Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
or visit our website at www.kitchenaid.com
In Canada, call for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.KitchenAid.ca
POUR USAGE EXTÉRIEUR Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777 ou visitez notre site web à...
Table of Contents/Table des matières 4


Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
State of California Proposition 65 Warnings:
In the State of Massachusetts, the following installation instructions apply:
the State of Massachusetts.

IMPORTANT: This side burner is manufactured for outdoor use only. For side burners that are to be used at elevations above 2000 ft (609.6 m) orifice conversion is required. See “Gas Supply Requirements” section. It is the responsibility of the installer to comply with the minimum installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the right-hand side panel. Copies of the standards listed may be obtained from: National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269
CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575
- constructed and marked in accordance with the
Specification for LP Gas Cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres, and Tubes for Transportation of Dangerous Goods; and Commission.
appliances in or on a recreational vehicle, portable trailer, boat or in any other moving installation.
- provided with a listed overfilling prevention device.
- provided with a cylinder connection device compatible
construction, see “Location Requirements” section.
with the connection for outdoor cooking gas appliances.
under overhead unprotected combustible construction.
and disconnect the LP gas supply cylinder. See “Installation Instructions” section.
outdoors and shall not be used in a building, garage, or any other enclosed area.
gas must be turned off at the supply cylinder.
from any heated surfaces.
permissible only if the cylinder is disconnected and removed from the outdoor cooking gas appliance.
from combustible materials, gasoline and other flammable vapors and liquids.
children and must not be stored in a building, garage, or any other enclosed area.
Keep the ventilation openings of the cylinder enclosure free and clear from debris.
the outdoor cooking gas appliance must be used. A replacement pressure regulator and hose assembly specific to your model is available from your outdoor cooking gas appliance dealer.
outdoor cooking gas appliance. If the hose shows excessive abrasion or wear, or is cut, it MUST be replaced before using the outdoor cooking gas appliance. Contact your dealer and use only replacement hoses specified for use with the outdoor cooking gas appliance.
valve.
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
Slight yellow tipping is normal for LP gas.
nest. A clogged tube can lead to fire under the outdoor cooking gas appliance.
If the following information is not followed exactly, a fire causing death or serious injury may occur.
outdoor cooking gas appliance.



Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Natural Gas Models
Tools Needed
Tools Needed
Parts Needed
Parts Supplied

Location Requirements Select a location that provides minimum exposure to wind and traffic paths. The location should be away from strong draft areas. Do not obstruct flow of combustion and ventilation air. Clearance to combustible construction for built-in outdoor side burners:

A grounded, 3-prong outdoor GFI outlet is to be located inside the island cabinet and to the left of the side burner. See “Electrical Requirements” section.

A. 24" (61 cm) B. 10⁵⁄₈" (27 cm) C. 28" (71.1 cm) D. 20¹⁄₂" (52.1 cm)
E. 19¹⁄₂" (49.5 cm) F. Manifold pipe G. 4³⁄₈" (11.1 cm) H. 17" (43.2 cm)
This built-in outdoor side burner is for installation in a built-in enclosure constructed of combustible and non-combustible materials. Some types of non-combustible materials could be brick, firewall or steel. Some types of combustible materials could be wood or laminate. The enclosure for the built-in outdoor side burner is to be a minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x 14" (35.6 cm) wide for front to back model and 11" (28.0 cm) high x 17" (43.2 cm) deep x 25" (63.5 cm) wide for side by side model.
Cabinet Dimensions Counter or support surfaces must be level. The installation of this side burner must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
A. 13" (33 cm) B. 10⁵⁄₈" (27 cm) C. 17" (43.2 cm) D. 26³⁄₈" (67 cm)
E. 25³⁄₈" (64.5 cm) F. Manifold pipe G. 4³⁄₈" (11.1 cm) H. 22³⁄₄" (57.8 cm)
Copies of the standards listed may be obtained from: CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575

The dimension chart and illustration below include cutout dimensions and minimum spacing requirements for all built-in outdoor products. The illustration is for reference. The design of your cabinet layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed.

