This manual contains safety and operating instructions. Read it carefully before using the device for the first time and keep it in a safe place for future reference.
STARTIUM devices are designed for charging and starting 12V (6 element) and 24V (12 element) lead acid batteries (electrolyte, gel and AGM) :
Assembly - handle and wheels (only for the 480E, 680E & 980E) :



Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The appliance must be positioned so that the plug socket is accessible. It must be connected to a grounded outlet according to the following recommendation:
*In the event that starting a large vehicle is troublesome it may be necessary to fit a 20A plug (not included).
Recommended cable section in case of extension lead : 3 x 2.5 mm².
IMPORTANT! Before connecting to a battery, check that the device is not connected to the power supply and the switch is OFF. Secondly, check the polarity of your battery (the fuse breaks if the polarity has been reversed). Attention: The cables must not be pinched or in contact with hot or sharp surfaces.• The device does not automatically select the voltage of the battery. Ensure that the battery is connected according to the correct voltage, either 12 or 24V.

Testing the battery Before charging the battery it is possible to test the battery. Connect the red clamp on 12 or 24V in accordance with the battery voltage. The display will then show the voltage and the percentage of health. A 12V battery is at 100% of its capacity if the voltage is greater than 12.8V. It will show 0% if the voltage is lower than 11.8V.For 24V, the battery is at 100% of its capacity if its voltage is higher than 25.6V. It is at 0% if the voltage is lower than 23.6V.
Charge Once the charger is connected to the battery (see connection and disconnection), connect the red clamp on 12V or 24V, select the charging level (key 13) according to the capacity (Ah)of the battery, select the battery type (key 12).
By default the appliance is configured on the charging level "3" and battery type: "Universal".

The charge will ony start if the voltage of the battery is equal or greater than 1V. The charging progress is stated in %. 0% = Battery recovery and 100% = Battery fully charged.
Automatic restart (Can be used only when charging) Once the device is set correctly, press key 9 to start. Pressing key 9 for more than 5 seconds will enable an automatic restart in the event of a power cut. In this case the voltage LEDs (V) and the percentage LEDs (%) will flash. If the device has been started by pressing key 9 for less than 5 seconds, it will not restart automatically. In this case the LED's will light one by one. WARNING : To stop the charge in this mode press the key 9. A power cut won't stop the charge.
After use follow the recommended disconnection procedure.
UNIVERSAL function In the event that it is not possible to accurately determine the battery type (liquid, gel, AGM, Start/Stop) then we recommend that the UNIVERSAL settting is selected, this is also the default setting.
TIMER function The TIMER key (14) enables the user to choose an adjustable charging time from 10 to 120 min with a 10 min step and enables the charge to start under 1V and without battery. Warning ! • This charge is 'manual''and will only stop at the end the configured time or by disconnecting the plug from the mains or by pressing key 9. The display (2) indicates the charging time remaining in minutes and the battery voltage.
When the battery is charged, the electrolyte will 'boil'. When this occurs it is recommended to stop the charge to avoid damaging the battery.

Charging multiple batteries simultaneously You can charge multiple batteries simultaneously by connecting them in parallel. Connect the positive terminals to the red clamp and the negative terminals to the black clamp. These batteries or group of batteries must all be the same voltage, either 12 or 24V. Charging in series is not recommended.
Starting Once the starter connected to the battery (see connection and disconnection) press key 13 to select the "START ENGINE" mode. When this function is activated by pressing key 9, it will begin with a precharge.

By turning the key you activate the starter function. If your engine does not start, wait 2 minutes between two start attempts. The attempt must last a maximum of 5 seconds. Nb: A vehicle that will not start can be a problem other than a battery in poor condition. It could come from many other causes.
After use follow the recommended instructions for disconnection.
A test function of the alternator is available using key 12. It will indicate the charge capacity of the alternator by displaying the voltage and the percentage. Between 0 and 100% = The battery is not charged enough. At 100% = Alternator ok. Between 100% and 200% = Overcharge.
FUSE 100A FUSE 200A FUSE 250A

Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Error LED flashed | Power supply issue. | p.4 | |
| Error LED flashes and alarm beep | Clamps in short-circuit or polarity reversal. | p.4 | |
| Error LED flashes and alarm beep | p.4 | ||
| Error LED flashes and alarm beep | The battery is faulty. | p.4 | |
| Error LED flashes and alarm beep | Voltage error (12 -24 V) | p.4 | |
| Error LED flashes and alarm beep | Battery not detected or <1V. Display : «BAt HS» | p.4 | |
| Error LED flashes and alarm beep | After an intensive use the device goes to thermal protection. Display : «th» | p.4 | |
| The LEDs won't light up | Power supply issue. | p.4 | |
| The LEDs won't light up | The internal fuse has blown | p.4 | |
| The LEDs won't light up | The On/Off switch isn't engaged. | p.4 | |
| In START ENGINE mode, if the screen displays 0%. Restart impossible | The battery is sulphated, starting the battery is prevented to protect the vehicle electronics. | p.4 | |
| The electrolyte is boiling | The voltage selected isn't correct (12V or 24V). | p.4 | |
| The electrolyte is boiling | The battery has an element in short- circuit. | p.4 | |
| Clamp sparks | Polarity reversal | p.4 | |
| Clamp sparks | Timer mode active | p.4 |