Switch 4226T (3C17300) Switch 4250T (3C17302) Switch 4228G (3C17304)

Part No. DUA1730-0AAA04 Published July 2005

3Com Corporation 350 Campus Drive Marlborough, MA 01752-3064
Copyright © 2002, 2005 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Technologies.
3Com Technologies reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Technologies to provide notification of such revision or change.
3Com Technologies provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com, the 3Com logo and SuperStack are all registered trademarks of 3Com Corporation.
Novell and NetWare are registered trademarks of Novell Incorporated.
Adobe and Acrobat are registered trademarks of Adobe Systems Incorporated.
All other company and product names may be trademarks of the respective companies with which they are associated.
It is a 3Com policy to be environmentally friendly in all operations. This manual is printed on paper that comes from sustainable, managed European forests. The production process for making the pulp has a reduced AOX level (adsorbable organic halogen) resulting in elemental chlorine-free paper.
The paper is fully biodegradable and recyclable.
Environmental Statement


This guide provides all the information you need to install and use a SuperStack® 3 Switch 4200 in its default state.
This guide is intended for use with the following Switch 4200 Family models:
All procedures described in this guide apply to all models except where stated.
For details on the Switch 4200 26-Port (3C17300A), Switch 4200 50-Port (3C17302A) and Switch 4200 28-Port (3C17304A), refer to the following document:
available for download from the 3Com Web site, www.3Com.com.
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
If the information in the release notes that are shipped with your product differ from the information in this guide, follow the instructions in the release notes.

Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the 3Com World Wide Web site:
Conventions Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons

Table 2 Text Conventions

Table 2 Text Conventions (continued)

In addition to this guide, each Switch documentation set includes the following:
This guide contains information on the features supported by your Switch and how they can be used to optimize your network. It is supplied in PDF format on the CD-ROM that accompanies the Switch.
This guide contains:
This guide provides detailed information about the web interface and command line interface that enable you to manage the Switch. It is supplied in HTML format on the CD-ROM that accompanies the Switch.
These notes provide information about the current software release, including new features, modifications, and known problems.
There are other publications you may find useful, such as:
Related Documentation 9

The CD-ROM supplied with your Switch contains the following online documentation:
1 To access the documentation insert the CD-ROM into your CD-ROM drive. If your PC has auto-run enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
If the online documentation is to be accessed from a local drive or server, you will need to access the CD-ROM contents via the root directory and copy the files from the CD-ROM to a suitable directory.
3Com recommends that you copy the Docs/reference directory as a whole to maintain the structure of the files.

1 INTRODUCING THE SUPERSTACK 3 SWITCH 4200 FAMILY
This chapter contains introductory information about the Switch 4200 Family and how it can be used in your network. It covers summaries of hardware and software features and also the following topics:
This Getting Started Guide describes the following units in the Switch 4200 Family:
For details on the Switch 26-Port (3C17300A), Switch 50-Port (3C17302A) and Switch 28-Port (3C17304A), refer to the following document:
available for download from the 3Com Web site, www.3Com.com.

About the Switch 4200 Family The Switch 4200 Family are stackable 10/100/1000 Mbps devices which consists of:
The Switch provides high-performance workgroups with a backbone to server connection. You can also add the Switch 4200 Family to any SuperStack® system as your network grows.
Table 3 summarizes the hardware features that are supported by the Switch 4200 Family.
Table 3 Hardware features


About the Switch 4200 Series 13
Figure 1 Switch 4226T (3C17300) — front view

21 9 10 22 11 23 12 24 8 20 1 13 19 7 18 6 17 5 16 4 15 3 14 2
Figure 2 Switch 4250T (3C17302) — front view

8 32 1 25 31 7 30 6 29 5 28 4 27 3 26 2
16 40 9 33 39 15 38 14 37 13 36 12 35 11 34 10 24 48 17 41 47 23 46 22 45 21 44 20 43 19 42 18
Figure 3 Switch 4228G (3C17304) — front view

21 9 10 22 11 23 12 24 8 20 1 13 19 7 18 6 17 5 16 4 15 3 14 2

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
10BASE-T/ 100BASE-TX Ports The Switch has 24 or 48 auto-negotiating 10BASE-T/100BASE-TX ports configured as Auto MDIX (cross-over). While auto-negotiation is enabled, these ports can automatically detect whether they need to operate in MDI or MDIX mode. Alternatively, you can manually set these ports to 10BASE-T half duplex, 10BASE-T full duplex, 100BASE-TX half duplex or 100BASE-TX full duplex. The maximum segment length is 100 m (328 ft) over Category 5 twisted pair cable.
The Switch has two auto-negotiating 10/100/1000BASE-T ports configured as Auto MDIX (cross-over). While auto-negotiation is enabled, these ports can automatically detect whether they need to operate in MDI or MDIX mode. These ports provide 10/100/1000 Mbps full duplex connections to other Gigabit Ethernet devices. Full duplex allows packets to be transmitted and received simultaneously which, in effect, doubles the potential throughput of a link. These ports require either straight-through or cross-over Category 5 cables with RJ-45 connectors at both ends. The maximum UTP cable length is 100 m (328 ft) over Category 5 cable.
The 10/100/1000BASE-T ports will auto-negotiate to the appropriate speed.
GBIC Ports This section applies to the SuperStack 3 Switch 4228G only.
The two GBIC ports support Category 5 twisted pair cable and fiber Gigabit Ethernet short-wave (SX), long-wave (LX) and long-haul (LH70) GBIC transceivers in any combination. This offers you the flexibility of using GBIC transceivers to provide connectivity between the Switch and remote 1000 Mbps workgroups or to create a high capacity aggregated link backbone connection.

