables/disables transmission of Pharmacode 39 check character.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
PHARMACODE 39 CHECK CHARACTER TRANSMISSION = ENABLE
6-198

This feature specifies a Pharmacode 39 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-199

Enables/disables the ability of the scanner to decode Code 128 labels.
CODE 128 = ENABLE
6-200

Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4.

CODE 128 TRANSMIT FUNCTION CHARACTERS = ENABLE
6-201

Enables/disables conversion of Code 128 labels to Code 39.
CONVERT CODE 128 TO CODE 39 = ENABLE
6-202

This feature enables/disables transmission of the Code 128 AIM symbol- ogy identifier.
CODE 128 AIM ID = ENABLE
6-203

This feature specifies a Code 128 label ID to be added to bar code data..
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-204

This feature specifies whether variable-length or fixed-length decoding will be set for Code 128.

If variable-length control was selected, you must now set the features Code 128 Maximum Label Length and Code 128 Minimum Label Length. If fixed-length control was selected, you must now set Code 128 Fixed Length 1 and Code 128 Fixed Length 2.
CODE 128 LENGTH CONTROL = FIXED-LENGTH
6-205

This feature specifies the maximum allowable length of a Code 128 label.
Length in this case includes function characteres and data characters, but does not include function code change or check character. This fea- ture applies when Code 128 Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-206

This feature specifies the minimum allowable length of a Code 128 label.
Length in this case includes function characteres and data characters, but does not include function code change or check character. This fea- ture applies when Code 128 Length Control is set to variable-length decoding.
Minumum label length should be less than or equal to maximum label length.
6-207

This feature specifies Code 128 first fixed length.
This applies when Code 128 Length Control is set to fixed-length decoding.
6-208

This feature specifies Code 128 second fixed length.
This applies when Code 128 Length Control is set to fixed-length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-209

Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
CODE 128 STITCHING = ENABLE
6-210

Enables/disables the ability of the scanner to decode EAN-128 labels.
EAN-128 = ENABLE
6-211

This feature enables/disables transmission of the EAN 128 AIM symbol- ogy identifier.
EAN 128 AIM ID = ENABLE
6-212

This feature specifies an EAN 128 label ID to be added to bar code data..
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-213

Enables/disables the ability of the scanner to decode Interleaved 2 of 5 labels.
I 2 OF 5 = ENABLE
6-214

Enables/disables calculation and verification of an optional Interleaved 2 of 5 check character.

If check character calculation is disabled, the risk is increased that a mis- read can occur. When disabled, any check characters in a bar code are treated as data characters.
I 2 of 5 CHECK CHARACTER CALCULATION = DISABLE
I 2 of 5 CHECK CHARACTER CALCULATION = ENABLE

Enables/disables transmission of an optional Interleaved 2 of 5 check char- acter.

This feature applies only when I 2 of 5 Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled.
I 2 of 5 CHECK CHARACTER TRANSMISSION = DISABLE
I 2 of 5 CHECK CHARACTER TRANSMISSION = ENABLE

This feature enables/disables transmission of the I 2 of 5 AIM symbology identifier.
I 2 of 5 AIM ID = DISABLE
I 2 of 5 AIM ID = ENABLE

This feature specifies an I 2 of 5 label ID to be added to bar code data..
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
SET I 2 of 5 LABEL ID

This feature specifies whether variable-length or fixed-length decoding will be set for I 2 of 5.

If variable-length control was selected, you must now set the features I 2 of 5 Maximum Label Length and I 2 of 5 Minimum Label Length. If fixed-length control was selected, you must now set I 2 of 5 Fixed Length 1 and I 2 of 5 Fixed Length 2.
I 2 OF 5 LENGTH CONTROL = FIXED-LENGTH
6-219

This feature specifies the maximum allowable length of an I 2 of 5 label.
Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-220

This feature specifies the minimum allowable length of an I 2 of 5 label.
Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
6-221

This feature specifies I 2 of 5 first fixed length.
This applies when I 2 of 5 Length Control is set to fixed-length decoding.
6-222

This feature specifies I 2 of 5 second fixed length.
This applies when I 2 of 5 Length Control is set to fixed-length decod- ing.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-223

Enables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
I 2 OF 5 STITCHING = ENABLE
6-224

Enables/disables the ability of the scanner to decode Codabar labels.
CODABAR = ENABLE
6-225

Enables/disables transmission of Codabar start and stop characters.

