FR
AEG logo
Notice d'utilisation officielle

AEG DKE 75

64 pages·2.3 MB·Chauffage·PDF·ENITJA
AEG DKE 75
Table des matières 15 sections OPERATING INSTRUCTIONS For your safety · -- Do not use the product in rooms saturated with explosive gas, · accessible. -- Never position this appliance immediately underneath a power · OPERATING INSTRUCTIONS Your product · … AfficherMasquer
Page 1 of the AEG DKE 75 user manual — OPERATING INSTRUCTIONS For your safety
Page 1 · cliquer pour agrandir
Page 1

OPERATING INSTRUCTIONS For your safety

Before operating the heater, please read these instructions thoroughly to avoid damage and hazardous situations. Any use of this heater other than that stipulated in this instruction manual may cause fire, electric shock or injury, and voids all warranties.

Warranty does not apply to any defect, deterioration, loss, injury or damage caused by, or as a result of, the misuse or abuse of this heater. The rights dictated by State law are not prejudiced. None of the terms of this warranty are to be taken as excluding any condi- tions or warranties implied by State law, which cannot be excluded or modified.

-- Before any operation remove the packaging and check product integrity. In case of defects or damages do not try to repair it your-

self but contact your dealer. -- Do not let children play with the packaging and protect the environment by disposing of the packaging in accordance with the na-

tional regulations for waste processing.

1. For your safety -- This appliance is intended for normal household use and not for

use in commercial/industrial environment, in vehicles or on board ships or aircrafts. -- This appliance can be used by children aged from 8 years and

above and persons with reduced physical, sensory or mental ca- pabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. -- Children of less than 3 years should be kept away unless conti-

nuously supervised. -- Children aged from 3 years and less than 8 years shall only switch

on/off the appliance provided that it has been placed or instal- led in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. -- CAUTION: Some parts of this product can become very hot and

cause burns. Particular attention has to be given where children and vulnerable people are present. -- Make sure that the mains power supply matches the rated input:

230V AC, 50Hz.

20

Page 2 of the AEG DKE 75 user manual — accessible. -- Never position this appliance immediately underneath a power
Page 2 · cliquer pour agrandir
Page 2

OPERATING INSTRUCTIONS For your safety

-- Never allow animals or children to play with or touch the product.

ter. Do not hang anything on the heater and do not cover it while it’s working. This is clearly written on the cover of the product or shown by the symbol:

-- Do not use the product in rooms saturated with explosive gas,

vapours generated by solvents or paints or flammable vapours/ gas. -- If the cable is damaged, do not repair it yourself but take the pro-

duct to the technical service or a qualified repair centre and have it repaired by specialised personnel in order to avoid any risk of damage. -- Always position the product so that the plug is immediately

accessible. -- Never position this appliance immediately underneath a power

socket. -- Do not insert objects or paper into the radiator.

21

Page 3 of the AEG DKE 75 user manual — OPERATING INSTRUCTIONS Your product
Page 3 · cliquer pour agrandir
Page 3

OPERATING INSTRUCTIONS Your product

2. Your product

Other than the heater you have chosen the package includes (picture 1):

-- 1x metal brackets for wall mounting (fixed to the radiator); -- 4x nylon plug expansion 8x50mm; -- 4x 5x60mm cross head screws to fix wall brackets;

Refer to your dealer if something is broken or missing.

3. Safe positioning -- Only use the product in its horizontal position; -- This product is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth connection; -- Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 2. -- Never install the product on a surface made from wood or synthetic material. -- This product is water resistant to IP24. It may therefore be used in bathrooms or other areas subject to humidity provided it is

never installed within the perimeter of bathtubs or showers (Volume 1 of figure 2). -- Do not install the radiator in a draft that could disturb its regulation.