Minimum Spacing Requirement Between Cutouts - Dimension K
Between 2 or more sets of Access Doors adjacent to each other: K = 14" (35.6 cm) when 2 adjacent doors are opened to 90 degrees K = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees Between a set of Access Doors and a Trash Drawer, Utility Drawer, Warming Drawer, Refrigerator, or Ice Maker: K = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees Between a Trash Drawer, Utility Drawer, or Warming Drawer: K = 3" (7.6 cm)
Cabinet Height and Depth Dimensions
Dimension A Minimum Dimension B Minimum
With outdoor refrigerator 37" (94.0 cm) 26" (66.0 cm)
Grill with insulated jacket 36½" (92.7 cm) 27" (68.6 cm)
Grill without insulated jacket 35½" (90.2 cm) 26" (66.0 cm)

Cutout Dimensions - Built-in Grill
Grill Size Dimension C Dimension D Dimension E
27" (68.6 cm) 29⁵⁄₈" (75.2 cm) 10¾" (27.3 cm) 22⁷⁄₈" (58.1 cm)
36" (91.4 cm) 38⁵⁄₈" (98.1 cm) 10¾" (27.3 cm) 22⁷⁄₈" (58.1 cm)
48" (121.9 cm) 50⁵⁄₈" (128.6 cm) 10¾" (27.3 cm) 22⁷⁄₈" (58.1 cm)
Cutout Dimensions - Built-in Grill with Insulated Jacket
Grill Size Dimension C Dimension D Dimension E
27" (68.6 cm) 33" (83.8 cm) 11¾" (29.8 cm) 24" (61.0 cm)
36" (91.4 cm) 42" (106.7 cm) 11¾" (29.8 cm) 24" (61.0 cm)
48" (121.9 cm) 54" (137.2 cm) 11¾" (29.8 cm) 24" (61.0 cm)
Cutout Dimensions - Built-in Side Burner
Burner Position Dimension C Dimension D Dimension E
Front to Back 13½" (34.3 cm) 10¾" (27.3 cm) 22⁵⁄₈" (57.5 cm)
Side by Side 24½" (62.2 cm) 10¾" (27.3 cm) 16⁷⁄₈" (42.9 cm)
Cutout Dimensions - Built-in Sear Burner
Dimension C Dimension D Dimension E
13½" (34.3 cm) 10⁵⁄₈" (27.0 cm) 22¹¹⁄₁₆" (57.6 cm)
Cutout Dimensions - Built-in Refreshment Center
Dimension C Dimension D Dimension E
30½" (77.5 cm) 10¾" (27.3 cm) 23" (58.4 cm)
Cutout Dimensions - Built-in Access Doors
Door Size Dimension F Dimension L*
18" (45.7 cm) 16³⁄₁₆" (41.1 cm) 1½" (3.8 cm)
27" (68.6 cm) 25¹⁄₈" (63.8 cm) 1½" (3.8 cm)
30" (76.2 cm) 28¹⁄₈" (71.4 cm) 1½" (3.8 cm)
36" (91.4 cm) 34¹⁄₈" (86.7 cm) 1½" (3.8 cm)
48" (121.9 cm) 46¹⁄₈" (117.2 cm) 1½" (3.8 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Cutout Dimensions - Outdoor Refrigerator
Dimension G Dimension H
24" (61.0 cm) 35¼" (89.5 cm)
Cutout Dimensions - Outdoor Ice Maker
Dimension G Dimension H
18" (45.7 cm) 34" (86.4 cm) min. to 34½" (87.6 cm) max.

Cutout Dimensions - Built-in Warming Drawer
Warming Drawer Size Dimension J
24" (61.0 cm) 22½" (57.2 cm)
Cutout Dimensions - Built-in Utility Drawer and Built-in Trash Drawer
Dimension M Dimension L*
12¼" (31.1 cm) 1½" (3.8 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Built-in Outdoor Grill Enclosure Ventilation for LP Gas: An enclosure for an LP gas fuel tank is to be ventilated by openings at both the top and lower levels of the enclosure. If converting to LP gas these vents are to be in the enclosure: An enclosure for use with an LP gas fuel tank for built-in installation is to have at least one ventilation opening on an exposed exterior side located within 5" (12.7 cm) of the top is to be a minimum of 20 in.2 (129.0 cm2). One ventilation opening within 1" (2.5 cm) of the bottom of the enclosure and the bottom opening is to be a minimum of 10 in.2 (64.5 cm2). All vent openings are to be unobstructed. Every opening is to be a minimum of ¹⁄₈" (0.32 cm) wide.
20 in.2 (129.0 cm2) min. ventilation both sides
5" (12.7 cm) max.
1" (2.5 cm) max.
10 in.2 (64.5 cm2) min. ventilation both sides
5" (12.7 cm) max.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
The model/serial number rating plate is located on the right-hand side panel. See the following illustration.
Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure whether the side burner is properly grounded. A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is required. It is recommended that a separate circuit servicing only this side burner be provided.
A. Model/serial number plate
Electrical Shock Hazard

