Switch 4900 (3C17700) Switch 4900 SX (3C17702) Switch 4924 (3C17701) Switch 4950 (3C17706)

Part No. DUA1770-0AAA04 Published August 2002

3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8145
Copyright © 2002, 3Com Technologies. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Technologies.
3Com Technologies reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Technologies to provide notification of such revision or change.
3Com Technologies provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com, the 3Com logo, and SuperStack are registered trademarks of 3Com Corporation.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
Netscape Navigator is a registered trademark of Netscape Communications.
JavaScript is a trademark of Sun Microsystems.
All other company and product names may be trademarks of the respective companies with which they are associated.
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and the inks are vegetable-based with a low heavy-metal content.
Regulated Materials Statement

Conventions 8 Related Documentation 9 Accessing Online Documentation 9 Product Registration 10 Documentation Comments 10
1 INTRODUCING THE SUPERSTACK 3 SWITCH 4900 SERIES
About the Switches 12 Summary of Hardware Features 13 Switch — Front View Detail 14 100/1000BASE-T and 10/100/1000BASE-T Ports 16 1000BASE-SX Ports 16 GBIC Ports 16 LEDs 17 Switch — Rear View Detail 18 Unit Information Label 19 Power Socket 19 Redundant Power System Socket 19 Console Port 20 Expansion Module Slot 20 Default Settings 20
Package Contents 22 Choosing a Suitable Site 22 Rack-mounting 23 Placing Units On Top of Each Other 24 Creating an XRN Distributed Fabric 24 How To Interconnect Units 25

Rules For Interconnecting Units 25 The Power-up Sequence 26 Powering-up the Switch 26 Checking for Correct Operation of LEDs 26 Connecting a Redundant Power System 27 Choosing the Correct 10/100/1000BASE-T Cables 27 Choosing the Correct Fiber Cables 28 Switch 4950 — GBIC Operation 29 Approved GBIC Transceivers 29 Inserting a GBIC Transceiver 29
Setting Up Overview 34 IP Configuration 35 Preparing for Management 36 Manually Configuring IP Information 37 Connecting to a Front Panel Port 37 Connecting to the Console Port 40 Viewing Automatically Configured IP Information 43 Using 3Com Network Supervisor 43 Connecting to the Console Port 44 Methods of Managing a Switch 46 Command Line Interface Management 46 Web Interface Management 47 SNMP Management 47 Setting Up Command Line Interface Management 48 CLI Management via the Console Port 48 CLI Management over the Network 48 Setting Up Web Interface Management 49 Pre-requisites 49 Web Management Over the Network 50 Setting Up SNMP Management 51 Pre-requisites 51 Default Users and Passwords 51 Changing Default Passwords 52

Solving Problems Indicated by LEDs 54 Solving Hardware Problems 55 Solving Communication Problems 57 Solving Software Upgrade Problems 58
Null Modem Cable 69 PC-AT Serial Cable 69 Modem Cable 70 RJ-45 Pin Assignments 70
D T ECHNICAL S UPPORT
Online Technical Services 75 World Wide Web Site 75 3Com Knowledgebase Web Services 75 3Com FTP Site 76 Support from Your Network Supplier 76 Support from 3Com 77 Email Support 77 Telephone Support 77 Returning Products for Repair 79
R EGULATORY N OTICES



This guide provides all the information you need to install and use the following Switches in their default state:
This guide is intended for use with all the 4900 Series Switches listed above. For illustrative purposes all pictures and example screens show the 4900 model, however, all procedures apply to all the other Switches listed unless otherwise stated.
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
If the information in the release notes that are shipped with your product differ from the information in this guide, follow the instructions in the release notes.
Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the 3Com World Wide Web site:

Conventions Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons
Table 2 Text Conventions

In addition to this guide, each Switch documentation set includes the following:
This guide contains:
These notes provide information about the current software release, including new features, modifications, and known problems.
This guide contains information on the features supported by your Switch and how they can be used to optimize your network. It is supplied in PDF format on the CD-ROM that accompanies the Switch.
This guide provides detailed information about the web interface and command line interface that enable you to manage the Switch. It is supplied in HTML format on the CD-ROM that accompanies the Switch.
There are other publications you may find useful:
The CD-ROM supplied with your Switch contains the following online documentation:
Related Documentation 9

To access the online documentation from the CD-ROM:
1 Insert the CD-ROM into the relevant CD-ROM drive. If your PC has auto-run enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
If the online documentation is to be accessed from a local drive or server, you will need to access the CD-ROM contents via the root directory and copy the files from the CD-ROM to a suitable directory.
3Com recommends that you copy the Docs/referenceguide directory as a whole to maintain the structure of the files.
You can register your SuperStack 3 Switch on the 3Com Web site to receive up-to-date information on your product:
http://support.3com.com/registration/frontpg.pl
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments about this document to 3Com at:
Please include the following information when commenting:
Example:
SuperStack 3 Switch 4900 Series Getting Started Guide
Part Number DUA1770-0AAA0x · Page 21

1 INTRODUCING THE SUPERSTACK 3 SWITCH 4900 SERIES
This chapter contains introductory information about the Switch 4900, 4900 SX, 4924 and 4950 and how they can be used in your network. It covers summary information about the hardware.
The information for all the Switches in the Switch 4900 Series is the same unless otherwise stated.

About the Switches ■ The Switch 4900 connects your existing 100 Mbps devices and high-performance workgroups with a 1000 Mbps copper backbone or server connection.
You can also interconnect any combination of two Switches from the SuperStack® 4900 Series or 3Com Switch 4050/4060 range to create an XRN Distributed Fabric. This allows you to create a highly resilient core around which you can build your network. For more information about interconnecting Switches, see “Creating an XRN Distributed Fabric” on page 24. For more information about 3Com XRN Technology and how to use it in your network, refer to the Implementation Guide on the CD-ROM that accompanies the Switch.
For information about using the software features of the Switch, refer to the “SuperStack 3 Switch Management Interface Reference Guide” on the CD-ROM that accompanies the Switch.

