FR
Constructa logo
Notice d'utilisation officielle

Constructa CD11350

56 pages·4.6 MB·Hotte de cuisine·PDF·ENJA
Constructa CD11350
Table des matières 13 sections Operating modes · Before using for the first time · Operating the extractor hood · Filters and maintenance · … AfficherMasquer
Page 1 of the Constructa CD11350 user manual — Before using for the first time
Page 1 · cliquer pour agrandir
Page 1
Constructa CD11350 — Operating modes diagram (page 1)
Fig. 1 · Operating modes

Operating modes

Before using for the first time

Circulating-air modeK An activated carbon filter must be

This extractor hood is designed for do- mestic use only. Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced im- mediately to prevent the remaining bulbs from overloading. Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Do not flambé food directly under the extractor hood.

fitted for this operating mode (see Filters and maintenance). The activated carbon filter can be purchased as an optional accessory FROM YOUR DEALER. The corresponding accessory numbers can be found at the end of these operating instructions. K The extractor-hood fan extracts the

kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen. K The grease filter absorbs the grease

particles in the kitchen vapours. K The activated carbon filter binds the

Risk of grease filter catching fire due ! to flames. The hotplates must always be covered with a utensil. Restrictions apply to the use of the ex- tractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).

odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours. If the extractor hood is switched from exhaust-air mode to circulating-air mode, the exhaust-air opening must be sealed to prevent a hazardous situation (see optional accessories in the Instructions for use).

Operating modes

Exhaust-air modeK The extractor-hood fan extracts the

kitchen vapours and conveys them through the grease filter into the atmosphere. K The grease filter absorbs the solid

Gas hobs / Gas cookers Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.

particles in the kitchen vapours. K The kitchen is kept almost free of grease

and odours. D If the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply which the heater requires for combustion. Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.

Before using for the first time

versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. K This extractor hood complies with all

relevant safety regulations. Repairs should be carried out by qualified technicians only. Improper repairs may put the user at considerable risk. K Before using your appliance for the first

Constructa CD11350 — Before using for the first time diagram (page 1)
Fig. 2 · Before using for the first time

time, please read these Instructions for Use carefully. They contain important in- formation concerning your personal safety as well as on use and care of the appliance. K Please retain the operating and

If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the following:

installation instructions for a subsequent owner. Do not use the appliance if damaged. The appliance may be connected to the mains by a qualified technician only. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to en- sure they do not play with the appliance. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his custo- mer service or a similarly qualified person in order to prevent serious injury to the user. Dispose of packaging materials properly (see Installation instructions).

Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached.

Page 2 of the Constructa CD11350 user manual — Filters and maintenance
Page 2 · cliquer pour agrandir
Page 2

Operating the extractor hood

Filters and maintenance

Cooking vapours are best eliminated by: K Switching on the extractor hood when

Removing and installing the metal filter: 1. Press in the interlocks on the left and right sides of the filter grille.

Cleaning the metal grease filtersK In normal operation (1 to 2 hours daily),

the metal grease filter must be cleaned 1 x a month. K The filters can be cleaned in a dish-

you start cooking. K Only switching off the extractor hood

a few minutes after you have finished cooking.

washer. It is however possible that they will become slightly discoloured. K The filter must be placed loosely, and

NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. K When cleaning the filters by hand, soak

them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off.

2. Remove the filter grille.

Filters and maintenance

Different grease filters can be used to absorb the grease particles in the kitchen vapours.

Removing and installing the metal filter (See details for removing/inserting the fleece filter): 1. Clean the filter grille and the filter mats. 2. Re-insert the cleaned filter mats and clamp them with the wire grille. Ensure that there is no gap in the middle.

Fleece grease filter: The filter mat consists of highly flammable material. Warning: A build up of greasy residue increases flam- mability, and the function of the extractor hood may be impaired. Important: Replace the fleece grease filter in good time, otherwise there is a risk of fire from the heat which accumulates during deep- fat frying or roasting.

3. Remove the wire grille and the saturated filter mats.

Activated carbon filter: For binding the odorous substances in circulating-air mode. (See details for removing/inserting the flee- ce filter.) 1. Insert the screws through the wing nuts and sleeves and screw the screws into the left and right sides of the intermediate base (required only during the initial installation). Screws, wing nuts and sleeves are enclosed with the activated carbon filter –. 2. Using a screwdriver or similar tool, press the two lugs on the housing inwards (required only during the initial installation).

Replacing the fleece grease filterK During normal operation (daily 1 to 2
4. Clean the filter grille and insert a new filter mat. 5. Clamp the filter mat with the wire grille. 6. Re-insert the filter grille. The interlocks must lock into position on the left and right sides.

hours) the fleece grease filter must be replaced every 8 to 10 weeks. Replace printed fleece grease filters at the latest when the coloured print dissolves. K Use only original filters.

