Page 1 of the Constructa CD75131 user manual — Before using the first time
Page 1 · cliquer pour agrandir
Page 1

Operating modes

Before using the first time

How to operate the extractor hood

Exhaust-air mode q The ventilator fan draws the vapours

Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Do not flambé food directly under the extractor hood.

The most effective method of remo- ving vapours produced during cooking is to: q Switch the ventilator ON

produced during cooking into the extractor hood, where they pass through the grease filter and out into the open air. q The grease filter absorbs the grease

as soon as you begin cooking. q Switch the ventilator OFF

a few minutes after you have finished cooking.

contained in the vapours produced during cooking. q The kitchen is kept almost totally free

Operating controls on different models

Risk of grease filter catching fire due ! to flames. The hotplates must always be covered with a utensil. Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).

from grease and odours.

Constructa CD75131 — Operating modes diagram (page 1)
Fig. 1 · Operating modes

Circulating-air mode q An activated carbon filter must be fitted

for this operating mode (see Filters and maintenance).

Activated carbon filters can be purchased from specialist outlets (see Optional accessories on the last page). q The ventilator fan draws the vapours

Gas hobs / Gas cookers Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.

produced during cooking into the extractor hood, where they pass through the grease filter and the activa- ted carbon filter before the clean air is discharged back into the kitchen. q The grease filter absorbs the grease

contained in the vapours produced during cooking. q The activated carbon filter absorbs any

odorous substances.

Before using the first time

Important notes This extractor hood complies with all relevant safety regulations. Repairs should only be carried out by qualified specialists. If the connection cable of this appliance is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person in order to prevent a hazardous situation. Improperly executed repairs can give rise to significant hazards for the user. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance. The appliance should only be connected up to the mains and taken into use by a qualified specialist. Dispose of packaging materials properly (see Installation instructions). Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Light bulbs must always be fitted when the extractor hood is in use.

Show 7 more labels / short text on this page
Instructions for Use · Light · Intensive setting · Fan settings · Light · Intensive setting · Fan settings
Page 2 of the Constructa CD75131 user manual — Filters and maintenance
Page 2 · cliquer pour agrandir
Page 2

Filters and maintenance

Various types of grease filter can be used to absorb the grease contained in the vapours produced during cooking.

Removing and installing the grease filter Extractor hoods with a filter mat: 1. Rotate the handles on the left and right of the filter grille.

Extractor hoods with two filter cartridges: Warning: The halogen bulbs must be swit- ched off and cool. 1. Depress the detent on the grease filters in the direction of the arrow and fold down the grease filter slightly. Detach the grease filter by pulling it towards yourself.

Fleece grease filter The filter mat is made from material that is itself virtually non-inflammable. Caution: As it becomes more and more saturated with grease however, the filter becomes increasingly inflammable. The efficiency of the extractor hood can also be adversely affected. Important: Renewing the fleece filter at appropriate intervals prevents the possibility of it catching fire as a result of a build-up of heat, such as occurs when deep-fat frying or roasting is taking place. Renewing the fleece filter: q Under normal operating conditions

2. Press the retaining spring and remove the filter frame.

(1 to 2 hours per day), the fleece filter will require replacing after 8 to 10 weeks. Printed fleece filters must be renewed no later than when the colou- red printing has started to fade. q Use only original replacement filters.

In so doing you will ensure that safety regulations are upheld and the extractor hood performs as effectively as possi- ble. Disposing of the old fleece grease filter: Fleece grease filters do not contain any pollutants. They can be composted and disposed of as biodegradable waste.

2. Clean the grease filters. 3. Re-insert the clean grease filters.
3. Remove the wire grille and replace the filter mat.

Metal grease filter The filter mat is made of non-combustible metal. Caution: As it becomes more and more saturated with grease, the filter also becomes increasingly inflammable. The efficiency of the extractor hood can also be adversely affected. Important: Clean the metal grease filter at regular intervals. Cleaning the metal filter: Under normal operating conditions (1 to 2 hours per day), the metal grease filter will require cleaning after 8 to 10 weeks. q The filter can be cleaned in a

4. Install the filter frame in reverse sequence. Re-attach the retaining spring. The left and right sides of the filter frame must lock into position!

dishwasher. This can however cause slight discoloration. Important: Metal filters that are heavily saturated with grease should not be cleaned at the same time as any crockery, etc. q If the filter mat is going to be cleaned by

hand, soak it first of all in a hot deter- gent solution for several hours. Clean the filter with a brush, rinse it off thoroughly and allow it to drip dry. q Use only original replacement filters.

In so doing you will be ensuring that the extractor hood performs as effectively as possible.