Gas Conversion: No attempt shall be made to convert the side burner from the gas specified on the model/serial rating plate for use with a different gas type without consulting the serving gas supplier. The conversion kits supplied with the side burner must be used. See “Gas Conversions” section for instructions.
The outdoor side burner, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575
The gas pressure regulator supplied with this side burner must be used. The inlet (supply) pressure to the regulator should be as follows for proper operation: LP Gas: Set pressure: 11" (27.9 cm) WCP Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP Natural Gas: Set pressure: 4" (10.2 cm) WCP Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP maximum. Contact local gas supplier if you are not sure about the inlet (supply) pressure.
National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269
Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m). For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice conversion is required. See “Assistance or Service” section to order.
A. 3 prong ground plug B. 3-prong polarized type outdoor GFI outlet C. Ground prong
Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge): The side burner and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than ½ psi (3.5 kPa). Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or lower: The side burner must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
Use a new CSA International approved “outdoor” gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.
This side burner is equipped for use with a 20 lb LP gas fuel tank (fuel tank not supplied). A gas pressure regulator/hose assembly is supplied. It is also design-certified by CSA International for local LP gas supply or for Natural gas with appropriate conversion.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances. IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest edition. IMPORTANT: The side burner must be connected to a regulated gas supply. Refer to the model/serial rating plate for information on the type of gas that can be used. If this information does not agree with the type of gas available, check with your local gas supplier.
A. Gas pressure regulator/hose assembly
Explosion Hazard

The 20 lb LP gas fuel tank must be mounted and secured. Door Style Tank Tray 1. Open cabinet doors. 2. Pull out the tank tray.
The gas supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the side burner and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the side burner.
A. Gas supply line B. Shutoff valve “open” position C. To side burner
Conversion must be made by a qualified gas technician. The qualified Natural gas technician shall provide the Natural gas supply to the selected side burner location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For conversion to Natural gas, the Natural gas conversion kit supplied with the side burner must be used. IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. To convert to Natural gas, the Natural Gas Conversion Kit supplied with the side burner must be used. Follow instructions for converting to Natural gas in the “Gas Conversions” section.
A. Locking screw B. Mounting hole C. Bottom collar
Conversion must be made by a qualified gas technician. The qualified gas technician shall provide the gas supply to the selected side burner location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For conversion to local LP, the convertible regulator in the conversion kit supplied with the side burner must be used. IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified LP gas technician shall provide the LP gas supply to the selected side burner location in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and local codes. Follow instructions for converting to local LP gas in the “Gas Conversions” section.
A. New CSA International approved
“outdoor” flexible gas supply line B. Rear of side burner C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the side burner and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the side burner.
A. Gas supply line B. Shutoff valve “open” position C. To side burner
A. New CSA International approved
“outdoor” flexible gas supply line B. Rear of side burner C. To local LP gas supply
Tank tray

Natural Gas
LP Gas Conversion Using a Local LP Gas Supply
Built-in side burner models are equipped for use with Natural gas. They are design-certified by CSA International for LP (propane or butane) gases with appropriate conversion. Built-in models are set for Natural gas use and have a pressure regulator with ½" female pipe threads.
Conversion must be made by a qualified person. A qualified Natural gas technician shall provide the LP gas supply to the selected side burner location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. To convert to LP gas, the LP Gas Conversion Kit Part Number W10118099 must be used. Follow instructions included with kit.


A. Side burner gas pipe B. New CSA International approved
“outdoor” flexible gas supply line C. Rear of side burner D. To Natural gas supply
A. Side burner gas pipe B. New CSA International approved
“outdoor” flexible gas supply line C. Rear of side burner D. To local gas supply
The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the side burner and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the side burner.
To convert to LP gas, the LP Gas Conversion Kit Part Number W10118099 must be used. Follow instructions included with kit. A 20 lb LP gas fuel tank must be purchased separately.
A. Gas supply line B. Shutoff valve “open” position C. To side burner


Use two or more people to move and install side burner.
Failure to do so can result in back or other injury.
A. Top nut B. Tank tray C. Bottom nut D. Bolt
E. Mounting bracket
For Models Equipped for Use with a 20 lb LP Tank 1. Position the tank tray for 20lb LP gas fuel tank in the island cabinet.


