Page 1 of the Powermate PMC645500 user manual — SAFETY AND OPERATION RULES
Page 1 · cliquer pour agrandir
Page 1
Powermate PMC645500 — SAFETY AND OPERATION RULES diagram (page 1)
Fig. 1
Powermate PMC645500 — SAFETY AND OPERATION RULES diagram (page 1)
Fig. 2
Powermate PMC645500 — SAFETY AND OPERATION RULES diagram (page 1)
Fig. 3

hazardous situation which, if not

avoided, may result in minor or

which, if not avoided, could result in death or serious injury.

moderate personal injury, or

serious injury.

property damage.

SAFETY AND OPERATION RULES

11.Store the generator in a well ventilated area with the fuel tank empty. Fuel should not be stored near the generator.

1. Read carefully and understand operator manual prior to operation of this product. Read and understand engine manual prior to operation. Follow all warnings and instructions.

12.Your generator should never be operated under these conditions: a. Uncontrolled change in engine speed. b. Electrical output loss. c. Overheating in connected equipment. d. Sparking. e. Damaged receptacles. f. Engine misfire. g. Excessive vibration. h. Flame or smoke. i. Enclosed compartment. j. Rain or inclement weather. Do not let the unit

2. Know your equipment. Consider the applications, limitations, and the potential hazards specific to your unit.
3. Equipment must be placed on a firm, supporting surface.
4. Load must be kept within rating stated on generator nameplate. Overloading will damage the unit or shorten its life.

get wet when operating.

13.Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be corrected before operation.

5. Engine must not be run at excessive speeds. Operating an engine at excessive speeds increases the hazard of personal injury. Do not tamper with parts which may increase or decrease the governed speed.

14.The generator should be operated, serviced, and refueled only under the following conditions: a. Start and run the generator outdoors. Do

6. To prevent accidental starting, always remove the spark plug or cable from the spark plug before maintaining the generator or engine.

not run the generator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges. DANGER - CARBON MONOXIDE HAZARD: The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, may cause death or serious personal injury. If you start to feel sick, dizzy or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning. b.Good ventilation for cooling. Air flow and

7. Units with broken or missing parts, or without protective housing or covers, should never be operated. Contact your service center for replacement parts.
8. Units should not be operated or stored in wet or damp conditions or on highly conductive locations such as metal decking and steel work.
9. Keep the generator clean and free of oil, mud and other foreign matter.

temperatures are important for air cooled units. Temperatures should not exceed 104º F ambient (40º C). c. Refuel the generator in a well lighted area.

10.Extension cords, power cords, and all electrical equipment must be in good condition. Never operate electrical equipment with damaged or defective cords.

Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.

