FR
Broan logo
Notice d'utilisation officielle

Broan AP1

16 pages·2.5 MB·Hotte de ventilation·PDF·ENDEITNLJA
Broan AP1
Table des matières 23 sections CAUTION · Page 2 CLEANING & MAINTENANCE · FAN · LIGHT · … AfficherMasquer
Page 1 of the Broan AP1 user manual — CAUTION
Page 1 · cliquer pour agrandir
Page 1
Broan AP1 — CAUTION diagram (page 1)
Fig. 1

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel. Lock or tag service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring (including switch loca- tion) must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Provide sufficient air for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the combustion equipment standards such as those published by the National Fire Pro- tection Association (NFPA), the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and local codes. 5. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. Use only metal ductwork. 9. As an alternative, this product may be installed with the UL- approved cord kit designated for the product, following in- structions packed with the cord kit. 10. This unit must be grounded.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN — You may be burned or spread the fire. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you

already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. For best capture of cooking impurities, range hood should be mounted so that the bottom of the hood is 18”-24” above the cooking surface. 4. Read specification label on product for information and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ig- nite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pep- percorn Beef Flambe). 3. Clean ventilating fans frequently. Grease should not be al- lowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

Broan AP1 — CAUTION diagram (page 1)
Fig. 2

Purchase a non-ducted filter kit from your local distributor or retailer. (Available for AP1 & RP2 Series hoods only.) Follow instructions included with the non-ducted kit.

Installer: Leave this manual with the homeowner. Homeowner: Cleaning, Maintenance and Operating instructions on page 2.

Page 2 of the Broan AP1 user manual — 18" - 24" ABOVE COOKING SURFACE
Page 2 · cliquer pour agrandir
Page 2

Page 2 CLEANING & MAINTENANCE

AP SERIES HOOD Operate the hood as follows:

For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces. Clean all- metal filters in the dishwasher.

Broan AP1 — Page 2 CLEANING & MAINTENANCE diagram (page 2)
Fig. 3 · Page 2 CLEANING & MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.

Use 120 V, 50 W, shielded halogen bulbs - MR16 or PAR16 with GU10 base. Purchase bulbs separately.

FAN

The grease filters, bottom panel, and blower wheel should be cleaned frequently. Use a warm detergent solution. The grease filters and blower wheel are dishwasher safe.

The 2-position switch (in center) turns blower ON and OFF. The 5-position switch (at left) controls blower speed.

Blower is OFF (secondary blower OFF). Blower is ON at highest speed. As dots get smaller - blower speed decreases.

LIGHT

OPERATION

This 3-position switch (at right) turns lights ON and OFF and controls their intensity.

Always turn the hood ON before cooking in order to establish an air flow in the kitchen. After turning off the range, let the hood run for a few minutes to clear the air.

Lights are OFF.

Lights are ON to low intensity.

Lights are ON to highest intensity.

HEAT SENTRY™

The hood is equipped with a Heat Sentry™ thermostat. This safety device will turn on or speed up the blower if it senses excess heat above the cooking surface.

PREPARE HOOD LOCATION

If the blower is not on, or if it is running at low speed, the Heat Senttry™ will override the normal blower control and trun the blower on the high speed. When the temperature level drops to normal levels, the blower will return to its original setting.

ROOF CAP

3¼" X 10" (For vertical

RP SERIES HOOD Operate the hood as follows:

SOFFIT

HOUSE WIRING (Top or Back of hood)

CABINET

BLOWER SWITCH

WALL CAP

This 3-position switch turns blower ON and OFF and controls blower speed. Set switch to (1) position to turn blower ON to low speed. Set switch to (2) position to turn blower ON to high speed. Set switch to (0) position to turn blower OFF.

HOOD HOOD

3¼" X 10" DUCT (For horizontal discharge

18" - 24" ABOVE COOKING SURFACE

LIGHT SWITCH

1 Determine whether hood will discharge vertically or hori-

This 3-position switch turns lights ON and OFF and controls their intensity. Set switch to (1) position to turn lights ON to low intensity. Set switch to (2) position to turn lights ON to high intensity. Set switch to (0) position to turn lights OFF.

zontally. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitions and elbows.

discharge)

Page 3 of the Broan AP1 user manual — Page 3
Page 3 · cliquer pour agrandir
Page 3

Page 3

PREPARE THE HOOD

2 Use the proper diagram below, for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole.

Broan AP1 — Page 3 diagram (page 3)
Fig. 4 · Page 3
Broan AP1 — Page 3 diagram (page 3)
Fig. 5 · Page 3