About the Switch 4200 Series 15
Fiber GBIC's.
The default state for these ports is auto-negotiation enabled, where speed, duplex and flow control modes are negotiated. Because the speed and duplex modes are fixed by the media type, only the flow control is negotiated with the link partner. Alternatively, auto-negotiation can be disabled and the flow control setting can be manually configured.
These ports will auto-negotiate to 1000BASE-T, full duplex only. Although it is not possible to disable auto-negotiation it is possible to change the advertised capabilities for flow control support, effectively enabling or disabling flow control.
LEDs Table 4 lists LEDs visible on the front of the Switch, and how to read their status according to color. For information on using the LEDs for problem solving, see “Solving Problems Indicated by LEDs” on page 54.
It is not possible to determine the duplex mode from the LEDs. For more detailed information, refer to the “SuperStack 3 Switch Management Interface Reference Guide” on the CD-ROM that is supplied with the Switch.
Table 4 LED behavior

Green A 100 Mbps link is present and the port is enabled.
Green flashing Packets are being transmitted/received on the port.
Yellow A 10 Mbps link is present and the port is enabled.
Yellow flashing Packets are being transmitted/received on the port.
A 10 or 100 Mbps link is present, but the port is disabled.
Green A 1000 Mbps link is present and the port is enabled.
Green flashing Packets are being transmitted/received on the port.
Green A 1000 Mbps link is present and the port is enabled.

Green flashing Packets are being transmitted/received on the port.
Yellow A 10 or 100 Mbps link is present and the port is enabled.
Yellow flashing Packets are being transmitted/received on the port.
Green / Yellow alternating
A 10, 100 or 1000 Mbps link present but disabled.
Off No link is present.
1–4 Green When the Switch forms a stack with other Switch 4200 Family units the LED indicates the position of the unit in the stack and that a link is present. Unit LED number 1 can also indicate a stand-alone Switch.
Off The Switch initialization process is not complete.
Green The Switch is powered-up and operating normally.
Green flashing The Switch is either downloading software or is initializing
(which includes running a Power On Self Test).
Yellow The Switch has failed its Power On Self Test.
Refer to Chapter 4 Solving Problems Indicated by LEDs.
Off The Switch is not receiving power or there is a fault with the Power Supply Unit.
Green flashing The Switch Alert LED has been configured via the CLI or Web
Interface to flash.
Off The Switch Alert LED has been configured via the CLI or Web Interface to be off (Default state).

About the Switch 4200 Series 17
Figure 4 Switch 4200 Family — rear view

Power Socket The Switch automatically adjusts its power setting to any supply voltage in the range 90-240 VAC.
To protect against internal power supply failure, you can use this socket to connect a Switch 4200 to a SuperStack Advanced Redundant Power System (RPS). See “Connecting a Redundant Power System” on page 25.
Console Port The console port allows you to connect a terminal and perform remote or local out-of-band management. The console port uses a standard null modem cable and is set to auto-baud, 8 data bits, no parity and 1 stop bit.

Default Settings Table 5 shows the default settings for the Switch 4200 Family:
Table 5 Default Settings

Virtual LANs (VLANs) All ports belong to the untagged Default VLAN (VLAN 1) with 802.1Q learning operational
Quality of Service (QoS) All ports prioritize NBX VoIP IP. All ports set to “best effort” for all other traffic.
If you initialize a Switch unit by selecting System > Control > Initialize in the Web interface or by entering system control initialize in the Command Line Interface, the following settings are retained to allow you to connect to and manage the Switch:

This chapter contains the information you need to install and set up the Switch 4200 Family. It covers the following topics:

Package Contents ■ Switch unit
The Switch is suited for use on a desktop, either free standing or mounted in a standard 19-inch equipment rack. Alternatively, the Switch can be mounted in a wiring closet or equipment room, as an aggregator for other Hubs and Switches. A rack-mounting kit containing two mounting brackets is supplied with the Switch.
When deciding where to position the Switch, ensure that:
If the Switch is installed in a 19-inch rack or closed assembly its local air temperature may be greater than room ambient temperature.

Rack-mounting The Switch 4200 Family are 1U high and will fit in most standard 19-inch racks.
To rack-mount your Switch:
1 Place the Switch the right way up on a hard flat surface, with the front facing towards you.
2 Locate a mounting bracket over the mounting holes on one side of the Switch, as shown in Figure 5.
Rack-mounting 21

Figure 5 Fitting a bracket for rack-mounting

3 Insert the two screws and tighten with a suitable screwdriver.
You must use the screws supplied with the mounting brackets. Damage caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws (not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Finally place a unit information label on the unit in an easily accessible position. The unit information label shows the following:
You may need this information for fault reporting purposes.