Page 2 of the Powermate PMC645500 user manual — SAFETY AND OPERATION RULES
Page 2 · cliquer pour agrandir
Page 2
d. Do not refuel near open flames, pilot lights, or SPARK ARRESTER sparking electrical equipment such as power tools, welders, and grinders. e. The muffler and air cleaner must be installed SPARK ARRESTING MUFFLER and in good condition at all times as they YOUR PRODUCT MAY NOT BE EQUIPPED WITH A function as flame arresters if backfiring occurs. SPARK ARRESTING MUFFLER. If the product will be used f. Do not smoke near the generator. around flammable materials, such as agricultural crops, forests, brush, grass, or other similar items, then an approved 15.Ensure that generator is properly grounded. (See spark arrester should be installed and is legally required in the “Grounding the generator” section in this State of California. The California statutes requiring a spark manual.) arrester are Sections 13005(b), 4442 and 4443. Spark Arresters are also required on some U.S. Forest Service land 16.Do not wear loose clothing, jewelry, or anything and may also be legally required under other statutes and that may be caught in the starter or other rotating ordinances. An approved spark arrester is available from your parts. Coleman® Powermate® product dealer, or may be ordered from Powermate Corporation, P.O. Box 6001, Kearney, 17.Unit must reach operating speed before electrical Nebraska 68848. 1-800-445-1805. Spark arresters can also loads are connected. Disconnect loads before be ordered from our website, www.powermate.com. turning off engine. DETERMINING TOTAL WATTAGE 18.To prevent surging that may possibly damage equipment, do not allow engine to run out of fuel when electrical loads are applied. In order to prevent overloading and possible damage to your generator it is necessary to know the total wattage of the 19.When powering solid state equipment, a Power connected load. To determine which tools and/or appliances Line Conditioner should be used to avoid possible your generator will run follow these steps: damage to equipment. 1. Determine if you want to run one item or multiple items 20. Do not stick anything through ventilating slots, simultaneously. even when the generator is not operating. This can 2. Check wattage requirements for the items you will be damage the generator or cause personal injury. running by referring to the load’s nameplate or by calculating it (multiply amps x volts = watts). 21.Before transporting the generator in a vehicle, 3. Total the watts for each item. If the nameplate only gives drain all fuel to prevent leakage that may occur. volts and amps, multiply volts x amps = watts. 1 KW = 1,000 watts. 22.Use proper lifting techniques when transporting 4. Motorized appliances or tools require more than their the generator from site to site. Improper lifting rated wattage for start up. techniques may result in personal injury. NOTE: Allow 2 1/2 to 4 times the listed wattage for starting equipment powered by electric motors. 5. The generator’s rated watts should match or exceed the total number of watts required for the equipment you 23.To avoid burns, do not touch engine muffler or want to run. other engine or generator surfaces which became 6. Always connect the heaviest load to the generator first, hot during operation. then add other items one at a time. 24.Do not alter or modify the heat shield. NOTE: Additional information on determining wattage requirements can be found on our website: www.powermate.com.SPARK ARRESTER www.powermate.com6Customer Hotline 1-800-445-1805Customer Hotline 1-800-445-1805
Powermate PMC645500 — SAFETY AND OPERATION RULES diagram (page 2)
Fig. 4
Page 3 of the Powermate PMC645500 user manual — INSTALLATION
Page 3 · cliquer pour agrandir
Page 3

OPERATING VOLTAGE

To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Powermate PMC645500 — OPERATING VOLTAGE diagram (page 3)
Fig. 5

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.

If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.

Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.

A power line conditioner should be used when running one or more of the following solid state items:

Powermate PMC645500 — OPERATING VOLTAGE diagram (page 3)
Fig. 6

Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment

To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.

Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805 or www.powermate.com

INSTALLATION

Always follow local codes and regulations that apply to the installation of any item that concerns this product.

1. NFPA 70 - National Electrical Code. 2. NFPA 37 - Standard for Installation and Use of Stationary Combustible Engines. 3. Agricultural Wiring handbook of Farm Standby Electric Power.

To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.

Page 4 of the Powermate PMC645500 user manual — LUBRICATION
Page 4 · cliquer pour agrandir
Page 4

BEFORE OPERATION

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine. (See the accompanying engine manual for more information.)

GROUNDING THE GENERATOR

The National Electric Code requires that this product be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a suitable ground connection. However, consult with a local electrician to insure that local codes are being adhered to.

If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.

FUEL

Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane). We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

GROUND TERMINAL LOCATION:

Powermate PMC645500 — GROUND TERMINAL LOCATION: diagram (page 4)
Fig. 7

Do not overfill the tank. Keep maximum fuel level 1/4 inch below the top of the fuel tank. This will allow expansion in hot weather and prevent overflow.

CORD-SET WIRING

If your generator is supplied with a 4-wire 120/240V twistlock receptacle, ground and neutral may be connected together at the load side.

Do not use a pipe carrying combustible material as the ground source.

LUBRICATION

DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. (See the accompanying engine manual for this information.) Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Fill the engine with oil according to the engine manual. For units with a dipstick, fill oil to the proper level. Units without a dipstick should be filled to the top of the opening of the oil fill.

Page 5 of the Powermate PMC645500 user manual — MAJOR GENERATOR FEATURES
Page 5 · cliquer pour agrandir
Page 5