4. Installation f f Remove the wall-mounting bracket fixed to the back of the radiator, by releasing first the 2 upper springs and then the 2 lower

springs as shown in figure 4. f f Rest the bracket on the floor to use it as a template to mark the points at which the two lower fixing holes are to be made (figure

5A). f f Lift the bracket until its lower fixing points coincide with the marks made on the wall before, and use a pencil to mark the position

of the two upper fixing points (figure 5B). f f Drill the 4 holes at the points marked previously, and insert the plastic plugs (figure 6).

f f Fix the bracket to the wall using the 4 screws supplied (figure 7).

f f Hook the radiator to the bracket starting with the 2 lower fixing points, and then click the 2 upper fixing points into position (figu-

re 8). f f Should you have to remove the radiator from the bracket at a later stage, we recommend releasing the lower two fixing points

first and then the upper fixings.

5. Electrical connections -- The product must be powered at a voltage of 230V AC 50Hz. -- The product must be supplied with a cable and plug. If a product with plug is installed in France, connect it to the mains power

supply by cutting off the plug and using a suitable connection box. -- In bathrooms, kitchens or other humid areas, install the connection terminal at least 25cm off the floor. -- The electrical connection to the mains power supply must also include a 2-pole switch with a minimum contact aperture of 3mm.

As a priority, always abide by your national wiring rules. -- If the product is powered through a 30mA differential switch, make sure the pilot wire is also controlled by the differential switch.

22

Page 4 of the AEG DKE 75 user manual — 6.2 Operating
Page 4 · cliquer pour agrandir
Page 4

6. Using the product

6.1 Description of controls

A – Switch on/Stand-by B – Operating mode C – Special functions D – Increase / Activate E – Decrease / Deactivate F – Display G – Main switch

AEG DKE 75 — 6.1 Description of controls diagram (page 4)
Fig. 1 · 6.1 Description of controls

6.2 Operating

6.2.1 Switching on the screen

If the screen is not switched on, push any key to make it light up.

AEG DKE 75 — 6.2 Operating diagram (page 4)
Fig. 2 · 6.2 Operating

When the screen is switched off, the first time any key is pushed the screen lights up without activating the function controlled by the key pushed.

The screen lights up and stays on for 30 seconds after the last time any key is pushed.

6.2.2 Switching the radiator on and off

The power supply to the radiator is controlled by a two-pole electromechanical switch (G) located on the right side of the radiator. When this switch is used the power supply to the electronic board is also switched off and, as a result, all the parameters saved are lost after about 30 minutes, and the default settings are reinstated.

We recommend only using this switch if the radiator is not to be used for a long period of time, and to rather use the Switch on / Stand by button (A) for switching off for short periods, in order to avoid losing the settings saved.

When the radiator is switched on using the main switch on its side, the display lights up and the stand- by symbol is displayed.

To switch on the radiator, push the Switch on / Stand- by key.

AEG DKE 75 — 6.2 Operating diagram (page 4)
Fig. 3 · 6.2 Operating

The radiator always comes on in comfort mode. If the radiator is new or the power supply has been off for more than 30 minutes, the comfort temperature is at the default value of 19°C.

AEG DKE 75 — 6.2 Operating diagram (page 4)
Fig. 4 · 6.2 Operating

To switch off the radiator, hold down the Switch on / Stand-by key for at least 3 seconds.

Switching the radiator off using the rocking switch on its side for more than 30 minutes results in the loss of all data saved (date, time, temperature setting, etc.).

AEG DKE 75 — 6.2 Operating diagram (page 4)
Fig. 5 · 6.2 Operating

23

Page 5 of the AEG DKE 75 user manual — 6. Using the product
Page 5 · cliquer pour agrandir
Page 5

6.2.3 Selecting the operating mode

Pressing the „M“ key repeatedly allows you to select the operating mode you require.

The operating modes are activated in the following order:

AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 6 · 6. Using the product
AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 7 · 6. Using the product
AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 8 · 6. Using the product

Once 30“ has elapsed since the „M“ key was last pus- hed, the operating mode activation sequence begins from the beginning again, to make it quicker to switch from any mode to Comfort mode.

Icon Description When used

Comfort When at home. The radiator works to maintain the comfort temperature set.

Eco When you are away from home for short periods (from 2 to 48 hours) or you are sleeping. The radiator works to maintain the eco temperature set and save energy.

Anti-freeze When you are away from home for long periods (more than 48 hours). The temperature is automatically set at 7±3°C and cannot be changed.