This item is ignored when the advanced feature, Full Label Edit, is enabled.
CODABAR START STOP CHARACTER TRANSMISSION = ENABLE
6-226

This feature selects the format of transmitted Codabar start/stop charac- ters.
Options are:
CODABAR START STOP CHARACTER = ABCD/ABCD
6-227

Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
CODABAR START STOP CHARACTER = abcd/tn* e
CODABAR START STOP CHARACTER = abcd/abcd

Enables/disables the requirement that start and stop characters match.
CODABAR START STOP CHARACTER MATCH = ENABLE
6-229

Enables/disables calculation and verification of an optional Codabar check character.

If check character calculation is disabled, the risk is increased that a mis- read can occur. When disabled, any check characters in a bar code are treated as data characters.
CODABAR CHECK CHARACTER CALCULATION = ENABLE
6-230

Enables/disables transmission of an optional Codabar check character.

Applies only when Codabar Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled.
CODABAR CHECK CHARACTER TRANSMISSION = ENABLE
6-231

This feature enables/disables transmission of the Codabar AIM symbology identifier.
CODABAR AIM ID = ENABLE
6-232

This feature specifies a Codabar label ID to e added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-233

This feature specifies whether variable-length or fixed-length decoding will be set for Codabar.

If variable-length control was selected, you must now set the features Codabar Maximum Label Length and Codabar Minimum Label Length. If fixed-length control was selected, you must now set Codabar Fixed Length 1 and Codabar Fixed Length 2.
CODABAR LENGTH CONTROL = FIXED-LENGTH
6-234

This feature specifies the maximum allowable length of a Codabar label.
Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-235

This feature specifies the minimum allowable length of a Codabar label.
Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
6-236

This feature specifies Codabar first fixed length.
Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters.
This feature applies when Codabar Length Control is set to fixed- length decoding.
Decodable length is four when the optional check character is present.
6-237

This feature specifies Codabar second fixed length.
Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters.
This feature applies when Codabar Length Control is set to fixed- length decoding.
Decodable length is four when the optional check character is present.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-238

Enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
CODABAR STITCHING = ENABLE
6-239

Enables/disables the ability of the scanner to decode Code 93 labels.
CODE 93 = ENABLE
6-240

This feature enables/disables transmission of the Code 93 AIM symbology identifier.
CODE 93 AIM ID = ENABLE
6-241

This feature specifies a Code 93 label ID to be added to bar code data..
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-242

This feature specifies whether variable-length or fixed-length decoding will be set for Code 93.

If variable-length control was selected, you must now set the features Code 93 Maximum Label Length and Code 93 Minimum Label Length. If fixed-length control was selected, you must now set Code 93 Fixed Length 1 and Code 93 Fixed Length 2.
CODE 93 LENGTH CONTROL = FIXED-LENGTH
6-243

This feature specifies the maximum allowable length of a Code 93 label.
Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-244

This feature specifies the minimum allowable length of a Code 93 label.
Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
6-245

This feature specifies Code 93 first fixed length.
This applies when Code 93 Length Control is set to fixed-length decoding.
6-246

This feature specifies Code 93 second fixed length.
This applies when Code 93 Length Control is set to fixed-length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-247

Enables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
CODE 93 STITCHING = ENABLE
6-248

Enables/disables the ability of the scanner to decode MSI/Plessey labels.
MSI/PLESSEY = ENABLE
6-249

Enables/disables calculation and verification of optional MSI/Plessey check characters.

If check character calculation is disabled, the risk is increased that a mis- read can occur. When disabled, any check characters in a bar code are treated as data characters.
MSI/PLESSEY CHECK CHARACTER CALCULATION = ENABLE
6-250

Specifies number of MSI/Plessey check characters to be calculated and verified.

MSI/PLESSEY NUMBER OF CHECK CHARACTERS = 2
6-251

Enables/disables transmission of optional MSI/Plessey check characters.

This feature applies only when MSI/Plessey Check Character Calcu- lation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled.
MSI/PLESSEY CHECK CHARACTER TRANSMISSION = ENABLE
6-252

This feature enables/disables transmission of the MSI/Plessey AIM sym- bology identifier.
MSI/PLESSEY AIM ID = ENABLE
6-253

This feature specifies an MSI/Plessey label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is dis- abled.
3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corre- sponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
6-254

This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey.