Placing Units On Top of Each Other 23
If the Switch units are free-standing, up to eight units can be placed one on top of the other. If you are mixing a variety of SuperStack® 3 Switch and Hub units, the smaller units must be positioned at the top.
If you are placing Switch units one on top of the other, you must use the self-adhesive rubber pads supplied. Apply the pads to the underside of each Switch, sticking one in the marked area at each corner. Place the Switch units on top of each other, ensuring that the pads of the upper unit line up with the recesses of the lower unit.
Stacking Units Up to four Switch 4200 Family units can be stacked together and then treated as a single manageable unit with one IP address. Any combination of Switch 4200 Family units is allowed in a single stack. The units are connected together via the 10/100/1000BASE-T ports on the front of the unit as shown in Figure 6. Starting from the base of the stack, the port marked with ‘up’ is connected to the port marked with ‘down’ on the unit above. Cable lengths of between 14 cm (5.5 in) and 100 m (328 ft) can be used for stacking.
Figure 6 Stacking example

3C17302A Superstack 3 Switch 4200 50-Port 8 32 1 25 31 7 30 6 29 5 28 4 27 3 26 2
16 40 9 33 39 15 38 14 37 13 36 12 35 11 34 10 24 48 17 41 47 23 46 22 45 21 44 20 43 19 42 18
21 9 10 22 11 23 12 24 8 20 1 13 19 7 18 6 17 5 16 4 15 3 14 2
3C17304A Superstack 3 Switch 4200 28-Port Power/ Self Test
26 / Down 25 / Up 1 2 3 4 Unit
21 9 10 22 11 23 12 24 8 20 1 13 19 7 18 6 17 5 16 4 15 3 14 2
26 / Down 25 / Up 1 2 3 4 Unit
21 9 10 22 11 23 12 24 8 20 1 13 19 7 18 6 17 5 16 4 15 3 14 2
26 / Down 25 / Up 1 2 3 4 Unit
The unit LEDs will display the unit number in the stack, from 1 at the bottom to 4 at the top.
3Com recommends that when you add a new unit to a stack, you should first initialize it to factory default settings.
Any Switch 4200 unit can be added to the stack, including the Switch 26-Port (3C17300A), the Switch 50-Port (3C17302A) and the Switch 28-Port (3C17304A). You must install the latest software version on all units in the stack.

Stack renumbering occurs when another Switch 4200 Family unit is added to the bottom of an established stack except when the stack is already 4 units high. In this instance the ‘down’ port on the bottom unit of the existing stack will be disabled and its LED will flash green. You will then not be able to use that port again until the link is lost on that port.
When another Switch 4200 Family unit is added to the top of an established stack, no stack renumbering occurs. If however the unit being added takes the stack height above 4 then the ‘up’ port on the top unit of the existing stack will be disabled and its LED will flash green. You will then not be able to use that port again until the link is lost on that port.
When removing a Switch from a stack, note the following:
If you are having problems, refer to “Solving Stack Formation Problems” on page 56.
The following sections describe how to get your Switch 4200 Family powered-up and ready for operation.
Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST), which takes approximately 10 seconds.
During the Power On Self Test, all ports on the Switch are disabled and the LEDs light in a set sequence.

The Power-up Sequence 25
When the POST has completed, check the Power On Self Test LED to make sure that your Switch is operating correctly. Table 6 shows possible colors for the LED.
Table 6 Power/Self Test LED colors

Yellow The Switch has failed its Power On Self Test.
In addition, check the Unit LEDs on all Switches in the stack. If a Unit LED is off, initialization is not complete. 3Com recommends that you do not use the Switch's management interface until the Unit LED is green.
If there is evidence of a problem, see “Solving Problems Indicated by LEDs” on page 54.
You can connect a SuperStack Advanced Redundant Power System (3C16071, 3C16071A or 3C16071B) to the Switch. This unit, which is also known as an RPS, is designed to maintain the power to your Switch if a power supply failure occurs.
For normal redundancy, the unit requires one Type 2A Power Module (part number 3C16074A). For full redundancy, the unit requires two type 2A Power Modules combined using a Type 2 Y-Cable (part number 3C16078).
All of the ports on the front of the Switch 4200 Family are Auto-MDIX, that is they have a cross-over capability. The port can automatically detect whether it needs to operate in MDI or MDIX mode. Therefore you can make a connection to a port with a straight-through (MDI) or a cross-over cable (MDIX).
The Auto-MDIX feature only operates when auto-negotiation is enabled.

