FR
Constructa logo
Notice d'utilisation officielle

Constructa CD959652

52 pages·3.2 MB·Hotte de cuisine·PDF·ENITJA
Constructa CD959652
Table des matières 192 sections Ú Table of contents[en] Instructions for installation and use · Instruction manual · : Important safety information · Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. · … AfficherMasquer
Ú Table of contents[en] Instructions for installation and usep.1Instruction manualp.1: Important safety informationp.1Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners.p.1The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.p.1This appliance is intended for domestic use and the household environment only. The appliance is not intended for use outside. Do not leave the appliance unattended during operation. The manufacturer is not liable for damage which is caused by improp...p.1This appliance may be used by children over the age of 8 years old and by persons with reduced physical, sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsi...p.1Children must not play with, on, or around the appliance. Children must not clean the appliance or carry out general maintenance unless they are at least 8 years old and are being supervised.p.1Keep children below the age of 8 years old at a safe distance from the appliance and power cable.p.1Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transport.p.1This appliance is not intended for operation with an external clock timer or a remote control.p.1Danger of suffocation!p.1Packaging material is dangerous to children. Never allow children to play with packaging material.p.1Danger of death!p.1Risk of poisoning from flue gases that are drawn back in.p.1Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air-dependent heat-producing appliance is being operated.p.1Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air t...p.2In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked ...p.2■ Adequate incoming air must therefore always be ensured.p.2■ An incoming/exhaust air wall box alone will not ensure compliance with the limit.p.2Safe operation is possible only when the partial vacuum in the place where the heatproducing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that can...p.2In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you.p.2Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.p.2Risk of fire!p.2■ Grease deposits in the grease filter may catch fire.p.2Clean the grease filter at least every 2 months.p.2Never operate the appliance without the grease filter.p.2■ Grease deposits in the grease filter may catch fire. Never work with naked flames close to the appliance (e.g. flambéing). Do not install the appliance near a heatproducing appliance for solid fuel (e.g. wood or coal) unless a closed, nonrem...p.2■ Hot oil and fat can ignite very quickly. Never leave hot fat or oil unattended. Never use water to put out burning oil or fat. Switch off the hotplate. Extinguish flames carefully using a lid, fire blanket or something similar.p.2■ When gas burners are in operation without any cookware placed on them, they can build up a lot of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Only operate the gas burners with cookware on them.p.2■ Operating several gas burners at the same time gives rise to a great deal of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Never operate two gas burners simultaneously on the highest flame for longer t...p.2Risk of burns!p.2The accessible parts become very hot when in operation. Never touch hot parts. Keep children at a safe distance.p.2Risk of injury!p.2■ Components inside the appliance may have sharp edges. Wear protective gloves.p.2■ Items placed on the appliance may fall down. Do not place any objects on the appliance.p.2■ The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.p.2Risk of electric shock!p.3■ A defective appliance may cause electric shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.p.3■ Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker...p.3■ Do not use any high-pressure cleaners or steam cleaners, which can result in an electric shock.p.3Causes of damagep.3Caution!p.3Always replace faulty bulbs to prevent the remaining bulbs from overloading.p.3Risk of damage due to ingress of humidity into the electronic circuitry. Never clean operator controls with a wet cloth.p.3Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the direction of the grain only. Do not use any stainless steel cleaners for operator controls.p.3Surface damage due to strong or abrasive cleaning agents. Never use strong and abrasive cleaning agents.p.3Risk of damage from returning condensate. Install the exhaust duct in such a way that it falls away from the appliance slightly (1° slope).p.3Environmental protectionp.3Environmentally-friendly disposalp.3Operating modesp.3This appliance can be used in exhaust-air mode or circulatingair mode.p.3Exhaust air modep.3Notep.3Circulating-air modep.3Notesp.3Operationp.4Notep.4Control panelp.4Setting the fanp.4Intensive settingp.4Fan run-on timep.4Lightingp.4Audible signalp.4When the fan is switched off, press the # and + at the same time for approx. three seconds. An acknowledgement signal sounds.p.4Repeat the "Switching on the acoustic signal" process.p.4Cleaning and maintenancep.4: Risk of burns!p.4: Risk of electric shock!p.4: Risk of electric shock!p.4: Risk of injury!p.4Cleaning agentsp.4Cleaning the metal mesh grease filtersp.5: Risk of fire!p.5Notesp.5In the dishwasher:p.5Notep.5By hand:p.5Notep.5Removing metal grease filterp.51. Open the lock and fold down the metal grease filter. While doing this, place the other hand under the metal grease filter.p.52. Take the metal grease filter out of the holder.p.5For edge extraction filters, pull the metal grease filter downwards. While doing this, place the other hand under the metal grease filter.p.5For additional filters, open the lock and fold down the metal grease filter. While doing this, place the other hand under the metal grease