Thank you for selecting a Powermate ® Generator. The Powermate ® generator has been made to supply reliable, portable electrical power when utility power is not available. We hope you will enjoy your new generator.
Merci d'avoir choisi le groupe électrogène Powermate ®. Ce groupe électrogène Powermate ® a été conçu pour fournir le pouvoir électrique, portatif et fiable quand le pouvoir d'utilité n'est pas disponible. Nous espérons que votre groupe électrogène vous donnera entière satisfaction.
Gracias por seleccionar un generador Powermate ®. El generador Powermate ® ha sido diseñado para proporcionar energía eléctrica confiable y portátil cuando no hay servicio disponible de energía pública. Esperamos que disfrute de su nuevo generador.
1-800-445-1805 1-308-237-2181 Fax 1-308-234-4187 www.powermate.com
4970 Airport Road P. O. Box 6001 Kearney, NE 68848

E. Idle Control Switch The Idle Control circuit is designed to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a “No Load” condition. The noise is also greatly reduced during this condition.
* 22 HP Subaru OHV engine * Cast-iron cylinder sleeve * Low oil sensor * Receptacles on control panel * Electric Start * Idle control * CordKeeper™ * 8 gallon plastic fuel tank * Portability Kit
When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition. Likewise, when the load is removed, the generator will automatically return to the idle condition after a 4-5 second delay.
A convenient switch is mounted in the control panel for easy access and will disable the Idle Control circuitry when in the off position.
A. 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements)

F. CordKeeper™ Restraint The CordKeeper™ restraint is a unique feature used to prevent plugs from being pulled out of the receptacles.
This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc.
Refer to the appropriate diagram for proper connection of power cord wires to the plug terminals.
The GFCI receptacle cannot be reset once tripped, unless the generator is running and power is available to it. Test regularly to assure proper operation.
B. 120 Volt, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.
C. 120/240 Volt Heavy Duty Receptacle This receptacle is rated at 50 amps but the current must be limited to the nameplate rating. If this receptacle is used along with the 120 volt receptacles, the total load drawn must not exceed the nameplate ratings.
D. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
120 Volt 30 Amp Plug

120/240 Volt Heavy Duty Plug

The generator is equipped with electric start. An “Off-On- Start” rotary key switch is provided on the recoil end panel. All necessary wiring is provided. The battery is provided. See engine manual for wiring diagram (3A Charge Coil), and additional information.
Connect the red 8 ga. battery lead to the positive (+) battery post and the black 8 ga. battery to the negative (-) battery post with the bolts and nuts provided.
The charging system of the unit is supplied by the starter/alternator of the engine. 12 volts DC is constantly charging the battery when the unit is running . Disconnecting the battery will stop the charging of the battery.

Before charging a storage battery, check the electrolyte fluid level in all the cells. (Sealed batteries do not require checking). Add distilled water to each cell if necessary, to bring the level back up to the manufacturer’s required level.
Item Description Qty. A. *Bolt, 1/4-20 X 8” 2 B. *Washer 1/4 2 C. *Spacer 2 D. Hold Down bar (P/N 0036525.02) 1 E. *Nyloc nut, 1/4-20 2
Powermate Corporation recommends a 12 V battery with at least 235 cranking amps, Model U1L, Lawn and Garden Battery.
* These are standard parts available at your local hardware store.

TOOLS REQUIRED: Hammer, 1/2” wrench, ratchet with a 1/2” socket, and wood blocks. Refer to the drawing for proper alignment of Foot bracket and Wheel brackets. Refer to the parts list on pages 15 and 16.
Wheel Bracket & Wheel Installation
1. Block up end of generator, about 8” high, opposite the fuel tank cap to install wheels and wheel bracket assy. 2. Add 5/16 washer (item 29) to the 1 3/4” bolts (item 71) and insert bolts/washers through the holes located in the base pan of the carrier. 3. Place the wheel bracket (item 65) through the bolts and add a 5/16 nyloc nut (item 27) and tighten securely. (On the bottom side of the pan in-between the holes will be a 1” square brace, the wheel bracket will set on this brace). 4. Add wheel spacer (item 70) to the axle. 5. Slide the wheel (item 64) onto the axle until it is snug against the spacer. The wheel is on correctly if there is approximately a 1/2” gap between the carrier tubing and the side of the wheel. If it is less then 1/2” from the carrier, turn the wheel over and reinstall. Align the wheels parallel to the carrier tubing and tighten nuts securly. To align correctly, the bolts holding the wheel bracket may have to be loosened. 6. With a hammer, add the plastic cap (item 69) on end of axle. 7. Repeat above instructions for the remaining wheel.



Foot bracket Installation · Locking Handle


for Powermate Inc.
(Effective with engines purchased from Robin America, Wood Dale, IL, after November 15, 1993) Robin America, Inc., a division of Fuji Heavy Industries, Ltd. (herein "Robin"), warrants that each new engine sold by it will be free, under normal use and service, from defects in material and workmanship for a period listed below from the date of sale to the original retail purchaser. Robin's obligation under this Limited Warranty shall be limited to the repair and replacement, at Robin's option, of any part or parts which upon examination is/are found, in Robin's judgment, to have been defective in material or workmanship. It shall be a condition of Robin's obligation under this Limited Warranty that Robin, directly or through one of its Distributors or Service Centers authorized to service the particular engine involved, receive prompt notice of any warranty claim and that the engine or the part or parts claimed to be defective be promptly delivered, transportation prepaid, to such Distributor or Service Center for inspection and repair. All repairs qualifying under this Limited Warranty must be performed by Robin or one of its authorized Distributors or Service Centers.
Robin Four-Cycle, Air-cooled, Gasoline Engines Limited 3 years Warranty
The repair or replacement of any part or parts under this Limited Warranty shall not extend the term of the engine warranty beyond the original term as set forth above.
The customer is responsible for all transportation charges in connection with any warranty work.
Robin reserves the right to modify, alter or improve any engines or parts without incurring any obligation to modify or replace, any engine or parts previously sold without such modification, alternation or improvement.
No person is authorized to give any other warranty or to assume any additional obligation on Robin's behalf unless made in writing and signed by an officer of Robin. THIS WARRANTY, AND ROBIN'S OBLIGATION HERE UNDER, ARE IN LIEU OF ANY OTHER WARRANTIES OR OBLIGATIONS OF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE-OF. ROBIN SHALL IN NO EVENT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES.



4970 Airport Road P. O. Box 6001 Kearney, NE 68848
1-800-445-1805 1-308-237-2181 Fax 1-308-234-4187
© 2007 Powermate Corporation. All rights reserved. Powermate ® is a registered trademark of Powermate Corporation.
© 2007 Powermate Corporation. Tous droits réservés. Powermate® est une marque déposée de Powermate Corporation.
© 2007 Powermate Corporation. Reservados todos los derechos. Powermate ® es una marca comercial registrada de Powermate Corporation.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.