FR
Broan logo
Notice d'utilisation officielle

Broan RM52000

36 pages·881 KB·Hotte de ventilation·PDF·ENDEITNLJA
Broan RM52000
Table des matières 70 sections RM51000 RM52000 Series · READ AND SAVE THESE INSTRUCTIONS WARNING · WARNING · CAUTION · … AfficherMasquer
Page 1 of the Broan RM52000 user manual — ENGLISH......................................3 FRANÇAIS.................................12 ESPAÑOL...................................21
Page 1 · cliquer pour agrandir
Page 1

RM51000 RM52000 Series

Broan RM52000 — RM51000 RM52000 Series diagram (page 1)
Fig. 1 · RM51000 RM52000 Series
Broan RM52000 — RM51000 RM52000 Series diagram (page 1)
Fig. 2 · RM51000 RM52000 Series
Broan RM52000 — RM51000 RM52000 Series diagram (page 1)
Fig. 3 · RM51000 RM52000 Series

ENGLISH 3 FRANÇAIS 12 ESPAÑOL 21

Broan-NuTone LLC. 926 West State Street, Hartford, WI 53027 NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 Broan-NuTone Canada, INC.1140 Tristar Drive, Mississauga, Ontario, L5T 1H9

Page 2 of the Broan RM52000 user manual — RM51000 RM52000 Series
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Broan RM52000 user manual — RM51000 RM52000 Series
Page 3 of the Broan RM52000 user manual — CAUTION
Page 3 · cliquer pour agrandir
Page 3

READ AND SAVE THESE INSTRUCTIONS WARNING

WARNING

SUITABLE FOR USE IN HOUSEHOLD COOKING AREA.

TO REDUCE THE RISK OF INJURY TO PER- SONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extin-

1. Use this unit only in the manner intended by the manufacturer. If you have questions, con- tact the manufacturer at the address or tele- phone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ- ing fire-rated construction codes and stan- dards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chim- ney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety stan- dards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the out- doors. 7. Do not use this unit with any solid-state speed control device. 8. To reduce the risk of fire, use only steel ductwork. 9. This unit must be grounded.

guisher and you already know how to op- erate it. B. The fire is small and contained in the area

where it started. C. The fire department is being called. D. You can fight the fire with your back to an

exit. * Based on “Kitchen Fire Safety Tips” pub- lished by NFPA.

CAUTION

1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking sur- face. 8. Two installers are recommended because of the large size and weight of this hood. 9. Please read specification label on product for further information and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or

when cooking flaming foods. C. Clean ventilating fans frequently. Grease should not

be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate

for the size of the surface element.

Page 4 of the Broan RM52000 user manual — 8 DRYWALL ANCHORS
Page 4 · cliquer pour agrandir
Page 4

PREPARE THE HOOD

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 8 - Mounting Screws (4,8 x 38mm Pan Head) 5 - Mounting Screws (3,9 x 9,5mm Pan Head) 8 - Drywall Anchors 1 - Installation Instructions

Broan RM52000 — PREPARE THE HOOD diagram (page 4)
Fig. 4
Broan RM52000 — PREPARE THE HOOD diagram (page 4)
Fig. 5
Broan RM52000 — PREPARE THE HOOD diagram (page 4)
Fig. 6

MOUNTING BRACKET

DECORATIVE FLUE (RM51000 model)

DECORATIVE FLUE (RM52000 model)

5 MOUNTING SCREWS (3,9 x 9,5mm Pan Head)

DISCHARGE COLLAR

Broan RM52000 — DISCHARGE COLLAR diagram (page 4)
Fig. 7

FLUE MOUNTING BRACKET

8 MOUNTING SCREWS (4,8 x 38mm Pan Head)

8 DRYWALL ANCHORS

Page 5 of the Broan RM52000 user manual — MOUNTING
Page 5 · cliquer pour agrandir
Page 5

INSTALL THE DUCTWORK

Broan RM52000 — INSTALL THE DUCTWORK diagram (page 5)
Fig. 8

ROOF CAP

metal ductwork.