If auto-negotiation is disabled, all the Switch ports are configured as MDIX (cross-over). If you want to make a connection to another MDIX port, you need a cross-over cable. Many ports on workstations and servers are configured as MDI (straight-through). If you want to make a connection to an MDI port, you need to use a standard straight-through cable. See Table 7.
3Com recommends that you use Category 5 twisted pair cable — the maximum segment length for this type of cable is 100 m (328 ft).
You can create a grounded port by connecting all wires at one end of a UTP cable to an earth ground point, and the other end to a female RJ-45 connector located, for example, on a Switch rack or patch panel. The RJ-45 connector is now a grounded port.
Table 7 Cables required to connect the Switch 4200 Family to other devices if

Choose from the following cable options:
For detailed information on fiber cable specifications, refer to the SuperStack 3 Implementation Guide that accompanies your Switch.
auto-negotiation is disabled

If you wish to connect a 1000BASE-SX MT-RJ port to a fiber port with a different type of connector, for example, SC or ST please contact your network supplier for a suitable patch cable.
GBIC Operation The following section describes how to insert a GBIC transceiver into a GBIC port. This section applies to the SuperStack 3 Switch 4228G only.
GBIC transceivers are hot-insertable and hot-swappable. You can remove them from and insert them into any GBIC port without having to power down the Switch.
The 3Com approved GBIC transceivers are:
These are correct at the time of publication.
To access the latest list of approved GBIC transceivers for the Switch on the 3Com Corporation World Wide Web site, enter this URL into your internet browser:
The URL is case sensitive.
To be recognised as valid, the GBIC transceiver must have the following characteristics:
Use this transceiver to connect the Switch directly to a multimode fiber-optic cable.
Use this transceiver to connect the Switch directly to Category 5 twisted-pair cable.
GBIC Operation 27

Use this transceiver to connect the Switch directly to a single-mode fiber-optic cable or to multimode fiber using a conditioned launch cable.
Use this transceiver to connect the Switch directly to a single-mode fiber-optic cable or to multimode fiber using a conditioned launch cable.
If the GBIC transceiver is faulty, it will not operate within the Switch. See “Solving Hardware Problems” on page 55.
Do not use non-3Com GBICs. If the GBIC transceiver is invalid it will not be recognised by the Switch.
Use the following sequence of steps to activate the GBIC ports.
1 To insert one of the transceivers into a GBIC expansion port on the Switch:
a Orient the transceiver so that the fiber-optic duplex subscriber connector (SC) is toward you, as shown in Figure 7.
b Gently slide the transceiver into the GBIC port until it clicks into place.
2 If you wish to remove the transceiver, compress the side tabs and gently pull the transceiver out of the port.

Figure 7 Inserting a GBIC Transceiver

3 The transceiver connects to the network using a duplex SC connector. Attach a male duplex SC connector on the network cable into the duplex SC connector on the transceiver.
4 Connect the other end of the cable to a device fitted with an appropriate Gigabit Ethernet connection.
5 Check the LEDs on the front of the Switch to ensure that it is operating correctly. Refer to “LEDs” on page 15 for more information.
GBIC Operation 29


Your Switch can operate in its default state, that is, you can install it and it will work straight away (plug-and-play). However, to make full use of the features offered by the Switch, and to change and monitor the way it works, you have to access the management software that resides on the Switch. This is known as managing the Switch.
Managing the Switch can help you to improve the efficiency of the Switch and therefore the overall performance of your network.
This chapter explains the initial set up of the Switch and the different methods of accessing the management software to manage a Switch. It covers the following topics:

This section gives an overview of what you need to do to get your Switch set up and ready for management when it is in its default state. The whole setup process is summarised in Figure 8. Detailed procedural steps are contained in the sections that follow. In brief, you need to:
Figure 8 Initial Switch Setup and Management Flow diagram

Plug and Play Setup Initial IP Information Setup Feature Management
How do you want to connect to the Switch?
How do you want to Manage your Switch? Page 45.

Setting Up Overview 33
IP Configuration You can use one of the following methods to allocate IP information to your Switch (essential if you wish to manage your Switch across the network).
You can choose to configure the IP information yourself. The Switch remembers the information that you enter until you change it again or set the configuration method to Automatic.
You should use the Manual IP configuration method if:
For most installations, 3Com recommends that you configure the Switch IP information manually. This makes management simpler and more reliable as it is not dependent on a DHCP or BootP server, and eliminates the risk of the IP address changing.
If you wish to manually enter IP information for your Switch, work through the “Manually Configuring IP Information” section on page 35.
By default the Switch tries to configure itself with IP information without requesting user intervention. It tries to obtain an IP address from a DHCP or BootP server on the network.
If neither server is found, the Switch will configure itself with its default IP address 169.254.100.100 if it is operating in a standalone mode, and/or no other Switches on the network have this IP address. If this default IP address is already in use on the network then the Switch detects this and configures itself with an IP address in the range 169.254.1.0 to 169.254.254.255.
This process is known as Auto-IP and is the same mechanism used by Windows 98 and Windows 2000. IP addresses configured by Auto-IP are temporary as they cannot be routed but are useful for small networks which are not connected to other networks, or for initial configuration.