If variable-length control was selected, you must now set the features MSI/Plessey Maximum Label Length and MSI/Plessey Mini- mum Label Length. If fixed-length control was selected, you must now set I 2 of 5 Fixed Length 1 and MSI/Plessey Fixed Length 2.
MSI/PLESSEY LENGTH CONTROL = FIXED-LENGTH
6-255

This feature specifies the maximum allowable length of an MSI/Plessey label.
Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This feature applies when MSI/Plessey Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-256

This feature specifies the minimum allowable length of an MSI/Plessey label.
Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/ Plessey Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
6-257

This feature specifies MSI/Plessey first fixed length.
This applies when MSI/Plessey Length Control is set to fixed-length decoding.
6-258

This feature specifies MSI/Plessey second fixed length.
This applies when MSI/Plessey Length Control is set to fixed-length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-259

Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/ Plessey bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
MSI/PLESSEY STITCHING = ENABLE
6-260

Enables/disables the ability of the scanner to decode Standard 2 of 5 labels.
STANDARD 2 OF 5 = ENABLE
6-261

Enables/disables calculation and verification of an optional Standard 2 of 5 check character.
If check character calculation is disabled, the risk is increased that a mis- read can occur. When disabled, any check character in a bar code is treated as data character.
STANDARD 2 of 5 CHECK CHARACTER CALCULATION = DISABLE
STANDARD 2 of 5 CHECK CHARACTER CALCULATION = ENABLE

Enables/disables transmission of an optional Standard 2 of 5 check charac- ter.
This feature applies only when Standard 2 of 5 Check Character Cal- culation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled.
STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION = DISABLE
STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION = ENABLE

This feature enables/disables transmission of the Standard 2 of 5 AIM symbology identifier.
STANDARD 2 of 5 AIM ID = DISABLE
STANDARD 2 of 5 AIM ID = ENABLE

This feature specifies an Standard 2 of 5 label ID to be added to bar code data.
The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
3. Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF.
SET STANDARD 2 of 5 LABEL ID

This feature specifies whether variable-length or fixed-length decoding will be set for Standard 2 of 5.
If variable-length control was selected, you must now set the features Standard 2 of 5 Maximum Label Length and Standard 2 of 5 Mini- mum Label Length. If fixed-length control was selected, you must now set Standard 2 of 5 Fixed Length 1 and Standard 2 of 5 Fixed Length 2.
STANDARD 2 OF 5 LENGTH CONTROL = FIXED-LENGTH
6-266

This feature specifies the maximum allowable length of a Standard 2 of 5 label.
Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding.
Maximum label length should be greater than or equal to minimum label length.
6-267

This feature specifies the minimum allowable length of an Standard 2 of 5 label.
Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
6-268

This feature specifies Standard 2 of 5 first fixed length.
This applies when Standard 2 of 5 Length Control is set to fixed- length decoding.
6-269

This feature specifies Standard 2 of 5 second fixed length.
This applies when Standard 2 of 5 Length Control is set to fixed-length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
6-270

Enables/disables stitching for Standard 2 of 5 labels. When parts of a Stan- dard 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
This applies when Standard 2 of 5 Length Control is set to fixed-length decoding.
STANDARD 2 OF 5 STITCHING = ENABLE
6-271


.** .
Figure A-1 shows the operator’s controls and indicators. The descriptions following identify the use or function of each component.
=# .@ !
Yellow LED Scale Zero Push Button
The control panel consists of two indicator LEDs and two push buttons as described in the following pages.
Volume/Tone Push Button · Green LED