ROUND

DUCT

1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back to- wards hood location. Use duct tape to seal the joints between ductwork sections.

DECORATIVE

WALL

CAP

FLUE

HOOD

ROUND ELBOW

24” TO 30” ABOVE COOKING SURFACE

6 ” ADAPTER

INSTALL MOUNTING BRACKET

FRAMING BEHIND DRYWALL

Broan RM52000 — DECORATIVE diagram (page 5)
Fig. 9
1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over

38-1/16” to 44-1/16” above cooktop

installation location. b) the height of the framing will allow the

mounting bracket to be secured to the framing within the dimensions shown.

38-1/16"= bottom of hood 24" above cooktop 44-1/16"= bottom of hood 30" above cooktop

2. After wall surface is finished, secure mounting bracket to framing using dimensions shown.

INSTALL THE HOOD

MOUNTING

WALL FRAMING

Broan RM52000 — MOUNTING diagram (page 5)
Fig. 10

SCREWS

1. Hang the hood from the bracket through the rectangular cut-out on the back of the hood. Cut-out is larger than the bracket to allow for horizontal adjustment. The bottom of the hood should be 24" to 30" above the cooking surface. 2. Secure the hood with mounting screws . Use drywall anchors, provided, if wall studs or framing are not available.

MOUNTING

SCREWS

MOUNTING

BRACKET

RECTANGULAR

CUTOUT

Page 6 of the Broan RM52000 user manual — THE ELECTRICAL
Page 6 · cliquer pour agrandir
Page 6

MOUNT THE PLATE

PLATE OF

Mount the plate of the electrical system attaching it with 3 screws.

Broan RM52000 — PLATE OF diagram (page 6)
Fig. 11

THE ELECTRICAL

SYSTEM

WIRING

Broan RM52000 — THE ELECTRICAL diagram (page 6)
Fig. 12

Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Set the electrical power supply within the space covered by the decorative flues. Position the power socket at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration alongside). Make sure this does not interfere with the bracket fastening area or with the decorative flue (where the flue touches the wall). Fit the plug into the power socket.

Page 7 of the Broan RM52000 user manual — FLUE MOUNTING
Page 7 · cliquer pour agrandir
Page 7

CONNECT DUCTWORK

FLUE MOUNTING

BRACKET

MOUNTING SCREWS

duct collar on the hood to the ductwork above. MOUNTING SCREWS 4. Use duct tape to make all joints secure and air tight. 5. Insert the decorative flues setting them on the hood. 6. Extend the upper flue to the ceiling and = secure with two mounting screws. = DECORATIVE FLUE DUCT TAPE FASTEN FLUE TO UPPER BRACKET WITH MOUNTING 6" ROUND SCREWS METAL DUCTMOUNTING SCREWS = = DECORATIVE FLUE DUCT TAPE 6" ROUND METAL DUCT FASTEN FLUE TO UPPER BRACKET WITH MOUNTING SCREWS
Broan RM52000 — FLUE MOUNTING diagram (page 7)
Fig. 13
Broan RM52000 — FLUE MOUNTING diagram (page 7)
Fig. 14
Broan RM52000 — FLUE MOUNTING diagram (page 7)
Fig. 15
Page 8 of the Broan RM52000 user manual — UPPER BRACKET
Page 8 · cliquer pour agrandir
Page 8

Non-ducted recirculation Configuration 1. Adjust the width of the flue mounting bracket to equal the inside width of decorative flue. Insert and tighten mounting screws to hold bracket width. 2. Use mounting screws and wall anchors to secure flue mounting bracket to the ceiling as shown.

FLUE MOUNTING

BRACKET

MOUNTING SCREWS

3. Turn upper flue section upside down so air vents are at the top. Slide upper flue section into lower flue section. 4. Connect the non-ducted recirculation plenum to the upper flue section with (4) flat-head screws (supplied). 5. Install the reduction on the discharge collar. 6. Measure the distance from the top of the reduction to the ceiling. Cut a length of 5" round metal duct 5" shorter than this dimension. 7. Fit duct section over the non-ducted recirculation plenum. For best fit, make sure duct seam is toward the front. 8. Set duct/flue assembly on hood with top tilted away from wall. Reach around flue to engage bottom of duct with discharge collar on hood. Tilt flue up against wall. Duct seam can be cut to length if necessary. 9. Extend the upper flue to the ceiling and secure with two mounting screws.

