Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners.
In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
catch fire. Clean the grease filter at least every 2 months.
Never operate the appliance without the grease filter.
catch fire. Never work with naked flames close to the appliance (e.g. flambéing). Do not install the appliance near a heat- producing appliance for solid fuel (e.g. wood or coal) unless a closed, non- removable cover is available. There must be no flying sparks.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.
Risk of fire! ■Hot oil and fat can ignite very quickly.
Never leave hot fat or oil unattended. Never use water to put out burning oil or fat. Switch off the hotplate. Extinguish flames carefully using a lid, fire blanket or something similar.
any cookware placed on them, they can build up a lot of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Only operate the gas burners with cookware on them.
always be ensured.
will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.
same time gives rise to a great deal of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Never operate two gas burners simultaneously on the highest flame for longer than 15 minutes. One large burner of more than 5 kW (wok) is equivalent to the power of two gas burners.

Risk of burns! The accessible parts become very hot when in operation. Never touch hot parts. Keep children at a safe distance.
may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
have sharp edges. Wear protective gloves.
Risk of electric shock! ■ Do not use any high-pressure cleaners or
down. Do not place any objects on the appliance.
steam cleaners, which can result in an electric shock.
Causes of damage
dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.
Risk of damage due to corrosion. Always switch on the appliance while cooking to avoid condensation. Condensate can produce corrosion damage.
Always replace faulty bulbs to prevent the remaining bulbs from overloading.
Risk of damage due to ingress of humidity into the electronic circuitry. Never clean operator controls with a wet cloth.
shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the direction of the grain only. Do not use any stainless steel cleaners for operator controls.
Surface damage due to strong or abrasive cleaning agents. Never use strong and abrasive cleaning agents.
Risk of damage from returning condensate. Install the exhaust duct in such a way that it falls away from the appliance slightly (1° slope).
Your new appliance is particularly energy-efficient. Here you can find tips on how to save even more energy when using the appliance, and how to dispose of your appliance properly.
so that the extractor hood can work efficiently and with a low level of operating noise.
Only use intensive mode where this is required. A lower fan speed means that less energy is consumed.
speed in good time. If cooking fumes have already spread in the kitchen, the extractor hood must be operated for longer.
order to increase the effectiveness of the ventilation system and to prevent the risk of fire.
Dispose of packaging in an environmentally-friendly manner.
This appliance is labelled in accordance with European Directive 2012/19/EU concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.

This appliance can be used in exhaust-air mode or circulating- air mode.
smoke or exhaust gas flue, obtain the consent of the heating engineer responsible.
telescopic wall box should be used.
The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system. The air which is drawn in is cleaned by the grease filters and an activated carbon filter, and is conveyed back into the kitchen.
These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance.


- Reduces the fan speed
+ Increases the fan speeds/intensive setting
0, A Light on/off
Pull out the filter pull-out and press the # button. The fan starts at setting 2.
1 Fan speed 1
2 Fan speed 2
Press the + or - button to change the fan strength.
3 Fan speed 3
Press the # button. Slide the filter pull-out in.
Pull out the filter pull-out. The fan starts at the selected level.
Press buttons 1, 2 or 3 in order to change the fan strength.
Slide the filter pull-out in as far as the limit stop.

Fan run-on time
You can use the intensive setting if there is a large build-up of odours and fumes/vapours.
If you slide in the filter pull-out, the run-on time will be activated for as long as the extractor hood is operating.
Press the + button until all of the LEDs in the display light up. The intensive setting is activated.
After approx. 10 minutes, the fan switches off automatically.
After approx. six minutes, the electronics automatically reduce the fan to a lower setting . If you want to end the intensive setting before the preset time expires, press the - button until the required fan setting is reached.
The lighting can be switched on and off independently of the ventilation.
Press the A button.
The run time is limited. The fan is then automatically reduced to a lower fan setting. You can switch back manually at any time.
: Risk of burns!
The appliance will become hot during operation, especially near the bulbs. Allow the appliance to cool down before cleaning.
Glass Glass cleaner: Clean with a soft cloth. Do not use a glass scraper.
Controls Hot soapy water: Clean using a damp dish cloth and dry with a soft cloth/towel.
Penetrating moisture may result in an electric shock. Clean the appliance using a damp cloth only. Before cleaning, pull out the mains plug or switch off the circuit breaker in the fuse box.
Risk of electric shock caused by pene- trating moisture.
Risk of damage to the electronics from penetrating moisture. Never clean operating controls with a wet cloth.
Do not use any high-pressure cleaners or steam cleaners, which can result in an electric shock.
Do not use any stainless steel cleaners.
Components inside the appliance may have sharp edges. Wear protective gloves.
These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. : Risk of fire!
To ensure that the different surfaces are not damaged by using the wrong cleaning agent, observe the information in the table. Do not use any of the following:
Grease deposits in the grease filter may catch fire. Clean the grease filter at least every 2 months. Never operate the appliance without the grease filter.
agents.
Wash new sponge cloths thoroughly before use.
holder for the metal mesh grease filters in the appliance using a damp cloth.
Follow all instructions and warnings included with the cleaning agents.
dishwasher or by hand.
By hand:
Stainless steel Hot soapy water: Clean with a dish cloth and then dry with a soft cloth.
Clean stainless steel surfaces in the grind direction only.
Special stainless steel cleaning prod- ucts are available from our after-sales service or from specialist retailers. Apply a very thin layer of the cleaning product with a soft cloth.
In the dishwasher:
Painted surfaces Hot soapy water: Clean using a damp dish cloth and dry with a soft cloth/towel.
Do not use any stainless steel cleaners.
with utensils.
Glass cleaner: Clean with a soft cloth.
The metal mesh grease filters must not be wedged in.
Area Cleaning agent · Area Cleaning agent · Aluminium and plas- tic

dripping out.
On appliances with a glass plate in the filter pull-out:


the dishwasher.




