Manuel d'utilisation / d'entretien du produit ACT ACT1000 du fabricant ACT Technology
Aller à la page of 35
Ins trucci ones de f unci o namiento e i ns ta laci ón de la s uni dades de control del acceso ACT Ins t rucci o nes de f unci o namiento e i n sta l aci ó n de las unida de s de c o ntrol del acc eso ACT Operat ing & Ins tal la tion I nstr uct ions for ACT1000/2000 Acce ss Control Unit s : http://www.
Content s Default Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………… 1 Text Entr y Key s .
Contents Door Sett ings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. ..16 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 16 Alarm s . . . . . . . . . . . . .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 1 of 32 Operating Instructions for ACT1000/2000 Access Control Units Softw are Version: 3.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 2 of 32 Operator M enu User Setup Enable Allow a user or range of users to open th e door Disable Prev ent a user or rang e of users.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 3 of 32 User Setup The User Set up menu allows the operator to enable and disable indiv i dual users, and to change the configuration information for each user.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 4 of 32 Assign PI Ns The Assign PINs function allows a different PI N to be assigned to each of the first 1000/2000 users. Initially , the PIN will be unset . Pressing the ✔ ✔ ✔ ✔ key will prom pt for the PI N for the displayed user to be entered (it will not be displayed).
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 5 of 32 One-To-One In One-To-One Mode , any known card m ay be assigned to any of the first 1000/2000 users. If the site code and card num ber are known then they may be entered in from the keypad or the card may also be presented to a reader (similar to Learn Mode).
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 6 of 32 3) Changing tim ezone Timezone 0 for next timezone At all times ✔ ✔ ✔ ✔ to select 4) Changing door com bination Door.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 7 of 32 Display Log The Di splay Log function allows the operator to view ev ents in the historical log directly on the LCD display .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 8 of 32 Control Door The Control Door menu allows the operator to control the door or externally connected equipment such as lig hting or heating. Lock Door The Lock Door function causes the door relay to be de- energized.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 9 of 32 Clear All (ACT2000 Only ) This function manually remov es all users from the area. An event is log ged for track ing. This is typically used at the end of a day or week to remov e any users from the sy stem who have neglected to use their cards when exiting .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 10 of 32 1) Select Timezone Timezone 3 0 for next timez one Inactive ✔ ✔ ✔ ✔ to edit timez one 2) Select period A B C D E + .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 11 of 32 Issue Number This option allows the user to set the current sy stem issue level to a number between zero (default) and 255. Only cards that have an issue number g reater than or equal to the sy stem issue level will be granted access.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 12 of 32 Installer Menu System Settings Operation PIN Only PIN’s alon e are used to gain acces s Learn Users 1-1/ 2000 may use random coded cards Ext. Keypad 1 Use extern al ACT20 keypad KPD Re lease 1 ✔ ✔ ✔ ✔ Key is exit button.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 13 of 32 Door Settings* Timers Relay Time Time for w hich relay is active (contd.) OP 2 Time T ime f o r w hich OP2 is active OP3 Ti.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 14 of 32 System Settings The System Settings menu allows the installer to access a number of different config uration menus controlling different aspects of the setup of the controller.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 15 of 32 Fire Doors This function allows a group of doors (or all doors) to be configured for fire ov erride. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1 .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 16 of 32 Door Settings The Door Settings m enu allows the installer to access a number of different configuration menus controlling different aspects of the selected door.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 17 of 32 Timers The door tim ers menu allows the installer to prog ram the tim e delays for the relay, AUX output, open collector outputs OP2 and OP3 and the door ajar alarm time. Each timer m ay be program med with a duration from 1 to 999 seconds .
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 18 of 32 High Speed Comm unications on the controller defaults to 9600 baud. The high speed option sets the controller to operate at 19200 baud. This option applies to direct connect to a PC, networked interface and printer modes of operation.
ACT1000/2000 Operati ng Instructi ons Software Version 3.23-00 Page 19 of 32 Site Code 1 This function allows the 8-digit site prim ary code for the system to be entered. The controller will recogniz e only cards with a matching site code. This code should also be quoted whenever additional cards or tag s are being ordered for this installation.
