FR
Constructa logo
Notice d'utilisation officielle

Constructa CD22130

56 pages·8.6 MB·Hotte de cuisine·PDF·ENJA
Constructa CD22130
Table des matières 14 sections Instructions for Use · Appliance description Operating modes · Before using for the first time · Operating modes · … AfficherMasquer
Page 1 of the Constructa CD22130 user manual — Before using for the first time
Page 1 · cliquer pour agrandir
Page 1

Instructions for Use

Appliance description Operating modes

Before using for the first time

Constructa CD22130 — Instructions for Use diagram (page 1)
Fig. 1 · Instructions for Use

q Before using your appliance for the first

time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance. q Please retain the operating and installati-

as a special accessory from your aut- horized dealer.

on instructions for a subsequent owner. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Do not flambé food directly under the extractor hood. Risk of grease filter catching fire due to flames. The hotplates must always be covered with a utensil. Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instruc- tions).

can be found at the end of these opera- ting instructions.

chen vapours, which are purified in the grease filter and activated carbon filter and then conveyed back into the kit- chen.

Operating modes

q The grease filter absorbs the grease par-

ticles in the kitchen vapours.

Exhaust-air mode:

q The activated carbon filter binds the

odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours.

q The extractor-hood fan extracts the kit-

chen vapours and conveys them through the grease filter into the atmosphere. q The grease filter absorbs the solid par-

Gas hobs / Gas cookers Do not use all the gas hotplates simulta- neously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwi- se there is a risk of burns if the housing sur- faces are touched or a risk of damage to the extractor hood.

ticles in the kitchen vapours. q The kitchen is kept almost free of grease

and odours.

If the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply, which the heater requires for com- bustion.

Before using for the first time

If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.

versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. q This extractor hood complies with all

Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar).

relevant safety regulations. q Repairs should be carried out by quali-

This can be achieved if the combustion air is able to flow through non-lockable open- ings, e.g. in doors, windows and in con- junction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.

fied technicians only. Improper repairs may put the user at considerable risk.

Do not use the appliance if damaged. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance. If the connecting cable for this applian- ce is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. The appliance may be connected to the mains by a qualified technician only. Dispose of packaging materials properly (see Installation instructions). This extractor hood is designed for domestic use only. Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Never operate the extractor hood with- out a grease filter.

If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.

Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.

Page 2 of the Constructa CD22130 user manual — Using the extractor hood
Page 2 · cliquer pour agrandir
Page 2

Using the extractor hood

Filters and maintenance

Kitchen vapour is most effectively eliminated by:

q Switching on the extractor hood

Different grease filters can be used to absorb the grease particles in kitchen vapour.

when you start cooking. q Switching off the extractor hood a

few minutes after you have finished cooking.

Fleece grease filter: The filter mat consists of highly flameresis- tant material.

Switching on the fan: q Open the door. q Select fan speed. Switching off the fan: q Close the door. q When the door is opened out again the

fan operates at its last speed setting.

Switching on the fan: q Open the door. q Select fan speed. q Push-and-lock switch for full power.

Replacing the fleece grease filterq During normal operation (daily 1 to 2

hours) the fleece grease filter must be replaced every 8 to 10 weeks. q Replace printed fleece grease filters at

Switching off the fan: The extractor hood can be switched off in various ways.

the latest when the coloured print dissol- ves. Only use original filters. q These comply with the safety regulations

Switching off 1: q Switch to 0 – switch fan to OFF.

and ensure optimum function.

Switching off 2: q Close the door (switch remains ON). q To switch ON again just open the door.

Disposal if the old fleece grease filter: q Fleece grease filters do not contain any

Light Fan speed Full power

The extractor hood operates at its last fan speed setting.

harmful substances. They can be dispo- sed of as bio-degradable waste.

1 2 3 4

Lighting: The light can be used at any time even when the fan is switched OFF or the door is closed.

Metal grease filters: The filter mats consist of non-flammable metal.