Program 1 When you want preset programmed operation, suitable for those that do not work from home. THIS PROGRAM CAN ALSO BE CUSTOMIZED FOLLOWING THE INSTRUCTIONS LISTED IN PARAGRAPH 6.2.6.

Program P2 When you want preset programmed operation, suitable for holiday homes used at the weekend.

Program P3 When you want preset programmed operation, suitable for offices and work- places.

Pilot wire When checking operation of the radiator, using an external control unit with a pilot wire.

6.2.3.1 Description of preset programmes

AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 9 · 6. Using the product
AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 10 · 6. Using the product
AEG DKE 75 — 6. Using the product diagram (page 5)
Fig. 11 · 6. Using the product
Show 11 more labels / short text on this page
Monday-Friday · Saturday-Sunday · Monday-Thursday · Friday · Saturday-Sunday · Monday-Friday · Saturday-Sunday · = temperature „COMFORT“ · = temperature „ECO“ · = temperature anti-freeze · 24
Page 6 of the AEG DKE 75 user manual — 6. Using the product
Page 6 · cliquer pour agrandir
Page 6

The program P1 can be customized following the instructions listed in paragraph 6.2.6.

The programmes P2 and P3 are preset and cannot be changed, other than in the case of comfort and eco temperature values.

To set the temperatures (valid for all programmes):

f f Select Comfort operating mode and set the relevant temperature.

f f Select Eco operating mode and set the relevant temperature.

f f Select the programme required P1, P2 or P3.

Please note: When you select programme P1 without ever having set the current date and time, the system will automatically switch to the regulation mode explained in paragraph 6.2.5.

6.2.3.2 Using the pilot wire

If a connection cable is supplied without a plug, the radiator can also be controlled using specific programmers.

The comfort temperature used in Pilot Wire mode is set, as already explained for the preset programmes, by going to Comfort mode first, using the „M“ key and then selecting the value required using the „+“ and „-“ keys.

Please note: In Pilot Wire mode, the Eco temperature is always equal to the Comfort temperature less 3,5°C.

6.2.4 Setting the temperatures

The radiator is characterised by 2 reference tempe- ratures, comfort and eco, which can be set indepen- dently.

An arrow to the right of the display moves along a scale from green to red to indicate whether the tem- perature differs more or less from the recommended value of 19°C.

The preset comfort temperature is 19,0°C and can be changed using the “+” o “-“ keys.

AEG DKE 75 — 6. Using the product diagram (page 6)
Fig. 12 · 6. Using the product

If the comfort temperature is set at a value lower than the eco temperature, the latter is automatically reset at the comfort value - 0,5°C.

AEG DKE 75 — 6. Using the product diagram (page 6)
Fig. 13 · 6. Using the product

The preset eco temperature is 15,5°C and can be ch- anged using the “+” or “-“ keys.

The recommended difference between the comfort and eco temperature values is 3,5°C. If the difference set differs from the suggested value, the eco symbol changes as follows:

The maximum value that can be set for the eco tem- perature is equal to the comfort temperature value - 0,5°C.

If the ambient temperature is lower than the temperature required and displayed, the heating indicator switches on, on the display :

25

Page 7 of the AEG DKE 75 user manual — 6. Using the product
Page 7 · cliquer pour agrandir
Page 7

6.2.5 Setting the day and time

The day and time are set to be able to use the 3 preset programmes, and this can be done by holding down the mode key.

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 14 · 6. Using the product

The day flashes the day to be set (1 = Monday). To edit it, push the “+” or “-“ keys.

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 15 · 6. Using the product

Push the mode key to confirm the day set and move on to setting the time.

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 16 · 6. Using the product

The display flashes the hour to be set. To edit it, push the “+” or “-“ keys.

Push the mode key to confirm the hour set and move on to setting the minutes.

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 17 · 6. Using the product

The display flashes the minutes to be set. To edit it, push the “+” or “-“ keys.

Push the mode key to confirm the minutes set and conclude the setting operation.

The system will go back to the operating mode acti- vated when setting was started.

If you try to activate a preset programme without ha- ving saved the date and time, this setting procedure will be activated automatically.

