Ú Table of contents[en]I nstructi ons for i nstal l ati on and use
INSTALLATION INSTRUCTIONS............................................. 24
Intended use 16 Important safety information 17 Environmental protection 19 Operating modes 19 Operating the appliance 20 Cleaning and maintenance 21 Trouble shooting 23 Customer service 23
Produktinfo Additional information on products, accessories, replacement parts and services can be found at www.constructa.de and in the online shop www.constructa-eshop.com
Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location. This appliance is intended for domestic use and the household environment only. The appliance is not intended for use outside. Do not leave the appliance unattended during operation. The manufacturer is not liable for damage which is caused by improper use or incorrect operation. This appliance is intended for use up to a maximum height of 2000 metres above sea level.
This appliance may be used by children over the age of 8 years old and by persons with reduced physical, sensory or mental capacity or by persons with a lack of experience or knowledge if they are supervised by someone who is responsible for their safety, or have been instructed in how to use the appliance safely and have understood the risks involved in not using it properly. Children must not play with the appliance.Cleaning and user maintenance must not be performed by children unless they are over 15 years of age and are supervised. Keep children below the age of 8 years old at a safe distance from the appliance and power cable. Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transport. This appliance is not intended for operation with an external clock timer or a remote control.

In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
catch fire. Regularly clean the grease filter. Never operate the appliance without a grease filter.
catch fire. Never work with naked flames close to the appliance (e.g. flambéing). Do not install the appliance near a heat- producing appliance for solid fuel (e.g. wood or coal) unless a closed, non- removable cover is available. There must be no flying sparks.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney). In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.
Risk of fire! ■Hot oil and fat can ignite very quickly.
Never leave hot fat or oil unattended. Never use water to put out burning oil or fat. Switch off the hotplate. Extinguish flames carefully using a lid, fire blanket or something similar.
any cookware placed on them, they can build up a lot of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Only operate the gas burners with cookware on them.
always be ensured.
same time gives rise to a great deal of heat. A ventilation appliance installed above the cooker may become damaged or catch fire. Never operate two gas burners simultaneously on the highest flame for longer than 15 minutes. One large burner of more than 5 kW (wok) is equivalent to the power of two gas burners.
will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.
when in operation. Never touch hot parts. Keep children at a safe distance.
operation. Allow the appliance to cool down before cleaning.

Causes of damage
have sharp edges. Wear protective gloves.
Risk of damage due to corrosion. Always switch on the appliance while cooking to avoid condensation. Condensate can produce corrosion damage.
down. Do not place any objects on the appliance.
Always replace faulty bulbs to prevent the remaining bulbs from overloading.
Risk of damage due to ingress of humidity into the electronic circuitry. Never clean operator controls with a wet cloth.
dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.
Surface damage due to incorrect cleaning. Clean stainless steel surfaces in the direction of the grain only. Do not use any stainless steel cleaners for operator controls.
Surface damage due to strong or abrasive cleaning agents. Never use strong and abrasive cleaning agents.
Risk of damage from returning condensate. Install the exhaust duct in such a way that it falls away from the appliance slightly (1° slope).
shock. Never switch on a defective appliance. Unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
Risk of damage as a result of incorrect loading of design elements. Do not pull design elements.Do not place objects on the design elements or hang objects from them.
There is a risk of surface damage if you do not peel off the protective film.Remove the protective film from all parts of the appliance before using the appliance for the first time.
may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
steam cleaners, which can result in an electric shock.
electric shock. Clean the appliance using a damp cloth only. Before cleaning, pull out the mains plug or switch off the circuit breaker in the fuse box.

Your new appliance is particularly energy-efficient. Here you can find tips on how to save even more energy when using the appliance, and how to dispose of your appliance properly.
Dispose of packaging in an environmentally-friendly manner.
This appliance is labelled in accordance with European Directive 2012/19/EU concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.
to enable the extractor hood to work efficiently and with a low level of operating noise.
during cooking. Only use intensive mode when required. The lower the fan speed, the less energy is consumed.
fan speed in good time. If the cooking steam has already spread around the kitchen, the extractor hood will need to be operated for longer.
order to increase the effectiveness of the ventilation system and to prevent the risk of fire.
Circulating-air mode
The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system.
The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen.
smoke or exhaust gas flue, obtain the consent of the heating engineer responsible.
telescopic wall box should be used.