However, as soon as a DHCP or BootP server is detected, the Switch will configure itself with the IP address allocated by that server.
When using automatic IP configuration it is important that the IP address of the Switch is static, otherwise you will not know what the IP address is and it will be difficult to manage. Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address will be allocated to the Switch. Refer to the documentation that accompanies your DHCP/BootP server.
For a detailed description of how automatic IP configuration operates, please refer to the Implementation Guide on the CD-ROM that accompanies your Switch or on the 3Com Web site.
You should use the automatic IP configuration method if:
If you use the automatic IP configuration method, you need to discover the automatically allocated IP information before you can begin management. Work through the “Viewing Automatically Configured IP Information” section on page 42.
Once your Switch’s initial set up is complete you can set up your chosen management method as described in “Methods of Managing a Switch” on page 45.
For detailed information about the specific web interface operations and command line interface commands and problem solving, refer to the “SuperStack 3 Switch Management Interface Reference Guide” on the CD-ROM that is supplied with the Switch or on the 3Com Web site.

Manually Configuring IP Information 35
You can manually configure the Switch IP information in the following ways:
To set up your Switch manually you can make a connection to a front panel port. You must do this whilst the Switch is offline, that is, before you connect the Switch to a network.
The procedure described in this section assumes the unit has been powered up in standalone mode and has the default IP address of 169.254.100.100.

1 Connect the workstation to a front panel port using an Ethernet cable as shown in Figure 9.
Figure 9 Connecting a workstation to the Switch via a front panel port

To connect the cable:
a Attach an RJ-45 connector at one end of the Ethernet cable to the Network Interface Card (NIC) in the workstation.
b Connect the RJ-45 connector at the other end of the cable to one of
the front panel ports on the Switch.
Do not interconnect the Switch to any other unconfigured Switch.
You need to change the IP address and subnet mask of the workstation that you have connected to the Switch. Make a note of the existing settings so you can return to them later. Change the workstation to the following settings:
You are now ready to manually set up the Switch with IP information. You can do this using the Web interface or the command line interface (CLI) via telnet.
1 Power-up the Switch. This takes approximately one minute.
2 Open a suitable Web browser and enter 169.254.100.100 in the Location Address field. This is the default IP address that is automatically assigned to an offline unit.

Manually Configuring IP Information 37
If there is no response, wait for one minute then re-enter the default IP address.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt (default user name and password). If you have logged on correctly, a set of Getting Started pages are displayed.
4 The Getting Started pages allow you to enter basic setup information for the Switch. Select Manual and then enter the IP address, subnet mask, and default gateway that you want the Switch to use when it is connected to the network. The final page displays a summary of the information entered.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 45.
Accessing the Command Line Interface via Telnet or Windows HyperTerminal using TCP/IP may not work correctly on some platforms unless it has been configured to send line feeds with carriage returns.
To set this for telnet enter set crlf when in command mode. To set this for HyperTerminal click on the Settings tab in the Properties screen, click on ASCII Setup.. and ensure that Send line ends with line feeds is checked within the ASCII Sending section. You should not configure HyperTerminal in this way if you are using a console cable to make a direct connection to the Switch.
1 To start a Telnet session to the unit, click Start in Microsoft Windows 2000/XP.
a Click Run.
b In the dialogue box that appears type the default IP address of the
c Click OK.
2 Press Enter to open a login prompt.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the

top-level menu of the command line interface is displayed as shown in the example in Figure 10.
Figure 10 Example top-level command line interface menu

Menu options: 3Com Superstack 3 Switch 4200 bridge - Administer bridge-wide parameters gettingStarted - Basic device configuration logout - Logout of the Command Line Interface physicalInterface - Administer physical interfaces protocol - Administer protocols security - Administer security system - Administer sytem-level functions trafficManagement - Administer traffic management
4 At the Select menu option prompt you can either:
5 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 45.
To set up your Switch manually you can alternatively make a connection to the console port (this example describes a local connection to the console port, rather than a remote one via a modem). You can do this whilst the Switch is offline, that is, before you connect the Switch to a network, or whilst the Switch is online, that is, connected to a network.
or

Manually Configuring IP Information 39
You can find pin-out diagrams for both cables in Appendix B on page 67.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 11.
Figure 11 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch. b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.

2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
You are now ready to manually set up the Switch with IP information using the command line interface.
1 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
2 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 12.

Manually Configuring IP Information 41
Figure 12 Example top-level command line interface menu

Menu options: 3Com Superstack 3 Switch 4200 bridge - Administer bridge-wide parameters gettingStarted - Basic device configuration logout - Logout of the Command Line Interface physicalInterface - Administer physical interfaces protocol - Administer protocols security - Administer security system - Administer sytem-level functions trafficManagement - Administer traffic management
3 At the Select menu option prompt you can either:
4 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 45.
If you do not intend to use the command line interface via the console port to manage the Switch, you can disconnect the serial cable and close the terminal emulator software.
or