filter.p.5Notesp.53. Clean the metal grease filter.p.5Installing the metal mesh grease filterp.51. Insert the metal mesh grease filter.p.52. Fold the metal mesh grease filter upwards, locking it in place.p.5Trouble shootingp.6: Risk of electric shock!p.6Malfunction tablep.6Replacing bulbsp.6: Risk of electric shock!p.6Important Only use a bulb of the same type and same power (see the bulb holder or rating plate inside the appliance) – to do this, remove the metal mesh grease filter.p.6Replacing halogen bulbsp.6Notep.61. Carefully remove the bulb ring using a suitable tool.p.62. Pull out the bulb and replace it with a bulb of the same type.p.63. Insert the bulb cover.p.64. Insert the mains plug or switch on the fuse again.p.6LED lightsp.6Defective LED lights may be replaced by the manufacturer, their customer service or a qualified technician (electrician) only.p.6: Risk of injury!p.6After-sales servicep.7Rely on the professionalism of the manufacturer. You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances.p.7Accessories for circulating-air modep.7Notesp.7Basic equipment: Starter set for circulating-air mode - narrowp.7Throw-away filterp.7Basic equipment: Starter set for circulating-air mode - widep.7Throw-away filterp.7Basic equipment: CleanAir recirculation module - narrowp.7Throw-away filterp.7Basic equipment: CleanAir recirculation module - widep.7Throw-away filterp.7Installation instructionsp.8: Important safety informationp.8Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners.p.8The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.p.8The width of the extractor hood must correspond at least with the width of the hob.p.8For the installation, observe the currently valid building regulations and the regulations of the local electricity and gas suppliers.p.8When conveying the exhaust air, official and legal regulations (e.g. state building regulations) must be followed.p.8Risk of death!p.8Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust ...p.8Danger of death!p.8Risk of poisoning from flue gases that are drawn back in.p.8Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air-dependent heat-producing appliance is being operated.p.8Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coaloperated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air t...p.9In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked ...p.9■ Adequate incoming air must therefore always be ensured.p.9■ An incoming/exhaust air wall box alone will not ensure compliance with the limit.p.9Safe operation is possible only when the partial vacuum in the place where the heatproducing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that can...p.9In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you.p.9Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.p.9Danger of death!p.9Risk of poisoning from flue gases that are drawn back in. If installing a ventilation system in a room with a heat-producing appliance connected to a chimney/flue, the electricity supply to the hood must be equipped with a suitable safety switch.p.9Risk of fire!p.9Grease deposits in the grease filter may catch fire. The specified safety distances must be observed in order to prevent an accumulation of heat. Observe the specifications for your cooking appliance. If gas and electric hobs are operated together, t...p.9Only one side of the appliance may be installed directly next to a high-sided unit or a wall. The distance between the appliance and wall or high-sided unit must be at least 50 mm.p.9Risk of injury!p.9■ Components inside the appliance may have sharp edges. Wear protective gloves.p.9■ The appliance may fall down if it has not been properly fastened in place. All fastening components must be fixed firmly and securely.p.9■ The appliance is heavy. To move the appliance, 2 people are required. Use only suitable tools and equipment.p.9Risk of electric shock!p.9Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.p.9Risk of electric shock!p.9It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of ...p.9Danger of suffocation!p.9Packaging material is dangerous to children. Never allow children to play with packaging material.p.9General informationp.10Exhaust air modep.10: Risk of death!p.10Exhaust ductp.10Notep.10Preparing the ceilingp.10Electrical connectionp.10: Risk of electric shock!p.10The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter.p.10Length of the cable: approx. 1.30 mp.10This appliance complies with the EC interference suppression regulations.p.10: Risk of electric shock!p.10Installationp.11Fitting the upper support framep.111. Before fitting, determine the total height of the support frame and mark the screw holes.p.11Notep.112. On the ceiling, mark the centre point of the appliance.p.113. Using the enclosed template, mark the positions for the screws on the ceiling.p.114. Drill four 8 mm diameter holes to a depth of 80 mm for the fasteners and press in the wall plugs flush with the ceiling.p.115. Fasten the upper part of the support frame to the ceiling with 4 screws.p.11Notep.11Fitting the lower support framep.11Notesp.11Fitting the appliancep.121. Hook the appliance from below into the support frame.p.12Notep.122. Fasten the appliance to the support frame using 2 securing screws.p.123. Hook in the retaining clip and screw tight.p.12Connecting the pipesp.12Notep.12Exhaust-air pipe Ø 120 mmp.121. Attach the reducing connector directly to the air-pipe connector.p.122. Attach the exhaust air pipe to the reducing connector.p.123. Seal both joints appropriately.p.12Attaching the flue ductp.12: Risk of injury!p.121. Separate the flue ducts.p.122. Remove the protective foil from both sides.p.123. Place both parts of the upper flue on the appliance and push together.p.12Notep.124. Push up the upper flue part and secure with 2 screws.p.125. Insert both lower parts of the flue and push together.p.12
Page 1 of the Constructa CD959652 user manual — : Important safety information
Page 1 · cliquer pour agrandir
Page 1