6.2.6 Customizing P1 Program

Program P1 may be modified to suit the users needs. Modification of P1 gives the user the opportunity to set the wished ambient tem- perature, choosing among Comfort, ECO o Frost Free, for every hour of the day and for the whole week.

Please refer to paragraph 6.2.4 in order to set different levels of temperature to each working Mode.

Each displayed hour of the day, shows the temperature level of P1 Program currently set. In case of first use of the radiator, the set P1 Program profile is the one indicated in Paragraph 6.2.3.1.

In order to display or modify P1 Program, please proceed as follows:

Press “M” to select P1 Program.

In case Time has not been set previously (brand-new product, or lack of power connection longer than 30 min.) the time regulation procedure will be activated automatically (refer to paragraph 6.2.5).

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 18 · 6. Using the product

To display P1 Program hold button “-“ for 3 seconds.

The first day to see/modify is now displayed (1= Monday).

AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 19 · 6. Using the product
AEG DKE 75 — 6. Using the product diagram (page 7)
Fig. 20 · 6. Using the product

26

Page 8 of the AEG DKE 75 user manual — N.B.:
Page 8 · cliquer pour agrandir
Page 8

Press “+” button to enter the first hour to see/modify.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 21

Press “M” button to choose the wished temperature level among Comfort, Eco or Frost Free:

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 22

The displayed temperature once you’ve selected a specific hour of the day, is the one currently set on the P1 Program.

Use “+” and “-“ buttons to enter each hour of day 1 and see/modify the working temperature of each of them.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 23

The hour displayed always indicates the starting point. For example: when H 23 is displayed the mo- dification involves the period of time between 23:00 and 00:00.

Having modified the temperature for each of the 23 hours of Day 1, press further “+” button to enter the modification mode of Day 2.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 24

Press “+” button to diplay/modify the working tem- perature of each hour of Day 2, as descrive for Day 1.

You can set automatically the same program of Day 1 on Day 2 by holding the “F” button and pressing “+” button.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 25

Once the last day (Day 7) has been set, press “+” button to end the program sequence.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 26

END will appear on the display. A further pression of “+” button will allow you to confirm the adjusted program.

“OK“ will appear on the display for 5 second, confir- ming that the Program sequence has been carried out successfully.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 27

To do so, just hold “F” button and press “-“ button.

System is now set to adjust the temperature according to the new adjustment of program P1.

AEG DKE 75 — N.B.: diagram (page 8)
Fig. 28

N.B.:

-- You can abort the display/modification sequence anytime, deleting any settings that have not been saved, just by pressing

“Stand-By” button; -- Restoring the default settings will delete every P1 Program previously created (see paragraph 6.3); -- If no button is pressed within 90 sec. during the Program setting process, the result will be the cancellation of the display/modi-

fication procedure and will restore back the factory default settings; -- During the programmation process, the heating elements will automatically switch to Stand-by mode, and the radiator does not

heat.

27

Page 9 of the AEG DKE 75 user manual — EXAMPLE: HOW TO SET A CUSTOM PROGRAM
Page 9 · cliquer pour agrandir
Page 9

EXAMPLE: HOW TO SET A CUSTOM PROGRAM

Let’s see how to program a brand-new radiator, and anticipate the change from ECO to COMFORT temperature one hour earlier (06:00 a.m. is the default factory settings), for each day from Monday to Friday.

Press “M” to select Program P1.

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 29

Set the current day of the week (first use of the radi- ator) using “+” or “-“ button.

Press “M” and set the current Hour (first use of the radiator) using “+” or “-“ button.

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 30

Press “M” and set the current Minutes (first use of the radiator) using “+” or “-“ button.

Press “M” to end the time setting procedure. System now gets back to Program P1.

Hold “-“ for 3 sec. to enter the display/modification of Day 1.

Press “+” until you’ll see H:05 on the display (that’s the hour we want to modify the ECO temperature level to COMFORT).

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 31

Press “M” two times to change the ECO temperature level to COMFORT.

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 32

Press “+” button until you’ll see D:2 appear on the display (Tuesday).