MOUNTING SCREWS

AIR VENTS (in upper flue section)

UPPER BRACKET

UPPER FLUE SECTION

FASTEN FLUE TO

Broan RM52000 — UPPER BRACKET diagram (page 8)
Fig. 16

UPPER BRACKET

WITH MOUNTING

NON-DUCTED RECIRCULATION

SCREWS

PLENUM

LOWER FLUE SECTION

5" ROUND METAL DUCT

DUCT SEAM

MEASURE

REDUCTION

DISCHARGE

COLLAR

Show 4 more labels / short text on this page
= · = · ! · !
Page 9 of the Broan RM52000 user manual — CLAMP
Page 9 · cliquer pour agrandir
Page 9

NON-DUCTED RECIRCULATION FILTER INSTALLATION

Broan RM52000 — NON-DUCTED RECIRCULATION FILTER INSTALLATION diagram (page 9)
Fig. 17
1. Purchase a charcoal filter (B03300488) from your dealer.
2. Install the filter by pressing the 2 tabs on the filter down into the special housing and rotating upward. CHARCOAL

FILTER

MAINTENANCE

Broan RM52000 — FILTER diagram (page 9)
Fig. 18

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filters The grease filters should be cleaned fre- quently. Use a warm detergent solution. Grease filters are dishwasher safe. Remove filter by pushing filter towards the back of hood and rotating filter downward.

GREASE FILTERS

TABS

Broan RM52000 — GREASE FILTERS diagram (page 9)
Fig. 19

Charcoal Filter The charcoal filter should be changed every 6 months. To remove the filter press inward on the clamp and rotate the filter downward until the 2 tabs can be removed from the housing.

CLAMP

Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help pre- serve its fine appearance. Cleaning tips:

  • Hot water with soap or detergent is all that is usually needed.
  • Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
  • For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
  • For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
  • DO NOT allow deposits to remain for long periods of time.
  • DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
  • DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.
Page 10 of the Broan RM52000 user manual — FUSE
Page 10 · cliquer pour agrandir
Page 10

OPERATION

LIGHT SWITCH

BLOWER

Controls The hood is operated using the slide controls under the bottom of the hood.

SWITCH

PILOT

LAMP

The light switch turns the lamps on and off.

The blower switch:makes it possible to select the motor operating speed. Position 0: motor off.

The pilot lamp lights up whenever the blower is on.

HALOGEN BULBS

Broan RM52000 — HALOGEN BULBS diagram (page 10)
Fig. 20

This range hood requires two halogen bulbs (Type T4, 12V, 20W). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

RING NUT

To change bulbs:

1. Loosen the ring nut by turning it counterclockwise. 2. Remove the bulb by pulling sideward(DO NOT ROTATE). CAUTION: BULB MAY BE HOT! 3. Replace with Type T4, 12V, 20W halogen bulb. Do not touch replacement bulb with bare hands!
Broan RM52000 — RING NUT diagram (page 10)
Fig. 21

FUSE REPLACEMENT

DECORATIVE FLUE

SWITCH OFF THE ELECTRICITY SUPPLY.

FUSE BOX

Remove the decorative flue.

Open the fuse box.

Replace with the same type of fuse (5x20mm, 4A, 125V).

FUSE

Page 11 of the Broan RM52000 user manual — WARRANTY
Page 11 · cliquer pour agrandir
Page 11

WARRANTY

BROAN-NUTONE LLC ONE YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WAR- RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC- TION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone LLC at the address stated below or telephone: 1-800-637- 1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC. 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada, Inc. 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1-888-882-7626)

Poser une question sur : Broan RM52000

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan RM52000

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan RM52000 manuel PDF

36 pages·881 KB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…