Cleaning the metal grease filtersq During normal operation (daily 1 to 2

hours) metal grease filters must be repla- ced every 8 to 10 weeks. q The metal grease filter can be cleaned in

the dishwasher. Slight discoloration may occur. Important: q Do not clean heavily saturated metal

grease filters together with kitchen uten- sils. q If cleaning by hand, soak the filter mats

in a hot soapy solution for several hours. Then brush them off, rinse thoroughly and leave to dry. q Only use original filters.

These ensure optimum function.

Light Fan speed · Light Fan speed · Light Fan speed

Page 3 of the Constructa CD22130 user manual — Filters and maintenance
Page 3 · cliquer pour agrandir
Page 3

Filters and maintenance

Removal the grease filter: 1. Open door as far as it will go. 2. Push the filter screen up slightly, lift it towards you over the brackets and take it out downwards..

5. Insert activated carbon filter in the lower left corner of the housing. Shift it until both hooks slot into the holes and then secure in place with the wing nut.
3. Remove the wire grid.

Check that the filter screen is securely located behind the retaining brackets on both sides.

Activated carbon filter: For binding odours in recirculating air mode. Fitting and removal: 1. Open door to the stop. 2. Push the filter screen up slightly, lift it towards you over the brackets and take it out downwards.

6. Position the filter screen against the housing and push upwards. Push in the lower edge over the brackets and lower the screen into place.
4. Fleece grease filter Remove saturated filter mat, clean the filter grid and insert new filter mat.

Metal grease filter Remove saturated filter mats, clean mats and grid. Refit the cle- aned filter mats, making sure that there is no gap in the middle.

Check that the filter screen is securely located behind the retaining brackets on both sides. Removal is in the reverse sequence.

3. Insert the screw through the wing nut and bushing and screw into the housing (only necessary upon initial fitting. The screw and wing nut are included with activated carbon filter.
Replacing the activated carbon filterq During normal operation (daily 1 to 2

hours) the activated carbon filter must be replaced approximately 1x year. q The activated carbon filter can be

purchased FROM YOUR DEALER (see Optional accessories). Only use original filters. q These ensure optimum function.

Fitting grease filters: 1. Clamp in the filter mats with the wire grid.

Disposal of the old activated carbon filter: q Activated carbon filters do not contain

any harmful substances. They can be disposed of as residual waste.

4. Using a screwdriver or similar, press the two lugs in the housing through to the back (only necessary upon initial fitting).
2. Position the filter screen against the housing and push upwards. Push in the lower edge over the lugs and lower the grid into place.
Page 4 of the Constructa CD22130 user manual — Faults
Page 4 · cliquer pour agrandir
Page 4

Installation instructions

Changing the bulbs Cleaning and care

Important information

Old appliances are not worthless rub- bish. Valuable raw materials can be reclai- med by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of dis- posal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. The minimum distance between the hob and the lower edge of the extractor hood is 650 mm. The extractor hood must not be instal- led over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the coo- ker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.

Isolate the extractor hood by pulling out the mains plug or switching off the fuse.

1. Switch off the extractor hood and deenergize by pulling out the mains plug or switching off the fuse. 2. Press the edges of the lamp cover together where indicated and lift it out towards you.

q When cleaning the grease filters, remove

grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum effi- ciency.

q Clean the extractor hood with a hot soap

solution or a mild window cleaner.

q Do not scrape off dried-on dirt but wipe

off with a damp cloth.

q Do not use scouring agents or abrasive

sponges.

q NoteDo not use alcohol (spirit) on pla-

stic surfaces, as dull marks may appear.

3. Replace the bulb (standard filament bulb, max 40 W, E14 bulb holder). 4. Refit lamp cover. 5. Reinsert mains plug or switch on the fuse.
Aluminium and plastic surfacesq Use a soft, non-linting window cloth or

micro-fibre cloth.

q Do not use dry cloths.

Faults

q Use a mild window cleaning agent.

q Do not use aggressive, acidic or caustic

If you should have any questions or there are any faults, call customer service (see list of customer service units).

Additional information concerning gas cookers:

cleaners.

q Do not use abrasive agents.

When installing gas hotplates, comply with the relevant national statutory regulati- ons (e.g. in Germany: Technische Regeln Gasinstallation TRGI).

Please give the following details when you call:

Product no. (E-Nr.)

Always comply with the currently valid regulations and installation instructions sup- plied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm.