To copy and paste the same program of Day 1 on Day 2, hold “F” and press “+” button. The system will automatically copy the program and display directly Day 3 (Wednesday).

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 33

Repeat the procedure previously described until D:6 appears on the display.

AEG DKE 75 — EXAMPLE: HOW TO SET A CUSTOM PROGRAM diagram (page 9)
Fig. 34

28

Page 10 of the AEG DKE 75 user manual — 6.3 Special functions
Page 10 · cliquer pour agrandir
Page 10

Since we don’t want to modify Day 6 and 7, we can exit the Program settings mode, holding “F” and pressing “-“ button.

“END” will appear on the display.

Press “+” to confirm the modification process.

“OK” will be flashing on the display for 5 sec.

6.3 Special functions

Repeatedly pushing the „F“ key makes it possible to select the various special functions available in sequence.

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 35 · 6.3 Special functions

To leave the special functions menu, simply wait 12 seconds, or push the „M“ key to go back to viewing the operating mode.

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 36 · 6.3 Special functions

To reinstate all the radiator‘s parameters to the de- fault settings set by the manufacturer hold at least for 3sec the „+“ key down.

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 37 · 6.3 Special functions
AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 38 · 6.3 Special functions

Presence sensor (optional extra)

Switching the function (ON) or (OFF) is done by pus- hing the “+” or “-“ keys respectively.

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 39 · 6.3 Special functions

This function allows the radiator to pick up whether or not people are in the space, and automatically re- gulate the heating level, in order to optimise comfort and energy saving.

For further details see paragraph 6.3.1.

Activation is indicated by the relevant icon that swit-

ches on, on the display:

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 40 · 6.3 Special functions

Switching the function (ON) or (OFF) is done by pus- hing the “+” or “-“ keys respectively.

This function makes it possible to detect an open window and automatically activate the anti-freeze operating mode.

For further details see paragraph 6.3.2.

Activation is indicated by the relevant icon that swit-

ches on, on the display:

AEG DKE 75 — 6.3 Special functions diagram (page 10)
Fig. 41 · 6.3 Special functions

If the consumption indication is flashing, this means that the data saved relates to a period of less than 24 hours.

This function makes it possible to view the power the radiator has consumed over the previous 24 hours.

Please note: The display shows the estimated consumption, which may differ from that measured by specific meters, suitable for the purpose.

Show 4 more labels / short text on this page
Reinstating default settings · Window open sensor · Daily consumption · 29
Page 11 of the AEG DKE 75 user manual — 6.3 Special functions
Page 11 · cliquer pour agrandir
Page 11
AEG DKE 75 — 6.3 Special functions diagram (page 11)
Fig. 42 · 6.3 Special functions

If the consumption indication is flashing, this means that the data saved relates to a period of less than 7 days.

This function makes it possible to view the power the radiator has consumed over the previous 7 days.

Please note: The display shows the estimated consumption, which may differ from that measured by specific meters, suitable for the purpose.

Displaying the ambient temperature

The display shows the ambient temperature measu- red by the radiator.

AEG DKE 75 — 6.3 Special functions diagram (page 11)
Fig. 43 · 6.3 Special functions

Alignment of the ambient temperature

AEG DKE 75 — 6.3 Special functions diagram (page 11)
Fig. 44 · 6.3 Special functions

The display flashes the correction value to be applied. To edit it, push the “+” or “-“ keys.

This function is used to edit the ambient temperature measured by the radiator and used to manage hea- ting power, if it needs to be corrected to compensate for reading errors due to things like being near to heat sources, or cold air draughts.

If, for example, the temperature set on the radiator is 19,2°C and the ambient temperature is measured at 19,5°C, align it by +0,3°C.

Always wait at least 4 hours for the temperature to settle, before doing any alignment.

AEG DKE 75 — 6.3 Special functions diagram (page 11)
Fig. 45 · 6.3 Special functions

Switching the function (ON) or (OFF) is done by pus- hing the “+” or “-“ keys respectively.

This function allows the radiator to be controlled using external timers, piloted sockets with telephonic control, and similar devices.

For further details see paragraph 6.3.3.

6.3.1 Presence sensor

This function allows the radiator to pick up whether or not people are in the space, and automatically regulate the heating level, in order to optimise comfort and energy saving.

Thanks to this function, which can only be activated in Comfort mode, the radiator continuously monitors the room and, if no people are detected, it reduces the comfort temperature set as follows:

Period of absence Reduction of the Comfort temperature Indication on the display

60 min 1,0 °C The presence sensor and comfort mode symbols flash together

90 min 2,0 °C

AEG DKE 75 — 6.3 Special functions diagram (page 11)
Fig. 46 · 6.3 Special functions

120 min 3,5 °C

38 hours Anti-freeze activated 7±3 °C

The reduction of temperature always relates to the comfort temperature. If the radiator is in Eco or Anti-freeze mode, no change in temperature to be maintained in the room will be observed.

Should someone be detected in the room for at least 10 consecutive minutes, the temperature is automatically returned to the comfort temperature set, without any reduction. The same happens if, while the temperature required is being reduced, due to an absence of people being detected in the room, the „M“ key is pushed.

Important: Correct operation of this function may depend on where the radiator is positioned in the room. To choose the best installation position, bear in mind that the sensor detects movements within the area indicated in figure 9, and that no objects must be in its way. Presence detection is also more effective when people move in front of the sensor that when they move towards it.

Weekly consumption · Remote control · 30

Page 12 of the AEG DKE 75 user manual — 6.4 Utilities
Page 12 · cliquer pour agrandir
Page 12

6.3.2 Open window sensor

This function makes it possible to detect an open window and automatically activate the Anti-freeze operating mode.

If a sudden reduction is temperature is detected when the radiator is operating normally, anti-freeze mode is activated automatically to reduce energy wastage. On the display the window and anti-freeze symbols flash together, while the symbol for the operating mode set by the user stays on.

AEG DKE 75 — 6.4 Utilities diagram (page 12)
Fig. 47 · 6.4 Utilities

Reinstating normal operation does not occur automatically, but must be activated by pushing the „M“ key.

6.3.3 Remote control

This function allows the radiator to be controlled using external timers, piloted sockets with telephonic control, and similar devices. When the function is active, if the radiator‘s power supply is reinstated after being interrupted for more than 30 minutes, when it is switched on Stand-by mode is not set as normally happens, by Comfort mode starts immediately. The comfort temperature is as set before the power supply was interrupted. The (optional) presence sensor and open window sensor are deactivated. This means that the radiator can be switched on without being in the room.

6.4 Utilities

AEG DKE 75 — 6.4 Utilities diagram (page 12)
Fig. 48 · 6.4 Utilities

Once the display reads „LOC“:

The radiator‘s controls can be locked to prevent set- tings being changed accidentally, or by unauthorised people.

Hold the „F“ key down and push the „+“ key to lock the controls.

AEG DKE 75 — 6.4 Utilities diagram (page 12)
Fig. 49 · 6.4 Utilities

To go to lock/unlock mode, hold the „F“ key down.

Activation is indicated by the relevant icon that swit-

ches on, on the display:

Hold the „F“ key down and push the „-“ key to unlock the controls.

AEG DKE 75 — 6.4 Utilities diagram (page 12)
Fig. 50 · 6.4 Utilities

When this function is activated, in case the supply voltage returns after an interruption exceeding 30min, the operating mode set at the time of the interruption is recovered. If the operating mode was one of the three programs P1, P2 or P3 the frost free program is activated instead, because it is necessary to set the time and the day of the week before activating again a program.

Lock controls · 31

Page 13 of the AEG DKE 75 user manual — 9. Legal notice
Page 13 · cliquer pour agrandir
Page 13

OPERATING INSTRUCTIONS Troubleshooting

7. Troubleshooting

The radiator does not switch on. Check that the power supply is on and that it is as indicated in the radiator‘s nameplate (e.g. 230 Vac 50 Hz), and that the main switch on the right side of the radiator is switched on (position „I“).

The radiator does not heat up. Make sure that the operating mode is as required and, if using a preset programme, that you are not in a time period for which anti-freeze mode is set.