Ú Table of contents [en]Instructions for installation and use

INSTRUCTION MANUAL 14

INSTALLATION INSTRUCTIONS............................................. 21

INSTRUCTION MANUAL

Produktinfo Additional information on products, accessories, replacement parts and services can be found at www.constructa.de and in the online shop www.constructa-eshop.com

: Important safety information

Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location. This appliance is intended for domestic use and the household environment only. The appliance is not intended for use outside. Do not leave the appliance unattended during operation. The manufacturer is not liable for damage which is caused by improper use or incorrect operation. This appliance may be used by children over the age of 8 years old and by persons with reduced physical, sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards.

Children must not play with, on, or around the appliance. Children must not clean the appliance or carry out general maintenance unless they are at least 8 years old and are being supervised. Keep children below the age of 8 years old at a safe distance from the appliance and power cable. Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transport. This appliance is not intended for operation with an external clock timer or a remote control.

Page 2 of the Constructa CD959652 user manual — Risk of injury! ■ The light emitted by LED lights is very
Page 2 · cliquer pour agrandir
Page 2

Risk of fire!

  • Grease deposits in the grease filter may

catch fire. Clean the grease filter at least every 2 months.

Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.

Never operate the appliance without the grease filter.

Risk of fire! ■ Grease deposits in the grease filter may

catch fire. Never work with naked flames close to the appliance (e.g. flambéing). Do not install the appliance near a heat- producing appliance for solid fuel (e.g. wood or coal) unless a closed, non- removable cover is available. There must be no flying sparks.

Risk of fire! ■Hot oil and fat can ignite very quickly.

Never leave hot fat or oil unattended. Never use water to put out burning oil or fat. Switch off the hotplate. Extinguish flames carefully using a lid, fire blanket or something similar.

  • Adequate incoming air must therefore

always be ensured.

Risk of fire! ■ When gas burners are in operation without

  • An incoming/exhaust air wall box alone

any cookware placed on them, they can build up a lot of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Only operate the gas burners with cookware on them.

will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.

Risk of fire! ■ Operating several gas burners at the

same time gives rise to a great deal of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Never operate two gas burners simultaneously on the highest flame for longer than 15 minutes. One large burner of more than 5 kW (wok) is equivalent to the power of two gas burners.

Risk of burns! The accessible parts become very hot when in operation. Never touch hot parts. Keep children at a safe distance.

In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.

Risk of injury!

  • Components inside the appliance may

have sharp edges. Wear protective gloves.

Risk of injury! ■ Items placed on the appliance may fall

down. Do not place any objects on the appliance.

Risk of injury! ■ The light emitted by LED lights is very

dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.

Page 3 of the Constructa CD959652 user manual — Exhaust air mode
Page 3 · cliquer pour agrandir
Page 3

Risk of electric shock!

Causes of damage

  • A defective appliance may cause electric

shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.

Risk of damage due to corrosion. Always switch on the appliance while cooking to avoid condensation. Condensate can produce corrosion damage.