These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance.
Intensive setting
You can use the intensive setting if there is a large build-up of odours and fumes/vapours.
Touch the g symbol. ˜ƒ will light up on the display.
A / @ Fan settings
Touch the g symbol again to switch back to intensive mode ˜‚.
g Intensive mode 1/2
z Metal grease filter/ activated charcoal filters
Touch the g symbol to stop intensive mode.
Touch the + symbol. + will light up on the display panel.
The fan will run at fan setting 1.
‚ - „ Fan settings
The fan will switch off automatically after approximately 10 minutes.
˜‚ / ˜ƒ Intensive mode 1/2
/ Duration of fan run-on
| Metal grease filter saturation indicator
Touch the + symbol.
{ Activated charcoal filter saturation indicator
This immediately stops the fan run-on.
Intermittent ventilation
With intermittent ventilation, the fan automatically switches to the lowest setting for 5 minutes every hour.
Touch the # symbol.
The fan will start at fan setting 2.
Choosing the fan setting
Touch the ' symbol. ' will light up on the display panel.
Touch the @ or A symbol to select a different fan setting.
Intermittent ventilation is activated.
The fan setting that is selected will be shown on the display panel.
Touch the ' symbol.
This immediately stops the intermittent ventilation. The fan will run at fan setting 2.
Touch the # symbol.

Audible signal
When the metal grease filters or the activated charcoal filter become saturated, the relevant indicator flashes after the appliance is switched off:
With the fan switched off, touch and hold the # and ' symbols at the same time for approximately 3 seconds. A signal will sound as an acknowledgement.
When the signal tone is activated, ‚ will be lit.
If you have not yet done so, the metal grease filters should now be cleaned or the activated charcoal filter replaced.
With the fan switched off, touch and hold the # and ' symbols at the same time for approximately 3 seconds. A signal will sound as an acknowledgement.
When the signal tone is deactivated, ‹ will be lit.
The saturation indicators can be reset while they are flashing. Touch the z symbol to do this.
The lighting can be switched on and off independently of the fan.
Switching over the display for air circulation mode
Touch the N symbol.
For air recirculation mode, the electronic controller must be switched over accordingly:
Press and hold the N symbol until the required brightness is reached.
"2" lights up for air recirculation mode (filters that cannot be regenerated).
until "3" lights up for air recirculation mode (filters that can be regenerated).
until the electronic controller has switched back to air extraction mode (indicator 1 ).
: Risk of burns!
The appliance becomes hot during operation. Allow the appliance to cool down before cleaning.
Stainless steel Hot soapy water: Clean with a dish cloth and then dry with a soft cloth.
the appliance using a damp cloth only. Before cleaning, pull out the mains plug or switch off the circuit breaker in the fuse box.
Clean stainless steel surfaces in the direction of the grain only.
Risk of electric shock! ■Do not use any high-pressure cleaners or steam cleaners,
Special stainless steel cleaning prod- ucts are available from our after-sales service or from specialist retailers.Apply a very thin layer of the cleaning product with a soft cloth.
Components inside the appliance may have sharp edges. Wear protective gloves.
Painted surfaces Hot soapy water: Clean using a damp dish cloth and then dry with a soft cloth.
There is a risk of surface damage if you do not peel off the protective film.Remove the protective film from all parts of the appliance before using the appliance for the first time.
Do not use stainless steel cleaner.
Hot soapy water: Clean with a soft cloth.
To ensure that the different surfaces are not damaged by using the wrong cleaning product, follow the instructions in the table. Do not use any of the following:
Glass Glass cleaner: Clean with a soft cloth. Do not use a glass scraper.
Controls Hot soapy water: Clean using a damp dish cloth and then dry with a soft cloth.
Risk of electric shock caused by pene- trating moisture.
Risk of damage to the electronics caused by penetrating moisture. Never clean controls with a wet cloth.
Do not use stainless steel cleaner.

Installing the metal mesh grease filter : Risk of injury!
Components inside the appliance may have sharp edges. Wear protective gloves.

dripping out.
These instructions apply to several appliance variants. It is possible that individual features are described which do not apply to your appliance. : Risk of fire!
Fatty deposits in the grease filter may catch fire. Regularly clean the grease filter. Never operate the appliance without a grease filter.
grease filter holder in the appliance using a damp cloth.
by hand.
By hand:
material.
In the dishwasher:
cookware.
plenty of space around them. Do not trap the metal grease filters.