Card or Proximity Reader SENSE CLOCK DA T A +5V 0V RED GREEN V olt Free T amper Contacts +12V 0V PUSH BUTTON DOOR CONT ACT INTER LOCK 0V OP2 OP3 BUZZER 12V+ DC- RELA Y N/C C N/O NETWORK PRINTER T AMPER T imekeeper Lithium Battery A B 0V TX RX OMRON 5A 250V AC 5A 30VDC BA TCH: 96XX-1 PRODUCT : ACT 1000 REV1.
1A 250VAC 1A 30VDC 0 1 2 3 4 5 6 7 8 9 BATCH: PRODUCT: SERIAL NUMBER: 98XX-1 ACT2000 REV2.1 00XXXX 0V DOOR CONTACT PUSH BUTTON AUX INPUT RELAY 1 N/C N/O C OP2 OP3 SENSE CLOCK DATA RED GREEN ENTRY/EXIT.
T o set the door number , set address switches 4-8 as shown NETWORK Important ! Always Place V aristor Across Lock T erminals Door Release Button A B A Shield F ACTORY DEF AUL T This unit should be reset to its factory default condition before installation.
Card / Proximity or Pin Reader (Entry) Card or Proximity Reader (Exit) Controller SENSE CLOCK DA T A +5V 0V RED GREEN Card/Prox Reader 2 3 1 5 6 4 8 9 7 0 For Wiegand Exit readers Connect DA T A 0 of the exit reader to SENSE on the controller . Leave SENSE on the readers unconnected.
Cable: 8 Core Screened, Max 30m Controller ENTRY/EXIT READER 0 1 2 3 4 5 6 7 8 9 BATCH: PRODUCT: SERIAL NUMBER: 98XX-1 ACT20 REV2.1 012345 OP2 OP3 BUZZER 0V 0V DOOR CONTACT PUSH BUTTON INTERLOCK (PB2).
Max cable length is 5m using standard alarm cable or 30m using twin twisted-pair (use 0V in each pair) DB25 Male (Rear View) 7 2 3 Serial Modem Cable (Modem to Controller) ACT 1000/2000 3 W ay Pluggab.
LED2 LED1 DOOR I/O SERIAL NETWORK ENTRY/EXIT READER GENERAL I/O RELA Y T AMPER MAINS +12V 0V N/C C AUX RL Y N/ON/C C N/O SENSE CLOCK DAT A +5V 0V RED GREEN 5A 250V AC 5A 30VDC 5A 250V AC 5A 30VDC PUSH.
ACTWinPro Configuration A B 0V TX RX NETWORK DOORS A B 0V SERIAL/PRINTER 0V DTR RED GREEN ACT WinPr o From the Installer Menu, do the following: 1. Factory Default the controller. 2. Go to the Communications menu and Set Address. If there is only 1 controller, set the address to 1.
T o PC T o Mains Supply ACT 4-Line Nework Interface Card All lines are equivalent and operate in parallel Any controller may be connected to any line. Network cable is single shielded twisted pair: Be.
Setup for Netw or k Oper ation 4 3 2 1 BAUDRA TE SELECT 9600 19200 Network cable is single shielded twisted pair: Belden 9501 or similar ACT 2000 ACT 1000 ACT 1000 NETWORK PRINTER T imekeeper Lithium .
DB25 Male (Rear View) 7 3 2 Max cable length is 5m using standard alarm cable or 30m using twin twisted-pair (use 0V in each pair) Direct Connection fr om Modem to Controller Connections for 25 Way male Connector RX = Pin 3 TX = Pin 2 0V = Pin 7 1. Connect Modem Cable directly to ACT1000/2000 and Modem 2.
ACT WinPr o Software 1. Ask the network administrator to supply you with a permanent IP network address. 2. Connect a PC directly to the ACTLAN and run HyperT erminal at 9600 baud, no parity , 1 stop. 3. Power up the ACTLAN and immediately hit 3 lowercase "x" (xxx).
PSTN RS232 ACTWinPro Door 16 ACT 2000 DS100 DS100 DS100 Door 3 Door 4 Door 2 Door 1 485 Converter System Diagram: Illustrating some of the ways to connect ACT Controllers to a computer.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ACT Technology ACT ACT1000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ACT Technology ACT ACT1000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ACT Technology ACT ACT1000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ACT Technology ACT ACT1000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ACT Technology ACT ACT1000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ACT Technology ACT ACT1000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ACT Technology ACT ACT1000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ACT Technology ACT ACT1000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.