A. Screw (Use proper screw for island floor material.) B. Lock washer C. Flat washer
18³⁄₈" (46.7 cm) 20⁵⁄₈" (52.4 cm)

Front to back burner 8³⁄₃₂" (20.6 cm) 16³⁄₁₆" (41.1 cm)
Side by side burner 12⁹⁄₁₆" (31.9 cm) 25¹⁄₈" (63.8 cm)
A. 20 lb LP gas fuel tank B. Tank tray for 20 lb gas fuel tank C. Top nut (do not tighten) D. Mounting bracket

7. The tank tray for the 20 lb LP gas fuel tank must be adjusted so that the bottom of the tank tray is ¹⁄₈" (0.32 cm) above the cabinet door opening and is level. The top nut on each of the mounting brackets is to be loose. Turn the bottom nuts counterclockwise to raise the tank tray and turn the bottom nuts clockwise to lower the tank tray. When the tank tray is level and slides in and out without touching the cabinet door opening at the bottom or top with the 20 lb LP tank installed, tighten the top nuts against the adjustment flange.
To Install the 20 lb LP Gas Fuel Tank: 1. Open cabinet doors. 2. Pull out the tank tray.
A. Top nut loosened B. Top nut tightened
A. Locking screw B. Mounting hole C. Bottom collar
Gas Connection to a 20 lb LP Gas Fuel Tank
Use a new CSA International approved “outdoor” gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. 20 lb LP gas fuel tank B. Gas pressure regulator/hose assembly
If converting to local LP or Natural gas, follow the instructions in the “Gas Conversions” section. IMPORTANT: A 20 lb LP gas fuel tank must be purchased separately. IMPORTANT: The gas pressure regulator/hose assembly supplied with the side burner must be used. Replacement gas pressure regulator/hose assembly specific to your model, is available from your outdoor side burner dealer.


A. Closed valve B. Open valve
Use a new CSA International approved “outdoor” gas supply line.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 - latest edition, or CAN/CGA-B149.1 Natural Gas and Propane installation code. Copies of the standards listed above may be obtained from: CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269 1. Make gas connections. A combination of pipe fittings must be used to connect the side burner to the existing gas line.
2. Locate or build a non-combustible surface inside the island cabinet to mount the power transformer. It must be to the left side of the side burner at a minimum of 3" (7.6 cm) from the side and 4" (10.2 cm) below the bottom of the side burner. 3. Mount the power transformer to the mounting surface using 4 #8 screws (not supplied) that are the proper type and length for the transformer and the mounting surface. It must be mounted with the wire for the single-prong plug upward or toward the side burner. NOTE: The cord must be properly mounted with a cord retention device so that its 3-prong plug will not touch the ground when it is unplugged.
A. New CSA International approved
“outdoor” flexible gas supply line B. Rear of side burner C. To Natural gas or Local LP gas supply
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
A. Cover B. Grate
Electrical Shock Hazard

GAS CONVERSIONS For Models Equipped for Use with a 20 lb LP gas Tank NOTE: Models that are equipped for Natural gas require Gas Conversion Kit Part Number W10118099 for conversion to LP gas. Use the conversion instructions included in the kit. See “Assistance or Service” section for information on ordering.
Tools and Parts for Gas Conversion Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Conversion to a Local LP Gas Supply Installation of the regulator 1. Turn off the main gas supply valve. 2. Unplug side burner or disconnect power. 3. Disconnect 20 lb LP gas fuel tank (if present). 4. Turn off all burner control valves. 5. Remove rear cover and 2 screws.


Use a new CSA International approved “outdoor” gas supply line.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
A. Manifold B. Brass elbow C. Rear of side burner D. Gas pressure regulator/hose assembly
licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Installation of the regulator 1. Turn off the main gas supply valve. 2. Unplug side burner or disconnect power. 3. Disconnect 20 lb LP gas fuel tank (if present). 4. Turn off all burner control valves. 5. Remove rear cover and 2 screws.
A. Brass connector B. Convertible regulator

A. Manifold B. Brass elbow C. Rear of side burner D. Gas pressure regulator/hose assembly
Connect Local LP Gas Supply 1. Use pipe wrench to connect certified ½" (1.3 cm) gas supply pipe to inlet side of regulator from Fixed LP gas supply according to local codes requirements. Use pipe thread sealant that is certified for use with LP gas at connections where required. There must be a certified manual shutoff valve in the gas supply line near the side burner for easy access. 2. Turn on the gas supply to the side burner. 3. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leaks found.
Record Conversion In the last page of the Use and Care Guide, write “Converted to Local LP Gas Supply.” Also record the conversion date and the technician/company that performed the conversion.