1615/16" (36" hood) 1615/16" (36" hood) 1315/16" (30" hood) 1315/16" (30" hood)

ELECTRICAL ACCESS HOLE (in cabinet bottom) WOOD SHIMS (recessed-bottom

Broan AP1 — Page 3 diagram (page 3)
Fig. 6 · Page 3

3 Remove the Aluminum Filters, Bottom Cover, and Wiring Cover from the hood.

Broan AP1 — Page 3 diagram (page 3)
Fig. 7 · Page 3

1615/16" (36" hood) 1615/16" (36" hood) 1315/16" (30" hood) 1315/16" (30" hood)

4 Blower is shipped in Vertical Discharge Position.

Remove Knurled Nuts from Blower Mounting Rods. Disengage mounting rods from blower and rotate blower to horizontal discharge position. Re-engage mounting rods and tighten blower in place with knurled nuts.

Page 4 of the Broan AP1 user manual — COMPLETE INSTALLATION
Page 4 · cliquer pour agrandir
Page 4

Page 4

CONNECT THE WIRING

Broan AP1 — Page 4 diagram (page 4)
Fig. 8 · Page 4
Broan AP1 — Page 4 diagram (page 4)
Fig. 9 · Page 4

9 Connect House Power Cable to range hood wiring - BLACK to BLACK, WHITE to WHITE, and GREEN or BARE WIRE to GREEN Ground Screw.

5 Remove Vertical Duct Knockout or Horizontal Duct Knockout and attach Damper / Duct Connector with two (2) screws (supplied).

COMPLETE INSTALLATION

INSTALL THE HOOD

10 Re-install the wiring cover, bottom cover, and filters that were removed in Step 3.

Broan AP1 — COMPLETE INSTALLATION diagram (page 4)
Fig. 10

11 Install Halogen Bulbs. Use 120 V, 50 W, shielded halo- gen bulbs - MR16 or PAR16 with GU10 base. Purchase bulbs separately.

6 Run House Power Cable between service panel and hood location. Attach power cable to hood using appropri- ate connector.

7 Hold the hood in position under the cabinet. Make sure the damper / duct connector enters the Ductwork and that the damper opens and closes freely.

8 Tighten the four (4) Mounting Screws completely to se- cure the hood to the cabinet.

Page 5 of the Broan AP1 user manual — WARRANTY
Page 5 · cliquer pour agrandir
Page 5

Page 5 SERVICE PARTS

KEY NO.PART NO.DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 **97017222 97017223 97017224 97017324 97017325 97017326 97009517 97007895 97007631 97017429 97007656 97017428 98006546 99400084 99271346 97017312 97017264 99111379 97017455 97017456 99420464 99150617 99170245 99260476 97007313 99100491 98005212 99080597 99020142 99020143 99400055 99500323 98010342 99260491 99260470 600348 600349 97016970 97016971 99260485 99400052 99770113 99770115 99030132 97016439Feature Panel Weldment - RP-Black Feature Panel Weldment - RP-White Feature Panel Weldment - RP-Silver Feature Panel Weldment - AP-Black Feature Panel Weldment - AP-White Feature Panel Weldment - AP-Silver Bottom Cover - Black Bottom Cover - White Bottom Cover - Silver Damper Assembly Wire Cover Assembly Thermostat Bracket Assembly Light Socket Cover Bushing Split Heyco #2873 Socket/Trim Ring Assembly Control - RP, Black Control - RP, White Spacer .50 x .375 Nylon Filter, Aluminum (Qty. 2) Filter, Aluminum with antimicrobial protection (Qty. 2) Blower Mounting Rod 8-18 x .375 Truss Head Sheet Metal Screw * 8-18x.375 Hex Head Phillips Sheet Metal Screw * Blower Mounting Rod Nut Blower Scroll Housing Motor Isolation Bushing Motor Retaining Ring Motor Blower Wheel, Clockwise Blower Wheel, Counterclockwise Heyco Snap Bushing PVC Foam Ring, Inlet Hex Nut 3/8-32 Hex Nut 15/32-32 Knob - Black Knob - White Switch - Black Switch - White Nut Sheet Metal U-Type Bushing Strain Relief (Not Shown) Wire Harness - NSP, RP Wire Harness - AP Rotary Fan Control Rotary Light Control

WARRANTY

BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119

* Standard hardware - may be purchased locally. ** Not illustrated Order replacement parts by PART NO. - not by KEY NO.

Replacement parts can now be ordered on our website. Please visit us at www.broan.com

28 29 30

Poser une question sur : Broan AP1

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan AP1

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan AP1 manuel PDF

16 pages·2.5 MB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…