The green LED indicates scanner status, and the yellow LED is primarily used to show scale status as described in Table A-1 below:
LED INDICATION DURATION COMMENT
Scale at Zeroa Yellow LED on steady The scale is at rest and reads zero weight.
Green LED on steady and dim The scanner is ready for operation. Scanning is immediately available.
Good Read Indicationa
Green LED - bright flash Indicates a bar code has been read and decoded.
Green LED - Continuous flashing Indicates the scanner is in Label Programming Mode. Cycle power to exit Programming Mode.
Green LED blinks at a 2-second rate The scanner motor and/or laser have automati- cally switched off and the unit has entered Sleep Mode due to extended inactivity.
Host Disabled 1-second off, 1/10-second on Host has disabled scanning.
Serves notice that a fatal FRU failure has been detected. Consult Error Codes in Section 4 for more details. If a low tone is heard, but continuous flashing is not observed, the scanner can still func- tion in a limited capacity. Call systems support for service in either case.
Audible low tone 3 seconds. Alternating Green/Yellow LED flashes continuously.
Field Replace- able Unit (FRU) Warning (Error Mode)
Green LED flashes a coded sequence in concert with the speaker. Occurs ONLY upon Volume/Tone button push fol- lowing a FRU warning. Enables service techni- cians to identify FRU failures.
a. Certain functions of the Green and Yellow LEDs are selectable to be enabled or disabled. Your scanner
may not be programmed to display all indications.

The Volume/Tone Push Button also performs multiple functions depend- ing upon the duration of time it is pressed:
Volume changes made using the Volume/Tone Push Button are lost when the scanner is powered-down and are reset to the factory default setting. If you wish to permanently change the volume, use the special programming labels in Section 6, Programming.

2 .@:% < 7 =
Alternatively, the scanner can be awakened by: - Moving an object through the scan zone. - A weight change on the scale. - Scanning with an attached auxiliary scanner.
Momentary (when scanner is asleep)
Wakes scanner from Sleep Mode
Press the push button momentarily to increase speaker volume. When the loudest volume is reached, a repeated press of the push button cycles volume back to the lowest setting, then volume increases on subse- quent press(es). Five volume levels are available.
Momentary (when scanner is awake) Increments volume
Press the push button for approximately 2 seconds, then release. Each time this is done, the beeper will sound at one of three tones. Stop when the desired tone (high, medium or low) is sounded.
Hold, then release when the beeper sounds
This mode allows system support personnel to trouble- shoot problems with the scanner. Upon entering Scan- ner Diagnostic Mode, view the 7-segment display to view Interface Type, Bootloader Version Number, Appli- cation Version Number and Configuration File Number. This mode is used to determine if a scanner can read bar codes. Press the button for eight seconds or cycle power to exit Scanner Diagnostics Mode and reset the scanner.
4 Seconds Scanner Diagnostics Modea
8 Seconds Resets Scannerb Only system support personnel should perform a reset.
a. By standard default, this function is normally disabled to prevent accidental activation by users. b. Users should not perform scanner resets except under the direction of trained systems support person-
nel.
Increments tone

The Scale Zero Push Button is used for multiple functions as listed in Table A-3.
The Scale Zero Push Button has no function in a “scanner only” model.
2 .@ / 7 =
When programmed to do so, the yellow LED should be lit when no weight is on the scale, indicating scale at zero. If it is not, press the switch to zero the scale. The unit will sound a “click” upon pressing the button.
This mode allows system support personnel to troubleshoot prob- lems with the scale. Momentarily press the Scale Zero Push Button or cycle power to exit Scale Diagnostics Mode.
4 Seconds Scale Diagnostics Modea
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to ini-
tiate this function under normal circumstances.
This switch initiates the scale’s calibration routine. A certified weight set is needed to perform the scale calibration steps detailed in Section 5, Cali- bration. This switch is not included in scanners without scale modules.
!2 This seal allows you to secure the Calibration Switch access cover and restrict access to the Calibration Switch. If the calibration seal is broken or missing, you may be prohibited from operating the scale without recertifi- cation. Check local and state requirements for specific restrictions.
Momentary Zero Scale

!2 ! This cover restricts access to the Calibration Switch to help guard against unauthorized tampering when sealed.
There are regulations that must be followed in order to ensure compli- ance when operating a weighing device such as the scanner/scale. Fail- ure to observe and comply with these regulations could result in legal action.
LEGAL NOTE
A-6

!2 %
The following pages contain pinout information, enabling you to create standard interface cables for use in interconnecting the scanner, scale, external handheld scanner, and POS terminal.
) 1 %

! RJ45, 10 Position
2 7@ !2
1 +5V pullup +5V pullup
2 CTS in Clear To Send (input)
3 N/C No Connection
4 RTS out Request To Send (output)
5 RxD in Receive Data (Input)
6 TxD out Transmit Data (output)
7 N/C No Connection
8 +5V out +5V out
9 GND Signal Ground
10 N/C No Connection
!2