Page 3 of the Constructa CD75131 user manual — Activated carbon filter
Page 3 · cliquer pour agrandir
Page 3

Activated carbon filter

Removing and installing the activa- ted carbon filter Extractor hoods with a filter mat: 1. Remove the filter; see grease filter. q The wire grille is no longer required

Extractor hoods with two filter cartridges: 1. Remove the filter cartridge. q See grease filter. 2. Insert the screw through the wing nut and the sleeve and screw in the middle screw in the false bottom (required only during the initial installation). Screw, sleeve and wing nut are enclosed with the activated carbon filter. 3. Using a screwdriver, press in the two lugs on the false bottom. If a spacer rail has been installed, it must be removed.

Constructa CD75131 — Activated carbon filter diagram (page 3)
Fig. 2 · Activated carbon filter

when an activated carbon filter is installed.

Constructa CD75131 — Activated carbon filter diagram (page 3)
Fig. 3 · Activated carbon filter
Constructa CD75131 — Activated carbon filter diagram (page 3)
Fig. 4 · Activated carbon filter
6. Re-insert the two filter cartridges. Removing the activated carbon filter: q The activated carbon filter is removed in
2. Place the activated carbon filter on the filter mat and clamp it in.

reverse sequence. Changing the activated carbon filter: If used normally (1 to 2 hours daily), the activated carbon filter should be changed approx. once a year. Activated carbon filters can be purchased from SPECIALIST OUTLETS (see optional accessories on the last page). Use original filters only. This will ensure optimum performance. Disposing of the old activated carbon filter: Activated carbon filters do not contain any pollutants. They can be disposed of e.g. as residual waste.

4. Tape over the activated carbon filter with the enclosed sealing strip.
3. Install the filter frame. q See grease filter.
5. Insert the activated carbon filter at the rear, fold up and lock in the middle with the wing nut. If the spacer rail has been removed, it must be re-installed.
Page 4 of the Constructa CD75131 user manual — Cleaning and care
Page 4 · cliquer pour agrandir
Page 4

Cleaning and care

Switch off the extractor hood and isola- te by pulling out the mains plug or swit- ching off the disconnector on the instal- lation side.

Changing the bulbs 1. Switch off the extractor hood and isolate by pulling out the mains plug or swit- ching off the disconnector on the instal- lation side. 2. Remove the filter frame. q See grease filter. 3. Replace the bulb (standard filament bulb, max 40 W, E14 bulb holder).

Halogen bulbs: 1. Switch off the extractor hood and isolate by pulling out the mains plug or swit- ching off the disconnector on the instal- lation side. When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off there is still a risk of burns. 2. Remove the bulb ring with a screwdriver or similar tool. 3. Replace the halogen light bulb (conventional halogen bulb, 12 Volt, max. 20 Watt, G4 cap). Caution: Refer to for plug-in lampholder. Take hold of the bulb with a clean cloth.

q At the same time as you renew the

grease filter (see Filters and maintenance), clean off any grease from all accessible parts of the housing. This significantly reduces the fire hazard and ensures that the extractor hood performs as effectively as possible. q Clean the extractor hood with a hot

Constructa CD75131 — Cleaning and care diagram (page 4)
Fig. 5 · Cleaning and care

detergent solution or a mild window cleaning agent. q If the hood is extremely dirty (older

stains), use a liquid window cleaner. q Do not scratch off dried-on dirt, but

wipe off with a damp cloth. q Do not use scouring agents. Warning: Clean the control buttons with a mild detergent solution and a soft, damp cloth only. Painted, aluminium and plastic surfaces: q Do not use scouring agents or abrasive

4. Attach the filter frame. q See grease filter.

sponges. q Do not use dry cloths. q Do not use corrosive, acidic or alkaline

cleaning agents. q NoteDo not use alcohol (spirit) on

plastic parts, otherwise the surface may become matt in appearance. q Caution! Ensure that the kitchen is ade-

quately ventilated. Avoid naked flames.

4. Re-insert the bulb ring. 5. Plug the appliance into the mains or switch it on at the fuse box. Note: I f the light does not function, check that the bulbs have been inserted correctly.
Page 5 of the Constructa CD75131 user manual — If you encounter a problem
Page 5 · cliquer pour agrandir
Page 5

Installation Instructions:

If you encounter a problem

Important information

Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, ren- der it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 650 mm. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.

If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives).

Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions sup- plied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm.

When you call, please quote the following:

E-Nr. FD

Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached.

Constructa CD75131 — If you encounter a problem diagram (page 5)
Fig. 6 · If you encounter a problem
Page 6 of the Constructa CD75131 user manual — Prior to installation
Page 6 · cliquer pour agrandir
Page 6

Prior to installation

Pipe connection Extractor hoods with 120 mm Ø air outlet: 100 mm Ø extraction pipe q Insert the reducing connector (see optio-

Constructa CD75131 — Prior to installation diagram (page 6)
Fig. 7 · Prior to installation

nal accessories on the last page) into the air-pipe connector and then attach the exhaust-air pipe. 120 mm Ø extraction pipe q Attach the exhaust-air pipe directly to

the air-pipe connector.