Malfunctions often have simple explanations. Please read the following notes before calling the after-sales service. : Risk of electric shock!
Defective LED lights may be replaced by the manufacturer, their customer service or a qualified technician (electrician) only. : Risk of injury!
Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after-sales service.
The light emitted by LED lights is very dazzling, and can damage the eyes (risk group 1). Do not look directly into the switched on LED lights for longer than 100 seconds.
Problem Possible cause Solution
The appliance does not work
The plug is not plugged in.
Connect the appliance to the electricity supply
Power cut Check whether other kitchen appliances are working
Faulty fuse Check in the fuse box to make sure that the fuse for the appliance is OK
The lighting does not work.
The LED lights are defective.
Call the after-sales ser- vice.
The button illu- mination does not work.
The control unit is faulty.
Call the aftersales ser- vice.
When calling us, please give the product number (E no.) and the production number (FD no.) so that we can provide you with the correct advice. The rating plate with these numbers can be found inside the appliance (remove the metal mesh grease filter to gain access).
(not included in the scope of delivery)
You can make a note of the numbers of your appliance and the telephone number of the after-sales service in the space below to save time should it be required.
Accessory - narrow 260 mm Order number
E no. FD no.
Starter set for air recirculation mode CZ5101X5
Easy-change filter for CleanAir recirculation module (cannot be regenerated)
Please be aware that a visit by an after-sales engineer will be charged if a problem turns out to be the result of operator error, even during the warranty period.
Accessory - wide 345 mm Order number
Please find the contact data of all countries in the enclosed customer service list.
Starter set for air recirculation mode CZ5102X5
Rely on the professionalism of the manufacturer. You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances.
Easy-change filter for CleanAir recirculation module (cannot be regenerated)



template.
special accessories (e.g. for circulating-air mode).
them during installation.
Read these instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual and installation instructions for future use or for subsequent owners. Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transport. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.
The surfaces of the appliance are easily damaged. Avoid damaging them during installation. The width of the extractor hood must correspond at least with the width of the hob. For the installation, observe the currently valid building regulations and the regulations of the local electricity and gas suppliers.
Installation instructions

In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space.
catch fire. The specified safety clearances must be complied with in order to prevent a build-up of heat. Refer to the information provided for your cooker. If gas and electric hobs are being operated together, the largest specified clearance applies.
always be ensured.
catch fire. Never work with naked flames close to the appliance (e.g. flambéing). Do not install the appliance near a heat- producing appliance for solid fuel (e.g. wood or coal) unless a closed, non- removable cover is available. There must be no flying sparks. When conveying the exhaust air, official and legal regulations (e.g. state building regulations) must be followed.
will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa (0.04 mbar). This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means.
Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.
In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode.
have sharp edges. Wear protective gloves.
Room air-dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney).
Risk of injury! ■The appliance may fall down if it has not
been properly fastened in place. All fastening components must be fixed firmly and securely.
appliance, 2 people are required. Use only suitable tools and equipment.
assembly are dangerous and may lead to malfunctions. Do not make any changes to the electrical or mechanical assembly.

The permanent electrical installation must only be wired by a professional electrician. We recommend installing a residual- current circuit breaker (RCCB) in the appliance's power supply circuit.
have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.
Risk of electric shock! Incorrect repairs are dangerous. Repairs may only be carried out and damaged power cables replaced by one of our trained after-sales technicians. If the appliance is defective, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Contact the after- sales service.
the appliance from the electricity supply. The appliance must only be connected to a protective contact socket that has been correctly installed. The mains plug of the mains power cable must be easily accessible after installation of the appliance. If this is not possible, an all-pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations.
Exhaust air mode : Risk of death!
Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible.
screws. The wall plugs must have a secure grip.
brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks).
If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used.
Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation.
The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter.
short, straight exhaust air pipe and as large a pipe diameter as possible.
or pipe diameters that are smaller than 150 mm, the optimum extraction performance is not achieved and fan noise is increased.
This appliance complies with the EC interference suppression regulations. : Risk of electric shock!
consist of non-combustible material.
Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended.
It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket that has been correctly installed. The mains plug of the mains power cable must be easily accessible after installation of the appliance. If this is not possible, an all-pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations. The permanent electrical installation must only be wired by a professional electrician. We recommend installing a residual- current circuit breaker (RCCB) in the appliance's power supply circuit.
Flat ducts The inner cross-section must correspond to the diameter of the round pipes.
dia. 150 mm ca. 177 cm2
dia. 120 mm ca. 113 cm2

Installation
Ensure that there are no electrical wires, gas pipes or water pipes in the area where holes are to be drilled.





Connecting the pipes
Exhaust-air pipe Ø 150 mm (recommended size)
Attach the exhaust-air pipe directly to the air-pipe connector and seal.
Exhaust-air pipe Ø 120 mm

Components inside the appliance may have sharp edges. Wear protective gloves.
flue duct to protect the surface.


Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.