About the Switches 13
Table 3 summarizes the hardware features that are supported by the Switches.
Table 3 Hardware features
Feature Switch 4900 Series
Fast Ethernet and Gigabit Ethernet Ports
Addresses ■ Up to 12,000 supported
Duplex Modes ■ Half duplex only supported on 10BASE-T/100BASE-TX/1000BASE-T ports in 10/100 Mbps mode
Flow Control Supported on all ports
Supported (IEEE Std 802.1D, 1998 Edition)
Four traffic queues per port
Support for wire-speed IP routing
RPS Support Connects to SuperStack 3 Advanced Redundant Power System (ARPS) (3C16071B)
XRN Support eXpandable Resilient Networking (XRN) support. Allows interconnection of two units to create a Distributed Fabric.
Mounting 19-inch rack or stand-alone mounting

Figure 1 Switch 4900 — front view

Figure 2 Switch 4900 SX — front view


Switch — Front View Detail 15
Figure 3 Switch 4924 — front view

Figure 4 Switch 4950 — front view

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.

The 100BASE-TX/1000BASE-T and 10BASE-T/100BASE-TX/1000BASE-T ports have RJ-45 connectors and are configured as Auto MDIX (cross-over).
The default state for these ports is auto-negotiation enabled, where the speed, duplex and flow control modes of a link are automatically detected to provide the highest available bandwidth with the link partner.
Alternatively, auto-negotiation can be disabled. These ports can be manually configured to 10 Mbps half duplex (if supported), 100 Mbps half duplex, 10 Mbps full duplex (if supported), or 100 Mbps full duplex. It is not possible to manually configure a 1000BASE-T link as auto-negotiation is mandatory in the 1000BASE-T standard.
The maximum segment length is 100 m (328 ft) over Category 5 twisted pair cable.
1000BASE-T operation only supports full-duplex mode.
10BASE-T (10 Mbps) is only supported on Switch 4924 and 4950.
1000BASE-SX Ports The default state for these ports is auto-negotiation enabled, where the speed, duplex and flow control modes are negotiated. As the speed and duplex modes are fixed by the media type, only the flow control is negotiated with the link partner. Alternatively, auto-negotiation can be disabled and the flow control setting can be manually configured.
1000BASE-SX ports do not support auto-negotiation of speed and only support full duplex mode.
GBIC Ports GBIC ports support fiber Gigabit Ethernet short-wave (SX), long-wave (LX) and long-haul (LH70) GBIC transceivers in any combination. This offers you the flexibility of using GBIC transceivers to provide connectivity between the Switch and remote 1000 Mbps workgroups or to create a high capacity aggregated link backbone connection.
The default state for these ports is auto-negotiation enabled, where the speed, duplex and flow control modes are negotiated. As the speed and duplex modes are fixed by the media type, only the flow control is negotiated with the link partner. Alternatively, auto-negotiation can be disabled and the flow control setting can be manually configured.

Switch — Front View Detail 17
LEDs Table 4 lists LEDs visible on the front of the Switch, and how to read their status according to color. For information on using the LEDs for problem solving, see “Checking for Correct Operation of LEDs” on page 26.
Table 4 LED behavior
Packet Yellow Packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
Status Green A high speed (1000 Mbps) link is present, and the port is enabled.
Green flashing A high speed (1000 Mbps) link is present, but the port is disabled.
Yellow A low speed (100 Mbps on 4900, 10/100 Mbps on 4924/4950) link is present, and the port is enabled. (Not applicable on 4900 SX.)
Yellow flashing A low speed (100 Mbps on 4900, 10/100 Mbps on 4924/4950) link is present, but the port is disabled. (Not applicable on 4900 SX.)
Off No link is present.
Green The Module is installed and supported. The Link Status has been determined for a single port Module.
Yellow The Module is installed and supported. The Module has multi-ports or there is no Link for a single port Module.
Yellow flashing The Module is installed but not supported. Note that the Switch will continue to operate normally.
Off The Module is not installed.
1–4 Green Determines the identity of the Switch when interconnected to another Switch to create an XRN Distributed Fabric and that a link is present.
Off A fault has occurred.
Green The Switch is powered-up and operating normally.
Green flashing The Switch is either downloading software or is initializing (which includes running a Power On Self Test).
Yellow The Switch has failed its Power On Self Test.
Off The Switch is not receiving power.


Off The Switch software does not support Layer 3.
Figure 5 Switch 4900 — rear view

Figure 6 Switch 4900 SX — rear view


Switch — Rear View Detail 19
Figure 7 Switch 4924 — rear view

Figure 8 Switch 4950 — rear view

This label shows the following:
You may need this information for fault reporting purposes.
Power Socket The Switch automatically adjusts its power setting to any supply voltage in the range 90-240 VAC.
To protect against internal power supply failure, you can use this socket to connect a SuperStack 3 Advanced Redundant Power System (RPS) to the Switch. See “Connecting a Redundant Power System” on page 27.

Console Port The console port allows you to connect a terminal and perform remote or local out-of-band management. The console port uses a standard null modem cable and is set to auto-baud (up to a maximum of 19200 baud), 8 data bits, no parity and 1 stop bit.
You can use this slot to install an Expansion Module. Contact your supplier for further information on the range of Expansion Modules supported by your Switch.
Default Settings Table 5 shows the default settings for the Switches. If you initialize one of the Switch units, it is returned to these defaults.
Table 5 Default Setting
Feature Switch 4900 Series
Broadcast Storm Control Enabled
Virtual LANs (VLANs) All ports belong to the untagged Default VLAN (VLAN 1)
Multicast Filtering IGMP filtering enabled
Rapid Spanning Tree Protocol Enabled
Link Aggregation Control Protocol (LACP)
Smart Auto-sensing Switch 4900, 4924, and 4950: Enabled Switch 4900 SX: Not applicable
IP Address 169.254.100.100*
Subnet Mask 255.255.0.0
* This default IP address is used if the unit is operating in standalone mode, and/or no other Switches on the network have this IP address. If this default IP address is already in use then the Switch detects this and configures itself with an IP address in the range 169.254.1.0 to 169.254.254.255.