These comply with the safety regulations and ensure optimum function.

Metal grease filter: The filter mats consist of non-flammable material. Warning: A build up of greasy residue increases flam- mability, and the function of the extractor hood may be impaired. Important: Replace the metal grease filter in good time, otherwise there is a risk of fire from the heat which accumulates during deep-fat frying or roasting.

Disposal of the old fleece grease filter: K Fleece grease filters do not contain any

harmful substances. They can be disposed of as bio-degradable waste.

Show 4 more labels / short text on this page
Light Fan settings · Off · Low Off High · On
Page 3 of the Constructa CD11350 user manual — Filters and maintenance
Page 3 · cliquer pour agrandir
Page 3

Filters and maintenance

Cleaning and care

Replacing the light bulbs

3. Insert the activated carbon filter at the rear, fold up and lock into position on the left and right with the wing nuts. The lugs on the left and right sides of the activated carbon filter are folded in for the 50 cm wide extractor hood. They must be folded up for the 60 cm and 90 cm wide extractor hoods.

Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! K Clean the extractor hood with a hot soap

1. Switch off the extractor hood and isolate the extractor hood by pulling out the mains plug or switching off the fuse. 2. Remove the grease filter (see Filters and maintenance). 3. Replace the bulb (standard filament bulb, max 40 W, E14 bulb holder).

solution or a mild window cleaner. K Do not scrape off dried-on dirt but wipe

off with a damp cloth. K When cleaning the grease filters, remove

Constructa CD11350 — Filters and maintenance diagram (page 3)
Fig. 3 · Filters and maintenance

grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. K Note: Do not use alcohol (spirit) on

plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is ade- quately ventilated. Avoid naked flames! Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons.

4. Re-insert the grease filters. 5. Reconnect the power by inserting the mains plug or by switching on the fuse.
Stainless steel surfacesK Use a mild non-abrasive stainless steel
Replacing the activated carbon filterK During normal operation (daily 1 to 2

cleaner. K Clean the surface in the same direction

hours) the activated carbon filter must be replaced approximately 1 x year. K The activated carbon filter can be pur-

as it has been ground and polished. K We recommend our stainless steel

chased FROM YOUR DEALER (see Optional accessories). K Use only original filters.

cleaner no. 461731. See enclosed service booklet for order address.

These ensure optimum function.

Aluminium and plastic surfaces: K Do not use dry cloths. K Use a mild window cleaning agent. K Do not use aggressive, acidic or caustic

Disposal of the old activated carbon filter: K Activated carbon filters do not contain

any harmful substances. They can be disposed of as residual waste.

cleaners.

Observe the warranty regulations in the enclosed service booklet.

Page 4 of the Constructa CD11350 user manual — Installation Instructions:
Page 4 · cliquer pour agrandir
Page 4

Installation Instructions:

Prior to installation

Important information

Constructa CD11350 — Installation Instructions: diagram (page 4)
Fig. 4 · Installation Instructions:

Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 650 mm, Fig. 1. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.

The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air must not be discharged via a smoke or exhaust gas flue which is already in use or via a shaft which is used for ventilating rooms in which fireplaces are located. Discharge exhaust air in accordance with official and statutory regulations (e.g. national building regulations). Discharge of air into smoke or exhaust air flues which are not in use requires the con- sent of a heating engineer. D If the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply which the heater requires for combustion. Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.

This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and gas cookers. The extractor hood can be used without restriction in circulating air mode – with an activated carbon filter. An extractor hood which is operated in exhaust-air mode should be fitted with a one-way flap if there is no one-way flap in the exhaust-air pipe or wall box. If a one-way flap is not supplied with the appliance, you can purchase one from your dealer (see optional accessories in the Instructions for use). Do NOT cut out the inner part of the exhaust-air connection. Fitting the one-way flap: K Insert the two lugs on the one-way flap

Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1.

into the holes in the exhaust-air connection.

Page 5 of the Constructa CD11350 user manual — Electrical connection
Page 5 · cliquer pour agrandir
Page 5

Before installation

If the exhaust air is conveyed through the exterior wall, a telescopic wall box should be used.

To prevent damage to the fan, hold the tool vertically. K Remove the broken off metal part

K Cut off the outer part of the exhaust-air

connection.

(possibly a noisy and disruptive procedure). K If the pipe diameter is 120 mm, cut out

the inner part of the exhaust-air connection.

K Insert the inner part and turn as far as

possible.

Optimum performance of the extractor hood: K Short, smooth exhaust-air pipe. K Minimum number of pipe bends. K Largest possible pipe diameter

(120 mm dia. recommended) and large pipe bends. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. K Round pipes:

K Insert the exhaust-air connection and

turn as far as possible.