If the ambient temperature is higher than that set, the radiator should not heat up.

If in doubt, set Comfort mode and a required temperature much higher than the ambient tem- perature, to check that the radiator is working properly.

The radiator stays hot. Check that the temperature setting is not too high or that there are no draughts on the radiator, altering the ambient temperature measured.

The radiator does not heat up enough.

Check that the temperature setting is not too low, that the radiator is only heating the room in which it is installed (keep the doors closed) and that the mains power supply is correct.

The radiator heats in Eco mode. The radiator may heat up to reach / maintain the eco temperature. This is not abnormal operation.

The radiator‘s surface is very hot. It is normal for the surface to be hot when working. The maximum values comply with the limits

laid down by applicable safety norms.

If the radiator is always very hot, it may be undersized for the space in which it is used, or may be affected by draughts.

The temperature in the room dif- fers from the temperature set.

Having waiter for the ambient temperature to stabilise for at least 4 hours, you may have to compensate for any differences between the temperature indicated by the radiator and that measured in the room. To do this see the contents of paragraph 6.3 on the section „Aligning the outside temperature“.

The radiator gives off an unplea- sant odour.

When the radiator is new, it is possible that when it begins working for the first time an unpleasant odour may be sensed. This is due to residue from the manufacturing process.

Radiators that have already been used may give off unpleasant odours if they are not used for a long time and/or if they are used in polluted spaces with poor quality air.

8. Maintenance -- This product does not require any special maintenance. -- Clean the product, especially the heating panel, with a dry cloth once every 6 months. -- If the product requires repairing, contact an authorised technical service centre. -- When replacing the power cable, use a 2x1,00mm2 or 3x1,00mm2 H05V2V2-F HAR type, depending on the version. This operation,

for cables both with and without plugs, must be performed by qualified personnel and never by the end user in order to avoid da- maging the appliance and jeopardising personal safety.

9. Legal notice

Please help us to protect the environment by disposing of the packaging in accordance with the national regulations for waste processing.

Recycling of obsolete appliances

Appliances with this label must not be disposed off with the general waste. They must be ollected separately and dis- posed off according to local regulations.

Problem Solution · Environment and recycling · 32

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
The radiator does not switch on.Check that the power supply is on and that it is as indicated in the radiator‘s nameplate (e.g. 230 Vac 50 Hz), and that the main switch on the right side of the radiator is switched on (position „I“). p.13
The radiator does not heat up.Make sure that the operating mode is as required and, if using a preset programme, that you are not in a time period for which anti-freeze mode is set. If the ambient temperature is higher than that set, the radiator should not heat up. If in doubt, set Comfort mode and a required temperature much higher than the ambient tem- perature, to check that the radiator is working properly. p.13
The radiator stays hot.Check that the temperature setting is not too high or that there are no draughts on the radiator, altering the ambient temperature measured. p.13
The radiator does not heat up enough.Check that the temperature setting is not too low, that the radiator is only heating the room in which it is installed (keep the doors closed) and that the mains power supply is correct. p.13
The radiator heats in Eco mode.The radiator may heat up to reach / maintain the eco temperature. This is not abnormal operation. p.13
The radiator‘s surface is very hot.It is normal for the surface to be hot when working. The maximum values comply with the limits laid down by applicable safety norms. If the radiator is always very hot, it may be undersized for the space in which it is used, or may be affected by draughts. p.13
The temperature in the room dif- fers from the temperature set.Having waiter for the ambient temperature to stabilise for at least 4 hours, you may have to compensate for any differences between the temperature indicated by the radiator and that measured in the room. To do this see the contents of paragraph 6.3 on the section „Aligning the outside temperature“. p.13
The radiator gives off an unplea- sant odour.When the radiator is new, it is possible that when it begins working for the fri st time an unpleasant odour may be sensed. This is due to residue from the manufacturing process. Radiators that have already been used may give off unpleasant odours if they are not used for a long time and/or if they are used in polluted spaces with poor quality air. p.13

Poser une question sur : AEG DKE 75

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le AEG DKE 75

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

AEG DKE 75 manuel PDF

64 pages·2.3 MB·Chauffage·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…