! RJ45, 10 Position
1 +5V pullup +5V pullup
2 CTS IN Clear To Send (input)
3 N/C No Connection
4 RTS OUT Request To Send (output)
5 RxD IN Receive Data (Input)
6 TxD OUT Transmit Data (output)
7 N/C No Connection
8 +5V out +5V out
9 Gnd Signal Ground
10 N/C No Connection
!2 · 2 7@

! RJ45, 10 Position
1 +5V pullup +5V pullup
2 N/C No Connection
3 N/C No Connection
4 Serial I/O B Serial Data -
5 N/C No Connection
6 Serial I/O A Serial Data +
7 N/C No Connection
8 +5V out +5V out
9 Ground Signal Ground
10 N/C No Connection
!2 · 2 7

! RJ45, 10 Position
1 +5V pullup +5V pullup
2 N/C No Connection
3 N/C No Connection
5 N/C No Connection
7 N/C No Connection
8 +5V out +5V out
9 GND Signal Ground
10 N/C No Connection
!2 · 2 7"

! RJ45, 10 Position
1 +5V pullup +5V pullup
2 CTS in Clear To Send (input)
3 N/C No Connection - Reserved
4 RTS out Request To Send (output)
5 RxD in Receive Data (Input)
6 TxD out Transmit Data (output)
7 N/C No Connection
8 +5V out (500mA max) +5V out
9 GND Signal Ground
10 N/C No Connection
!2 · 2 7&

Antenna Connections. Connect ONLY using approved cables approved by the manufacturer for this product.
PIN # SIGNAL
1 GND
4 Speaker Outa
a. The “Speaker Out” line is an analog signal (5Vpp
max), connected to one of the internal speaker termi- nals, intended to connect to an external amplifier to drive an external speaker.


A (*
Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
B
C-6

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
C-7

Use the bar codes in this section to enter numbers and characters as you would select digits/characters from a keypad.
Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
F
C-8

!%%
The scanner responds to the following RS-232 commands:
Enable Scanner E 0x45
Disable Scanner D 0x44
Reset Scanner R 0x52
Not On File Indication F 0x46 Long series of beeps
Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled
Force Good Read Tone 0x01 Beeps regardless of beep setting
Bel 0x07 Force Good Read Tone
Identification request i 0x69 Returns long responsea
Health request h 0x68 Returns long responsea
Status request s 0x73 Returns long responsea
a. Call Tech Support for information.
If one of the above commands is received, the scanner will perform the steps indicated for the command. Host commands for other interfaces is also available. Contact Tech Support for more details.


=(9
The following table provides a listing of the most common factory settings for the interfaces shown.
2 0@=(9 #
Cable IBM 17 IBM USB
Double Read Timeout 60 (600ms)
Laser Timeout 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.)
Motor Timeout 40 (10 min.)
40 (10 min.)
40 (10 min.)
40 (10 min.)
40 (10 min.)
40 (10 min.)
Green LED Idle State 2 (on dim) 2 (on dim) 2 (on dim) 2 (on dim) 2 (on dim) 2 (on dim)
Power-up Beep Control 1 beep 1 beep 1 beep 1 beep 1 beep 1 beep
Good Read Beep Con- trol 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable)
Good Read Beep Fre- quency
Good Read Beep Length 8 (80ms) 8 (80ms) 8 (80ms) 8 (80ms) 8 (80ms) 8 (80ms)
Good Read Beep Vol- ume
Good Read When to Indicate
Scale Enable 0 (disable) 1 (enable) 0 (disable) 1 (enable) 1 (enable) 1 (enable)
Scale Country Mode 0 (US) 0 (US) 0 (US) 0 (US) 0 (US) 0 (US)

