FR
Broan logo
Notice d'utilisation officielle

Broan QP130SSC

20 pages·1.6 MB·Hotte de ventilation·PDF·ENDEITNLJA
Broan QP130SSC
Table des matières 25 sections CAUTION · Register your product online at: www.broan.com/register · Page 2 OPERATION · CONTENTS · … AfficherMasquer
Page 1 of the Broan QP130SSC user manual — Register your product online at: www.broan.com/register
Page 1 · cliquer pour agrandir
Page 1
Broan QP130SSC — CAUTION diagram (page 1)
Fig. 1
  • MODELS QP130BL
  • QP130BLC
  • QP130SS
  • QP130SSC QP130WW
  • QP130WWC
  • QP136BL
  • QP136SS
  • QP136WW

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the ser- vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring (including switch loca- tion) must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Provide sufficient air for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the combustion equipment standards such as those published by the National Fire Pro- tection Association (NFPA), the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and local codes. 5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. Use only metal ductwork. 9. Do not use this fan with any solid-state speed control device. 10. As an alternative, this product may be installed with the UL- approved cord kit designated for the product, following in- structions packed with the cord kit. 11. This unit must be grounded.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN — You may be burned or spread the fire. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you

already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbal- anced impeller, keep drywall spray, construction dust, etc., off power unit. 4. Do not use over cooking equipment greater than 60,000 BTU/hr. as the blower motor will shut down intermittantly. 5. Your hood motor has a thermal overload which will automati- cally shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 6. The top of the hood MUST NOT BE LESS than 24” and at a maximum of 30” above cooktop for best capture of cooking impurities. 7. This hood is not intended to be used as a shelf. 8. Please read specification label on product for further infor- mation and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). 3. Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

Purchase a set of (2) non-ducted filters from your local distributor or retailer and attach them to the aluminum mesh filters.

Installer: Leave this manual with the homeowner. Homeowner: Cleaning, Maintenance and Operating

instructions on page 2.

Register your product online at: www.broan.com/register

Page 3 of the Broan QP130SSC user manual — 3 / 8 " 4 7/ 8 " *
Page 3 · cliquer pour agrandir
Page 3
  • MODELS QP130BL
  • QP130BLC
  • QP130SS
  • QP130SSC QP130WW
  • QP130WWC
  • QP136BL
  • QP136SS
  • QP136WW

PREPARE THE HOOD

2 Use the proper diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole. * Note the extra wood shim and mounting screw near the cabinet front, 4-7/8” to the right of the cabinet center line.

3 Remove parts bag from inside the foam packaging end cap.

Broan QP130SSC — PREPARE THE HOOD diagram (page 3)
Fig. 2

4 Remove all protective polyfilm from the hood (stainless steel hoods only).

Broan QP130SSC — PREPARE THE HOOD diagram (page 3)
Fig. 3

145/8" (36" hood) 115/8" (30" hood) 115/8" (30" hood)

ELECTRICAL ACCESS HOLE (in cabinet bottom) WOOD SHIMS (recessed-bottom

Broan QP130SSC — PREPARE THE HOOD diagram (page 3)
Fig. 4

3 / 8 " 4 7/ 8 " *

145/8" (36" hood) 115/8" (30" hood)

145/8" (36" hood) 115/8" (30" hood) 8½"

145/8" (36" hood) 115/8" (30" hood) 115/8" (30" hood)

6 Remove 2 screws holding Damper / Duct Connector to hood. Remove damper/duct connector from inside the hood.

FOR DUCTED INSTALLATIONS - Skip to Step 9.

Page 4 of the Broan QP130SSC user manual — INSTALL THE HOOD
Page 4 · cliquer pour agrandir
Page 4
  • MODELS QP130BL
  • QP130BLC
  • QP130SS
  • QP130SSC QP130WW
  • QP130WWC
  • QP136BL
  • QP136SS
  • QP136WW
Broan QP130SSC — INSTALL THE HOOD diagram (page 4)
Fig. 5
Broan QP130SSC — INSTALL THE HOOD diagram (page 4)
Fig. 6

7 NON-DUCTED INSTALLATION ONLY: Remove Center Retaining Screw and loosen Outer Retaining Screws holding Recirculation Slide Plate in place. Pull out slide plate and replace and tighten retaining screws to hold slide plate in new (non-ducted) position.

8 NON-DUCTED INSTALLATION ONLY: Purchase a set of (2) non-ducted filters from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.

10 DUCTED INSTALLATION ONLY: Attach 3¼” x 10” Damper/Duct Connector (if using 3¼” x 10” duct) or 7” Round Duct Plate (if using 7-inch round duct) over the knockout opening.

Note: To accomodate off-center ductwork, the 3¼” x 10” damper/ duct connector can be installed up to ½” on either side of the hood center and the 7” round duct plate can be installed up to ½” on either side of the hood center. Trim the flange on the duct connector or duct plate if it interferes with the electrical cable clamp. Install the 3¼” x 10” Damper/Duct Connector with the Damper Flap Pivot nearest the Top/Back Edge of Hood.

FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL THE HOOD”.

