Manuel d'utilisation / d'entretien du produit 32198A du fabricant Quadra-Fire
Aller à la page of 40
O - T L Tested and Listed by Beaverton Oregon USA OMNI-Test Laboratories, Inc. C P ar t No . 32198A F ebruar y 15, 2002 SA VE THESE INSTR UCTIONS 1445 N.
Page 2 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R NO TES My new Cape Cod wood sto ve .... SERIAL NUMBER: D A TE PURCHASED: DEALERSHIP: DEALER PHONE #: ADDITIONAL INF.
Page 3 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R WELCOME ______________________ Group Vice President _______________________ Controller _______________________ Manu.
Page 4 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R T ABLE OF CONTENTS LISTINGS ............................................................5 SERIAL LABEL & LOCA TON ..........................6 DIMENSIONS .........
Page 5 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R LISTINGS These installation instructions describe the installation and operation of the Cape Cod woodsto ve. This stove meets the U.S. En vironmental Protection Agency’ s 1990 particulate emission standards.
Page 6 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R LABEL LOCA TION: B A CK OF ST O VE SAFETY LABEL M IN IM U M C LE A R A N C ES T O C O MB U S TI B LE MA TE R IALS :.
Page 7 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R a ccessor y p ar ts DIMENSIONS FR ONT VIEW SIDE VIEW 26-1/2 27" 27-1/2" 8-1/4" 29" 16" 29-.
Page 8 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CLEARANCES MINIMUM CLEARANCES T O COMBUSTIBLES (In inches and millimeters.) FIGURES 1, 2 & 3 FIGURE 1 FIGURE 2 FIGURE 3 * W ith 52" high x 42" wide wall protection spaced 1" from comb ustible surface.
Page 9 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R (In inches and millimeters) FIGURE 4 In a Masonry Fireplace OR Through the W all: Six inch (6") diameter listed double wall air insulated connector pipe with listed factory-b uilt Class “A” chimney or a masonry chimney .
Page 10 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CLEARANCES FIGURE 5A NO TE: Additional oor protection is required on rear v ent installations. For this type of installation the oor protector must e xtend the length of the ue and 2" to each side of the ue.
Page 11 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R The Cape Cod has sev eral options av ailable for installation and appearance.
Page 12 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R A masonry chimney or a factory-built chimne y must be the required height abov e the roof and any other nearby obstructions.
Page 13 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R There are two separate and different parts to a ue system: the chimney connector and the chimney itself. A. Single wall connector or stovepipe. This must be at least 24 gauge mild steel or 26 g auge blue steel.
Page 14 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION MASONR Y CHIMNEY For optimal performance, masonry chimneys used to vent this appliance should be lined with a 6" stainless steel liner .
Page 15 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FIGURE 9 FIGURE 8 INST ALLA TION EIGHT INCH SOLID P A CK CHIMNEY WITH MET AL SUPPOR TS AS A THIMBLE FLOOR PROTECTO.
Page 16 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R First, make the frame for the thimble, ensuring it is no smaller than 14" square, to maintain a 2" air space around the chimney section. Attach the wall spacer to the chimne y side of the frame.
Page 17 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION FIGURE 10 MASONR Y CHIMNEY , CONT . Chimney Flue Liner Fireclay Liner or Equivalent Masonry Chimney Constructed to NFP A 21 1 Wa ll Spacer Wall Band Trim Collar Chimney Connector 1" (25mm) Air Space to Chimney Section Min.
Page 18 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O A MASONR Y FIREPLA CE There are se veral kits a vailable to connect the sto ve to a masonry replace. Look for a listed kit. The kit is an adapter which is installed at the location of the replace damper .
Page 19 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O A MET AL PREF ABRICA TED CHIMNEY When a metal prefabricated chimney is used, the manufacturer’ s installation instructions must be follo wed precisely .
Page 20 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION CONNECTION T O AN INTERIOR MET AL PREF ABRICA TED CHIMNEY IMPOR T ANT ! FOLLO W THE MANUF A CTURERS’ INST ALLA TION INSTR UCTIONS AND MAINT AIN CLEARANCES AS SPECIFIED ON P A GES 8, 9 & 10.
Page 21 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FIGURE 15 INST ALLA TION CONNECTION T O AN EXTERIOR MET AL PREF ABRICA TED CHIMNEY FIGURE 16 Floor Protector Chimn.