Cable IBM 17 IBM USB
Scale Enforced Zero Return 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
7 (RS-232 single cable)
Scale Interface Type 4 (RS-232 SASI)
4 (RS-232 SASI)
1 (IBM Port 17)
Scale Motion Level Fil- ter 0 (low) 0 (low) 0 (low) 0 (low) 0 (low) 0 (low)
Scale LED Enable 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable)
Remote Display — Enable/Disable 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable)
EAS Active State 0 (active low)
EAS Timeout 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms) 2 (20ms)
Aux Port Mode 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
Laser Failure Mode 0 (single OK)
Productivity Index Reporting (PIR)/Cashier Training (CT)
0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
Maximum Host-Trans- mitted Message Length 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit)
Number of Host Trans- mission Buffers
Global Prefix ("")
Global Suffix 0D00 ("\0D")
IBM Scale Address 110
IBM Transmit Labels in Code 39 Format 0 (disable)

Cable IBM 17 IBM USB
IBM USB Scanner Device Type
RS-232 Baud Rate 1 (9600) 1 (9600) 1 (9600) 1 (9600)
RS-232 Number of Data Bits
1 (8 data bits)
1 (8 data bits)
1 (8 data bits)
0 (7 data bits)
RS-232 Number of Stop Bits
0 (1 stop bit)
0 (1 stop bit)
0 (1 stop bit)
0 (1 stop bit)
RS-232 Parity 0 (none) 0 (none) 2 (odd) 2 (odd)
RS-232 Hardware Con- trol 0 (disable) 0 (disable) 1 (enable CTS flow)
RS-232 Intercharacter Delay 0 (none) 0 (none) 0 (none)
RS-232 Software Flow Control 0 (disable) 0 (disable) 0 (disable) 0 (disable)
RS-232 Host Echo 0 (disable) 0 (disable)
RS-232 Host Echo Quiet Interval 1 (10ms) 1 (10ms)
RS-232 Ignore Host Commands 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
RS-232 TTL 0 (normal RS-232)
RS-232 TTL Invert 0 (disable) 0 (disable)
RS-232 Beep on ASCII BEL 0 (disable) 0 (disable) 0 (disable)
RS-232 Beep After Weigh 1 (enable) 1 (enable) 0 (disable) 1 (enable)
RS-232 Beep on Not on File 1 (enable) 1 (enable) 1 (enable) 1 (enable)

Cable IBM 17 IBM USB
RS-232 ACK NAK Enable 0 (disable) 0 (disable) 0 (disable)
RS-232 ACK Character 6 (ACK) 6 (ACK) 6 (ACK)
RS-232 NAK Character 21 (NAK) 21 (NAK) 21 (NAK)
RS-232 Retry on ACK NAK Timeout 1 (enable) 1 (enable) 1 (enable)
RS-232 ACK NAK Tim- eout Value 1 (200ms) 1 (200ms) 1 (200ms)
RS-232 ACK NAK Retry Count 3 resets 3 resets 3 resets
RS-232 ACK NAK Error Handling
RS-232 Label ID Con- trol
1 (enable as prefix)
1 (enable as prefix)
1 (enable as prefix)
1 (enable as prefix)
Single Cable RS-232 Scanner Only Protocol
Single Cable RS-232 RTS CTS Selection Option 5
Single Cable RS-232 Use BCC 0 (disable)
Single Cable RS-232 Use ACK/NAK 0 (disable)
Single Cable RS-232 Use STX 1 (enable)
Set Single Cable RS- 232 STX Character 83 (S)
Single Cable RS-232 Use ETX 1 (enable)
Set Single Cable RS- 232 ETX Character 13 (CR)

Cable IBM 17 IBM USB
Standard 2 of 5 Label ID 5300 ("S") 5300 ("S") 5300 ("S") 5300 ("S") 5300 ("S") 5300 ("S")
Standard 2 of 5 Length Control
Standard 2 of 5 Maxi- mum Label Length 50
Standard 2 of 5 Mini- mum Label Length 6
Standard 2 of 5 Fixed Length 1 10
Standard 2 of 5 Fixed Length 2 0
Standard 2 of 5 Stitch- ing 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)


9=% 1 %
This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxiliary port as transmitted from a handheld scanner.

The following sections describe label transmission formats that are typi- cally observed in factory configurations of PSC handheld scanners.
!.



0.$3 • Check digit must be included in label data and is assumed to be correct
0.$3 9#** % • Check digit must be included in label data and is assumed to be correct.
0.$3 &9#** % • Check digit must be included in label data and is assumed to be correct.
0.$3 ! 3** % • Check digit must be included in label data and is assumed to be correct.