Always replace faulty bulbs to prevent the remaining bulbs from overloading.

Risk of damage due to ingress of humidity into the electronic circuitry. Never clean operator controls with a wet cloth.

Risk of electric shock! ■ Incorrect repairs are dangerous. Repairs

may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.

Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the direction of the grain only. Do not use any stainless steel cleaners for operator controls.

Surface damage due to strong or abrasive cleaning agents. Never use strong and abrasive cleaning agents.

Risk of damage from returning condensate. Install the exhaust duct in such a way that it falls away from the appliance slightly (1° slope).

Risk of electric shock! ■ Do not use any high-pressure cleaners or

steam cleaners, which can result in an electric shock.

Environmental protection

Environmentally-friendly disposal

This appliance is labelled in accordance with European Directive 2012/19/EU concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.

Dispose of packaging in an environmentally-friendly manner.

Operating modes

Circulating-air mode

This appliance can be used in exhaust-air mode or circulating- air mode.

The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen.

Exhaust air mode

The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system.

  • To bind odours in circulating-air mode, you must install an

activated carbon filter. The different options for operating the appliance in circulating-air mode can be found in the brochure. Alternatively, ask your dealer. The required accessories are available from specialist retailers, from customer service or from the Online Shop.

  • For appliances with an additional internal filter, only the
  • Before conveying the exhaust air into a non-functioning

CleanAir recirculation module (see Accessories for circulating-air mode) can be used.

smoke or exhaust gas flue, obtain the consent of the heating engineer responsible.

  • If the exhaust air is conveyed through the outer wall, a

telescopic wall box should be used.

Page 4 of the Constructa CD959652 user manual — : Risk of injury!
Page 4 · cliquer pour agrandir
Page 4

Operation

These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance.

Intensive setting

You can use the intensive setting if there is a large build-up of odours and fumes/vapours.

Press the + button when the fan is at setting „.

The intensive setting ˜‚ is activated. Pressing the + button again activates the intensive setting ˜ƒ.

After approx. six minutes, the electronics automatically reduce the fan to a lower setting . If you want to end the intensive setting before the preset time expires, press the - button until the required fan setting is reached.

Control panel

Constructa CD959652 — Control panel diagram (page 4)
Fig. 1 · Control panel

YRO

Fan run-on time

Press the - button until – appears.

After approx. ten minutes, the fan switches off automatically.

Lighting

- Reduce the fan settings/fan run-on time/interval ventila- tion

The lighting can be switched on and off independently of the fan.

+ Increase the fan settings/intensive setting 1, 2

Press the A button.

Setting the fan

Press and hold the A button until the desired brightness is reached.

Switching on the appliance

  • Press the # button.

Audible signal

The fan starts at setting ƒ.

Switching on the acoustic signal

  • Press the + or - button to change the fan strength.

When the fan is switched off, press the # and + at the same time for approx. three seconds. An acknowledgement signal sounds.

Press the # button.

Switching off the acoustic signal

Repeat the "Switching on the acoustic signal" process.

Cleaning and maintenance

: Risk of burns!

Cleaning agents

The appliance will become hot during operation, especially near the bulbs. Allow the appliance to cool down before cleaning.

Observe the information in the table to ensure that the different surfaces are not damaged by using the wrong type of cleaning agent. Do not use

: Risk of electric shock!

  • harsh or abrasive cleaning agents,
  • cleaning agents with a high concentration of alcohol,

Penetrating moisture may result in an electric shock. Clean the appliance using a damp cloth only. Before cleaning, pull out the mains plug or switch off the circuit breaker in the fuse box.

  • hard scouring pads or sponges,
  • high-pressure cleaners or steam cleaners.

Wash new sponge cloths thoroughly before use.

: Risk of electric shock!

Follow all instructions and warnings included with the cleaning agents.

Do not use any high-pressure cleaners or steam cleaners, which can result in an electric shock.

: Risk of injury!

Components inside the appliance may have sharp edges. Wear protective gloves.

Show 5 more labels / short text on this page
Explanation · # Fan on/off · A Light on/off/dimming · Setting the brightness · Switching off
Page 5 of the Constructa CD959652 user manual — Installing the metal mesh grease filter
Page 5 · cliquer pour agrandir
Page 5

Removing metal grease filter

1. Open the lock and fold down the metal grease filter. While doing this, place the other hand under the metal grease filter.