If you allow the Switch to automatically configure its own IP information you need to discover and view the IP information before you can begin to manage the Switch. You can discover the IP information in two ways:
You can use the 3Com Network Supervisor application provided on the CD-ROM that accompanies your Switch to discover the automatically allocated IP information.
1 Connect your Switch to the network.
2 Power-up the Switch and wait for two minutes.
3 Launch 3Com Network Supervisor and run the Auto-discovery wizard.
3Com Network Supervisor will auto-discover the new Switch and display the IP information that has been automatically allocated to the Switch.
Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address the Switch will be given. Refer to the documentation that accompanies your DHCP or BootP server.
If your network does not have a DHCP or BootP server, the workstation running 3Com Network Supervisor must be on the same subnet as the Switch, because Auto-IP addresses are non-routable.
Alternatively, you can view the automatically configured IP information via the command line interface (CLI) through a connection to the console port. (This example describes a local connection to the console port, rather than a remote one via a modem.)
Pre-requisites

Viewing Automatically Configured IP Information 43
You can find pin-out diagrams for both cables in Appendix B on page 67.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 13.
Figure 13 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch. b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.

You are now ready to view the automatically allocated IP information using the command line interface.
1 Connect your Switch to the network using an Ethernet cable. As soon as a network connection is made the Switch begins the automatic IP configuration process.
The automatic IP configuration process usually completes within one minute.
If there is no response from a DHCP server within 30 seconds, the Auto-IP configuration mechanism attempts to allocate the default IP address 169.254.100.100. If this address is not available, it then allocates an IP address in the range of 169.254.x.y (where x is in the range 1 to 254, and y is in the range 0 to 255).
2 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 14.
Figure 14 Example top-level command line interface menu

Menu options: 3Com Superstack 3 Switch 4200 bridge - Administer bridge-wide parameters gettingStarted - Basic device configuration logout - Logout of the Command Line Interface physicalInterface - Administer physical interfaces protocol - Administer protocols security - Administer security system - Administer sytem-level functions trafficManagement - Administer traffic management
4 At the Select menu option prompt enter the protocol ip interface summary command. At the Select IP interfaces

Methods of Managing a Switch 45
prompt enter all. A summary of the automatically allocated IP information is displayed. Make a note of the Network IP Address.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 45.
If you do not intend to use the command line interface via the console port to manage the Switch, you can disconnect the serial cable and close the terminal emulator software.
Once you have completed the initial set up of your Switch, you can decide how you wish to manage the Switch. You can use one of the following methods:
Each Switch has a command line interface (CLI) that allows you to manage the Switch from a workstation, either locally via a console port connection (see Figure 15), or remotely over the network (see Figure 16).

Figure 15 CLI management via the console port

Figure 16 CLI management over the network

Refer to “Setting Up Command Line Interface Management” on page 47.
Each Switch has an internal set of web pages that allow you to manage the Switch using a Web browser remotely over an IP network (see Figure 17).
Figure 17 Web interface management over the network
via web browser Switch Workstation
Refer to “Setting Up Web Interface Management” on page 48.
SNMP Management You can manage a Switch using any network management workstation running the Simple Network Management Protocol (SNMP) as shown in Figure 18. For example, you can use the 3Com Network Supervisor software that is provided on the CD-ROM that accompanies your Switch.
Connect over Network

Setting Up Command Line Interface Management 47
Figure 18 SNMP management over the network

Refer to “Setting Up SNMP Management” on page 49.
This section describes how you can set up command line interface management using a local console port connection or over the network.
To manage a Switch using the command line interface via the local console port connection:
1 Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 38.
2 Your Switch is now ready to continue being managed and/or configured through the CLI via its console port.
To manage a Switch using the command line interface over a network using Telnet:
1 Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 32.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.

4 To open a Telnet session via the DOS prompt, enter the IP address of the Switch that you wish to manage in the following format:
>telnet xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If opening a Telnet session via third party software you will need to enter the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
If the login prompt does not display immediately, press Return a few times until it starts.
6 If you have logged on correctly, the top-level menu of the command line interface for the Switch you wish to manage is displayed as shown in Figure 12 on page 41.
This section describes how you can set up web interface management over the network.
Pre-requisites ■ Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 32.
To display the web interface correctly, use one of the following Web browser and platform combinations:
Table 8 Supported Web Browsers and Platforms


Setting Up SNMP Management 49
For the browser to operate the web interface correctly, JavaScript™ and Cascading Style Sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings.
To manage a Switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
3 Open your web browser and enter the IP address of the Switch that you wish to manage in the URL locator, for example, in the following format:
4 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
5 Click on the Device View button to display the web management options.
Any network management application running the Simple Network Management Protocol (SNMP) can manage a Switch if:
You can use the 3Com Network Supervisor application that is provided on the CD-ROM that accompanies your Switch to provide SNMP management for your Switch. If you use 3Com Network Supervisor it automatically loads the correct MIBs and necessary files onto your workstation.