This chapter contains the information you need to install and set up the Switch. It covers the following topics:

Package Contents ■ Switch unit
The Switch is suited for use in an internal wiring closet, a network room, or telecommunications room, where it can be mounted in a standard 19-inch equipment rack, or free-standing.
To ensure this product provides optimum performance, high speed fans are used to provide ventilation. These fans have a high audible output.
When deciding where to position the Switch, ensure that:
If the Switch is installed in a 19-inch rack or closed assembly its local air temperature may be greater than room ambient temperature.

Rack-mounting The Switch is 1.5U and will fit in most standard 19-inch racks. However, as each Switch requires a shelf or runner to support its weight, you may need to allow a 2U space within the rack for each Switch.
WARNING: The Switch should only be used in a rack if it is mounted on runners, a shelf, or a tray to support the weight. The rack-mount kits alone are not sufficient to support the weight of the switch. The rack- mount kits must not be used to suspend the Switch from under a table or desk, or attach it to a wall.
To rack-mount your Switch:
1 Place the Switch the right way up on a hard flat surface, with the front facing towards you.
2 Locate a securing bracket over the mounting holes on one side of the Switch, as shown in Figure 9.
3 Insert the three screws and tighten with a suitable screwdriver.
Rack-mounting 23

Figure 9 Fitting a bracket for rack-mounting

You must use the screws supplied with the securing brackets. Damage caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws (not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
If the Switch units are free-standing, up to four units can be placed one on top of the other. If you are mixing a variety of SuperStack® 3 Switch and Hub units, the smaller units must be positioned at the top.
If you are placing Switch units one on top of the other, you must use the self-adhesive rubber pads supplied. Apply the pads to the underside of each Switch, sticking one in the marked area at each corner. Place the Switch units on top of each other, ensuring that the pads of the upper unit line up with the recesses of the lower unit.
Switch 4900 Series units and 3Com Switch 4050/4060 units can be interconnected to create an XRN Distributed Fabric and then treated as a single manageable unit with one IP address. A combination of any two of these units is allowed to be interconnected.

Creating an XRN Distributed Fabric 25
To interconnect any two Switch 4900 Series or Switch 4050/4060 units you will need to order the XRN Interconnect Module Kit (3C17715). The kit consists of two XRN Interconnect Modules and an Interconnect Cable. Both Switches must have an unused expansion slot to allow an Interconnect Module to be fitted.
Figure 10 Interconnecting two Switch 4900 units

XRN Interconnect Module (3C17716) XRN Interconnect Module (3C17716) Console (max) 19200,8,1,N
XRN Interconnect Module (3C17716) XRN Interconnect Module (3C17716) Console (max) 19200,8,1,N
For information on ordering the XRN Interconnect Kits contact your supplier. For illustrations and information on how to install the XRN Interconnect Kits, refer to the user documentation that accompanies these Kits.
This information is also provided in the user documentation that accompanies the XRN Interconnect Kits.

existing unit. If you do not initialize the unit, problems may be caused by conflicting Switch configurations.
For a detailed description of how XRN Technology operates and implementation guidelines, please refer to the Implementation Guide on the CD-ROM that accompanies your Switch or on the 3Com Web site.
The following sections describe how to get your Switch powered-up and ready for operation.
Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST), which takes approximately 10 seconds.
During the Power On Self Test, all ports on the Switch are disabled and the LEDs light in a rapid sequence.
When the POST has completed, check the Power/Self Test LED to make sure that your Switch is operating correctly. Table 6 shows possible colors for the LED.
Table 6 Power/Self Test LED Colors
Green The Switch is powered-up and operating normally.
Yellow The Switch has failed its Power On Self Test (POST) because of an internal problem.
Off The Switch is not receiving power.
Color State

The Power-up Sequence 27
If there is evidence of a problem, see “Solving Problems Indicated by LEDs” on page 54 for a list of suggested solutions.
You can connect a SuperStack 3 Advanced Redundant Power System to the Switch. This unit, which is also known as an RPS, is designed to maintain the power to your Switch if a power supply failure occurs.
For normal redundancy, the unit requires one Type 3 Power Module (part number 3C16075).
For full redundancy, the unit requires two Type 3 Power Modules combined using a Type 3 Y-Cable (part number 3C16077).
If your Switch has 10/100/1000BASE-T ports, these ports are Auto-MDIX, that is they have a cross-over capability. These ports can automatically detect whether to operate in MDI or MDIX mode. Therefore you can make a connection to one of the ports with a straight-through (MDI) or a cross-over cable (MDIX).
The Auto-MDIX feature only operates when auto-negotiation is enabled.
If auto-negotiation is disabled, all the Switch ports are configured as MDIX (cross-over). If you want to make a connection to another MDIX port, you need a cross-over cable. Many ports on workstations and servers are configured as MDI (straight-through). If you want to make a connection to an MDI port, you need to use a standard straight-through cable. See Table 7.
3Com recommends that you use at least Category 5 twisted pair cable — the maximum segment length for this type of cable is 100 m (328 ft).