The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if the combustion air can be replenished by being able to flow through non-closeable openings such as in doors, windows, wall ventilation boxes, or by alternative technical measures such as reciprocally shutting the other device off, etc. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. All legal requirements concerning the discharge of exhaust air must be observed. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. The extractor hood should be fitted with a one-way flap for exhaust-air mode if there is not already one installed in the exhaust-air pipe or wall box. If a one-way flap is not enclosed with the appliance, purchase one from a specialist outlet (see optional acces- sories on the last page).

Attaching the one-way flap q Insert the two lugs on the one-way flap

Extractor hoods with 150 mm Ø air outlet: 150 mm l extraction pipe q Screw the reducing connector (see

into the holes on the air-pipe connector or air outlet and lock into position. Before installing the one-way flap, ensu- re that the lettering or stamp is on the out- side.

optional accessories on the last page) onto the air outlet. q Attach the extraction pipe to the redu-

cing connector. 150 mm l extraction pipe q Attach the exhaust-air pipe directly to

Optimum performance of the extractor hood: q Short, smooth extraction pipe. q As few pipe bends as possible. q Largest possible pipe diameter (prefera-

the air outlet.. If a one-way flap has been fitted, con- duct a performance test. Extractor hoods with rectangular air outlet: q Screw the enclo-

bly 150 mm ø) and large pipe bends. q Round pipes:

We recommend for single-motor model, inner diameter of at least 120 mm for double-motor model. inner diameter of at least 150 mm q Flat ducts must have an inner cross-

sed air-pipe connector over the air outlet.

section equivalent to round pipes which have an inner diameter of 120/150 mm. 120 mm l approx. 113 cm2 150 mm l approx. 177 cm2

q If pipe diameters differuse sealing

strip. q Ensure an adequate air supply for

exhaust-air mode.

q The air cleaned by an additional activa-

ted carbon filter is conveyed back into the room. q In recirculated air mode the exhaust ope-

ning must be protected by a grille (see optional accessories on the last page) in order to prevent a mechanical or electri- cal hazard.

Exhaust-air mode · Recirculated air mode

Page 7 of the Constructa CD75131 user manual — Electrical connection Installation
Page 7 · cliquer pour agrandir
Page 7

Electrical connection Installation

The extractor hood must be connected to a correctly installed earthed socket only. Attach the earthed socket as close to the appliance as possible and in an accessible position. If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be provided on the installation side. Dis- connectors are switches with a contact opening of more than 3 mm and all-pole disconnection. LS switches and contactors are regarded as disconnectors. The appliance must be isolated before repairs are carried out. Repairs may be carried out by authorised technicians only. If the connection cable of this appliance is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person in order to prevent a hazardous situation. Improper repairs may put the user at considerable risk. Length of connection cable: 1.20 m. Electrical specifications: The electrical specifications can be found on the rating plate inside the appliance when the filter frame has been removed. Do not place hand in the air outlet.

The extractor hood is particularly suitable for installation in a flue or chimney. To ensure optimum extraction perfor- mance (especially important for kitchen island solu- tions): q Install the extractor hood as high as

Extractor hood with slide control, 53 cm wide, 1 and 2-motor:

Constructa CD75131 — Electrical connection Installation diagram (page 7)
Fig. 8 · Electrical connection Installation

possible within the structure q The structure must cover the entire

cooking area.

The following cutouts must be made for the installation depending on the model: Extractor hood with rocker switch, 53 cm wide, 1-motor:

Constructa CD75131 — Electrical connection Installation diagram (page 7)
Fig. 9 · Electrical connection Installation
Constructa CD75131 — Electrical connection Installation diagram (page 7)
Fig. 10 · Electrical connection Installation

This appliance complies with the EC radio interference suppression regulations.

Page 8 of the Constructa CD75131 user manual — Installation
Page 8 · cliquer pour agrandir
Page 8

Installation

Removal

Extractor hood with slide control, 73 cm wide, 1 and 2-motor

Constructa CD75131 — Installation diagram (page 8)
Fig. 11 · Installation
1. Remove the filter grille (see operating instructions). 2. Connect the power. 3. Press the extractor hood up into the installation opening until the installation aid locks into position at the front and rear. 4. Screw in the extractor hood.
1. Loosen the screws. 2. Hold the underside of the extractor hood, Hold the underside of the extractor hood.
Constructa CD75131 — Installation diagram (page 8)
Fig. 12 · Installation
Constructa CD75131 — Installation diagram (page 8)
Fig. 13 · Installation
Constructa CD75131 — Installation diagram (page 8)
Fig. 14 · Installation
3. Lower the extractor hood and remove.
5. Insert and secure the filter grille (see operating instructions).

Design changes with respect to technical development shall remain withheld

Installation spring

Poser une question sur : Constructa CD75131

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Constructa CD75131

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Constructa CD75131 manuel PDF

60 pages·6.9 MB·Hotte de cuisine·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …