FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC, Canada V4G 1H4 918-408 W ARNING: Improper installation, adjustment, alteration, service or main- tenance can cause injury , property damage, or loss of life. Refer to this manual.
2 E33 FPI Direct V ent Gas Insert FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FPI. The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch.
3 E33 FPI Direct V ent Gas Insert T ABLE OF CONTENTS FPI GAS FIREPLACE INSERT OPERA TING INSTRUCTIONS First Fire ........................................................................ 18 Operating Instructions .......................................
4 E33 FPI Direct V ent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.
5 E33 FPI Direct V ent Gas Insert IMPORT ANT : SA VE THESE INSTRUCTIONS The FPI Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdic- tion to determine the need for a permit prior to starting the installation.
6 E33 FPI Direct V ent Gas Insert 14) Install optional Excalibur Surround. See page 15. 15) Install optional remote control or wall ther- mostat, pages 17. 16) Final check (page 18): Before leaving this unit with the customer , the installer must ensure that the appliance is fi ring correctly .
7 E33 FPI Direct V ent Gas Insert MINIMUM CLEARANCES T O COMBUSTIBLES From Unit Side W alls * A 8" (203 mm) Ceiling B 47" (1 194 mm) Min. Mantel Height C 15" (381 mm) Max.
8 E33 FPI Direct V ent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
9 E33 FPI Direct V ent Gas Insert OPTIONAL BRICK P ANEL Optional Brick Panel Set: Part # Description Qty T op (brick) panel 1 Back (brick) panel 1 Left (brick) panel 1 Right (brick)panel 1 340-043 T o.
10 E33 FPI Direct V ent Gas Insert T op Bracket 5) Place the top bracket onto the top edge of the top panel (refer to Diagram 2). Diagram 2 6) Slide the top panel and bracket assembly carefully onto the baffl e plate ensuring the panel is centered. Make sure the tabs of the top bracket fi t into the baffl e openings (refer to Diagram 3).
11 E33 FPI Direct V ent Gas Insert INST ALLA TION 5) Re-install the grate (reverse step 3). 6) Line up the pin holes (located at the bottom of log 03-23 ) to the pins of the rear log sup- port and position them into place.
12 E33 FPI Direct V ent Gas Insert INST ALLA TION Final Installation 03-19 E33 CONVERSION KIT FROM NG T O LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty .
13 E33 FPI Direct V ent Gas Insert Diagram 4 INST ALLA TION 9) Attach the trim to the faceplate by using the plated screws (refer to Diagram 4). Rear V iew: Faceplate Assembly Diagram 1 F ACEPLA TE & TRIM INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch.
14 E33 FPI Direct V ent Gas Insert INST ALLA TION Diagram 5 11 ) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate. The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (Diagram 1 and 2).
15 E33 FPI Direct V ent Gas Insert 1) Align the left side Faceplate T rim Bracket with the Firebox Flange and secure using 2 screws as shown in diagram 1.
16 E33 FPI Direct V ent Gas Insert INST ALLA TION 1) Remove the rivets from the surround by pulling off the hoseclamp (located at the backside of surround) with a screwdriver or plyer . Re-install the rivets by putting them through the holes on the sides of the sur- round.
17 E33 FPI Direct V ent Gas Insert WIRING DIAGRAM INST ALLA TION This heater does not require a 120V A.C. supply for operation. However , a 120V A.C. power sup- ply is needed for the fan/blower operation.
18 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS 2) T urn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. 3) Turn gas control knob counterclockwise so indicator points to the "PILOT" position.
19 E33 FPI Direct V ent Gas Insert OPERA TING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLA TE AUT OMA TIC CONVECTION F AN OPERA TION The fan operates automatically . T urn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature.
20 E33 FPI Direct V ent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements.
21 E33 FPI Direct V ent Gas Insert MAINTENANCE F AN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the fl oor of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place.
22 E33 FPI Direct V ent Gas Insert MAINTENANCE 11 ) Disconnect the inlet gas line. 12) Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve. 13) Remove the 17 screws on the valve tray . 14) T ake out the valve tray from the unit.
23 E33 FPI Direct V ent Gas Insert P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 12.
24 E33 FPI Direct V ent Gas Insert P ARTS LIST BURNER & LOG ASSEMBL Y Part # Description 52) 340-104 Gasket - V alve Tray 340-574/P V alve Assembly - NG 340-576/P V alve Assembly - LP 56) 910-190 Piezo Ignitor and Nut 57) 910-378 V alve - S.I.T . - Natural Gas 910-380 V alve - S.
25 E33 FPI Direct V ent Gas Insert 83 84 85 86 87 88 88 88 88 89 90 90 FULL SCREEN FRONT INST ALLA TION Part # Description P ARTS LIST 83) T op Frame 84) 340-910 Full Screen Door - Black 85) Full Scre.
26 E33 FPI Direct V ent Gas Insert P ARTS LIST F ACEPLA TES, TRIMS AND HEARTHS Part # Description Part # Description 340-918 Fa ceplates and T rim (Complete) with Black Tr i m 340-919 Oversized Facepl.
27 E33 FPI Direct V ent Gas Insert NOTES.
28 E33 FPI Direct V ent Gas Insert NOTES.
29 E33 FPI Direct V ent Gas Insert NOTES.
30 E33 FPI Direct V ent Gas Insert.
31 E33 FPI Direct V ent Gas Insert W ARRANTY FPI Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd.
32 E33 FPI Direct V ent Gas Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ______________________________________.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Regency E33-NG c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Regency E33-NG - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Regency E33-NG, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Regency E33-NG va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Regency E33-NG, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Regency E33-NG.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Regency E33-NG. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Regency E33-NG ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.