Serial no. (FD)

Enter these numbers in the spaces above. You will find the numbers on the rating plate inside the extractor hood after removing the filter screen.

Page 5 of the Constructa CD22130 user manual — Before installation
Page 5 · cliquer pour agrandir
Page 5

Before installation

Optimum efficiency of the extractor hood: q Short, smooth exhaust pipe.

Constructa CD22130 — Before installation diagram (page 5)
Fig. 2 · Before installation

q As few bends as possible.

q Pipe diameter as large as possible (ideal-

ly 150 mm dia.) and wide pipe bends.

If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise.

For exhaust air mode always cut out the protective grid in the air connector.

The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open.

Short exhaust air pipe: inside diameter min. 120 mm, Longer exhaust air pipe: inside diameter min. 150 mm.

Constructa CD22130 — Before installation diagram (page 5)
Fig. 3 · Before installation

Exhaust air must not be discharged via a smoke or exhaust gas flue which is already in use or via a shaft which is used for venti- lating rooms in which fireplaces are located.

q Flat ducts must have an inside

cross-section equivalent to that of the round pipes. There should be no sharp bends. ø 120 mm dia. approx. 113 cm2

Discharge exhaust air in accordance with official and statutory regulations (e.g. national building regulations).

Discharge of air into smoke or exhaust air flues which are not in use requires the con- sent of a heating engineer.

ø 150 mm dia. approx. 177 cm2

q If pipe diameters differ, insert sealing

strip.

With exhaust mode, a backwash valve should be installed unless it is already in - corporated in the exhaust pipe or wall box. If a backwash valve is not included with your appliance, your dealer can supply you with one (see accessories).

If the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply which the heater requires for combustion.

q Ensure that there is an adequate air sup-

ply for exhaust air mode.

Constructa CD22130 — Before installation diagram (page 5)
Fig. 4 · Before installation

Installation backwash valve: Insert the backwash valve in the mounting openings on the air connector.

Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar).

This can be achieved if the combustion air is able to flow through non-lockable open- ings, e.g. in doors, windows and in con- junction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking. If the air intake is inadequate, there is a risk of poisoning from combustion gases, which are drawn back into the room.

If the exhaust air is being routed through the outside wall, a telescopic wall box should be used.

An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will no be exceeded.

Connecting to Ø100 mm exhaustair duct Attach the reducing adapter (enclosed or available from specialist dealer) to the air outlet. Attach the exhaust-air duct to the adapter.

Constructa CD22130 — Before installation diagram (page 5)
Fig. 5 · Before installation

The extractor hood can be used without restriction in circulating air mode – with an activated carbon filter.

Connecting to Ø120 mm exhaustair duct Attach the exhaust-air duct directly to the air outlet.

Exhaust-air mode · q Round pipes

Page 6 of the Constructa CD22130 user manual — WARNING: THIS APPLIANCE MUST BE EARTHED
Page 6 · cliquer pour agrandir
Page 6

Before installation

Electrical connection Installation

WARNING: THIS APPLIANCE MUST BE EARTHED

Please note: A wall hanging set can be obtained from your dealer (see section on special accessories) for fastening the hood (e.g. at the end of the row of kitchen units).

The wires in the power cord are colourcod- ed as follows:

The extractor hood is designed for installation between two wall cabinets. 1. Remove grease filter (see Filters and maintenance) 2. Using the enclosed template mark the positions of the screws on the side pan- els of the neighbouring cabinets.

Green and Yellow – Earth Blue – Neutral Brown – Live

Connecting to Ø150 mm exhaustair duct Attach the enlarging adapter (enclosed or available from specialist dealer) to the air outlet. Attach the exhaust-air duct to the adapter.

If you fit your own plug, the colours of these wires may not correspond with the identify- ing marks on the plug terminals.

Constructa CD22130 — WARNING: THIS APPLIANCE MUST BE EARTHED diagram (page 6)
Fig. 6

Proceed as follows: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow.

2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black.
3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red.

If a backflow flap has been installed, check that it functions properly.

