TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. Use only metal ductwork. 9. Do not use this unit with any other solid-state speed control device. 10. Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. 11. GROUNDING INSTRUCTION: The appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. The appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN – You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA
1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. off power unit. 4. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will cool down. If the motor continues to shut off and restart, have the hood serviced. 5. The bottom of the hood MUST NOT BE LESS than 24” and recommended at a maximum of 36” above cooktop for best capture of cooking impurities. 6. Two installers are recommended because of the size of this hood. 7. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 8. Be careful when installing the decorative flue and hood, they may have sharp edges. 9. This hood is not intended to be used as a shelf. 10. Please read specification label on product for further information and requirements.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambéing
food (i.e. Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fans frequently. Grease should not be allowed to
Installer: Leave this manual
accumulate on fan or filters. d) Use proper pan size. Always use cookware appropriate for the size
of the surface element.
instructions on pages 7 & 8.

PREPARE THE HOOD
Unpack hood and check contents. You should receive:
HOOD MOUNTING
BRACKET
15 7/8” TO CENTER OF UPPER BRACKET HOLES
2 MOUNTING SCREWS (4mm x 12mm Cross Recessed Pan Head)
BRACKET
DECORATIVE
The minimum hood distance above cooktop MUST NOT BE LESS than 24”.
A maximum of 36” above cooktop is recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion; providing that the ceiling height permits.
4 MOUNTING SCREWS (.188” x .250” Cross Recessed
6 MOUNTING SCREWS (4mm x 38mm Cross Recessed
1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards the hood location. Use duct tape to seal the joints between ductwork sections.
BULB SUCTION CUP TOOL
HOOD ASSEMBLY
3½” · Flat Head) · Pan Head)



This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct. Make sure the outlet is no further than 12” from the top of the hood chassis and that the outlet does not interfere with a mounting bracket fastening area or where the decorative flue touches the wall.
Desired Hood Distance (Above 36" High Cooktop)

* Not recommended for non-ducted configuration ** Non-duct recirculation louvers will be exposed in ducted configuration






DUCT LENGTH
NON-DUCT KIT MODEL RKE56 CONTENTS
DECORATIVE
FLUE
2 MOUNTING SCREWS (4mm x 38mm Cross Recessed
ASSEMBLY 4 MOUNTING SCREWS (.188” x .375” Cross Recessed Flat Head)
FLEXIBLE DUCT
NON-DUCTED RECIRCULATION FILTERS
bracket slots
Pan Head) · Ceiling


Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.
6” ROUND FLEXIBLE METAL DUCT
DUCT LENGTH
Operate the hood as follows:
OFF FAN
OFF LIGHT
DECORATIVE

FAN SPEED LED INDICATORS
OFF
Turns the fan OFF
FAN (1-Pushbutton Switch, 3-Fan Speeds) Turns the fan ON to the last selected speed, and activates a blue LED indicating the fan speed setting. Pressing the FAN button a second time will index the fan speed and LED indicator to the next highest setting. Pressing the FAN button when the fan is at the highest speed setting will index the fan and LED indicator to the lowest setting.
DELAY-OFF (10 Minute Delay-OFF)
Activates the 10 minute delay off feature when the fan is ON (any speed). When activated, the blue LED indicator above the selected speed setting will blink. The hood fan will automatically turn OFF after 10 minutes has elapsed. The DELAY-OFF button can be pressed at any time during the 10 minute countdown to turn off the feature.

LIGHT (1-Pushbutton Switch, 3-Light Intensities)
Turns the lights ON to the lowest intensity. Pressing the LIGHT button a second time will index the light intensity to the next highest level. Pressing the LIGHT button when the lights are at the highest intensity will turn the lights off.
After 30 hours of fan operation, the three blue LED indicators will blink simultaneously, indicating that it is time to clean the grease filters. To reset the filter clean timer, press and hold the OFF button for 3 seconds. The blinking LED indicators will turn off.
This range hood is equipped with a standard Heat Sentry system that monitors excessive temperature and automatically turns the fan speed on HIGH.
The Range Hood Control Board contains a Main Fuse to protect the controls from power surges. New fuses can be purchased at a local electronic supply store. Use 5A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-type fuses.

To replace a fuse (by qualified person(s): 1. Disconnect power at service entrance. 2. Remove decorative flues. 3. Remove control cover. 4. Remove and inspect fuse.

The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately.
20 GAUGE BELL WIRE FOR LOW VOLTAGE CONNECTION ON TOP OF HOOD
Use (2) Halogen Bulbs (included with hood) - 120 V, 35 W, shielded halogen bulbs - MR16 with GU10 base.
Make the connection to the Make-Up Air Damper with low voltage wiring, as shown. See Make-Up Air Damper instructions for additional information.
NOTE Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated. The position of the bulb socket (depth) is adjustable and may require adjustment when: a) certain brands of bulbs are difficult to install. b) the bulb protrudes too far below the light panel.
The hood is compatible with Broan Radio Frequency (RF) Remote Control Model BCR1 (optional). Purchase separately.

To link the BCR1 remote control with the hood, press and hold the LIGH T button for 3-seconds.
The blue LED indicators will turn on and off in succession to indicate the hood is in RF linking mode. When in the linking mode, press any key on the RF remote. An audible beep will be heard at the hood, and the hood LED’s will stop blinking if a successful link is accomplished. If the remote control did not successfully link with the hood, the linking mode will be deactivated after 12 seconds, and the LED’s will stop the sequential blinking. Refer to the BCR1 instructions for additional information.
For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces.
To change the depth of bulb sockets: - Remove 2 screws on light panel – set screws aside - Remove Light Panel. - Loosen 2 Screws holding Lamp Socket Bracket to Light Panel. - Adjust socket/bracket to desired depth. - Re-tighten screws securely. - Re-attach light panel with 2 screws that were previously set aside.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty.
Clean the non-duct recirculating filter surfaces frequently with a damp cloth and a mild detergent. DO NOT immerse filters in water or put in dishwasher. Change the non-duct recirculating filters every 6 months. For replacement non-duct recirculating filters - purchase S99010365 or Model FILTERE56.
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the blower assembly with an exact service replacement.

5 S99527446 User Interface Assembly 1
6 S99527447 User Interface Cable 1
7 S99527449 Control Board 1
8 S99527450 Control Enclosure 1
9 S99527451 Light Panel 1
10 S99010367 Aluminum Grease Filter 1
11 S99527457 Non-Duct Filter Tray 1
12 S99010365 Non-Duct Recirculation Filters (pair) 1
13 S99527455 Curved Glass Plate (EW5630SS) 1
S99527456 Curved Glass Plate (EW5636SS) 1
14 S99527461 Damper Assembly 1
15 S99527462 6” Dia. Expandable Flexible Aluminum Duct 1
16 S99527463 Non-Duct Plenum Assembly 1
17 S99527466 Upper Flue Mounting Bracket 1
18 S99526798 35W MR16 GU10 Halogen Lamp 2
19 S99527468 Capacitor 1
* S99527470 Heat Sensor 1
* S99527471 Fuse 1
* S99527472 Parts Bag 1
* S99527481 User Interface Button, 4-pack 4
Replacement parts can be ordered on our website:
BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCES- SORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NU- TONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119
* Not shown
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.