Malfunctions often have simple explanations. Please read the following notes before calling the after-sales service. : Risk of electric shock!
These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. : Risk of burns!
Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
Halogen bulbs become very hot when switched on. There is still a risk of burning for some time after they have been switched off. Allow the halogen bulbs to cool down before replacing them.
Problem Possible cause Solution
The appliance does not work
The plug is not plugged in.
Connect the appliance to the electricity supply
When changing the bulbs, the bulb socket contacts are live. Before changing the bulb, unplug the appliance from the mains or switch off the circuit breaker in the fuse box.
Power cut Check whether other kitchen appliances are working
Faulty fuse Check in the fuse box to make sure that the fuse for the appliance is OK
The lighting does not work.
The bulbs are faulty.
For information on chang- ing the bulbs, see the "Replacing Bulbs" section.
· Replacing halogen bulbs

Defective LED lights may be replaced by the manufacturer, their customer service or a qualified technician (electrician) only. : Risk of injury!

The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.
Our after-sales service is there for you if your appliance needs to be repaired. We will always find the right solution in order to avoid unnecessary visits from a service technician.
(not included in the scope of delivery)
When calling us, please give the product number (E no.) and the production number (FD no.) so that we can provide you with the correct advice. The rating plate with these numbers can be found inside the appliance (remove the metal mesh grease filter to gain access).
You can make a note of the numbers of your appliance and the telephone number of the after-sales service in the space below to save time should it be required.
Basic equipment:
Starter set for circulating-air mode
E no. FD no.
Throw-away filter for starter set
Please be aware that a visit by an after-sales engineer will be charged if a problem turns out to be the result of operator error, even during the warranty period.
Please find the contact data of all countries in the enclosed customer service list.
Rely on the professionalism of the manufacturer. You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances.

Installation instructions These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance.
Appliance width 60 cm:


special accessories (e.g. for circulating-air mode).
them during installation.



Appliance width, 90 cm:





Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location. The width of the extractor hood must correspond at least with the width of the hob. For the installation, observe the currently valid building regulations and the regulations of the local electricity and gas suppliers. When conveying the exhaust air, official and legal regulations (e.g. state building regulations) must be followed.
open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.
always be ensured.
will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.
Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.
In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the

Risk of fire! Grease deposits in the grease filter may catch fire. The specified safety distances must be observed in order to prevent an accumulation of heat. Observe the specifications for your cooking appliance. If gas and electric hobs are operated together, the largest specified distance applies. Only one side of the appliance may be installed directly next to a high-sided unit or a wall. The distance between the appliance and wall or high-sided unit must be at least 50 mm.
Risk of electric shock! Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.
Risk of electric shock! It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket that has been correctly installed. If the plug is no longer accessible once the appliance has been installed, or a fixed connection is required, the installation must have an all-pole isolating switch with a contact gap of at least 3 mm. Only an electrician may install the fixed connection. We recommend installing a residual-current circuit breaker (RCCB) in the appliance's power supply circuit.
have sharp edges. Wear protective gloves.
Risk of injury! ■The appliance may fall down if it has not
been properly fastened in place. All fastening components must be fixed firmly and securely.
appliance, 2 people are required. Use only suitable tools and equipment.
Exhaust air mode : Risk of death!
of a short, straight exhaust air pipe and as large a pipe diameter as possible.
Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.
or pipe diameters that are smaller than 150 mm, the optimum extraction performance is not achieved and fan noise is increased.
consist of non-combustible material.
Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended.
If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used.
Flat ducts The inner cross-section must correspond to the diameter of the round pipes.
150 mm diameter, approx. 177 cm2
120 mm diameter, approx. 113 cm2
Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.
The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter.
This appliance complies with the EC interference suppression regulations.

It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket that has been correctly installed. If the plug is no longer accessible once the appliance has been installed, or a fixed connection is required, the installation must have an all-pole isolating switch with a contact gap of at least 3 mm. Only an electrician may install the fixed connection. We recommend installing a residual-current circuit breaker (RCCB) in the appliance's power supply circuit.


capacity.
Appliance dimensions and safety clearances
If the installation instructions for the gas cooking appliances specify a different distance, the largest distance must always be provided for.
The fitted unit must be heat-resistant up to 90 °C. The fitted unit must still be sturdy after the cut-outs have been made. To install an upper cabinet, this extractor hood must be provided with the following dimensions:

Depth Min. 320 mm
Height Min. 390 mm
A handle strip must be screwed to the filter pull-out. This handle strip can be one that is provided with the appliance, or one that is available as an accessory.

Width 600 mm














hood's housing.
after-sales service.

Appliance width, 90 cm:
You must also screw the appliance onto the side upper cabinets.

Change the filter pull-out's limit stop
On some versions of the appliance, the limit stop for the filter pull-out can be changed. Spacers are included with these appliances in order to set the appliance's handle strip so that it is flush with the fitted unit.



Exhaust-air pipe Ø 150 mm (recommended size)
Attach the exhaust-air pipe directly to the air-pipe connector and seal.
Exhaust-air pipe Ø 120 mm
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.