Table 7 Cables required to connect the Switch to other devices if
Cross-over Cable Straight-through Cable
Switch to Switch (MDIX to MDIX) ✓ ✕
Switch to Hub (MDIX to MDIX) ✓ ✕
Switch to PC (NIC) (MDIX to MDI) ✕ ✓
You can create a grounded port by connecting all wires at one end of a UTP cable to an earth ground point, and the other end to a female RJ-45 connector located, for example, on a Switch rack or patch panel. The RJ-45 connector is now a grounded port.
If your Switch has fiber ports you can choose from the following cable options:
For detailed information on fiber cable specifications, refer to the SuperStack 3 Implementation Guide on the CD-ROM that accompanies your Switch.
If you wish to connect a 1000BASE-SX MT-RJ port to a fiber port with a different type of connector, for example, SC or ST please contact your network supplier for a suitable patch cable.
auto-negotiation is disabled

Switch 4950 — GBIC Operation 29
The following sections describes how to insert a GBIC transceiver into a GBIC port on a Switch 4950.
GBIC transceivers are hot-insertable and hot-swappable. You can remove them from and insert then into any GBIC port without having to power down the Switch.
The following list of approved GBIC transceivers is correct at the time of publication.
To access the latest list of approved GBIC transceivers for the Switch on the 3Com Corporation World Wide Web site, enter this URL into your internet browser:
The URL is case sensitive.
To be recognised as valid, the GBIC transceiver must have the following characteristics:
Use this transceiver to connect the Switch directly to a multimode fiber-optic cable.
Use this transceiver to connect the Switch directly to a single-mode fiber-optic cable or to multimode fiber using a conditioned launch cable.
Use this transceiver to connect the Switch directly to a single-mode fiber-optic cable or to multimode fiber using a conditioned launch cable.

If the GBIC transceiver is faulty, it will not operate within the Switch. See “Solving Hardware Problems” on page 55.
Do not use non-3Com GBICs. If the GBIC transceiver is invalid it will not be recognised by the Switch.
Use the following sequence of steps to activate the GBIC ports.
1 To insert one of the transceivers into a GBIC expansion port on the Switch:
a Orient the transceiver so that the fiber-optic duplex subscriber connecter (SC) is toward you, as shown in Figure 11.
b Gently slide the transceiver into the GBIC port until it clicks into place.
2 If you wish to remove the transceiver, compress the side tabs and gently pull the transceiver out of the port.
Figure 11 Inserting a GBIC Transceiver into a Switch 4950


Switch 4950 — GBIC Operation 31
3 The transceiver connects to the network using a duplex SC connector. Attach a male duplex SC connector on the network cable into the duplex SC connector on the transceiver.
4 Connect the other end of the cable to a device fitted with an appropriate Gigabit Ethernet connection.
5 Check the LEDs on the front of the Switch to ensure that it is operating correctly. Refer to “LEDs” on page 17 for more information.


Your Switch can operate in its default state, that is, you can install it and it will work straight away (plug-and-play). However, to make full use of the features offered by the Switch, and to change and monitor the way it works, you have to access the management software that resides on the Switch. This is known as managing the Switch.
Managing the Switch can help you to improve the efficiency of the Switch and therefore the overall performance of your network.
This chapter explains the initial set up of the Switch and the different methods of accessing the management software to manage a Switch. It covers the following topics:

This section gives an overview of what you need to do to get your Switch set up and ready for management when it is in its default state. The whole setup process is summarised in Figure 12. Detailed procedural steps are contained in the sections that follow. In brief, you need to:
Figure 12 Initial Switch Setup and Management Flow diagram

Plug and Play Setup Initial IP Information Setup Feature Management
Do you want to manually configure the IP information?
configured IP information? How do you want to connect to the Switch?
Connect to a front panel port and use the
How do you want to manage your Switch? See page 46

Setting Up Overview 35
users and changing default passwords, see “Default Users and Passwords” on page 51.
IP Configuration You can use one of the following methods to allocate IP information to your Switch (essential if you wish to manage your Switch across the network).
You can choose to configure the IP information yourself. The Switch remembers the information that you enter until you change it again or set the configuration method to Automatic.
You should use the Manual IP configuration method if:
For most installations, 3Com recommends that you configure the Switch IP information manually. This makes management simpler and more reliable as it is not dependent on a DHCP or BootP server, and eliminates the risk of the IP address changing.
If you wish to manually enter IP information for your Switch, work through the “Manually Configuring IP Information” section on page 37.
By default the Switch tries to configure itself with IP information without requesting user intervention. It tries to obtain an IP address from a DHCP or BootP server on the network.
If neither server is found, the Switch will configure itself with its default IP address 169.254.100.100 if it is operating in a standalone mode, and/or no other Switches on the network have this IP address. If this default IP address is already in use on the network then the Switch detects this and configures itself with an IP address in the range 169.254.1.0 to 169.254.254.255.
This process is known as Auto-IP and is the same mechanism used by Windows 98 and Windows 2000. IP addresses configured by Auto-IP are

temporary as they cannot be routed but are useful for small networks which are not connected to other networks, or for initial configuration.
However, as soon as a DHCP or BootP server is detected, the Switch will configure itself with the IP address allocated by that server.
When using automatic IP configuration it is important that the IP address of the Switch is static, otherwise you will not know what the IP address is and it will be difficult to manage. Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address will be allocated to the Switch. Refer to the documentation that accompanies your DHCP/BootP server.
For a detailed description of how automatic IP configuration operates, please refer to the Implementation Guide on the CD-ROM that accompanies your Switch or on the 3Com Web site.
You should use the automatic IP configuration method if:
If you use the automatic IP configuration method, you need to discover the automatically allocated IP information before you can begin management. Work through the “Viewing Automatically Configured IP Information” section on page 43.
Once your Switch’s initial set up is complete you can set up your chosen management method as described in “Methods of Managing a Switch” on page 46.
For detailed information about the specific web interface operations and command line interface commands and problem solving, refer to the “Management Interface Reference Guide” on the CD-ROM that is supplied with the Switch or on the 3Com Web site.

