C l a r e n d o n & A s h d o n L o g E f f e c t S t o v e R a n g e C on v en t io n al F l ue With upgradeable control valve I ns t r uc t io n s f or U se , I ns t a ll a ti o n a nd S er v i .
2 CONTENTS COVERING THE FOLLOWING MODELS CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER .
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must be carried out by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, appropriate Codes of Practice and in accordance with the manufacturer’s instructions.
6. CLEANING THE FIRE WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL IN A COLD CONDITION. THE STOVE RETAINS ITS HEAT FOR A CONSIDERABLE TIME AFTER SHUTDOWN. NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING. 6.1 Remove the door by undoing the four dome nuts using the tool supplied and place to one side.
6 7.2 Place log B on the left-hand side of the burner with the location bar on the underside of the log fully located in the long slot of the burner. Make sure the log is as far to the left as possible.
7.8 Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country CAT.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum effect height of the flue or chimney must be 3 metres (10ft).
10 IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 11, REPLACING PARTS.
11 3.6 The flue system may now be connected to the stove. Ensure that all joints are sealed with a suitable fire resistant sealant. It is also recommended that a physical retention method be used at the flue spigot joint, self-tapping screws being favoured.
12 5.4 Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 6. 5.5 There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox.
13 6. LIGHTING 6.1 Full instructions are given in the User section under Lighting the Stove. INSTALLATION INSTRUCTIONS INSTALLATION.
1. COMMISSIONING 1.1 Close all openable doors and windows in the room, ignite the stove and operate on maximum for 10 minutes. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening by viewing through the sight hole.
15 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
16 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1.
17 SERVICING INSTRUCTIONS REPLACING PARTS 1. GENERAL 1.1 All principal components can be replaced without removing the stove from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.
18 SERVICING INSTRUCTIONS REPLACING PARTS 3.7 To remove the thermocouple, undo the retaining nut and withdraw the thermocouple. Undo the thermocouple from the back of the gas valve. See Diagrams 5 and 6. Reassemble in reverse order. Do not overtighten.
19 SERVICING INSTRUCTIONS REPLACING PARTS 6.6 Check all joints for gas leaks. Check the operation of the thermocouple and ignition lead. 7. MAGNETIC SAFETY VALVE 7.1 Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve.
20 SERVICING INSTRUCTIONS REPLACING PARTS 9.3 Undo the two screws at the back of the firebox and carefully withdraw the bracket. 9.4 Disconnect the two slender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers. See diagram 16.
21 SERVICING INSTRUCTIONS REPLACING PARTS 11. CHANGING BETWEEN GAS TYPES In order to change between gas types, it will be necessary to change the following items.
22 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Stovax 705088 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Stovax 705088 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Stovax 705088, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Stovax 705088 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Stovax 705088, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Stovax 705088.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Stovax 705088. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Stovax 705088 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.