Page 22 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION MOBILE HOME INST ALLA TION W ARNING: NEVER DRA W COMBUSTION AIR FROM A W ALL, FLOOR OR CEILING CA VITY OR FROM ANY ENCLOSED SP A CE SUCH AS AN A TTIC OR GARA GE.
Page 23 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION ASSEMBL Y 1 Place the unit in a location near the nal installation area and follo w the procedures below: 2 Open the stove and remov e all the parts and articles packed inside.
Page 24 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION OUTSIDE AIR KIT INST ALLA TION 1. R e m o ve a l l m a t e r i a l s f r o m p a c k i n g bo x.
Page 25 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R INST ALLA TION BLO WER INST ALLA TION & OPERA TION ADJUSTING THE BLO WER SPEED CONTR OL, IF NECESSAR Y* NO TE : When the speed control is tur ned cloc kwise, it will click on to high speed.
Page 26 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION PRE-USE CHECK Use the following checklist as a guide to ensure a correct and complete installation: All safety warnings hav e been read and fol- lo wed. Floor protection requirements hav e been met.
Page 27 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION W OOD SELECTION AND ST ORA GE W ARNING ! DO NO T LEA VE THE FIRE UN A T - TENDED WHEN THE DOOR IS UNLA TCHED OR WHEN USING FIRESCREEN. CARELESSL Y PLA CED FIREWOOD COULD F ALL OUT OF THE FIREBO X CREA TING A FIRE HAZARD T O Y OUR HOME.
Page 28 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OP A CITY : This helps to determine ho w cleanly your stove is burning. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney , and 0% opacity means that no smoke column can be seen.
Page 29 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION OPERA TING TIPS H er e a r e a f ew t ip s o n o p er a ti n g y ou r C a pe Co d s t ove t o o b ta i n m ax i mu m e ffic ie ncy w it h l owe s t emissions: 1.
Page 30 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R OPERA TION BUILDING A FIRE B e f o r e l i g h t i n g y o u r fir s t fi re i n t h e s t ov e , make certain tha.
Page 31 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R ASH REMO V AL The Cape Cod is equipped with an ash remov al system. W e recommend emptying the ash pan at least once a week when the stov e is in constant operation.
Page 32 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R CHIMNEY CLEANING 1. Remov e all ash from the rebox and extinguish all hot embers before disposal. Allow the stov e to cool completely . 2. Remov e the hotplate as follows: a.
Page 33 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R MAINTENANCE CHIMNEY CLEANING, CONT . V iew of bafes after remo val of griddle and kao wool. CA UTION! T h e ba ffl e a n d k ao w oo l b l a n ke t p l a c em e n t i s crucial to the optimum perf ormance of the Cape Cod.
Page 34 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R NO TE: Remove all labels from glass prior to lighting the rst re. GLASS CARE & REPLA CEMENT 1. Ensure that the re is out and the appliance is cool to the touch.
Page 35 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R KA O WOOL INSULA TING BAFFLE BLANKET 832-3390 DOOR & GASKET Periodically check the door g asket for proper seal.
Page 36 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R TR OUBLE- SHOO TING DRAFT PROBLEMS The Cape Cod woodstov e requires a minimum ue draft of .10 inches of water column on High, and .04 inches of w ater column on Lo w , as measured with a draft meter .
Page 37 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R FLUE DRAFT A proper amount of f lu e draft is required to assure the safe and efcient operation of the Cape Cod woodstov e. Flue draft is measured as negati ve pressure in the chimney .
Page 38 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R P AR T NO. DESCRIPTION 20637B Door Gasketing only 32084 Door Cam latch only 834-3850 Complete Door Handle Assembly (includes: cam latch, gasketing; porcelain black handle; screw adapter and gold door handle).
Page 39 32198A F ebr uary 15, 2002 32198A F ebr uary 15, 2002 Cape Cod W ood Sto ve R W ARRANTY LIMITED LIFETIME WARRANTY The Aladdin Hearth Products limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Aladdin Hearth Products will repair or replace them.
32198A F ebruary 15, 2002 Cape Cod W oodstove A TTENTION INST ALLER: PLEASE RETURN THESE INSTR UCTIONS T O THE ST O VE O WNER WHEN INST ALLA TION IS COMPLETED.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Quadra-Fire 32198A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Quadra-Fire 32198A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Quadra-Fire 32198A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Quadra-Fire 32198A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Quadra-Fire 32198A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Quadra-Fire 32198A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Quadra-Fire 32198A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Quadra-Fire 32198A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.