Manuel d'utilisation / d'entretien du produit Stockton Log Effect Stove Range du fabricant Stovax
Aller à la page of 27
M a r l b o r o u g h & S t o c k t o n L o g E f f e c t S t o v e R a n g e B al a nc e d F lu e With upgradeable control valve I ns t r uc t io n s f or Us e , I ns t a ll a ti o n a nd Se r v .
2 CONTENTS COVERING THE FOLLOWING MODELS MARLBOROUGH – 8535LUC – P8535LUC STOCKTON – 8570LUC – P8570LUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 .
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full MTM fires only.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must be carried out by a competent person. 1.2 In all correspondence, please quote the appliance type and serial number which can be found on the data badge located at the rear of the stove.
7.2 Place log B on the left hand side of the burner with the location bar on the underside of the log fully located in the long slot of the burner. Make sure the log is as far to the left as possible.
6 7.4 Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 5. 7.5 There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox.
8. THE FLAME FAILURE DEVICE 8.1 This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: MARLBOROUGH – 8535LUC – P8535LUC STOCKTON – 8570LUC – P8570LUC Model Gas Gas Working Aeration Injector Gas Rate Input kW (Gross) Country CAT. Type Pressure m 3 /h High Low 8535LUC I 2H Natural 20 mbar Ø 1 x 14.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest editon). See diagram 1.
10 1.2 REAR FLUE 8526 Terminal dimensions: 395 x 200 x 200 mm (H x W x D) Cut to length as required on site. Guard Supplied. 1.3 TOP EXIT Two types of top exit flue terminal are available, horizontal and vertical.
11 1.5 TOP FLUE UP & OUT WITH ADDITIONAL BEND Any additional bend may be used on the horizontal section (either 45° or 90°) but the overall horizontal flue run will be reduced. Refer to diagram 4. 1.6 TOP FLUE VERTICAL KIT (8524/8524AN) - ALL APPLIANCES Vertical from the top of the appliance.
12 2. VENTILATION The appliance requires no additional ventilation. 3. INSTALLATION OF THE GAS SUPPLY 3.1 Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.
13 IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, REPLACING PARTS.
14 3.1.5 To set the flue length, measure the total wall thickness, then add 65mm. This total flue length will give the minimum clearance of 50mm between the rear of the stove and the wall. To cut the flue to length using a hacksaw, first insert the square cardboard fitment into the flue.
15 INSTALLATION INSTRUCTIONS INSTALLATION 3.2 TOP EXIT 3.2.1 There are two types of top exit flues available, one with a vertical terminal, the other with a horizontal terminal. Minimum and maximum flue lengths are shown in Diagram 3 under Site Requirements, 1.
16 INSTALLATION INSTRUCTIONS INSTALLATION 3.2.6 To determine the length of the terminal flue section measure from the outside of the wall to the stop on the 90° elbow. Horizontal flue sections may fitted between the elbow and the terminal section. See diagram 7.
17 INSTALLATION INSTRUCTIONS INSTALLATION 5. FUELBED ARRANGEMENTS Remove the cast iron door using the tool provided. The main ceramic components are inside the firebox. NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING TO AVOID DAMAGING THE OUTER CASING.
5.4 Place the second ash panel to the right of the first, with the pointed end of the panel fitting into the V shape. This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports. 5.5 Place log E across from the rear of log A to log C on the right hand side.
1. COMMISSIONING 1.1 Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. Connect the gas supply to the 8mm compression elbow at the RH rear corner of the stove, see diagram 1.
20 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
21 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1.
22 SERVICING INSTRUCTIONS REPLACING PARTS 1. GENERAL 1.1 All principal components can be replaced without removing the stove from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.
23 SERVICING INSTRUCTIONS REPLACING PARTS 3.4 To remove the pilot injector, undo the compression nut on the pilot feed pipe and withdraw the injector which will be hooked onto the olive. When replacing an injector always make sure it is hooked onto the olive before inserting it into the pilot burner.
24 SERVICING INSTRUCTIONS REPLACING PARTS 4.3 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in diagram 9.
25 SERVICING INSTRUCTIONS REPLACING PARTS 8.4 Holding the injector with a spanner, undo the feed pipe. NOTE: THE ORIENTATION OF THE INJECTOR. 8.5 Reassemble in reverse order, turn on the gas supply and check for any leaks. 9. PRIMARY AERATION PLATE 9.
26 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Stovax Stockton Log Effect Stove Range c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Stovax Stockton Log Effect Stove Range - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Stovax Stockton Log Effect Stove Range, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Stovax Stockton Log Effect Stove Range va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Stovax Stockton Log Effect Stove Range, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Stovax Stockton Log Effect Stove Range.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Stovax Stockton Log Effect Stove Range. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Stovax Stockton Log Effect Stove Range ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.