Manuel d'utilisation / d'entretien du produit iFBZ du fabricant Schneider Electric
Aller à la page of 22
.
.
The world's first EOCR with built-in ZCT (bottom hole & terminal type) will save space, time and wiring through unique development design during installation. with compact size, possible to be applied to various panel size. the protection function added for high groud fault current.
Applications Building Office, commercial business, residence, school, hospital Industrial facilities Petrochemical, electronic, glass, steel, semiconductor, chemical, medicine, cement, paint.
Public institutions Gas, water supply and drainage, airport, train, port Control power ● 24 VDC ● 85~260 VAC/DC, 50/60 Hz Composition by function ● Earth Fault ● i3BZ, iFBZ (with Modbus RS-485.
6 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in Z.
7 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Item Operating Condition & Setting Range Operation Time Over Current (oc) Load current(In) exceeds threshold(Is) Definite(Def) : 0.
8 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over Current Rated Setting Range(A) Definite TCC : 0.
9 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Time-current characteristic cur ve 2. Definite characteristic 3.
10 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over current and time setting tips ● Over current Setting tips in definite TCC mode 1.
11 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Front face 3 phase currents (In) and the leakage current are displayed every 2 seconds in sequence.
12 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in .
1 Password 2 Selection of Phase 3 TCC Selection 4 Frequency 5 Fail Safe Reversed Phase 6 detection 7 Over Current Threshold 8 Start Delay Time 9 Over Current Duration Under Current 10 Threshold Under .
Threshold of Alert output, set by % of the over current threshold (oc). If the load current is higher than this value, alert output(07-08 contact) is energized according to the setting of “ ALo:XX ” . If the load current is detected, alert output(07-08 contact) is energized.
15 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in .
16 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in .
17 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Dimensions EOCR-i3BZ / 3BZ2 (Bottom Hole) EOCR-i3BZ / 3BZ2 (Teminal Type) 70 95 82 ∅ 4.
18 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in .
19 Communication setting value Please set the Modbus communication parameters by PCON or HMI for the communication. Slave address Baud rate Parity Communication loss timeout Slave address The EOCR has slave addresses from 1 to 247. The factory default setting is 1.
20 Communication Guide The standard connection conforms to the Modbus specifications, sepecially 2 wire multidrop serial bus diagram, presented at the website of Modbus.org in 2002 (Modbus_over_serial_line_V1.pdf, Nov.2002). Simple wiring diagram is like below.
21 Communication Guide Bus connection thr ough a SCA type junction box 1. Master (PLC, PC or communication module) 2. Modbus cable (It is different according to the master side or a master having polarization combined to the other part of Bus) 3. Junction box 4.
Built_in ZCT catalog_EN ⓒ 2009 Samwha EOCR Ltd.-All rights reserved. 04/2009 Head Office 6 th floor, Jeil Bldg., 94-46, Youngdeungpo-Dong 7Ka, Youngdeungpo-Ku, Seoul, Korea Tel. 82 2 3473 2340 / Fax 82 2 3473 1159 Iksan Plant 574, Yongie-dong, Iksan-shi, Junbuk, Korea Tel.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Schneider Electric iFBZ c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Schneider Electric iFBZ - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Schneider Electric iFBZ, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Schneider Electric iFBZ va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Schneider Electric iFBZ, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Schneider Electric iFBZ.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Schneider Electric iFBZ. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Schneider Electric iFBZ ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.