The extractor hood can also be installed slightly lower, depending on the height of the wall cupboards. Position the template correspondingly lower. Observe the minimum distance from hob to extractor hood of 650 mm (the fixing screws must be fitted at least 1040 mm above the hob). 3. Predrill (with bradawl or 2 mm bit) and screw in the screws to 5 mm.

The extractor hood may be connected to a correctly installed earthed socket only. Attach the earthed socket near the extrac- tor hood in an accessible position.

Circulating-air mode With activated carbon filter if exhaust-air mode is not possible. The air purified by an additional activat- ed carbon filter is returned to the room.

q The earthed socket should be connec-

ted via its own power circuit. If appliances do not feature the OFF delay function, the indicator may start flas- hing when the extractor hood has been switched off for several hours via a separate switch, even though the grease filters are not yet saturated. (See Filters and maintenance).

Constructa CD22130 — WARNING: THIS APPLIANCE MUST BE EARTHED diagram (page 6)
Fig. 7

Electrical specifications: These can be found on the rating plate inside the appliance following removal of the filter frames. Before carrying out repairs, always isolate the appliance.

4. Suspend the extractor hood on the two screws between the wall cabinets.

After installing the extractor hood, insert the activated carbon filter. For installing see Filters and maintenance. If the extractor hood is installed beneath a cabinet, ensure that there is an adequate air outlet (min. 177 cm2). The extractor comes as standard equip- ped with a protective grid in the air connec- tor. If this is has been removed (in the case of exhaust air operation), the air connector must be supplemented by a reducer piece with protective grid (see section on special accessories).

Length of the connection cable: 1.30 m.

If permanent connection is required:

The extractor hood may only be con nected by an electrician registered with the local electricity board.

5. The two door carriers of the extractor flap must be pushed into the appliance to he stops.

A disconnecting device must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as dis- connecting devices. These include LS switches and contactors. If the connecting cable for this applian- ce is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. This extractor hood complies with EU regu- lations on interference suppression.

6. Align the extractor hood with the leading edge of the side cabinets.
Page 7 of the Constructa CD22130 user manual — Installation
Page 7 · cliquer pour agrandir
Page 7

Installation

Keep precisely to the dimension 570 ± 2. 3. Screw the door carriers to the door, making sure your left-right orientation is correct.

7. Mark the position of the lower fixing screws, predrill and fasten the screws.
8. All four fixing screws must be firmly tightened.
9. Connect pipes.
10. Connect electricity.
4. Insert the complete door into the extractor hood Check that the door meets the stops on both sides when pulled out. This means that it is safely locked in place. The red plastic catches can only be released if the door is not swung out to the stop. 5. The two screws to the right and left inside the housing can be used to adjust door gliding according to the weight of the door.

Mounting the door: Door thickness: min. 16 mm Door height: 380 to 700 mm Door weight: 7 kg (max.)

In order to match the wall cabinets on either side, the door can project at the top and bottom.

Constructa CD22130 — Installation diagram (page 7)
Fig. 8 · Installation

Turning the screws clockwise will make the door more difficult to move. Mounting wall covering rail:

1. Remove the two door carriers to the right and left, by pulling both the red plastic catches inwards and removing the door carrier out towards you.

The gap between the hood and the rear wall can be dressed with the enclosed covering rail. Screw-fasten the covering rail to the under- side of the extractor hood. Refit the grease filter.

Constructa CD22130 — Installation diagram (page 7)
Fig. 9 · Installation

If the unit door has to be removed: Pull the red plastic catches in the housing on both sides inwards to release the door, which can then be pulled out towards you.

2. Mark the fixing points on the door. For dimensions of vertical screw fixings, see:
Constructa CD22130 — Installation diagram (page 7)
Fig. 10 · Installation

If the top edge of the door is not flush with the top edge of the cabinet, amend the dimensions accordingly. If the tops of the cabinets are not installed flush with each other, the door must be mounted correspondingly higher.

The screw locations on the door can be marked directly on the door in situ. If you are doing this, leave the door carriers in the appliance. Position the door, align it and mark the back.

We reserve the right to construction changes within the context of technical development.

+ · 570 285 285 · +

Poser une question sur : Constructa CD22130

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Constructa CD22130

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Constructa CD22130 manuel PDF

56 pages·8.6 MB·Hotte de cuisine·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…