Stainless steel Hot soapy water: Clean with a dish cloth and dry with a soft cloth.

Constructa CD959652 — Removing metal grease filter diagram (page 5)
Fig. 2 · Removing metal grease filter
2. Take the metal grease filter out of the holder.

Clean stainless steel surfaces in the direction of the grain only.

Special stainless steel cleaning prod- ucts are available from our after-sales service or from specialist retailers. Apply a very thin layer of the cleaning product with a soft cloth.

Painted surfaces Hot soapy water: Clean using a damp dish cloth and dry with a soft cloth/towel.

For edge extraction filters, pull the metal grease filter downwards. While doing this, place the other hand under the metal grease filter.

Do not use any stainless steel clean- ers.

Constructa CD959652 — Removing metal grease filter diagram (page 5)
Fig. 3 · Removing metal grease filter

Glass cleaner: Clean with a soft cloth.

Glass Glass cleaner: Clean with a soft cloth. Do not use a glass scraper.

Operating controls Hot soapy water: Clean using a damp dish cloth and dry with a soft cloth.

For additional filters, open the lock and fold down the metal grease filter. While doing this, place the other hand under the metal grease filter.

Risk of damage to the electronics from penetrating moisture. Never clean operator controls with a wet cloth.

Constructa CD959652 — Removing metal grease filter diagram (page 5)
Fig. 4 · Removing metal grease filter

Do not use any stainless steel clean- ers.

Cleaning the metal mesh grease filters

These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. : Risk of fire!

  • Grease can accumulate in the bottom of the metal grease

filter.

  • Hold the metal grease filter level, otherwise grease will drip

out.

Grease deposits in the grease filter may catch fire. Clean the grease filter at least every 2 months. Never operate the appliance without the grease filter.

3. Clean the metal grease filter.

Installing the metal mesh grease filter

1. Insert the metal mesh grease filter. While doing this, place the other hand under the metal mesh grease filter.
  • Do not use any aggressive, acidic or alkaline cleaning

agents.

  • When cleaning the metal mesh grease filters, also clean the
2. Fold the metal mesh grease filter upwards, locking it in place.

holder for the metal mesh grease filters in the appliance using a damp cloth.

  • The metal mesh grease filters can be cleaned in the

dishwasher or by hand.

In the dishwasher:

  • Do not clean heavily soiled metal mesh grease filters together

with utensils.

  • Place the metal mesh grease filters loosely in the dishwasher.

The metal mesh grease filters must not be wedged in.

By hand:

  • Soak the metal mesh grease filters in a hot soapy solution.
  • Clean the filters with a brush and then rinse them thoroughly.
  • Leave the metal mesh grease filters to drain.

Area Cleaning agents · Aluminium and plastic

Page 6 of the Constructa CD959652 user manual — LED lights
Page 6 · cliquer pour agrandir
Page 6

Trouble shooting

Malfunctions often have simple explanations. Please read the following notes before calling the after-sales service. : Risk of electric shock!

Replacing bulbs

These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. : Risk of electric shock!

Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.

When changing the bulbs, the bulb socket contacts are live. Before changing the bulb, unplug the appliance from the mains or switch off the circuit breaker in the fuse box.

Malfunction table

Problem Possible cause Solution

The appliance does not work

The plug is not plugged in.

Connect the appliance to the electricity supply

Power cut Check whether other kitchen appliances are working

1. Carefully remove the bulb ring using a suitable tool. 2. Pull out the bulb and replace it with a bulb of the same type.

Faulty fuse Check in the fuse box to make sure that the fuse for the appliance is OK

Constructa CD959652 — Malfunction table diagram (page 6)
Fig. 5 · Malfunction table

The lighting does not work.

The bulbs are faulty.

For information on chang- ing the bulbs, see the "Replacing Bulbs" section.

3. Insert the bulb cover.
4. Insert the mains plug or switch on the fuse again.

LED lights

Defective LED lights may be replaced by the manufacturer, their customer service or a qualified technician (electrician) only. : Risk of injury!

The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.