Exhaust air towards the rearPipe diameter: 100 mm K Break off cover on the rear panel of the

K With activated carbon filter if exhaust-air

mode is not possible. K The air purified by an additional

extractor hood; strike the retaining points with a tool.

activated carbon filter is conveyed back into the room. K For insertion of the activated carbon

filter see Instructions for use. K If the extractor hood is switched from

Short discharge pipe: Inner diameter at least 100 mm, extended discharge pipe: Inner diameter at least 120 mm. K Flat ducts must have an inner cross-

exhaust-air mode to circulating-air mode, the exhaust-air opening must be sealed to prevent a hazardous situation (see optional accessories in the Instructions for use).

section equivalent to round pipes with an inner diameter of 100/120 mm. There should be no sharp bends. 100 m dia approx. 178 cm2 125 m dia approx. 113 cm2

To prevent damage to the fan, hold the tool vertically. K Remove the broken off metal part

(possibly a noisy and disruptive procedure). K If the extractor hood has 2 motors, the

Electrical connection

K If pipe diameters differ:

Insert sealing strip. K Ensure an adequate air supply for

opening on the plastic part must be made at the rear; cut through the 3 ribs and remove the cut-off part.

exhaust-air mode.

Exhaust air upwards: Pipe diameter: 100 or 120 mm K Break off cover on the top of the

Constructa CD11350 — Electrical connection diagram (page 5)
Fig. 5 · Electrical connection

Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identify- ing marks on the plug terminals. Proceed as follows: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red.

extractor hood; strike the retaining points with a tool.

Circulating-air mode

Page 6 of the Constructa CD11350 user manual — Fitting the extractor hood
Page 6 · cliquer pour agrandir
Page 6

Electrical connection

Fitting the extractor hood

The extractor hood may be connected to a correctly installed earthed socket only. Attach the earthed socket near the extractor hood in an accessible position. K The earthed socket should be

90 cm wide extractor hood: With 5 screws.

60 cm wide extractor hood: With 4 screws.

connected via its own power circuit. K If the earthed socket is no longer

accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector. If appliances do not feature the OFF delay function, the indicator may start flas- hing when the extractor hood has been switched off for several hours via a separate switch, even though the grease filters are not yet saturated. (See instructions for use, section on filter and maintenance).

1. Mark mounting boreholes. Dimensions can be found in or use template. 2. Drill 8 mm dia. holes and insert wall plugs flush with the wall. 3. Screw in the upper screws (on left and right) until there is a gap of approx. 7 mm between the screw head and the wall.

If permanent connection is required: The extractor hood may only be connected by an electrician registered with the local electricity board. A disconnecting device must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnecting devices. These include LS switches and contactors.

90 cm wide extractor hood: With 6 screws.

Electrical specifications: These can be found on the rating plate inside the appliance following removal of the filter frames. Before carrying out repairs, always isolate the appliance. Length of the connection cable: 1.30 m. This extractor hood complies with EU regulations on interference suppression.

4. Remove the filter grille (see Instructions for use) 5. Attach the extractor hood. 6. Tighten the lower screw (with washer) inside the extractor hood.

To a wall-hanging cupboard 50 cm wide extractor hood: With 4 screws.

Fitting the extractor hood

Constructa CD11350 — Fitting the extractor hood diagram (page 6)
Fig. 6 · Fitting the extractor hood

To the wall 50 cm wide extractor hood: With 3 screws.

1. Dimensions for the mounting boreholes can be found in, or place a template on the base of the wallhanging cupboard. 2. Mark the mounting holes and make pilot holes with a bradawl. In exhaust-air mode (upwards) mark the exhaust-air opening and saw out. K Consider the location of the

connection cable; if required, saw out the cupboard. 3. Remove the filter grille (see Instructions for use). 4. Screw the extractor hood to the base of the cupboard.

560 898

Page 7 of the Constructa CD11350 user manual — Final assembly
Page 7 · cliquer pour agrandir
Page 7

Final assembly

Constructa CD11350 — Final assembly diagram (page 7)
Fig. 7 · Final assembly
Exhaust-air modeK Stick the enclosed covering foil over the

2-motor extractor hood Selecting the operating mode: K Exhaust-air mode: Position 1 K Circulating-air mode: Position 2 K Select the operating mode on the left or

air outlet grille on the top of the extractor hood. Ensure that the surface is clean.

K Connect to the power supply. K Insert the filter grille

Design changes with respect to technical development shall remain withheld.

Poser une question sur : Constructa CD11350

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Constructa CD11350

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Constructa CD11350 manuel PDF

56 pages·4.6 MB·Hotte de cuisine·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…