A. Brass elbow B. Convertible regulator

A. Burner top notches B. Burner base tabs
Hook up to Natural gas and Leak Test 1. Use pipe wrench to connect certified ¹⁄₂" (1.3 cm) gas supply pipe to inlet side of regulator from Natural gas supply according to local codes requirements. Use pipe thread sealant that is certified for use with LP gas at connections where required. There must be a certified manual shutoff valve in the gas supply line near the grill for easy access. 2. Turn on the gas supply to the grill. 3. Test all connections using an approved noncorrosive leak- detection solution. Bubbles will show a leak. Correct any leak found.
Record Conversion 1. The appliance nameplate is located inside the grill cabinet on the right-hand cabinet side. With a permanent marker, check the box next to “Natural gas” and mark through “LP - Propane.” In the last page of the Use and Care Guide, write “Converted to Natural Gas.” Also record the conversion date and the technician/company that performed the conversion. NOTE: Place LP gas parts in plastic parts bag for future use and keep with pack containing literature.
Change the Side burner orifices 1. Remove the side burner grates. 2. Remove the burner caps. The caps are interlocked to the burner base. Twist and lift the burner caps to remove. 3. Use 10 mm socket and wrench or 10 mm nut driver to remove the brass orifices from inside the burner base.
Check and Adjust the Burners The burners are tested and factory-set for most efficient operation. However, variations in gas supply and other conditions may make minor adjustments to low flame setting necessary. It is recommended that a qualified person make burner adjustments.

³⁄₄" - 1" (1.9 - 2.5 cm) on all burner ports with burners on "HI" setting

If flame goes out on the “LO” setting, the low flame setting must be adjusted. 1. Turn off the valve and wait until burners are cool. 2. Light side burner using information in the “Outdoor Side Burner Use” section. 3. Turn burner to its lowest setting and remove knob. 4. Hold valve stem with pliers and insert a small flat-blade screwdriver into the shaft. 5. Watch the flame and slowly turn the screwdriver counterclockwise.
A. Valve stem B. Small flat-blade screwdriver C. Pliers
Lighting Your Side Burner
Inspect the gas pressure regulator/hose assembly before each use. 1. Open the cabinet door and slide 20 lb LP gas fuel tank out. 2. Inspect the entire gas pressure regulator/hose assembly for cuts, abrasions, or excessive wear. 3. If necessary, replace the gas pressure regulator/hose assembly before using the side burner. Contact the dealer and use only replacement hoses specified for use with the side burner.
Do not let the burner flame extend beyond the edge of the pan.
Doing so can result in burns.
A. Gas pressure regulator/hose assembly
Do not let food sit for more than one hour before or after cooking.
Doing so can result in food poisoning or sickness.
1. For outdoor side burners using a 20 lb LP gas fuel tank: Slowly open the tank valve. NOTE: If flow limiting device activates, your side burner may not light. If your side burner does light, the flames will be low and will not heat properly. Turn 20 lb LP gas fuel tank valve and all control knobs off and wait 30 seconds. After shutting off the 20 lb LP gas fuel tank, very slowly open tank valve and wait 5 seconds before lighting.
Burn Hazard · Food Poisoning Hazard

General Cleaning IMPORTANT: Before cleaning, make sure all controls are off and the side burner is cool. Always follow label instructions on cleaning products. For routine cleaning, wash with soap and water using a soft cloth or sponge. Rinse with clean water and dry at once with a soft, lint-free cloth to avoid spots and streaks. Do not use steel wool to clean the side burner, as it will scratch the surface. To avoid weather damage to finish, use stainless steel side burner cover.
The quality of this material resists most stains and pitting, providing that the surface is kept clean, polished and covered.
Discoloration of stainless steel on these parts is to be expected, due to intense heat from the burners. Always rub in the direction of the grain. Cleaning should always be followed by rinsing with clean, warm water. Cleaning Method:

