FR
Broan logo
Notice d'utilisation officielle

Broan APE1

16 pages·2.2 MB·Hotte de ventilation·PDF·ENDEITNLJA
Broan APE1
Table des matières 41 sections CAUTION · Page 2 CLEANING & MAINTENANCE · PREPARE HOOD LOCATION · ROOF CAP · … AfficherMasquer
Page 1 of the Broan APE1 user manual — CAUTION
Page 1 · cliquer pour agrandir
Page 1
Broan APE1 — CAUTION diagram (page 1)
Fig. 1

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel. Lock or tag service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring (including switch loca- tion) must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Provide sufficient air for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the combustion equipment standards such as those published by the National Fire Pro- tection Association (NFPA), the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and local codes. 5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. Use only metal ductwork. 9. As an alternative, this product may be installed with the UL- approved cord kit designated for the product, following in- structions packed with the cord kit. 10. This unit must be grounded.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN — You may be burned or spread the fire. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you

already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. For best capture of cooking impurities, range hood should be mounted so that the bottom of the hood is 18”-24” above the cooking surface. 4. Read specification label on product for information and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pep- percorn Beef Flambe). 3. Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

Broan APE1 — CAUTION diagram (page 1)
Fig. 2

Purchase a non-ducted filter kit from your local distributor or retailer. Follow instructions included with the non-ducted kit.

Installer: Leave this manual with the homeowner. Homeowner: Cleaning, Maintenance and Operating instructions on page 2.

Page 2 of the Broan APE1 user manual — ELECTRICAL ACCESS HOLE
Page 2 · cliquer pour agrandir
Page 2

Page 2 CLEANING & MAINTENANCE

PREPARE HOOD LOCATION

For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces. Clean all- metal filters in the dishwasher.

ROOF CAP

3¼" X 10" (For vertical

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.

SOFFIT

Use 120 V, 42 W fluorescent lamp GX24Q-4. For night light, use 4 W, C-7 bulbs. (Bulbs included with hood.)

HOUSE WIRING (Top or Back of hood)

CABINET

The grease filters, bottom panel, and blower wheel should be cleaned frequently. Use a warm detergent solution. The grease filters and blower wheel are dishwasher safe.

WALL CAP

HOOD HOOD

3¼" X 10" DUCT (For horizontal discharge

18" - 24" ABOVE COOKING SURFACE

tally. For vertical or horizontal discharge, run ductwork be- tween the hood location and a roof cap or wall cap. For best results, use a minimum number of transitions and elbows. OPERATION

1 Determine whether hood will discharge vertically or horizon-

Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.

2 Use the proper diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole.

HEAT SENTRY™

The hood is equipped with a Heat Sentry™ thermostat. This safety device will turn on or speed up the blower if it senses excess heat above the cooking surface. If the blower is not on, or if it is running at low speed, the Heat Sentry™ will override the normal blower control and run the blower on the high speed. When the temperature level drops to normal levels, the blower will return to its original setting.

3¼” X 10” VERTICAL DUCTING

HOOD MOUNTING SCREWS (4)

1615/16" (36" hood) 1615/16" (36" hood) 1315/16" (30" hood) 1315/16" (30" hood)

CABINET FRONT

11/2" 71/2"

CABINET BOTTOM

67/8" 97/8"

Operate the hood as follows:

105/8"

VERTICAL DUCT

ACCESS HOLE

ELECTRICAL ACCESS HOLE (in cabinet bottom) WOOD SHIMS (recessed-bottom

CENTER

LINE

FAN ON OFF

LIGHT FAN

3¼” X 10” VERTICAL DUCTING

FAN The 2-position switch (in center) turns blower ON and OFF. The 5-position switch (at left) controls blower speed.

CABINET FRONT

Blower is OFF (secondary blower OFF). Blower is ON at highest speed. As dots get smaller - blower speed decreases.

37/8"

HORIZONTAL DUCT

ACCESS HOLE

CABINET BOTTOM

LIGHT This 3-position switch (at right) turns lights ON and OFF and controls their intensity.

71/2"

1615/16" (36" hood) 1615/16" (36" hood) 1315/16" (30" hood) 1315/16" (30" hood)

HOOD MOUNTING SCREWS (4)

Lights are OFF. Night Light is ON. Fluorescent Light is ON.