Replacing halogen bulbs ·

Page 7 of the Constructa CD959652 user manual — Accessories for circulating-air mode
Page 7 · cliquer pour agrandir
Page 7

After-sales service

Our after-sales service is there for you if your appliance needs to be repaired. We will always find the right solution in order to avoid unnecessary visits from a service technician.

Basic equipmentStarter set for circulating-air mode - wide
Constructa CD959652 — After-sales service diagram (page 7)
Fig. 6 · After-sales service

When calling us, please give the product number (E no.) and the production number (FD no.) so that we can provide you with the correct advice. The rating plate with these numbers can be found inside the appliance (remove the metal mesh grease filter to gain access).

You can make a note of the numbers of your appliance and the telephone number of the after-sales service in the space below to save time should it be required.

E no. FD no.

Please be aware that a visit by an after-sales engineer will be charged if a problem turns out to be the result of operator error, even during the warranty period.

Basic equipmentCleanAir recirculation module - narrow

Please find the contact data of all countries in the enclosed customer service list.

Rely on the professionalism of the manufacturer. You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances.

Constructa CD959652 — After-sales service diagram (page 7)
Fig. 7 · After-sales service

Accessories for circulating-air mode

(not included in the delivery)

  • Follow the installation instructions supplied with the

accessories.

  • For appliances with an additional internal filter, only the

CleanAir recirculation module can be used.

Basic equipmentStarter set for circulating-air mode - narrow
Constructa CD959652 — Accessories for circulating-air mode diagram (page 7)
Fig. 8 · Accessories for circulating-air mode
Basic equipmentCleanAir recirculation module - wide
Constructa CD959652 — Accessories for circulating-air mode diagram (page 7)
Fig. 9 · Accessories for circulating-air mode

1 CZ5105X5 channel width 260 mm

2 705431 channel width 260 mm

3 CZ5106X5 channel width 345 mm

4 705432 channel width 345 mm

5 CZ5280X0 channel width 260 mm

6 CZ5170X1 channel width 260 mm

7 CZ5286X0 channel width 345 mm

8 CZ5170X1 channel width 345 mm

Show 5 more labels / short text on this page
Throw-away filter · After-sales serviceO · Throw-away filter · Throw-away filter · Throw-away filter
Page 8 of the Constructa CD959652 user manual — : Important safety information
Page 8 · cliquer pour agrandir
Page 8

INSTALLATION INSTRUCTIONS

Constructa CD959652 — INSTALLATION INSTRUCTIONS diagram (page 8)
Fig. 10
Constructa CD959652 — INSTALLATION INSTRUCTIONS diagram (page 8)
Fig. 11
  • This appliance is fitted to the kitchen ceiling or a sturdy

suspended ceiling.

  • Follow the enclosed installation instructions for additional

special accessories (e.g. for circulating-air mode).

  • The surfaces of the appliance are sensitive. Avoid damaging

them during installation.

: Important safety information

Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location. The width of the extractor hood must correspond at least with the width of the hob. For the installation, observe the currently valid building regulations and the regulations of the local electricity and gas suppliers. When conveying the exhaust air, official and legal regulations (e.g. state building regulations) must be followed.

Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.

Installation instructions

Page 9 of the Constructa CD959652 user manual — Risk of injury! ■ The appliance is heavy. To move the
Page 9 · cliquer pour agrandir
Page 9

Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.

Risk of fire! Grease deposits in the grease filter may catch fire. The specified safety distances must be observed in order to prevent an accumulation of heat. Observe the specifications for your cooking appliance. If gas and electric hobs are operated together, the largest specified distance applies. Only one side of the appliance may be installed directly next to a high-sided unit or a wall. The distance between the appliance and wall or high-sided unit must be at least 50 mm.

  • Adequate incoming air must therefore

always be ensured.

Risk of injury!

  • An incoming/exhaust air wall box alone

will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.

  • Components inside the appliance may

have sharp edges. Wear protective gloves.

Risk of injury! ■The appliance may fall down if it has not

been properly fastened in place. All fastening components must be fixed firmly and securely.

Risk of injury! ■ The appliance is heavy. To move the

appliance, 2 people are required. Use only suitable tools and equipment.

Risk of electric shock! Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.

Risk of electric shock! It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an all-pole isolating switch must be present on the installation side with a contact gap of at least 3 mm. The fixed connection must only be installed by an electrician.

In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.