KNOBS AND FLANGE AREA AROUND KNOBS
Cleaning Method:
Try the solutions suggested here first in order to avoid the cost of an unnecessary service call.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Before calling for assistance or service, please check “Troubleshooting.” It may save you the cost of a service call. If you still need help, follow the instructions below. When calling, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request.
If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. These factory specified parts will fit right and work right because they are made with the same precision used to build every new KITCHENAID® appliance. To locate factory specified parts in your area, call us or your nearest KitchenAid designated service center.
Electrical Shock Hazard

In the U.S.A. Call the KitchenAid Customer eXperience Center toll free: 1-800-422-1230. Our consultants provide assistance with:
Kitchen and BBQ Grill Degreaser Order Part Number 31617
In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800-807-6777. Our consultants provide assistance with:
To locate the KitchenAid designated service company in your area, you can also look in your telephone directory Yellow Pages.
For further assistance If you need further assistance, you can write to KitchenAid with any questions or concerns at:
KitchenAid Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor, MI 49022-2692
For further assistance If you need further assistance, you can write to KitchenAid Canada with any questions or concerns at:
Please include a daytime phone number in your correspondence.
Customer eXperience Centre KitchenAid Canada 1901 Minnesota Court Mississauga, Ontario L5N 3A7
Please include a daytime phone number in your correspondence.
LIMITED WARRANTY For one year from the date of purchase, when this outdoor product is operated and maintained according to instructions attached to or furnished with the product, KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter “KitchenAid”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. This limited warranty is valid only in the United States or Canada and applies only when the outdoor product is used in the country in which it was purchased. Outside the 50 United States and Canada, this limited warranty does not apply. Proof of original purchase date is required to obtain service under this limited warranty.
SECOND THROUGH FIFTH YEAR LIMITED WARRANTY ON PARTS ON GRILLS ONLY In the second through fifth years from the date of purchase when this grill is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for Factory Specified Parts to correct defects in materials or workmanship.
LIFETIME LIMITED WARRANTY ON STAINLESS STEEL COMPONENTS ON GRILLS ONLY For the life of the product, when this grill is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for replacement of the stainless steel body housing due to defective materials or workmanship. For the life of the product, when this grill is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for replacement parts for the stainless steel grill burners.
ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover: 1. Service calls to correct the installation of your outdoor product, to instruct you on how to use your outdoor product, to replace or repair house fuses, or to correct house wiring or plumbing. 2. Cosmetic damage, including scratches, dents, chips or other damage to the finish of your outdoor product, unless such damage results from defects in materials or workmanship and is reported to KitchenAid within 30 days from the date of purchase. 3. Repairs when your outdoor product is used for other than normal, single-family household use or when it is used in a manner that is contrary to published user or operator instructions and/or installation instructions.

4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with electrical or plumbing codes, or use of consumables or cleaning products not approved by KitchenAid. 5. Conversion kit or service call for the conversion of your outdoor product from natural gas to L.P./propane or from L.P./propane to natural gas. 6. Costs associated with the removal from your home of your outdoor product for repairs. This outdoor product is designed to be repaired in the home and only in-home service is covered by this warranty. 7. Repairs to parts or systems resulting from unauthorized modifications made to the outdoor product. 8. Expenses for travel and transportation for product service if your outdoor product is located in a remote area where service by an authorized KitchenAid servicer is not available. 9. The removal and reinstallation of your outdoor product if it is installed in an inaccessible location or is not installed in accordance with published installation instructions. 10. Damage resulting from normal wear and tear of your outdoor product. 11. Outdoor products with original model/serial numbers that have been removed, altered or cannot be easily determined. This warranty is void if the factory applied serial number has been altered or removed from your outdoor product. The cost of repair or replacement under these excluded circumstances shall be borne by the customer.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE.
If outside the 50 United States and Canada, contact your authorized KitchenAid dealer to determine if another warranty applies. If you need service, first see the “Troubleshooting” section of the Use & Care Guide. After checking “Troubleshooting,” you may find additional help by checking the “Assistance or Service” section or by calling KitchenAid. In the U.S.A., call 1-800-422-1230. In Canada, call 1-800-807-6777. 9/07
Keep this book and your sales slip together for future reference. You must provide proof of purchase or installation date for in-warranty service. Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it. You will need to know your complete model number and serial number. You can find this information on the model and serial number label located on the product.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.