FR
Broan logo
Notice d'utilisation officielle

Broan K7388

40 pages·1.2 MB·Hotte de ventilation·PDF·ENDEITNLJA
Broan K7388
Table des matières 75 sections Model K7388 · READ AND SAVE THESE INSTRUCTIONS · ! INTENDED FOR DOMESTIC COOKING ONLY ! · WARNING · … AfficherMasquer
Page 1 of the Broan K7388 user manual — ENGLISH.....................................3 FRANÇAIS................................14 ESPAÑOL..................................25
Page 1 · cliquer pour agrandir
Page 1
Broan K7388 — Model K7388 diagram (page 1)
Fig. 1 · Model K7388
Broan K7388 — Model K7388 diagram (page 1)
Fig. 2 · Model K7388

Model K7388

ENGLISH 3 FRANÇAIS 14 ESPAÑOL 25

BEST BY BROAN P.O. Box 140, Hartford, WI 53027

Page 2 of the Broan K7388 user manual — Model K7388
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Broan K7388 user manual — Model K7388
Page 3 of the Broan K7388 user manual — WARNING
Page 3 · cliquer pour agrandir
Page 3

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any separate solid-state speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings. Boilovers cause smoking and

greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes

Suzette, Cherries Jubilee, Peppercorn Beef Flambe’). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or

filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface

element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you already know how to operate

it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

Page 4 of the Broan K7388 user manual — READ AND SAVE THESE INSTRUCTIONS
Page 4 · cliquer pour agrandir
Page 4

! CAUTION 1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive mate- rials and vapors. 5. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. 8. Two installers are recommended because of the large size and weight of this hood. 9. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 10. Please read specification label on product for further information and requirements.

Page 5 of the Broan K7388 user manual — FLUE MOUNTING BRACKET
Page 5 · cliquer pour agrandir
Page 5

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag (B080810604) containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 6 - Mounting Screws (4,8 x 38mm Pan Head) 7 - Mounting Screws (3,9 x 9,5mm Pan Head) 2 - Mounting Screws (3.9 x 6mm Flat Head) 6 - Drywall Anchors 1 - Installation Instructions 1 - Warranty Card

Broan K7388 — DECORATIVE FLUE diagram (page 5)
Fig. 3
Broan K7388 — DECORATIVE FLUE diagram (page 5)
Fig. 4

DECORATIVE FLUE

MOUNTING BRACKET

7 MOUNTING SCREWS (3,9 x 9,5mm Pan Head)

DISCHARGE COLLAR

2 MOUNTING SCREWS (3.9 x 6mm Flat Head)

Broan K7388 — DISCHARGE COLLAR diagram (page 5)
Fig. 5

FLUE MOUNTING BRACKET

6 DRYWALL ANCHORS

6 MOUNTING SCREWS (4,8 x 38mm Pan Head)

Page 6 of the Broan K7388 user manual — DECORATIVE
Page 6 · cliquer pour agrandir
Page 6

INSTALL THE DUCTWORK (DUCTED HOODS ONLY)

ROOF CAP

Broan K7388 — ROOF CAP diagram (page 6)
Fig. 6

metal ductwork.

ROUND DUCT

1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back to- wards hood location. Use duct tape to seal the joints between ductwork sections.

DECORATIVE

WALL

FLUE

CAP

HOOD

ROUND ELBOW

6” ADAPTER

24” TO 30” ABOVE COOKING SURFACE

WIRING

Broan K7388 — DECORATIVE diagram (page 6)
Fig. 7

Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Set the electrical power supply within the space covered by the decorative flues. Position the power socket at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration alongside). Make sure this does not inter- fere with the bracket fastening area or with the decorative flue (where the flue touches the wall). Fit the plug into the power socket.

Page 7 of the Broan K7388 user manual — DUCTED AND NON-DUCTED
Page 7 · cliquer pour agrandir
Page 7

INSTALL MOUNTING BRACKET

FRAMING BEHIND DRYWALL

Broan K7388 — FRAMING BEHIND DRYWALL diagram (page 7)
Fig. 8
1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over

installation location. b) the height of the framing will allow the

36-13/16” to 42-11/16” above cooktop

mounting bracket to be secured to the framing within the dimensions shown.

36-13/16"= bottom of hood 24" above cooktop 42-11/16"= bottom of hood 30" above cooktop

2. After wall surface is finished, secure mounting bracket to framing using dimensions shown.

INSTALL FLUE MOUNTING BRACKET

FLUE MOUNTING

BRACKET

3.9 x 6 mm FLAT HEAD BRACKET SCREWS

DUCTED AND NON-DUCTED

1. Assemble the flue mounting bracket, adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket directly over the range hood location.