Manually Configuring IP Information 37
You can manually configure the Switch IP information in the following ways:
To set up your Switch manually you can make a connection to a front panel port. You must do this whilst the Switch is offline, that is, before you connect the Switch to a network.
The procedure described in this section assumes the unit has been powered up in standalone mode and has the default IP address of 169.254.100.100.

1 Connect the workstation to a front panel port using an Ethernet cable as shown in Figure 13.
Figure 13 Connecting a workstation to the Switch via a front panel port

To connect the cable:
a Attach an RJ-45 connector at one end of the Ethernet cable to the Network Interface Card (NIC) in the workstation.
b Connect the RJ-45 connector at the other end of the cable to one of
the front panel ports on the Switch.
Do not interconnect the Switch to any other unconfigured Switch.
You need to change the IP address and subnet mask of the workstation that you have connected to the Switch. Make a note of the existing settings so you can return to them later. Change the workstation to the following settings:
You are now ready to manually set up the Switch with IP information. You can do this using the Web interface or the command line interface (CLI) via telnet.
1 Power-up the Switch. This takes approximately one minute.
2 Open a suitable Web browser and enter 169.254.100.100 in the Location Address field. This is the default IP address that is automatically assigned to an offline unit.

Manually Configuring IP Information 39
If there is no response, wait for one minute then re-enter the default IP address.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt (default user name and password). If you have logged on correctly, a set of Getting Started pages are displayed.
4 The Getting Started pages allow you to enter basic setup information for the Switch. Select Manual and then enter the IP address, subnet mask, and default gateway that you want the Switch to use when it is connected to the network. The final page displays a summary of the information entered.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 46.
1 To start a Telnet session to the unit, click Start in Microsoft Windows 95/98/2000/NT.
a Click Run.
b In the dialogue box that appears type the default IP address of the
c Click OK.
2 Press Enter to open a login prompt.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 14.

Figure 14 Example top-level command line interface menu

4 At the Select menu option prompt you can either:
5 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
If using the gettingStarted command you will then be prompted to enter system information, change passwords, and then given the option to carry out advanced configuration.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 46.
To set up your Switch manually you can alternatively make a connection to the console port (this example describes a local connection to the console port, rather than a remote one via a modem). You can do this whilst the Switch is offline, that is, before you connect the Switch to a network, or whilst the Switch is online, that is, connected to a network.
Pre-requisites
or

Manually Configuring IP Information 41
You can find pin-out diagrams for both cables in Appendix B on page 69.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 15.
Figure 15 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch. b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:

Refer to the documentation that accompanies the terminal emulation software for more information.
You are now ready to manually set up the Switch with IP information using the command line interface.
1 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
2 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 16.
Figure 16 Example top-level command line interface menu
3 At the Select menu option prompt you can either:
or

Viewing Automatically Configured IP Information 43
4 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
If using the gettingStarted command you will then be prompted to enter system information, change passwords, and then given the option to carry out advanced configuration.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 46.
If you do not intend to use the command line interface via the console port to manage the Switch, you can logout, disconnect the serial cable and close the terminal emulator software.
If you allow the Switch to automatically configure its own IP information you need to discover and view the IP information before you can begin to manage the Switch. You can discover the IP information in two ways:
You can use the 3Com Network Supervisor application provided on the CD-ROM that accompanies your Switch to discover the automatically allocated IP information.
1 Connect your Switch to the network.
2 Power-up the Switch and wait for two minutes.
3 Launch 3Com Network Supervisor and run the Auto-discovery wizard.
3Com Network Supervisor will auto-discover the new Switch and display the IP information that has been automatically allocated to the Switch.
Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address the Switch will be given. Refer to the documentation that accompanies your DHCP or BootP server.

If your network does not have a DHCP or BootP server, the workstation running 3Com Network Supervisor must be on the same subnet as the Switch, because Auto-IP addresses are non-routable.
Alternatively, you can view the automatically configured IP information via the command line interface (CLI) through a connection to the console port. (This example describes a local connection to the console port, rather than a remote one via a modem.)
Pre-requisites
You can find pin-out diagrams for both cables in Appendix B on page 69.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 17.
Figure 17 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch.

Viewing Automatically Configured IP Information 45
b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
You are now ready to view the automatically allocated IP information using the command line interface.
1 Connect your Switch to the network using an Ethernet cable. As soon as a network connection is made the Switch begins the automatic IP configuration process.
The automatic IP configuration process usually completes within one minute.
If there is no response from a DHCP server within 30 seconds, the Auto-IP configuration mechanism attempts to allocate the default IP address 169.254.100.100. If this address is not available, it then allocates an IP address in the range of 169.254.x.y (where x is in the range 1 to 254, and y is in the range 0 to 255).
2 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 18.

Figure 18 Example top-level command line interface menu
4 At the Select menu option prompt enter the protocol ip interface summary command. At the Select IP interfaces prompt enter all. A summary of the automatically allocated IP information is displayed. Make a note of the Network IP Address.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 46.
If you do not intend to use the command line interface via the console port to manage the Switch, you can disconnect the serial cable and close the terminal emulator software.
Once you have completed the initial set up of your Switch, you can decide how you wish to manage the Switch. You can use one of the following methods:
Each Switch has a command line interface (CLI) that allows you to manage the Switch from a workstation, either locally via a console port connection (see Figure 19), or remotely over the network (see Figure 20).

Methods of Managing a Switch 47
Figure 19 CLI management via the console port

Figure 20 CLI management over the network

Refer to “Setting Up Command Line Interface Management” on page 48.
Each Switch has an internal set of web pages that allow you to manage the Switch using a Web browser remotely over an IP network (see Figure 21).
Figure 21 Web interface management over the network
Refer to “Setting Up Web Interface Management” on page 49.
SNMP Management You can manage a Switch using any network management workstation running the Simple Network Management Protocol (SNMP) as shown in Figure 22. For example, you can use the 3Com Network Supervisor software that is provided on the CD-ROM that accompanies your Switch.