Broan QP130SSC — INSTALL THE HOOD diagram (page 4)
Fig. 7

INSTALL THE HOOD

Broan QP130SSC — INSTALL THE HOOD diagram (page 4)
Fig. 8

9 DUCTED INSTALLATION ONLY: Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate(s) as appropriate for your ducting method.

11 Remove Electrical Wiring Box Cover from inside of hood and appropriate Electrical Power Cable Knockout from top or back of hood.

Page 5 of the Broan QP130SSC user manual — CONNECT THE WIRING
Page 5 · cliquer pour agrandir
Page 5
  • MODELS QP130BL
  • QP130BLC
  • QP130SS
  • QP130SSC QP130WW
  • QP130WWC
  • QP136BL
  • QP136SS
  • QP136WW

INSTALL LIGHT BULBS

SUCTION CUP TOOL

HOUSE POWER CABLE

(1) PUSH IN

HALOGEN

BULB

(2) ROTATE CLOCKWISE

12 Run House Power Cable between service panel and hood location. Attach power cable to hood using appropriate clamp.

LIGHT PANEL

SCREWS LIGHT PANEL

13 Hang hood from (5) mounting screws driven part-way into cabinet locations (shown in illustrations under “PREPARE HOOD LOCATION”). Mounting screws are included in parts bag. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely.

16 Install (4) Halogen Bulbs. Use 120 V, 35 W, shielded halogen bulbs - MR16 with GU10 base. Purchase bulbs separately. NOTE: Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated. The position of the bulb socket (depth) is adjustable and may be necessary when: a) certain brands of bulbs are difficult to install. b) the bulb protrudes too far below the light panel.

14 DUCTED INSTALLATION ONLY: Connect ductwork to hood and use duct tape to make joints secure and air-tight. Make sure the damper / duct connector enters the ductwork and that the damper opens and closes freely.

Broan QP130SSC — LIGHT PANEL diagram (page 5)
Fig. 9

CONNECT THE WIRING

Broan QP130SSC — CONNECT THE WIRING diagram (page 5)
Fig. 10

To change the depth of bulb sockets: - Remove 2 Light Panel Screws. Set screws aside. - Loosen 2 Screws holding Lamp Socket Bracket to Light Panel. - Adjust socket/bracket to desired depth. - Re-tighten screws securely. - Re-attach light panel.

15 Connect House Power Cable to range hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or BARE WIRE to Ground Screw. Replace electrical wiring box cover.

17 DUCTED INSTALLATION ONLY: Re-install aluminum filters removed in Step 5.

NON-DUCTED INSTALLATION ONLY: Install aluminum filters and non-ducted filters - purchased and assembled in Step 8.

Page 6 of the Broan QP130SSC user manual — Replacement parts can
Page 6 · cliquer pour agrandir
Page 6
  • MODELS QP130BL
  • QP130BLC
  • QP130SS
  • QP130SSC QP130WW
  • QP130WWC
  • QP136BL
  • QP136SS
  • QP136WW

Page 6 SERVICE PARTS

WARRANTY

One Year Limited Warranty Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN- NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario Canada L5T 1H9 www.broan.ca 877-896-1119

Replacement parts can

now be ordered on our website. Please visit us

at www.broan.com

KEY NO. PART NO. DESCRIPTION

1 97017727 7” Round Duct Plate (includes mounting hardware) 2 97017729 Switch Assembly White (includes 2 switches, nameplate, mounting hardware) 97017730 Switch Assembly Black (includes 2 switches, nameplate, mounting hardware) 3 99526653 Nameplate, White 99526652 Nameplate, Black 4 97017736 Capacitor Kit (includes wire nuts, mounting screw) 5 97017753 Non-duct Slide, White (includes mounting hardware) 97017821 Non-duct Slide, Black (includes mounting hardware) 6 97017755 Light Panel RH White (includes mounting hardware) 97017756 Light Panel RH Black (includes mounting hardware) 97017757 Light Panel RH Stainless (includes mounting hardware)” 7 97017720 Filter Kit for 30”” Hood (2 per bag) 97017721 Filter Kit for 36”” Hood (2 per bag) 8 97017754 Venturi Ring (includes mounting hardware) 9 97017734 Blower Wheel (includes mounting nut) 10 97017732 Motor Kit (includes motor, isolators, mounting hardware) 11 97017728 Damper / Duct Connector (includes mounting hardware) 12 97017758 Light Panel LH White (includes mounting hardware) 97017759 Light Panel LH Black (includes mounting hardware) 97017760 Light Panel LH Stainless (includes mounting hardware) 13 97017731 Lamp Socket (includes lamp socket, wire nuts, mounting screws) 14 97018233 Lamp Socket Bracket (includes mounting hardware) Not Shown 97017735 Parts Bag Not Shown 99010353 Non-Duct Filter Kit for 30” Hood (2 charcoal filters and 8 filter clips) Not Shown 99010354 Non-Duct Filter Kit for 36” Hood (2 charcoal filters and 8 filter clips) Not Shown 99526707 Suction Cup Tool Not Shown 97018234 Light Diode (includes wire nuts) Not Shown 99526798 35W Halogen GU10 Bulb

Order replacement parts by PART NO. - not by KEY NO.

Poser une question sur : Broan QP130SSC

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan QP130SSC

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan QP130SSC manuel PDF

20 pages·1.6 MB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…