Page 10 of the Constructa CD959652 user manual — Preparing the ceiling
Page 10 · cliquer pour agrandir
Page 10

General information

Exhaust air mode : Risk of death!

Electrical connection : Risk of electric shock!

Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.

Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.

The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter.

Length of the cableapprox. 1.30 m

If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used.

This appliance complies with the EC interference suppression regulations. : Risk of electric shock!

Exhaust duct

It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an all-pole isolating switch must be present on the installation side with a contact gap of at least 3 mm. The fixed connection must only be installed by an electrician.

  • The device achieves its optimum performance by means of a

short, straight exhaust air pipe and as large a pipe diameter as possible.

  • As a result of long rough exhaust air pipes, many pipe bends

or pipe diameters that are smaller than 150 mm, the optimum extraction performance is not achieved and fan noise is increased.

  • The pipes or hoses for laying the exhaust air line must

consist of non-combustible material.

Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended.

Flat ducts The inner cross-section must correspond to the diameter of the round pipes.

dia. 150 mm ca. 177 cm2

dia. 120 mm ca. 113 cm2

  • Flat ducts should not have any sharp deflections.
  • Use sealing strips for deviating pipe diameters.

Preparing the ceiling

  • The ceiling must be flat, horizontal and have adequate load-

bearing capacity.

  • The depth of the bore holes must be the same length as the

screws. The wall plugs must have a secure grip.

  • The enclosed screws and wall plugs are suitable for solid

brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks).

  • The max. weight of the extractor hood is 50 kg .
Page 11 of the Constructa CD959652 user manual — Fitting the upper support frame
Page 11 · cliquer pour agrandir
Page 11

Installation

Fitting the upper support frame

Fitting the lower support frame

1. Before fitting, determine the total height of the support frame and mark the screw holes.

Fasten the upper and lower part of the support frame at the specified total height using 10 screws.

  • Ensure that the lower support frame is in the correct position.

The open side must be facing the hob control elements.

2. On the ceiling, mark the centre point of the appliance.
  • The support frame can be subsequently re-positioned by
3. Using the enclosed template, mark the positions for the screws on the ceiling.

loosening the securing screws.

Constructa CD959652 — Fitting the upper support frame diagram (page 11)
Fig. 12 · Fitting the upper support frame
Constructa CD959652 — Fitting the upper support frame diagram (page 11)
Fig. 13 · Fitting the upper support frame
4. Drill four 8 mm diameter holes to a depth of 80 mm for the fasteners and press in the wall plugs flush with the ceiling.
5. Fasten the upper part of the support frame to the ceiling with 4 screws.
Page 12 of the Constructa CD959652 user manual — Connecting the pipes
Page 12 · cliquer pour agrandir
Page 12

Fitting the appliance

Attaching the flue duct : Risk of injury!

1. Hook the appliance from below into the support frame.

From sharp edges during installation. Always wear protective gloves while installing the appliance.

2. Fasten the appliance to the support frame using 2 securing screws.
1. Separate the flue ducts. To do this, remove the adhesive tape.
Constructa CD959652 — Fitting the appliance diagram (page 12)
Fig. 14 · Fitting the appliance
2. Remove the protective foil from both sides.
3. Place both parts of the upper flue on the appliance and push together.
Constructa CD959652 — Fitting the appliance diagram (page 12)
Fig. 15 · Fitting the appliance
4. Push up the upper flue part and secure with 2 screws.
3. Hook in the retaining clip and screw tight.
Constructa CD959652 — Fitting the appliance diagram (page 12)
Fig. 16 · Fitting the appliance
Constructa CD959652 — Fitting the appliance diagram (page 12)
Fig. 17 · Fitting the appliance
5. Insert both lower parts of the flue and push together.

Connecting the pipes

Constructa CD959652 — Connecting the pipes diagram (page 12)
Fig. 18 · Connecting the pipes

Exhaust-air pipe Ø 150 mm (recommended size)

Attach the exhaust-air pipe directly to the air-pipe connector and seal.

Exhaust-air pipe Ø 120 mm

1. Attach the reducing connector directly to the air-pipe connector.
2. Attach the exhaust air pipe to the reducing connector.
3. Seal both joints appropriately.
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Constructa CD959652

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Constructa CD959652

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Constructa CD959652 manuel PDF

52 pages·3.2 MB·Hotte de cuisine·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…