Figure 22 SNMP management over the network

Refer to “Setting Up SNMP Management” on page 51.
This section describes how you can set up command line interface management using a local console port connection or over the network.
To manage a Switch using the command line interface via the local console port connection:
1 Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 40.
2 Your Switch is now ready to continue being managed and/or configured through the CLI via its console port.
To manage a Switch using the command line interface over a network using Telnet:
1 Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 34.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
4 To open a Telnet session via the DOS prompt, enter the IP address of the Switch that you wish to manage in the following format:

Setting Up Web Interface Management 49
>telnet xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If opening a Telnet session via third party software you will need to enter the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
If the login prompt does not display immediately, press Return a few times until it starts.
6 If you have logged on correctly, the top-level menu of the command line interface for the Switch you wish to manage is displayed as shown in Figure 16 on page 42.
This section describes how you can set up web interface management over the network.
Pre-requisites ■ Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 34.
To display the web interface correctly, use one of the following Web browser and platform combinations:
Table 8 Supported Web Browsers and Platforms
Windows 95 Windows 98
Netscape 6.2 ✕ ✓ ✓ ✓ ✓ ✕
Internet Explorer 5.0, 5.5 and 6.0 ✓ ✓ ✓ ✓ ✓ ✕

For the browser to operate the web interface correctly, JavaScript and Cascading Style Sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings.
To enable style sheets in Netscape Navigator 4.76 on Solaris 2.6, open Netscape Navigator and select Edit > Preferences > Fonts. Select the Use document-specified fonts, including Dynamic Fonts radio button. You should also set the font sizes as follows:
This ensures that the text spacing is correct. Finally in the Advanced category ensure that Enable JavaScript and Enable style sheets are checked.
To manage a Switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
3 Open your web browser and enter the IP address of the Switch that you wish to manage in the URL locator, for example, in the following format:
4 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
5 Click on the Device View button to display the web management options.

Setting Up SNMP Management 51
Any network management application running the Simple Network Management Protocol (SNMP) can manage a Switch if:
You can use the 3Com Network Supervisor application that is provided on the CD-ROM that accompanies your Switch to provide SNMP management for your Switch. If you use 3Com Network Supervisor it automatically loads the correct MIBs and necessary files onto your workstation.
Pre-requisites ■ Documentation supplied with the SNMP network management application software.
To manage your Switch using an SNMP network management application, you need to specify SNMP community strings for the users defined on the Switch. You can do this using the command line interface system management snmp community command — refer to the command line interface section of the “Management Interface Reference Guide” for more information.
If you intend to manage the Switch using the web interface or the command line interface, or to change the default passwords, you need to log in with a valid user name and password. The Switch has three default user names, and each user name has a different password and level of access. These default users are listed in Table 9.

Table 9 Default Users
Default Password Access Level
monitor monitor monitor — the user can view all manageable parameters, except special/security features, but cannot change any manageable parameters.
manager manager manager — the user can access and change the operational parameters but not special/security features
security — the user can access and change all manageable parameters
Use the admin default user name (no password) to login and carry out initial Switch setup.
You can change the default passwords using either:
For more information about default users and passwords, refer to the “Management Interface Reference Guide” on the Switch CD-ROM.
User Name · admin (no password)

This chapter helps you to diagnose and solve problems you may have with the operation of your Switch. There is also an explanation of IP addressing.
The topics covered are:
If you experience a problem that is not listed here, it may be included in the support section of the Superstack 3 Switch Management Interface Reference Guide on the CD-ROM that accompanies your Switch.
To ensure this product provides optimum performance, high speed fans are used to provide ventilation. These fans have a high audible output.
For Technical Support information, see Appendix D.

Solving Problems Indicated by LEDs
If the LEDs on the Switch indicate a problem, refer to the list of suggested solutions below.
Check that the power cable is firmly connected to the Switch and to the supply outlet. If the connection is secure and there is still no power, you may have a faulty power cord or an internal fault. Firstly, check the power cord by:
then contact your supplier for advice.
The Switch unit has failed its Power On Self Test (POST) because of an internal problem. The fault type will be indicated on the unit LEDs. Contact your supplier for advice.
A link is connected and yet the Status LED for the port does not light
Check that:
Auto-negotiation problems will occur with 10BASE-T or 100BASE-T where auto-negotiation is disabled and incorrect cables are being used (cross-over or straight)
Auto-negotiation problems will occur with fiber if:

Solving Hardware Problems 55
In the rare event of your Switch unit experiencing a hardware failure, refer to the list of suggested solutions below.
Ensure that the expansion module is fully seated in the slot and the connectors are engaged so that the securing screws can be tightened.
Your Switch has a fan monitoring system that will generate fan failure warning messages. Fan failure could potentially reduce the lifetime of the Switch. The monitoring system polls the fan status at periodic intervals while the unit is powered up.
Should one fan failure occur in the Switch, a warning message will be generated in the following ways:
For further information about RMON, refer to “Chapter 7: Status Monitoring and Statistics” in the Switch Implementation Guide supplied in PDF format on the CD-ROM that accompanies the Switch.
If more than one fan fails in the Switch, a warning message will be generated by RMON Email Notification, RMON Trap and also in the following ways:

If a fan failure warning message is generated:
1 Power off the unit.
2 Check that the air vents are not obstructed.
3 Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC main supply, remove and reconnect the DC RPS supply.
4 If another fan failure warning message is generated via the Command Line Interface or the Web interface, return the unit.
1 Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC mains supply, remove and reconnect the DC RPS supply.
2 Check the command line interface (system summary command) to determine whether a thermal shutdown has occurred.
3 If no, return the unit:
If yes, check that:
4 Power cycle the unit. If a further thermal shutdown occurs, and all environmental conditions are satisfactory, return the unit to 3Com.
The Switch has identified that the GBIC does not meet the minimum requirements for the Switch and has disabled the port. To correct this problem, completely remove the GBIC and replace it with a 3Com approved GBIC. See “Approved GBIC Transceivers”on page 29
To correct this problem, completely remove the GBIC and then reinsert it. If the problem persists, contact 3Com Technical Support.