MAJOR GENERATOR FEATURES

Powermate PMC645500 — MAJOR GENERATOR FEATURES diagram (page 5)
Fig. 8
Powermate PMC645500 — MAJOR GENERATOR FEATURES diagram (page 5)
Fig. 9
A. Control Panel Power Bar - This bargraph provides a quick visual indication of B. 120 V, 20 Ampere Duplex Receptacle the percentage of rated output currently being supplied. 20 amps of current may be drawn from each half of the % Load Indicator - This is a numeric version of the Power Bar. receptacle. However, total power drawn must be kept within Hour Meter - This indicates the total number of hours the nameplate ratings. These receptacles may be used along with the generator has run since manufacture. twistlock receptacle provided the generator is not overloaded. Maintenance Timer - This indicates the number of hours the C. 120 Volt GFCI Receptacle generator has run since the last user reset. This timer should be reset Ground Fault Circuit Interrupter duplex receptacle is rated so after every oil change or any other maintenance task. Follow the that a total of 20 amps may be drawn regardless of whether both instructions in the engine owners manual for proper engine halves or just one receptacle is used. This receptacle may be used maintenance intervals. along with other receptacles provided the generator is not overloaded Reset Button - Pressing and holding this button will reset the and total power drawn is kept within nameplate ratings. Maintenance Timer to 0 HRS. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc. D. 120/240 V, 30 Ampere Twistlock Receptacle A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings. E. Circuit Breakers H. Fuel Shut-Off The receptacles are protected by an AC circuit breaker. If the I. Engine On/Off Switch generator is overloaded or an external short circuit occurs, the circuit J. Engine Choke Lever breaker will trip. If this occurs, disconnect all electrical loads and try K. Yamaha 10HP OHV Engine with: to determine the cause of the problem before attempting to use the Cast-Iron Cylinder Sleeve generator again. If overloading causes the circuit breaker to trip, Low Oil Sensor reduce the load. NOTE: Continuous tripping of the circuit L. 7 Gallon Plastic Fuel Tank breaker may cause damage to generator or equipment. The M. Fuel Gauge circuit breaker may be reset by pushing the button of the breaker. N. Generator Head F. Panel Light O. Storage Bin The panel light comes on automatically when the engine is P. Oil Drain started. The light goes off automatically when the engine is shut off. Q. Pneumatic Tires G. DIGITECH™ Digital Information Center R. Retractable Handles The DIGITECH™ Digital Information Center is a patented S. Handle Release Buttons feature available only on select Coleman® Powermate® Brand To extend the handles, press the handle release buttons on the generators. wheel end of the unit. Pull the handles out until the handle release At a glance, the user can instantly see how much of the buttons lock in place on the engine end of the unit. generator's output capacity is being used and how much power To retract the handles, press the handle release buttons on the remains available. The display also indicates the time since last user engine end of the unit. Push the handles in until the reset and the total accumulated runtime of the generator. handle release buttons lock in place on the wheel end of the unit. www.powermate.com9Customer Hotline 1-800-445-1805
Powermate PMC645500 — MAJOR GENERATOR FEATURES diagram (page 5)
Fig. 10
Page 6 of the Powermate PMC645500 user manual — PRE-START PREPARATION
Page 6 · cliquer pour agrandir
Page 6

STARTING THE UNIT

Powermate PMC645500 — STARTING THE UNIT diagram (page 6)
Fig. 11
  • Provide adequate ventilation for toxic exhaust gases and cooling air flow.
  • Do not start or run the generator in an enclosed area, even if door or windows are open.
  • Engines give off carbon monoxide, an odorless, colorless, poison gas.
  • Breathing carbon monoxide can cause nausea, fainting or death.

Gasoline is very dangerous. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. 1. Do not fill fuel tank with engine running. 2. Do not spill fuel while refilling tank. 3. Do not mix oil with gasoline. 4. Follow all instructions and warnings in the engine manual.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.

SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for two minutes without load. 3. Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models). 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If a cover is used, do not install until unit has cooled.

