15-Jul y -200 4 1 KP-FD30 remote control protocol (Rev .1) 1) Comms* s pecificati ons Sync system S tart-stop sync Bit rate 9600 bps Data length 8 bits S tart bit 1 S top bits 1 Parity None Bit transf er LSB first *Comms : Communications 2) Comms control The remote control software controls all communications.
15-Jul y - 2004 2 a) T ransmission f rom master (norm al proc ess) Master Slave ENQ code (05H) 1) ACK code (06H) Transmit code (ASCII code) 2) 3) 4) ACK code (06H) 1) Session starts w hen ENQ is sent from master to slave. 2) Slave acknowledges by returning ACK to master .
15-Jul y - 2004 3 b) Master reads data ( normal pr ocess) Master Slave ENQ code (05H) 1) ACK code (06H) Read command (ASCII code) ACK code (06H) 2) 3) 4) Read data (ASCII code) ACK code (06H) 5) 6) 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 4 c) Data transmitted by master (control abort pro cess) Master Slave ENQ code (05H) 1) NAK code (15H) 2) 3) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) 1) Master sends ENQ code to slave. 2) Since ACK code cannot be sent, slave sent NAK code to maste r .
15-Jul y - 2004 5 d) Data transmitted by master (data error proc ess) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (error occurs) ACK code (06H) Send data (error occurs) Send data (data normal) 4) 3 seconds elaps e 3 seconds elapse 5) 6) 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 6 e) Data f ram e error ( Master trans mission) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (ASCII code) 4) 3 seconds elaps e 3 seconds elaps e 5) 6) Send data (ASCII code) Send data (ASCII code) Send data (ASCII code) 3 seconds elaps e 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 7 f) T ransmission f r ame er ror (M aster receiv e) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Read command (ASCII code) 4) 3 seconds elapse 5) 6) ACK code (06H) Read command.
15-Jul y - 2004 8 (4) Comm s command T ext d ata format a) Send data and r ea d command dat a (master to slave) 1) Command data are converted into ASCII code and t ransmitted. 2) Com ms byte quanti ty is 18. 3) Comms data format (transmission seq uence).
15-Jul y - 2004 9 b) Read (receive) dat a ( slave to master) 1) Command data are converted into ASCII code and t ransmitted. 2) Com ms byte quanti ty is 10. 3) Comms data format (transmission seq uence) STX Text data ETX SUM 10 bytes ■ Comm s data descript ion ・ STX : Code indicating start of text.
15-Jul y - 2004 1 KP-FD30 remote control command table (Rev.1) 1) Standard command a) Write comm and (Set da ta) TEXT data Item STX Status ID Area R.No Data ETX SUM AVE (*) 02 01 FF 01 3A 00 00 00 03 18 AREA 02 01 FF 01 3A 01 00 00 03 17 Auto Light C ontrol M ode (ALC) PEAK/AVE 02 01 FF 01 3A 00 00 00 03 16 NO.
15-Jul y -200 4 2 TEXT data Item STX Status ID Area R.No Data ETX SUM OFF (*) 02 01 FF 01 17 00 00 00 03 24 PRESET 02 01 FF 01 17 01 00 00 03 23 VARIABL 02 01 FF 01 17 02 00 00 03 22 AES 02 01 FF 01 17 03 00 00 03 21 Shutter Mode (SHU TTE R) EXT T IG 02 01 FF 01 17 04 00 00 03 20 8.
15-Jul y - 2004 3 TEXT data Item STX Status ID Area R.No Data ETX SUM 1/20000 s 02 01 FF 01 08 22 00 00 03 20 1/30000 s 02 01 FF 01 08 23 00 00 03 1F 1/50000 s 02 01 FF 01 08 24 00 00 03 1E 1/60 s(Min.
15-Jul y -200 4 4 TEXT data Item STX Status ID Area R.No Data ETX SUM A W C(PRESET) restart 02 00 FF 01 07 00 00 00 03 26 Min 02 01 FF 01 36 00 00 00 03 23 | 02 01 FF 01 36 ** 00 00 03 ** Mid (*) 02 0.
15-Jul y -200 4 5 TEXT data Item STX Status ID Area R.No Data ETX SUM OFF ( γ =1.0 ) 02 01 FF 01 14 00 00 00 03 27 GAMMA ON ( γ =0.45) (*) 02 01 FF 01 14 01 00 00 03 26 POSITIVE (*) 02 01 FF 01 01 0.
15-Jul y -200 4 6 Charcter C ode 0 ( 3 0 ) A ( 4 1 ) K ( 4 B ) U ( 5 5 ) ! ( 2 1 ) ~ ( 7 D ) 1 ( 3 1 ) B ( 4 2 ) L ( 4 C ) V ( 5 6 ) ? ( 3 F ) * ( 2 A ) 2 (32) C (43) M (4D) W (57) # (A2) % (25) 3 ( 3.
15-Jul y -200 4 7 b) Read Command (Read data) TEXT data Item STX Status ID Area R.No Data ETX SUM Auto Light C ontrol M ode (ALC) 02 01 FF 81 3A 00 00 00 03 10 Area of Light m easurement (ALC : AREA) .
15-Jul y -200 4 8 TEXT data Item STX Status ID Area R.No Data ETX SUM 1 st & 2 nd charac ters 02 01 FF 81 1E 00 00 00 03 0E 3 rd & 4 th chara cters 02 01 FF 81 1F 00 00 00 03 0D 5 th & 6 t.
15-Jul y -200 4 9 2) Special command (Fo r adjustmen t of a facto ry) Caution ! ! ▪ The item indicate d by the special c omm and is adjusted to the optim al value at the tim e of fac tory shipm ents. Please p erform after reading t he data se t up now b y the lead com mand an d mem orizing a set ting val ue, when c hanging th is item .
15-Jul y -200 4 10 TEXT data Item STX Status ID Area R.No Data ETX SUM Min 02 00 FF 02 9D 00 00 00 03 0F | 02 00 FF 02 9D ** ** 00 03 ** C-Y M atri x (Gb- y,r-g[+]) [0000-01FF] Max 02 00 FF 02 9D FF 0.
15-Jul y -200 4 11 b) Read Command (Read data) TEXT data Item STX Status ID Area R.No Data ETX SUM Standard sens itivity adjustm ent (Standard Gain) 02 01 FF 81 2E 00 00 00 03 0D ALC Level Ref . 02 01 FF 81 19 00 00 00 03 1A Peak data Ref. 02 01 FF 81 3F 00 00 00 03 0B Auto Iris Ref.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hitachi KP-FD30 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hitachi KP-FD30 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hitachi KP-FD30, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hitachi KP-FD30 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hitachi KP-FD30, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hitachi KP-FD30.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hitachi KP-FD30. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hitachi KP-FD30 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.