Solving Communication Problems 57
If you experience communication problems with the Switch, ensure that:
The following is an brief overview of IP addressing, and how to obtain a registered IP address.
To be managed correctly, each device on your network (for example a Switch or Hub) must have a unique IP address. IP addresses have the format n.n.n.n where n is a decimal number between 0 and 255. An example IP address is 192.168.100.8.
The IP address is split into two parts:
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you access the Internet, you must apply for a registered IP address.

How do you obtain a registered IP Address?
The IP registration system ensures that every IP address used is unique; if you do not have a registered IP address, you may be using an identical address to someone else and your network will not operate correctly.
InterNIC Registration Services is the organization responsible for supplying registered IP addresses. The following contact information is correct at time of publication:
If your IP network is internal to your organization only, that is, you do not access the Internet, you may use any arbitrary IP address as long as it is not being used by another device on your network. 3Com suggests you use addresses in the series 192.160.100.X (where X is a number between 1 and 254) with a subnet mask of 255.255.255.0. These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
You can upgrade the management software of the Switch by using the System > Control > Software Upgrade operation in the Web Interface, or the system control softwareUpgrade command in the command line interface. For details on these options, refer to the Management Interface Reference Guide supplied in HTML format on the CD-ROM that accompanies your Switch.
If you have problems with your software upgrade, refer to the Problem Solving section in the Management Interface Reference Guide.

You must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the Switch 4900, 4900 SX, 4924, or 4950.

Important Safety Information
U.S.A. and Canada
Europe only: ■ The supply plug must comply with CEE 7/7 (“SCHUKO”).
Denmark ■ The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland ■ The supply plug must comply with SEV/ASE 1011.
United Kingdom only

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
WARNING: The switch should only be used in a rack if it is mounted on runners, a shelf, or a tray to support the weight. The rack mount kits alone are not sufficient to support the weight of the switch. The rack mount kits must not be used to suspend the switch from under a table or desk, or attach it to a wall.

Never look at the transmit laser while it is powered-up. Never look directly at the fiber ports and fiber cable ends when they are powered-up.

Modem Cable 9-pin to RS-232 25-pin

Pin assignments are identical for 10/100BASE-T and 1000BASE-T RJ-45 connectors.
Table 10 Pin assignments


RJ-45 Pin Assignments 71
Table 11 Pin assignments
Pin Number 10/100BASE-T 1000BASE-T
Ports configured as MDIX
1 Receive Data + Bidirectional Data B+
2 Receive Data - Bidirectional Data B-
3 Transmit Data + Bidirectional Data A+
4 Not assigned Bidirectional Data D+
5 Not assigned Bidirectional Data D-
6 Transmit Data - Bidirectional Data A-
7 Not assigned Bidirectional Data C+
8 Not assigned Bidirectional Data C-


The technical specifications for the Switches in the Switch 4900 Series are the same unless otherwise stated.
Physical Dimensions Switch 4900: Switch Height: 65.8 mm (2.59 in.) x Width: 440 mm (17.3 in.) x Depth: 363.4 mm (14.30 in.) (not including bulge). Weight: 6.3 Kg (13.88 lbs)
Switch 4900 SX: Height: 65.8 mm (2.59 in.) x Width: 440 mm (17.3 in.) x Depth: 363.4 mm (14.30 in.) (not including bulge). Weight: 6.0 Kg (13.22 lbs)
Switch 4924: Height: 65.8 mm (2.59 in.) x Width: 440 mm (17.3 in.) x Depth: 413 mm (16.27 in.) (not including bulge). Weight: 6.4 Kg (14.10 lbs)
Switch 4950: Height: 65.8 mm (2.59 in.) x Width: 440 mm (17.3 in.) x Depth: 413 mm (16.27 in.) (not including bulge). Weight: 6.91 Kg (15.23 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –10 ° to +70 °C (14 ° to 158 °F)
Operating Humidity 10–95% relative humidity, non-condensing
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL 1950 / UL60950, EN60950, CSA 22.2 No. 950 / CSA 22.2 No. 60950, IEC 60950, IEC 825-1 (4900 SX and 4950 only), EN 60825-1 (4900 SX and 4950 only)
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A, CNS 13438 Class A, EN61000-3-2
Environmental Requirements · Safety · Immunity EN 55024

AC Line Frequency 50/60 Hz
Input Voltage Options 90–240 VAC
Standards Supported SNMP:
Terminal Emulation:
SNMP protocol (RFC 1157)
Protocols Used for Administration:
Bridge MIB (RFC 1493)
RMON MIB II (RFC 2021)
IP (RFC 791)
Remote Monitoring MIB (RFC 1757)
MAU MIB (RFC 2239)
TCP (RFC 793)
ARP (RFC 826)
TFTP (RFC 783)
DHCP (RFC 2131, RFC 2132, RFC 1534)
BOOTP (RFC 951, RFC 1497)
IGMP (RFC 1112 & 2236)
RADIUS (RFC 2865, 1321, & 2869)
RMON: (RFC 2819)
Power Supply · Telnet (RFC 854)

3Com provides easy access to technical support information through a variety of services. This appendix describes these services.
Information contained in this appendix is correct at time of publication. For the most recent information, 3Com recommends that you access the 3Com Corporation World Wide Web site.
3Com offers worldwide product support 24 hours a day, 7 days a week, through the following online systems:
World Wide Web Site To access the latest networking information on the 3Com Corporation World Wide Web site, enter this URL into your Internet browser:
This service provides access to online support information such as technical documentation and software, as well as support options that range from technical education to maintenance and professional services.
The 3Com Knowledgebase is a database of technical information to help you install, upgrade, configure, or support 3Com products. The Knowledgebase is updated daily with technical information discovered by 3Com technical support engineers. This complimentary service, which is available 24 hours a day, 7 days a week to 3Com customers and partners, is located on the 3Com Corporation World Wide Web site at:

3Com FTP Site Download drivers, patches, software, and MIBs across the Internet from the 3Com public FTP site. This service is available 24 hours a day, 7 days a week.
To connect to the 3Com FTP site, enter the following information into your FTP client:
You do not need a user name and password with Web browser software such as Netscape Navigator and Internet Explorer.
If you require additional assistance, contact your network supplier. Many suppliers are authorized 3Com service partners who are qualified to provide a variety of services, including network planning, installation, hardware maintenance, application training, and support services.
When you contact your network supplier for assistance, have the following information ready:
If you are unable to contact your network supplier, see the following section on how to contact 3Com.

Support from 3Com 77
Support from 3Com If you are unable to obtain assistance from the 3Com online technical resources or from your network supplier, 3Com offers email and telephone technical support services. To find out more about your support options, email or call the 3Com technical support services at the location nearest you.
Email Support Some 3Com regions offer an email support service. To access this service for your region, use the appropriate URL or email address from the list below.
From this region, email:
apr_technical_support@3com.com
From this region, enter the URL:
http://emea.3com.com/support/email.html
Spanish speakers, enter the URL:
http://lat.3com.com/lat/support/form.html
Portuguese speakers, enter the URL:
http://lat.3com.com/br/support/form.html
English speakers, email:
lat_support_anc@3com.com
Telephone Support When you contact 3Com for assistance, have the following information ready:

Here is a list of worldwide technical telephone support numbers. These numbers are correct at the time of publication. Refer to the 3Com Web site for updated information.
Country Telephone Number Country Telephone Number
Australia Hong Kong India
1 800 678 515 800 933 486 +61 2 9424 5179 or 000800 650 1111 001 803 61009 00531 616 439 or 03 5977 7991 1800 801 777 0800 446 398 +61 2 9937 5083
1235 61 266 2602 or +61 2 9937 5076 10800 61 00137 or 021 6350 1590 or 00800 0638 3266 800 6161 463 00798 611 2230 or 02 3455 6455 00801 611 261 001 800 611 2000
P.R. of China
Singapore S. Korea
Malaysia New Zealand Pakistan
Europe, Middle East and Africa
From anywhere in these regions, call:
From the following countries, you may use the numbers shown:
Austria Belgium (Flemish) Belgium (French) Denmark Finland France Germany Hungary Ireland Israel Italy
01 7956 7124 070 700 000 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 14466 1800 509359 1800 943 2632 199 161346
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
800 29880 0900 777 7737 815 33 047 00800 441 1357 707 200 123 0800 991196 9 021 60455 07711 14453 08488 50112 0870 241 3901
Antigua Argentina Aruba Bahamas Barbados Belize Bermuda Bonaire Brazil Cayman Chile Colombia Costa Rica Curacao Ecuador Dominican Republic
1 800 988 2112 0 810 444 3COM 1 800 998 2112 1 800 998 2112 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guatemala Haiti Honduras Jamiaca Martinique Mexico Nicaragua Panama Paraguay Peru Puerto Rico Salvador Trinidad and Tobago Uruguay Venezuela Virgin Islands
AT&T +800 998 2112 57 1 657 0888 AT&T +800 998 2112 1 800 998 2112 571 657 0888 01 800 849CARE AT&T +800 998 2112 AT&T +800 998 2112 54 11 4894 1888 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 657 0888
North America 1 800 876 3266

Returning Products for Repair 79
Before you send a product directly to 3Com for repair, you must first obtain an authorization number. Products sent to 3Com without authorization numbers will be returned to the sender unopened, at the sender’s expense.
You can obtain an authorization number (called an RMA) by entering the following URL into your Internet browser:
http://www.3com.com/support/en_US/repair
Alternatively, you can obtain an RMA by calling or faxing one of the following numbers:
Country Telephone Number Country Telephone Number
From anywhere in this region call:
+ 65 543 6500 phone + 65 543 6348 fax
Europe, Middle East and Africa
From anywhere in these regions, call:
From the following countries, you may use the numbers shown:
Austria Belgium (Flemish) Belgium (French) Denmark Finland France Germany Hungary Ireland Israel Italy
01 7956 7124 070 700 000 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 14466 1800 509359 1800 943 2632 199 161346
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
800 29880 0900 777 7737 815 33 047 00800 441 1357 707 200 123 0800 991196 9 021 60455 07711 14453 08488 50112 0870 241 3901
Asia, Pacific Rim · +44 (0)1442 435529

Country Telephone Number Country Telephone Number
Antigua Argentina Aruba Bahamas Barbados Belize Bermuda Bonaire Brazil Cayman Chile Colombia Costa Rica Curacao Ecuador Dominican Republic
1 800 988 2112 0 810 444 3COM 1 800 998 2112 1 800 998 2112 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guatemala Haiti Honduras Jamiaca Martinique Mexico Nicaragua Panama Paraguay Peru Puerto Rico Salvador Trinidad and Tobago Uruguay Venezuela Virgin Islands
AT&T +800 998 2112 57 1 657 0888 AT&T +800 998 2112 1 800 998 2112 571 657 0888 01 800 849CARE AT&T +800 998 2112 AT&T +800 998 2112 54 11 4894 1888 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 657 0888
North America From U.S.A and Canada call:
1 800 876 3266 phone 1 508 323 6061 fax (not toll free)
Latin America


FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
INFORMATION TO THE USER If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.
CSA STATEMENT This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
CE STATEMENTS (EUROPE) This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC.
You must only insert a 3Com approved GBIC transceiver into the Switch. These are listed in the “Approved GBIC Transceivers” section of the Getting Started Guide.