10-7/16” (265.6 mm)

3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.
Page 8 of the Broan K7388 user manual — LOWER FLUE
Page 8 · cliquer pour agrandir
Page 8

ELECTRICAL

SYSTEM

PLATE

Broan K7388 — SYSTEM diagram (page 8)
Fig. 9

DUCTED CONFIGURATION 1. Remove the tape on the electrical system plate; place the electrical system plate on the hood (use a protection). Fig. 5

2. Install the discharge collar into the duct connector of the range hood. Fig. 6

PROTECTION

3. Attach an adequate length of 6” round steel ducting to the range hood duct connector. Fig. 6
Broan K7388 — PROTECTION diagram (page 8)
Fig. 10

6” DIAMETER

4. Duct tape all joints to make them secure and air tight.

DUCT

5. Carefully place the lower decorative flue into the recessed area of the range hood top. Fig. 7.

DISCHARGE

COLLAR

DUCT CONNECTOR

6. Carefully slide the upper decorative flue down inside the lower flue. Fig. 7.

On 9” ceilings, air vents on the upper flue will be exposed after installation.

CONCEALED UPPER FLUE

UPPER FLUE VENTS

UPPER FLUE VENTS

EXPOSED

Broan K7388 — CONCEALED UPPER FLUE diagram (page 8)
Fig. 11

UPPER FLUE

Broan K7388 — UPPER FLUE diagram (page 8)
Fig. 12

LOWER FLUE

LOWER FLUE

Page 9 of the Broan K7388 user manual — A
Page 9 · cliquer pour agrandir
Page 9

NON - DUCTED CONFIGURATION

  • Non - Ducted Recirculation Kit, Model NDK7388
  • 5” diameter expandable / flexible aluminum duct.
  • 1/16” diameter twist drill.
1. Remove the tape on the electrical system plate; place the electrical system plate on the hood (use a protection). Fig. 8

ELECTRICAL

SYSTEM

PLATE

2. Discard discharge collar and damper supplied with the hood. Install the 5” to 6” adapter supplied with the Non-Ducted Recirculation Kit. Fig. 9.
3. Measure the distance “A”.
4. Attach aluminum flexible duct to the 5” adapter. Tape all joints with duct tape. Fig. 9.

PROTECTION

5. Assemble the recirculation plenum to the flex-ducting. Fig. 9.
Broan K7388 — PROTECTION diagram (page 9)
Fig. 13

PLENUM

6. Drill three (3) 1/16” diameter equally spaced holes through the duct and duct connector of the recirculation plenum. Fig. 9.

(3) SCREWS

5” ALUMINUM FLEX DUCT

7. Secure duct to the plenum’s connector with (3) sheet metal screws (not included). Tape all joints with duct tape. Fig. 9.

A

5” 6” ADAPTER

BLOWER

COLLAR

Page 10 of the Broan K7388 user manual — THE ELECTRICAL
Page 10 · cliquer pour agrandir
Page 10

PLENUM

Broan K7388 — PLENUM diagram (page 10)
Fig. 14

NON - DUCTED CONFIGURATION, cont’d.

7. Carefully place the lower decorative flue into the recessed area of the range hood top. Fig. 7. 8. Carefully slide the upper decorative flue down inside the lower flue. Note: air vents must be up. Fig. 7. 9. Secure the recirculation plenum to the upper flue with (4) flat head screws. Fig. 10.

4 FLAT HEAD SCREWS

UPPER

FLUE

INSTALL THE HOOD

MOUNTING

SCREWS (4.8x38mm)

MOUNTING

WALL FRAMING

Broan K7388 — MOUNTING diagram (page 10)
Fig. 15

SCREWS (3.9x9.5mm)

Note: at least two people will be required to mount the hood. 1. Raise the hood into its mounting position. 2. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue. 3. Align the rectangular opening on the back of the hood with the wall- mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 11. 4. Level the hood with 2 mounting screws (3.9x9.5mm) and secure with (2) mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 11. 5. Mount the plate of the electrical system attaching it with three mounting screws (3.9x9.5mm). Fig. 12. 6. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 13. 7. Secure the flue with (2) mounting screws. Fig. 13.

