FR
Constructa logo
Notice d'utilisation officielle

Constructa CD96350

48 pages·3.9 MB·Hotte de cuisine·PDF·ENJA
Constructa CD96350
Table des matières 10 sections Operating modes · Before using for the first time · If you encounter a problem · Installation Instructions: · … AfficherMasquer
Page 1 of the Constructa CD96350 user manual — If you encounter a problem
Page 1 · cliquer pour agrandir
Page 1
Constructa CD96350 — Operating modes diagram (page 1)
Fig. 1 · Operating modes

Operating modes

Before using for the first time

Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Do not flambé food directly under the extractor hood.

Circulating-air modeq An activated carbon filter must be fitted

for this operating mode (see Filters and maintenance). The complete installation set and replacement filters can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. q The extractor-hood fan extracts the

Risk of grease filter catching fire due ! to flames. The hotplates must always be covered with a utensil.

kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen. q The grease filter absorbs the grease

Constructa CD96350 — Operating modes diagram (page 1)
Fig. 2 · Operating modes

time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance. q Please retain the operating and

particles in the kitchen vapours. q The activated carbon filter binds the

Operating modes

odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours.

installation instructions for a subsequent owner. Do not use the appliance if damaged.

Exhaust-air modeq The extractor-hood fan extracts the

kitchen vapours and conveys them through the grease filter into the atmosphere. q The grease filter absorbs the solid

Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).

particles in the kitchen vapours. q The kitchen is kept almost free of grease

Before using for the first time

and odours. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).

Gas hobs / Gas cookers Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.

versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. q This extractor hood complies with all

relevant safety regulations. Repairs should be carried out by qualified technicians only. Improper repairs may put the user at considerable risk.

This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air- intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.

The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his custo- mer service or a similarly qualified person in order to prevent serious injury to the user. The appliance may be connected to the mains by a qualified technician only. Dispose of packaging materials properly (see Installation instructions). This extractor hood is designed for domestic use only. Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading.

If you encounter a problem

If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the following:

E-Nr. FD

Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached.

Page 2 of the Constructa CD96350 user manual — Operating modes
Page 2 · cliquer pour agrandir
Page 2
Constructa CD96350 — Operating modes diagram (page 2)
Fig. 3 · Operating modes

The most effective method of removing vapours produced during cooking is to: q Switch the ventilator ON

Grease filters:

2. Clean the filters. 3. Insert the clean filters back into the hood.

Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from non- combustible metal.

as soon as you begin cooking. q Switch the ventilator OFF

Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting.

Fan OFF Light ON / OFF

Reduce fan speed Fan ON and increase speed Intensive setting Display for fan setting

Installation and removal: Warning: The halogen bulbs must be switched off and cool. 1. Remove the metal filters (see "Removing and inserting the metal grease filters"). 2. Insert the activated carbon filter.

Cleaning the metal grease filtersq In normal operation (1 to 2 hours daily),

Switching the fan ON q Press the + button.

the metal grease filter must be cleaned 1 x a month. q The filters can be cleaned in a dish-

Setting the required fan speed: q Press the + button.

washer. It is however possible that they will become slightly discoloured. q The filter must be placed loosely, and

The fan speed is increased by one step. q Press the – button.

Constructa CD96350 — Operating modes diagram (page 2)
Fig. 4 · Operating modes

The fan speed is reduced by one step.

NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. q When cleaning the filters by hand, soak

Switching the fan OFF: q Press the 0 button.

Orq Keep pressing the – button until the fan

switches off.

them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off.

Intensive setting: Maximum power is obtained at the intensive setting. It is only required for short intervals. q Keep pressing the + button until a ç

3. Engage the lug at the front. 4. Insert the metal grease filters (see "Removing and inserting the metal grease filters").

appears in the display. q If the intensive setting is not cancelled by

Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. 1. Press the catch on the grease filters inwards and fold the filters down. At the same time take hold of the under- side of the grease filters with your other hand.

hand, the fan will automatically switch back to step } after 10 minutes. Lighting: q The light can be switched on at any

Replacing the activated carbon filterq During normal operation (1 to 2 hours

per day) the activated carbon filters should be replaced approximately 1 x year. q A replacement filter can be obtained

time, even though the fan is switched off.

from any authorized dealer (see optional accessories). q Use original filters only.

Constructa CD96350 — Operating modes diagram (page 2)
Fig. 5 · Operating modes

By doing so you will obtain maximum performance from your extractor hood.

Disposing of the old activated carbon filter: q There are no pollutants in the activated

carbon filters. They can therefore be disposed of as part of your normal domestic refuse.