ELECTRICAL ACCESS HOLE

CENTER

LINE

Show 10 more labels / short text on this page
discharge) · 6¼" 6¼" · 9" · cabinets only) · WOOD SHIMS (recessed-bottom · cabinets only) · 3/4" · 1/8" · 6¼" 6¼" · (in wall)
Page 3 of the Broan APE1 user manual — INSTALL THE HOOD
Page 3 · cliquer pour agrandir
Page 3

Page 3 PREPARE THE HOOD

Broan APE1 — Page 3 PREPARE THE HOOD diagram (page 3)
Fig. 3 · Page 3 PREPARE THE HOOD
Broan APE1 — Page 3 PREPARE THE HOOD diagram (page 3)
Fig. 4 · Page 3 PREPARE THE HOOD

5 Remove Vertical Duct Knockout or Horizontal Duct Knockout and attach Damper / Duct Connector with two (2) screws (supplied).

3 Remove the Aluminum Filters, Bottom Cover, and Wiring Cover from the hood.

INSTALL THE HOOD

Broan APE1 — INSTALL THE HOOD diagram (page 3)
Fig. 5
Broan APE1 — INSTALL THE HOOD diagram (page 3)
Fig. 6

6 Run House Power Cable between service panel and hood location. Attach power cable to hood using appropri- ate connector.

4 Blower is shipped in Vertical Discharge Position.

Remove Knurled Nuts from Blower Mounting Rods. Disengage mounting rods from blower and rotate blower to horizontal discharge position. Re-engage mounting rods and tighten blower in place with knurled nuts.

7 Hold the hood in position under the cabinet. Make sure the damper / duct connector enters the Ductwork and that the damper opens and closes freely.

8 Tighten the four (4) Mounting Screws completely to se- cure the hood to the cabinet.

Page 4 of the Broan APE1 user manual — LIGHT
Page 4 · cliquer pour agrandir
Page 4

Page 4 CONNECT THE WIRING

LAMP

GREEN GROUND

SCREW

LAMP BASE

HOUSE POWER

CABLE

HE0059

9 Connect House Power Cable to range hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or BARE WIRE to GREEN Ground Screw.

2 Grasp Lamp at Lamp Base, tilt lamp down and pull out to remove.

COMPLETE INSTALLATION

10 Re-install the wiring cover, bottom cover, and filters that were removed in Step 3.

LAMP REPLACEMENT

NIGHT

FLUORESCENT

LIGHT

LAMP

3 Replace lamps. Use a 42 W Fluorescent Lamp, GX24Q-4 and tilt lamp up into position. For Night Light, use a 4 W, C-7 bulb.

LIGHT

LENS

TAB

SLOT

1 Pull the Tab on the Light Lens forward to remove the lens.

4 Place front edge of light lens into Slot. Push lens up and snap it into place.

Page 5 of the Broan APE1 user manual — Page 5 SERVICE PARTS
Page 5 · cliquer pour agrandir
Page 5

Page 5 SERVICE PARTS

KEY NO.PART NO.DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 3497018487 97007631 97017429 97007656 97017428 98006546 99400084 99010348 99420464 99150617 99170245 99260476 97007313 99100491 98005212 99080597 99020142 99020143 99400055 99500323 98010342 99260491 99260470 600348 97016970 99260485 99111515 99271358 99770154 99770153 97018489 99400052 99150417 99271426Feature Panel Weldment - Silver Bottom Cover - Silver Damper Assembly Wire Cover Assembly Thermostat Bracket Assembly Light Socket Cover Bushing Split Heyco #2873 Filter, Aluminum (Qty. 2) Blower Mounting Rod 8-18 x .375 Truss Head Sheet Metal Screw* 8-18 x .375 Hex Head Phillips Sheet Metal Screw* Blower Mounting Rod Nut Blower Scroll Housing Motor Isolation Bushing Motor Retaining Ring Motor Blower Wheel, Clockwise Blower Wheel, Counterclockwise Heyco Snap Bushing PVC Foam Ring, Inlet Hex Nut 3/8-32 Hex Nut 15/32-32 Knob - Black Switch – Black Nut Sheet Metal U-Type Light Lens Lamp, 42W Fluorescent Ballast Assembly Wire Harness, Hood Reflector Assembly Bushing Strain Relief* Screw, 8-18 x .25 SR SLT HWH AB Lamp, 4W, C-7

* Standard Hardware – may be purchased locally

Poser une question sur : Broan APE1

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan APE1

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan APE1 manuel PDF

16 pages·2.2 MB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…