MOUNTING

MOUNTING

SCREWS (4.8x38mm)

BRACKET

RECTANGULAR

CUTOUT

PLATE OF

Broan K7388 — BRACKET diagram (page 10)
Fig. 16

THE ELECTRICAL

SYSTEM MOUNTING

SCREWS (3.9x9.5mm)

3.9x9.5mm MOUNTING SCREWS

Broan K7388 — THE ELECTRICAL diagram (page 10)
Fig. 17
Page 11 of the Broan K7388 user manual — CLAMP
Page 11 · cliquer pour agrandir
Page 11

NON-DUCTED RECIRCULATION FILTER INSTALLATION

Broan K7388 — NON-DUCTED RECIRCULATION FILTER INSTALLATION diagram (page 11)
Fig. 18
1. Purchase a non-ducted recirculation filter (B03300488) from your dealer.
2. Install the filter by pressing the 2 tabs on the filter down into the special housing and rotating upward.

NON-DUCTED RECIRCULATION

FILTER

MAINTENANCE

Broan K7388 — NON-DUCTED RECIRCULATION diagram (page 11)
Fig. 19

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filters The grease filters must be cleaned approximately once every 30 hours of operation (when the central segment on the display goes on or starts blinking). Use a warm detergent solution. Grease filters are dishwasher safe. Remove filter by pushing filter towards the back of hood and rotating filter downward.

GREASE FILTERS

Broan K7388 — GREASE FILTERS diagram (page 11)
Fig. 20

Non-ducted Recirculation Filter The non-ducted recirculation filter should be changed whenever the central segment of the display starts blinking (i.e. every 120 hours of operation). To remove the filter press inward on the clamp and rotate the filter downward until the 2 tabs can be removed from the housing.

TABS

NON-DUCTED RECIRCULATION

Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:

CLAMP

FILTER

  • Hot water with soap or detergent is all that is usually needed.
  • Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
  • For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
  • For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleaser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
  • DO NOT allow deposits to remain for long periods of time.
  • DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
  • DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.
Page 12 of the Broan K7388 user manual — TIMER SWITCH
Page 12 · cliquer pour agrandir
Page 12

OPERATION

The hood is operated using the (4) push- buttons located at eye-level, on the front edge of the hood.

LIGHT SWITCH

DISPLAY

RESET SWITCH

The light switch turns the halogen lights on and off. Push the light switch once to turn the lights ON - push a second time to turn the lights ON to a brighter level - push a third time to turn the lights OFF.

TIMER SWITCH

BLOWER

SWITCH

The timer switch turns the blower timer on and off. Push this switch once to turn the timer ON. With the blower timer turned ON, the speed that was selected will blink in the display; if the speed selection is changed the blower timer will remain ON; the blower will shut OFF after 5 minutes.

The display indicates: - indicates the selected motor speed (from 1 to 4); - indicates Timer On when the number blinks; - indicates Filter Alarm when the central segments is on or blinking.

The blower switch turns the blower on and off. Push the switch once to turn the blower ON (turns on to last speed selected). Pushing the switch sequentially selects blower speeds from 1 to 4. To turn OFF the blower, push and hold the blower switch for approximately 2 seconds.

The reset switch resets the grease filter or charcoal filter alarm. The grease filter must be cleaned when the center segment of the display lights up continuously or blinks. When the center segment blinks, the grease filter needs to be cleaned and if applicable the charcoal filter should be replaced (only applicable when hood is installed for non-ducted recirculation). The filter alarm will be seen in the DISPLAY for approximately 30 seconds after the blower is turned off. To reset the hour counter, keep the switch pressed for 2 seconds when the alarm can be seen in the DISPLAY.

HEAT SENTRY™ Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface. 1) If blower is OFF - it turns blower ON to HIGH speed. 2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting. WARNING The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

Controls

Page 13 of the Broan K7388 user manual — ELECTRICAL BOX
Page 13 · cliquer pour agrandir
Page 13

HALOGEN BULBS

This range hood requires two halogen bulbs (Type JC, 12Volt, 20Watt Max, G-4 Base). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

Broan K7388 — HALOGEN BULBS diagram (page 13)
Fig. 21

To change bulbs:

1. Open the cover by prying from the proper slots. - DO NOT ROTATE. CAUTION: BULB MAY BE HOT! 3. Replace with a Type JC, 12Volt, 20Watt Max, G-4 Base bulb. Do not touch replacement bulb with bare hands! If the bulb is touched with the bare hand, it should be cleaned with a lint-free cloth moistened with methylated spirit.

FUSE REPLACEMENT

Broan K7388 — FUSE REPLACEMENT diagram (page 13)
Fig. 22

FUSE

SWITCH OFF THE ELECTRICITY SUPPLY.

Remove the decorative flue.

Open the electrical box.

Replace with the same type of fuse (5x20mm, 4A, 125V).

ELECTRICAL BOX

WARRANTY

BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUEN- TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. BEST BY BROAN, P.O. Box 140 Hartford, Wisconsin 53027

Poser une question sur : Broan K7388

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan K7388

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan K7388 manuel PDF

40 pages·1.2 MB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…