Powermate PMC645500 — PRE-START PREPARATION diagram (page 6)
Fig. 12

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Page 7 of the Powermate PMC645500 user manual — STARTING THE UNIT
Page 7 · cliquer pour agrandir
Page 7
BREAK-IN PROCEDURE 4. Plug a lamp or light into the generator before starting the Controlled break-in helps insure proper engine and generengine. The light source will illuminate when voltage has ator operation. Follow engine procedure outlined in engine returned. manual. 5. Start the engine with no load connected to the generator. 6. Attach the "-" lead of the battery to the negative brush. Very briefly, touch the "+" lead of the battery to the positive brush as shown. Remove as soon as voltage builds up. To measure voltage, use a plug-in voltmeter. Do not apply heavy electrical load during break-in period (the first two to three hours of operations). MAINTENANCE GENERATOR: Brushes The brushes in the generator should be inspected once every year for chips and cracks. Brushes should be replaced when they are worn to 1/4 inch (7mm). HEAT SHIELD: NOTE: Replace brushes in sets only, never separately. Inspect to ensure that all heat shields and heat deflectors are intact and in place. Do not remove any parts or modify INSPECTING THE BRUSHES: parts. Removing or modifying parts could cause serious 1. Remove cover plate (R). damage to the unit. 2. Remove 4 stator bolts (U) and endbell. 3. Remove screws holding the protective plate on the inside ENGINE: Carburetor Icing of the endbell. During the winter months, rare atmospheric conditions 4. Disconnect the green (-) or blue (+) brush wires from may develop which will cause an icing condition in the the tab. carburetor. If this develops, the engine may run rough, loose 5. Remove brush mounting screws (S). power, and may stall. Call Product Service for more 6. Slide brushes (T) from holders. information. 7. Replace if worn to 1/4 inch (7mm). NOTE: Refer to the engine manufacturer's manual 8. Do not over tighten screws. for service and maintenance of the engine. QUICK STARTING TIPS FOR UNITS THAT HAVE BEEN SITTING FOR AWHILE: If your unit has been sitting around for a long time period and is hard to start, try doing some of these easy steps before calling the Customer Hotline. 1. Check the oil level. 2. Replace the old fuel. NOTE: Replace only with brushes specified in parts 3. Change the spark plug. list. Other brushes may appear to be identical but may have completely different mechanical and electrical 4. Check the fuel lines. Make sure the fuel valve is open. characteristics. 5. Check all generator parts for integrity. EXCITING THE GENERATOR: 6. Clean the Carburetor. (See engine manual for service If there is a loss of residual magnetism (voltage will not centers) build up), it may be necessary to re-excite the unit. 1. Use a 6-volt lantern battery (dry cell) or a 12-volt automotive battery. 2. Disconnect all loads from generator. 3. Remove the brush cover. www.powermate.com11Customer Hotline 1-800-445-1805Customer Hotline 1-800-445-1805
Powermate PMC645500 — STARTING THE UNIT diagram (page 7)
Fig. 13
Powermate PMC645500 — STARTING THE UNIT diagram (page 7)
Fig. 14
Page 8 of the Powermate PMC645500 user manual — HOW TO ORDER REPLACEMENT PARTS
Page 8 · cliquer pour agrandir
Page 8

SERVICE AND STORAGE

LIMITED WARRANTY

INFREQUENT SERVICE

Warranty Coverage: Powermate Corporation (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.

If the unit is used infrequently, difficult starting may result. to eliminate hard starting, run the generator at least 30 minutes every month. Also, if the unit will not be used for some time, it is a good idea to drain the fuel from the carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or is being stored more than one month, follow these instructions: 1. Replenish engine oil to upper level. 2. Drain gasoline from fuel tank, fuel line and carburetor. 3. Pour about one teaspoon of engine oil through the spark plug hole, pull the recoil starter several times and replace the plug. Then pull the starter until you feel the piston is on its compression stroke and leave it in that position. This closes both the intake and exhaust valves to prevent the inside of the cylinder from rusting. 4. Cover the unit and store in a clean, dry place that is well ventilated away from open flame or sparks.

Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. The warranty is void if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual. · The Company will not pay for repair costs or labor performed without the Company's prior authorization.

Warranty Period: Two (2) years from the date of purchase on everything except the EnduraTM frame: The EnduraTM frame is warranted against breakage, warping and color fading for five (5) years. Warranty periods apply only to the intended use of the product in consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to one (1) year from the date of purchase. The warranty does not apply if the product is used as rental equipment. For warranty service, customer must provide dated proof of purchase and must notify the Company within the warranty period.

SERVICE INFORMATION

CONTACT THE COLEMAN® POWERMATE® PRODUCT SERVICE DEPARTMENT AT

1-800-445-1805 or at www.powermate.com to obtain warranty service information or to

For warranty service: Call toll free 800-445-1805, or write to Powermate Corporation, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68848.

order replacement parts or accessories.

HOW TO ORDER REPLACEMENT PARTS

Even quality built equipment such as the Coleman® Powermate® electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information: 1. Model No. and Serial No. and all specifications shown on the Model No./Serial No. plate. 2. Part number or numbers as shown in the Parts List section. 3. A brief description of the trouble with the generator. NOTE: If replacement parts are required for the engine, contact one of the engine manufacturer's service centers.

EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply to you.

4970 Airport Road P. O. Box 6001 Kearney, NE 68848

1-800-445-1805 www.powermate.com

Powermate Corporation

Page 9 of the Powermate PMC645500 user manual — CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT
Page 9 · cliquer pour agrandir
Page 9

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board and Powermate Corporation (herein "Powermate") are pleased to explain the evaporative emission control system (EECS) warranty on your 2006 generator. In California, new generators must be designed, built and equipped to meet the State's stringent anti-smog standards. Powermate must warrant the EECS on your generator for the periods of time listed below, provided there has been no abuse, neglect or improper maintenance of your generator.

Your EECS includes parts such as: fuel hoses.

MANUFACTURER'S WARRANTY COVERAGE: This evaporative emission control system is warranted for two years. The warranty period begins on the date the generator is delivered to an ultimate purchaser.

Powermate warrants to the ultimate purchaser and any subsequent owner that the generator is (i) designed, built and equipped so as to conform with all applicable regulations; and (ii) free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to that part as described in Powermate's application for certification.

If any evaporative emission-related part on your generator is defective, the part will be repaired or replaced by Powermate.

OWNER'S WARRANTY RESPONSIBILITIES: As the generator owner, you are responsible for performance of the required maintenance listed in your owner's manual. Powermate recommends that you retain all receipts covering maintenance on your generator, but Powermate cannot deny warranty solely for the lack of receipts. You should, however, be aware that Powermate may deny you warranty coverage if your generator or a part has failed due to abuse, neglect or improper maintenance or unapproved modifications.

You are responsible for presenting your generator to an authorized Powermate warranty service center as soon as the problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days. If you have a question regarding your war- ranty coverage, you should call Powermate Product Service at 1-800-445-1805.

DETAILS OF YOUR WARRANTY Subject to certain conditions and exclusions as stated below, the warranty on emission-related parts is as follows: (1) Any warranted part that is not scheduled for replacement as required maintenance in the written instructions supplied, is warranted for the period stated above. If the part fails during the period of warranty coverage, the part will be repaired or replaced by Powermate according to Subsection (4) below. Any such part repaired or replaced under warranty will be warranted for the remainder of the period. (2) Any warranted part that is scheduled only for regular inspection in the written instructions supplied, is warranted for the warranty period stated above. Any such part repaired or replaced under warranty will be warranted for the remaining warranty period. (3) Any warranted part that is scheduled for replacement as required maintenance in the written instructions supplied, is warranted for the period of time before the first scheduled replacement date for that part. If the part fails before the first scheduled replacement date, the part will be repaired or replaced by Powermate according to Subsection (4) below. Any such part repaired or replaced under warranty will be warranted for the remainder of the period prior to the first scheduled replacement date for the part. (4) Repair or replacement of any warranted part under the warranty provisions herein must be performed at an authorized Powermate warranty service center at no charge to the owner. (5) The generator owner will not be charged for diagnostic labor that is directly associated with diagnosis of a defective, emission-related warranted part, provided that such diagnostic work is performed at an authorized Powermate warranty service center. (6) Powermate is liable for damages to other engine or generator components proximately caused by a failure under warranty of any warranted part. (7) Throughout the generator warranty period stated above, Powermate will maintain a supply of warranted parts sufficient to meet the expected demand for such parts. (8) Any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner. Such use will not reduce the warranty obligations of Powermate. (9) Add-on or modified parts that are not exempted by the Air Resources Board may not be used. The use of any non-exempted add-on or modified parts by the ultimate purchaser will be grounds for disallowing a warranty claims. Powermate will not be liable to war rant failures or warranted parts caused by the use of a non-exempted add-on or modified part. (10) The repair or replacement of any warranted part otherwise eligible for warranty coverage may be excluded from such warranty

coverage if the generator has been abused, neglected or improperly maintained, and such abuse, neglect or improper maintenance was the direct cause of the need for repair or replacement of the part.

WARRANTED PARTSThe following emission warranty parts list is covered:

Fuel Hose.

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
www.powermate.com p.5
www.powermate.com p.9

Poser une question sur : Powermate PMC645500

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Powermate PMC645500

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Powermate PMC645500 manuel PDF

36 pages·788 KB·Groupe électrogène portable·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…