USSC 1 King/Ashley Pellet S tove Please read this entire manual before installation and use of this appliance. Failure to follow these instructions could result in property damage, bodily injury, or even death. Contact your local building or fire officials about restrictions and installation inspection requirements in your area.
2 USSC T ABLE OF CONTENTS .............................................................................................. 2 SAFETY PRECAUTIONS ........................................................................................... 3 SPECIFICA TIONS .
USSC 3 Safety Precautions IMPORT ANT : Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury , or even death. Proper installation of this stove is crucial for safe and ef ficient operation.
4 USSC Specifications Heat Output 1 48,000 BTU/hr . Heating Capacity 2 800 - 2,000 sq. f t. Fuel Burn Rate 3 2.0 - 6.0 lbs./hr . Burn T ime (lowest setting) 5500/5500M - 60 hrs. 5500XL - 160 hrs. Hopper Capacity 5500/5500M - 150 lbs. 5500XL - 320 lbs.
USSC 5 INST ALLA TION OPTIONS Read this entire manual before you inst all and use your King/Ashley stove. Failure to follow instructions may result in property damage, bodily injury , or even death! (.
6 USSC Installation CLEARANCES Y our King/Ashley stove has been tested and listed for installation in residential, mobile home, and alcove applications in accordance with the clearances given in FIGURES 3-5 and T ABLE 1.
USSC 7 Installation VENTING REQUIREMENTS Inst all vent at clearances specified by the vent manufacturer . Do not connect the pellet vent to a vent serving any other appliance or stove. Do not inst all a flue damper in the exhaust venting system of this unit.
8 USSC Installation VENT TERMINA TION CLEARANCES: A) Minimum 4-foot clearance below or beside any door or window that opens. B) Minimum 1-foot clearance above any door or window that opens. C) Minimum 3-foot clearance form any adjacent building. D) Minimum 7-foot clearance from any grade when adjacent to public walkways.
USSC 9 Installation THROUGH THE W ALL INST ALLA TION (RECOMMENDED INST ALLA TION) T o vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter . If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall.
10 USSC Installation OUTSIDE AIR SUPPL Y (optional) Depending on your location and home construction, out side air may be necessary for optimal performance. Metal pipe (solid or flexible) must be used for the out side air inst allation. PVC pipe is NOT approved and should NEVER be used.
USSC 11 Do not operate your stove with the viewing door open. The auger will not feed pellet s under these circumst ances and a safety concern may arise from sp arks or fumes entering the room. This heater is designed and approved for premium hardwood pellet fuel only .
12 USSC CONTROL PANEL T urning the stove OFF/ON, as well as adjustments for the fuel feed rate and distribution blower speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower left-hand side of your King/Ashley stove (see FIGURE 10).
USSC 13 SHUT DOWN PROCEDURE Press the “OFF” button on the control pad to put the stove in shut down mode. At this time, the red light above the pad will illuminate. Once this is done, the auger will stop feeding pellets, but the distribution blower , exhaust blower , and bottom auger will continue to operate.
14 USSC Maintenance Operation DAIL Y OPERA TION The hopper and stove top will be hot during operation; therefore, you should always use some type of hand protection when refueling your stove. Never place your hand near the auger while the stove is in operation.
USSC 15 INTERIOR CHAMBERS Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is advisable to clean out the holes in the burnpot to remove any build up that may prevent air from moving through the burn pot freely .
16 USSC T rouble Shooting Disconnect the power cord before performing any maintenance! NOTE: T urning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical component s of the stove. Never try to rep air or replace any p art of the stove unless instructions for doing so are given in this manual.
USSC 17 Parts Diagram model 5500, 5500M and 5500XL.
18 USSC.
USSC 19 Parts List model 5500/5500M/5500XL Item Part No. Title Qty . 1 86624 Burnpot Assembly 1 2 86625 Housing Assy , Burnpot 1 3 86628 Weldment, Exhaust Duct 1 4 86633 Weldment, Igniter T ube 1 5 80.
20 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR KING OR ASHLEY, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté United States Stove 5500M c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du United States Stove 5500M - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation United States Stove 5500M, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le United States Stove 5500M va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le United States Stove 5500M, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du United States Stove 5500M.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le United States Stove 5500M. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei United States Stove 5500M ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.