Manuel d'utilisation / d'entretien du produit Gazco Ceremica Log Effect Stove Range du fabricant Stovax
Aller à la page of 24
C e r a m i c a L o g E f f e c t S t o v e R a n g e C on v en t io n al F l ue With upgradeable control valve I ns t r uc t io n s f or U se , I ns t a ll a ti o n a nd S er v i ci n g Fo r use i n G B, IE (G re at Br it ain a nd Ei re ) PR0844 Issue 1 (May 2006) I M P O R T A N T Do not attempt to burn rubbish in this fire.
2 CONTENTS COVERING THE FOLLOWING MODELS CERAMICA MANHATTAN – 8615LUC – P8615LUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Technical Specifications 8 .
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must be carried out by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, appropriate Codes of Practice and in accordance with the manufacturer’s instructions.
5 3. TURNING OFF THE STOVE 3.1 To turn the stove off, locate the control valve, turn the left- hand control knob until it points to off ( ). The main burner will go out leaving the pilot burning. 3.2 To turn the pilot off, locate the control valve, turn the right- hand control knob until it points to off ( ), the pilot will go out.
6 7.2 Place log B on the left-hand side of the burner with the location bar on the underside of the log fully located in the long slot of the burner. Make sure the log is as far to the left as possible.
7.8 Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: CERAMICA MANHATTAN – 8615LUC – P8615LUC Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country CAT. Type Pressure Class m 3 /h High Low 8615LUC I 2H Natural 20 mbar 3 Ø 14.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum effect height of the flue or chimney must be 3 metres (10ft).
10 IM P O R T A N T : E N S U R E T H A T T H E A P P L I A N C E I S C O R R E C T L Y A D J U S T E D F O R T H E G A S T Y P E A N D C A T E G O R Y A P P L I C A B L E I N T H E C O U N T R Y O F U S E . R E F E R T O D A T A B A D G E A N D T E C H N I C A L S P E C I F I C A T I O N S O F T H I S B O O K L E T .
11 3.5 Having run the gas supply to the stove, PURGE THE SUPPLY. This is essential to expel any debris that may block the gas controls. Connect the gas supply to the 8mm compression elbow at the RH rear corner of the stove, ensuring that the pipe position does not interfere with the location of the outer casing.
4. HANDLING & DISPOSAL OF FIRE CERAMICS The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.
5.8 Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer.
1. COMMISSIONING 1.1 Close all openable doors and windows in the room, ignite the stove and operate on maximum for 10 minutes. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening. See diagram 1.
15 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
16 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1.
17 SERVICING INSTRUCTIONS REPLACING PARTS 1. GENERAL 1.1 All principal components can be replaced without removing the stove from its installation, although it will be necessary to remove the door and ceramic outer casing in order to access most components.
18 SERVICING INSTRUCTIONS REPLACING PARTS NOTE: BEFORE REPLACING THE BURNER, ENSURE THE SILICONE SEAL AROUND THE INJECTOR IS INTACT AND CHECK THAT VENTURI COVER IS ATTACHED.
19 SERVICING INSTRUCTIONS REPLACING PARTS 4. IGNITION LEAD 4.1 Gain access to the back of the pilot assembly, see Section 3 above and disconnect the ignition lead from the electrode. 4.2 Undo the single screw that secures the left-hand side of the control cover, see Diagram 10.
20 SERVICING INSTRUCTIONS REPLACING PARTS 7.3 Reassemble the interrupter block and leads. Secure the thermocouple connection in the rear of the gas control (Do not overtighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks.
21 SERVICING INSTRUCTIONS REPLACING PARTS 9.5 Refit the new sensor, ensuring that the plastic spacers are between the sensor and the bracket. Refit the leads. See Diagram 20. 9.6 Feed the cable back through the hole as you replace the bracket. When the bracket is located correctly it will sit flush with the back panel without force required.
22 SERVICING INSTRUCTIONS REPLACING PARTS 12. CONTROL UPGRADE See Installation, Section 1. 13. SHORT SPARES LIST Component NG LPG G20 G30 G31 20mb 29mb 37mb Main Injector IN0045 IN0030 IN0030 Aeration.
23 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Stovax Gazco Ceremica Log Effect Stove Range c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Stovax Gazco Ceremica Log Effect Stove Range - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Stovax Gazco Ceremica Log Effect Stove Range, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Stovax Gazco Ceremica Log Effect Stove Range va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Stovax Gazco Ceremica Log Effect Stove Range, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Stovax Gazco Ceremica Log Effect Stove Range.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Stovax Gazco Ceremica Log Effect Stove Range. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Stovax Gazco Ceremica Log Effect Stove Range ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.