Page 3 of the Constructa CD96350 user manual — Installation Instructions:
Page 3 · cliquer pour agrandir
Page 3

Installation Instructions:

Cleaning and care

Replacing the light bulbs

Important information

Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! q Clean the extractor hood with a hot soap

1. Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box. When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off there is still a risk of burns. 2. Remove the bulb ring with a screwdriver or similar tool.

Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 550 mm, Fig. 1. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.

solution or a mild window cleaner. q Do not scrape off dried-on dirt but wipe

off with a damp cloth. q When cleaning the grease filters, remove

grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. q Note: Do not use alcohol (spirit) on

plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is ade- quately ventilated. Avoid naked flames! Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons.

3. Replace the halogen light bulb (conventional halogen bulb, 12 Volt, max. 20 Watt, G4 cap). Caution: Refer for plug-in lampholder. Take hold of the bulb with a clean cloth.
Stainless steel surfacesq Use a mild non-abrasive stainless steel

cleaner. q Clean the surface in the same direction

as it has been ground and polished. q We recommend our stainless steel

cleaner no. 461731. See enclosed service booklet for order address.

4. Re-insert the bulb ring. 5. Plug the appliance into the mains or switch it on at the fuse box. Note: I f the light does not function, check that the bulbs have been inserted correctly.

Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1.

Aluminium and plastic surfaces: q Do not use dry cloths. q Use a mild window cleaning agent. q Do not use aggressive, acidic or caustic

cleaners.

Observe the warranty regulations in the enclosed service booklet.

Page 4 of the Constructa CD96350 user manual — Prior to installation
Page 4 · cliquer pour agrandir
Page 4

Prior to installation

Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall.

Constructa CD96350 — Prior to installation diagram (page 4)
Fig. 6 · Prior to installation

120 150 120 150

For optimum extractor hood efficiency: q Short, smooth air exhaust pipe. q As few bends in the pipe as possible. q Diameter of pipe to be as large as

pipeq Mount the pipe directly onto the air

possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise.

Connecting a l 120 mm exhaust-air pipe: q Attach the reducing connector directly to

The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. q Round pipes:

The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations). Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).

We recommend Internal diameter150 mm (at least 120 mm). q Flat ducts must have an internal cross-

section that equates to that of round pipes. There should be no sharp bends. l 120 mm approx. 113 cm2 l 150 mm approx. 177 cm2

q If pipes have different diameters:

Insert sealing strip. q For exhaust-air mode, ensure that

Preparing the wall q The wall must be flat and perpendicular. q Ensure that the wall is capable of

there is an adequate supply of fresh air.

Circulating-air mode q With activated carbon filter if exhaust-air

providing a firm hold for mounting screws and plugs.

mode is not possible.

The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these opera- ting instructions.

Weight in kg:

Exhaust air Recirculating air

19,2 18,7 60 cm

This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air- intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.

19,8 19,3 70 cm

20,9 20,4 90 cm

We reserve the right to construction changes within the context of technical development.

Exhaust-air mode

Page 5 of the Constructa CD96350 user manual — Electrical connection
Page 5 · cliquer pour agrandir
Page 5

Electrical connection

Installation

This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Use the template to mark the points on the wall where the screws will be mounted. In order to make it easier to hook the hood onto the screws, draw the outline of the area where the hood will be attached. Ensure that the minimum distance bet- ween the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood. 4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall.

7. Attach the extractor hood. Adjust the height and align horizontally with the adjusting screws.

Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red.

The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. q The earthed socket should be

08. Screw in lower screws (hex screws). 09. Stick protective film over the holes of the 2 lower mounting bolts in the protective grid.

connected via its own circuit. q If the earthed socket is no longer

accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector.

If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.

10. Connect up the air outlet pipe. 11. Connect the hood to the electricity supply. 12. Remove the protective film from the two flue ducts. Take care not to damage the stainless steel surfaces which are susceptible to scratches etc. 13. Insert the upper flue duct (slots downwards) into the lower flue duct. Protect the cover panels from scratches, for example by laying the template used for marking the wall over the top edge of the lower section.

Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. This extractor hood corresponds to EC regulations concerning RF interference suppression.

Constructa CD96350 — Electrical connection diagram (page 5)
Fig. 7 · Electrical connection
Page 6 of the Constructa CD96350 user manual — Installation
Page 6 · cliquer pour agrandir
Page 6

Installation

Constructa CD96350 — Installation diagram (page 6)
Fig. 8 · Installation
14. Insert the complete flue duct at an angle into the glass shield and swivel backwards.
15. Carefully pull the upper flue duct upwards and screw the sides to the fixing bracket with 2 screws.
16. Insert the grease filter (refer to Operating Instructions).
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Constructa CD96350

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Constructa CD96350

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Constructa CD96350 manuel PDF

48 pages·3.9 MB·Hotte de cuisine·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%