0.$ • Check digit must be included in label data and is assumed to be correct
0.$ 9#** % • Check digit must be included in label data and is assumed to be correct
0.$ &9#** % • Check digit must be included in label data and is assumed to be correct.
0.$ ! 3** % • Check digit must be included in label data and is assumed to be correct




AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13. The ’]’ character must be the first character received in the label transmission from the handheld.
The following sections describe the prefix strings and identify what spe- cific label characteristics can be supported.
!.
0.$ • Check digit must be included in label data and is assumed to be correct.
0.$3 • Check digit must be included in label data and is assumed to be correct.

UPC-A 2-Digit addon ’]E00060992011187]E112’
UPC-E 2-Digit addon ’]E00000000998875]E112’
EAN-8 2-Digit addon ’]E400210126]E112’
EAN-13 2-Digit addon ’]E01101234567891]E112’
UPC-A 5-Digit addon ’]E00060992011187]E212345’
UPC-E 5-Digit addon ’]E00000000998875]E212345’
EAN-8 5-Digit addon ’]E400210126]E212345’
EAN-13 5-Digit addon ’]E01101234567891]E212345’

UPC-A Code 128 addon ’]E00060992011187]C08100000951’
UPC-E Code 128 addon ’E00000000998875]C08100000951’
EAN-8 Code 128 addon ’]E400210126]C08100000951’
EAN-13 Code 128 addon ’]E01101234567891]C08100000951’
78 • The 'Bookland' / ISBN code will be formatted as a vendor spe- cific AIM label.







The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters.
Char. Hex No. ASCII
Char. Hex No. ASCII
Char. Hex No. ASCII
Char.
No.
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
! “ # $ %
STX ETX EOT ENQ ACK
BEL
’ ( ) * +
I J K L M N O P Q R S T U V W
, - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
n o p q
SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN
t u v w
x y z { | } ~ DEL
[ \ ] ^ _

Asia Pacific PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291
Italy PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/6859496
Australia PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688
Japan PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656
France PSC S.A.R.L. LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.44
Latin America PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Fax: (305) 539-0206
Germany PSC GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58
United Kingdom PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Fax: 44 (0) 1923 809 505
Corp. Headquarters PSC Inc. Portland, OR Telephone: (503) 553-3920 Fax: (503) 553-3940
PSC Inc. 959 Terry Street Eugene, OR Telephone: (541) 683-5700 Fax: (541) 345-7140
©2002 PSC INC. R44-2384 (Rev. B) 3/03
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
La signification des codes d'erreur affichés à l'écran et la façon de les effacer.
| Code | Signification | Solution | |
|---|---|---|---|
| 0 Blinking | Configuration | No POS interface has been selected (Null interface). See the topic, Interface Type, in Section 6 to select the required interface using programming bar codes. | p.80 |
| 1 | Configuration Error | See Section 6, Programming, for details about configuring the scan- ner using programming bar codes. | p.80 |
| 2 | Interface Board | Unplug unit and call technical support personnel. | p.80 |
| 4 | Horizontal Lasera | Call technical support personnel. | p.80 |
| 5 | Vertical Lasera | Call technical support personnel. | p.80 |
| 6 | Digital Board | Unplug unit and call technical support personnel. | p.80 |
| 8 | Remote Display | Connect the Remote Display. If necessary, replace display or cable. Alternatively, you can disable the Remote Display using the program- ming procedures described in Section 6. | p.80 |
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Too much motion at power- up. | Check for stable installation. Change scale motion filter using the labels found in Section 6; restart. If problem persists, scale may require calibration. | p.82 | |
| Calibration lost. | Call technical support personnel. Re- calibrate; restart; recertify (if required). | p.82 | |
| Scale communication lost. Internal scanner/scale prob- lem. | Call technical support personnel; report error. | p.82 | |
| Scale module failure. | Call technical support personnel; report error. | p.82 | |
| Internal software fault. | Call technical support personnel; report error. | p.82 | |
| Internal software fault. | p.82 | ||
| Cannot zero at power- up or weight remains on scale for more than 4 minutes or weight has not returned to zero between POS weight requestsa. | - Check debris chutes. - Verify that the weigh platter moves freely. - Remove item(s) from scale - Press Scale Zero Push Button - for more information. - If the scale still fails to zero, recali- brate the scale. | p.82 |
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.