Pre-requisites ■ Documentation supplied with the SNMP network management application software.
To manage your Switch using an SNMP network management application, you need to specify SNMP community strings for the users defined on the Switch. You can do this using the command line interface system management snmp community command — refer to the command line interface section of the “SuperStack 3 Switch Management Interface Reference Guide” for more information.
If you intend to manage the Switch using the web interface or the command line interface, or to change the default passwords, you need to log in with a valid user name and password. The Switch has three default user names, and each user name has a different password and level of access. These default users are listed in Table 9.
Table 9 Default Users

monitor monitor monitor — the user can view all manageable parameters, except special/security features, but cannot change any manageable parameters.
manager manager manager — the user can access and change the operational parameters but not special/security features
security — the user can access and change all manageable parameters
Use the admin default user name (no password) to login and carry out initial Switch setup.
You can change the default passwords using either:

Default Users and Passwords 51
For more information about default users and passwords, refer to the “Superstack 3 Switch Management Interface Reference Guide” on the Switch CD-ROM.


This chapter helps you to diagnose and solve problems you may have with the operation of your Switch. There is also an explanation of IP addressing.
The topics covered are:
If you experience a problem that is not listed here, it may be included in the support section of the SuperStack 3 Switch Management Interface Reference Guide on the CD-ROM that accompanies your Switch.
For Technical Support information, see Appendix D.

Solving Problems Indicated by LEDs
If the LEDs on the Switch indicate a problem, refer to the list of suggested solutions below.
Check that the power cable is firmly connected to the Switch and to the supply outlet. If the connection is secure and there is still no power, you may have a faulty power cord or an internal fault. Firstly, check the power cord by:
then contact your supplier for advice.
The Switch unit has failed its Power On Self Test (POST) because of an internal problem. If a port has failed it’s POST, it’s LED will flash green/yellow alternately to indicate that the port is disabled. Contact your supplier for advice.
A link is connected and yet the Status LED for the port does not light
Check that:
Auto-negotiation problems will occur with all ports where auto-negotiation is disabled and incorrect cables are being used (cross-over or straight).

Solving Hardware Problems 55
SNMP fan fail trap hardware failure
In the rare event of your Switch unit experiencing an SNMP fan fail trap hardware failure, refer to the suggested solution below.
1 Power off the unit.
2 Check that the air vents are not obstructed.
3 Power cycle the unit. To do this, remove and reconnect all power supplies.
4 If a further fan fail trap is received, return the unit.
The Switch has identified that the GBIC does not meet the minimum requirements for the Switch and has disabled the port. To correct this problem, completely remove the GBIC and replace it with a 3Com approved GBIC. See “Approved GBIC Transceivers”on page 27.
To correct this problem, completely remove the GBIC and then reinsert it. If the problem persists, contact 3Com Technical Support.
If you experience communication problems with the Switch, ensure that:
The following is a brief overview of IP addressing, and how to obtain a registered IP address.
To be managed correctly, each device on your network (for example a Switch or Hub) must have a unique IP address. IP addresses have the format n.n.n.n where n is a decimal number between 0 and 255. An example IP address is 192.168.100.8.

The IP address is split into two parts:
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you access the Internet, you must apply for a registered IP address.
The IP registration system ensures that every IP address used is unique; if you do not have a registered IP address, you may be using an identical address to someone else and your network will not operate correctly.
InterNIC Registration Services is the organization responsible for supplying registered IP addresses. The following contact information is correct at time of publication:
If your IP network is internal to your organization only, that is, you do not access the Internet, you may use any arbitrary IP address as long as it is not being used by another device on your network. 3Com suggests you use addresses in the series 192.160.100.X (where X is a number between 1 and 254) with a subnet mask of 255.255.255.0.
These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
If you are having problems with correctly forming a stack, first ensure that Spanning Tree is enabled. If it is enabled, do the following:
1 Power off all units in the stack.
2 Check all the cable connections in the stack.
3 Power on all units in the stack.

Solving Software Upgrade Problems 57
You can upgrade the management software of the Switch by using the System > Control > Software Upgrade operation in the Web Interface, or the system control softwareUpgrade command in the command line interface. For details on these options, refer to the Management Interface Reference Guide supplied in HTML format on the CD-ROM that accompanies your Switch.
If you have problems with your software upgrade, refer to the Problem Solving section in the Management Interface Reference Guide.


You must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the Switch 4200 Series.

Important Safety Information
U.S.A. and Canada
Europe only: ■ The supply plug must comply with CEE 7/7 (“SCHUKO”).
Denmark ■ The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland ■ The supply plug must comply with SEV/ASE 1011.
United Kingdom only

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.

Null Modem Cable 9-pin to RS-232 25-pin

PC-AT Serial Cable 9-pin to 9-pin


Modem Cable 9-pin to RS-232 25-pin

Pin assignments for ports configured as MDI and MDIX are given in Table 10 and Table 11.
Table 10 Pin assignments


RJ-45 Pin Assignments 69
Table 11 Pin assignments



Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 2.4 kg (5.3 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Operating Humidity 10–95% relative humidity, non-condensing
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL 60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, VCCI Class A, CNS 13438 Class A,
Heat Dissipation 40 watts maximum (136 Btu/h maximum)
AC Line Frequency 50/60 Hz
Input Voltage 90–240 VAC
Current Rating 2.3 A (amps)(maximum)



