Manuel d'utilisation / d'entretien du produit 308/616 du fabricant Lucent Technologies
Aller à la page of 20
Lucent Technologies Bell Labs Innovations SPIRI T ® Communications System Model 308/616 Customer Installation Instructions 999-500-226 105772578 Issue 4 June 1989.
Intellectual property related to this product and registered to AT&T Corporation has been transferred to Lucent Technologies Incorporated. Any references within this text to American Telephone and Telegraph Corporation or AT&T should be interpreted as references to Lucent Technologies Incorporated.
INTERFERENCE INFORMATION FCC REGULATIONS PERTAINING TO THIS EQUIPMENT NOTICE Federal Communications Commission (FCC) rules require that you be notified of the following: FCC (Part 15) This equipment g.
TABLE OF CONTENTS Introduction 2 Overview of System 2 Step 1 Plan Your System 3 Step 2 Check Outlet Grounding 3 Step 3 Mount Controller 4 Mount Controller on Wall 4 Test the Incoming Telephone Lines 5.
Introduction This instruction manual will show you how to install your SPIRIT Communications System. Please read the instructions carefully before beginning installation.
Step 1 Plan Your System Draw a floor plan of your business, showing the location of the network interface jacks, where your local telephone lines come into the building. You will want to install your controller close to these jacks. Show on the floor plan the location of each telephone in your system.
Step 3 Mount Controller ■ Mount Controller on Wall Choose a location within five feet of the network interface jacks, where the local telephone company lines enter the building, and near an AC outlet that is not controlled by a switch.
■ Test the Incoming Telephone Lines. TEST: If you have a standard telephone with a modular cord, plug it into each jack of the network interface, or incoming telephone lines. If these jacks do not work you will require service by your local telephone company.
Step 4 Wiring Runs You may choose to wire your SPIRIT Communications System using 4-pair “business” wiring materials or 2-pair “customer convenience” wiring materials. While the materials are somewhat different, the procedure for labeling the wiring run is the same.
Step 4A Business (4-pair) Wiring You may choose to wire your business with 4-pair “business” wiring to be ready for future communications systems. You will need the following materials: ❑ screwd.
■ Mount Jack Panel Boxes Mount the jack panel boxes near the controller, creating a “jack field.” You will need one jack panel box for every six telephones in your system. Ideally, the jack field will be two to six inches below the controller if the controller is wall-mounted.
■ Run Cable To All Telephone Locations Select a cable extension kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, run a 200-foot cable, terminate it in a modular connecting block, plug in another cable, and repeat, up to a maximum of 1000 feet.
■ Install Modular Connecting Blocks Install a modular connecting block at each telephone location Find the modular connecting block from the Cable Extension Kit and the cable installation tool from the Wiring Installation Kit. Choose the location for the connecting block according to the figure.
Typical cable installation for one telephone location. Cable clip Identical labels Cable TELEPHONE LOCATION Modular connecting block Finish your installation by routing cables to all other telephone locations and installing modular connecting blocks for each one.
Step 4B Wiring Run, Using Customer Convenience Wiring Customer convenience wiring materials are available at your local phone store. Different situations require different materials.
Typical Installation Using Customer Convenience Wiring Sample System Directory Label Controller 10 11 12 13 700A4 PLUG Telephone Labels 630B Wall Connecting Block Wire Run Greater Than 50’ Telephone Set Modular Cord (D4BU) 25’ Max.
Step 5 Install Telephone Sets SPIRIT telephone sets are available in 6-Button and 24-Button models. The models are installed the same way. SPIRIT telephones are not like regular telephones and will not work if plugged directly into the Network Interface Jacks.
Step 6 Connect System To Wiring Runs Connect the controller to the wiring runs. Following the numbers on your wiring run labels, plug one end of a jumper cord into the jack panel box or wire junction (see pages 7 and 14) and the other end of the jumper cord into the appropriate station jack on the controller.
3. The left INTERCOM light should be lit if there is a 616 expansion unit installed correctly. If there is not an expansion unit installed, and the light does light, then there is a defect in the 308 controller.
Troubleshooting What To Do If You Have Trouble With Your System: For SPIRIT Communications Systems purchased from AT&T, a customer “hotline” (1-800-628-2888) is available to help you if you have questions about or trouble with your system.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lucent Technologies 308/616 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lucent Technologies 308/616 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lucent Technologies 308/616, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lucent Technologies 308/616 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lucent Technologies 308/616, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lucent Technologies 308/616.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lucent Technologies 308/616. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lucent Technologies 308/616 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.