Switch 4250T (3C17302) 73

Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 2.83 kg (6.23 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, VCCI Class A, CNS 13438 Class A,
Switch 4250T (3C17302)


Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 2.73 kg (6.00 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, VCCI Class A, CNS 13438 Class A,
Switch 4228G (3C17304)

Warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you.
Warranty and other service benefits are enabled through product registration. Register your product at http://eSupport.3com.com/. 3Com eSupport services are based on accounts that you create or have authorization to access. First time users must apply for a user name and password that provides access to a number of eSupport features including Product Registration, Repair Services, and Service Request. If you have trouble registering your product, please contact 3Com Global Services for assistance.
To enhance response times or extend warranty benefits, contact 3Com or your authorized 3Com reseller. Value-added services like 3Com ExpressSM and GuardianSM can include 24x7 telephone technical support, software upgrades, onsite assistance or advance hardware replacement. Experienced engineers are available to manage your installation with minimal disruption to your network. Expert assessment and implementation services are offered to fill resource gaps and ensure the success of your networking projects. More information on 3Com maintenance and Professional Services is available at http://www.3com.com/
Contact your authorized 3Com reseller or 3Com for a complete list of the value-added services available in your area.

You will find support tools posted on the 3Com web site at http://www.3com.com/
3Com Knowledgebase helps you troubleshoot 3Com products. This query-based interactive tool is located at http://knowledgebase.3com.com and contains thousands of technical solutions written by 3Com support engineers.
Software Updates are the bug fix / maintenance releases for the version of software initially purchased with the product. In order to access these Software Updates you must first register your product on the 3Com web site at http://eSupport.3com.com/
First time users will need to apply for a user name and password. A link to software downloads can be found at http://eSupport.3com.com/, or under the Product Support heading at http://www.3com.com/
Software Upgrades are the feature releases that follow the software version included with your original product. In order to access upgrades and related documentation you must first purchase a service contract from 3Com or your reseller.
To enable telephone support and other service benefits, you must first register your product at http://eSupport.3com.com/
Warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you.
When you contact 3Com for assistance, please have the following information ready:

To send a product directly to 3Com for repair, you must first obtain a return authorization number (RMA). Products sent to 3Com, without authorization numbers clearly marked on the outside of the package, will be returned to the sender unopened, at the sender’s expense. If your product is registered and under warranty, you can obtain an RMA number online at http://eSupport.3com.com/. First time users will need to apply for a user name and password.
Contact Us 3Com offers telephone, e-mail and internet access to technical support and repair services. To access these services for your region, use the appropriate telephone number, URL or e-mail address from the list below.
Telephone numbers are correct at the time of publication. Find a current directory of contact information posted on the 3Com web site at http://csoweb4.3com.com/contactus/

1 800 678 515 800 933 486 +61 2 9424 5179 or 000800 650 1111 001 803 61009 00531 616 439 or 03 3507 5984 1800 801 777 0800 446 398 +61 2 9937 5083
1235 61 266 2602 or 1800 1 888 9469 800 810 3033 800 6161 463 080 333 3308 00801 611 261 001 800 611 2000
You can also obtain support in this region using the following e-mail: apr_technical_support@3com.com
Or request a repair authorization number (RMA) by fax using this number: + 65 543 6348
Europe, Middle East, and Africa Telephone Technical Support and Repair
From the following countries, you may use the numbers shown:
Contact Us 77

Country Telephone Number Country Telephone Number
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
0800 297 468 0800 71429 800 17309 0800 113153 0800 917959 0800 182 1502 06800 12813 1 800 553 117 1800 945 3794 800 879489
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
800 23625 0800 0227788 800 11376 00800 441-1 357 800 831416 0800 995 014 900 938 919 020 795 482 0800 553 072 0800 096 3266
You can also obtain support in this region using the following URL: http://emea.3com.com/support/email.html
Latin America Telephone Technical Support and Repair
Antigua Barbuda Argentina Local Number Argentina Argentina Aruba Bahamas Barbados Belize Bermuda Bolivia Brazil Local Number Brazil British Virgin Islands Cayman Islands Chile Columbia Local Number Colombia Costa Rica Curacao Dominica Dominique Equador El Salvador French Guinea Grenada
AT&T +800 988 2112 54 11 5556 3200 0 810 444 3COM 810 44 32 66 AT&T +1 800 998 2112 1 800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 55 11 5643 2700 800 13 266 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 592 5000 800 011 3266 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guadalupe Guatemala Guyana Haiti Honduras Jamaica Mexico Local Number Mexico Mexico Monserrat Nicaragua Panama Paraguay Peru Puerto Rico Saba Anquila St Kitts Neives St Lucia St Vincent Suriname Trinidad and Tobago Turks and Caycos Uruguay - Montevideo Venezuela Virgin Islands
AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 52 55 52 01 00 04 01 800 849CARE 01 800 849 2273 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
You can also obtain support in this region using the following:
English speakers in Latin America should send e-mail to: lat_support_anc@3com.com


Contact Us 79


FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
INFORMATION TO THE USER If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.
CSA STATEMENT This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
CE STATEMENT (EUROPE) This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC.


Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.