Warranty Coverage: Powermate Corporation (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.
* Robin EX30 OHC engine
* Cast-iron cylinder sleeve
* Low oil sensor
* Receptacles on control panel
* 5 gallon plastic fuel tank
Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · Engine is covered exclusively by a separate warranty from the engine manufacturer, included with the engine Manual. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company's prior authorization.
A. 120 V, 20 Ampere Duplex Receptacle 20 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings. These receptacles may be used along with the twistlock receptacle provided the generator is not overloaded.
B. 120/240 V, 20 Ampere Twistlock Receptacle A maximum of 20 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.
Warranty Period: Two (2) years from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to one (1) year from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period.
C. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
For warranty service: Call toll free 800-445-1805, or write to Powermate Corporation, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68848.
EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
D. Engine On/Off Switch
E. Engine Start Button

F. CordKeeper™ Restraint The CordKeeper™ restraint is a unique feature used to prevent plugs from being pulled out of the 120-volt receptacles.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply to you.

* Electric start · * Portability Kit

TOOLS REQUIRED: 7/16”, 1/2”, 9/16", and 5/8” sockets and ratchets, block(s) of wood (minimum of 6” tall). Refer to the parts list on page 9.
WHEEL INSTALLATION 1. Block up end of generator opposite the fuel tank cap to install wheel kit. 2. Insert wheel spacer (item 45) into the center of the wheel (item 31). 3. Slide 3/8 x 4.25” bolt (item 35) and 3/8 washer (item 47) through the wheel (item 31), then through the wheel bracket on the carrier, with the offset side of the wheel hub against the wheel bracket. 4. Thread 3/8 nyloc nut (item 36) onto the bolt and tighten to securely clamp the wheel assembly to the tubing. 5. Repeat above instructions for the remaining wheel.
FOOT INSTALLATION 1. Assemble the rubber feet (item 32) to the foot bracket (item 27) using a 1/4-20 x 1.5” bolt (item 29). Thread a 1/4 washer (item 39) and a 1/4 nyloc nut (item 13) to the bolt to secure the assembly. Caution: Do not over tighten so that the foot material collapses. 2. Blocking up the alternator side of the generator, place the foot bracket under the carrier channel. Thread a 5/16-18 x 1” bolt (item 48) with a 5/16 washer (item 34) through the mounting holes and thread a 5/16 washer (item 34) and a 5/16 nyloc nut (item 4) to the bolt to secure the foot bracket to the carrier.
HANDLE INSTALLATION 1. Place handle (item 28) over carrier tubing on same end as feet, centering handle on the carrier. 2. Slide 5/16 x 2.25” bolt (item 30) through handle, handle bracket, and 5/16 washers (item 41) as shown in diagram and secure with 5/16” nyloc nut (item 4). Tighten until handle is securely clamped to the bracket.
LOCKING HANDLE 1. Attach the lanyard (item 44) to the release pin (item 40) and carrier as shown in the illustration. 2. To lock the handle (item 28) in the extended position, align the holes in the handle bracket with the holes in the carrier bracket and insert the release pin (item 40).




Installation: Hook up the new battery, or re-install the new battery, as follows: Place the battery in the position provided. Connect the Red 10 Gauge wire to the positive (+) terminal and the Black 10 Gauge wire to the negative (-) terminal. Make sure all connections are tight. Your battery is now connected and ready for use. Turn the start rocker switch to the on position and push the start button to crank the engine.
This generator model is provided with both electric start and recoil start capabilities. Avoid prolonged cranking, as it can damage the engine.
The supplied charger is capable of 4A at 12 Volts when plugged into a 120 Volt AC outlet receptacle. This can be either from the generator output or from a standard wall outlet receptacle. It can be used as a floating charger for constant charging or as a bulk charger. The indicator status tells the charge with either a Green (float) or Red (bulk) LED light. Please see the supplied Specification for further information on the charger.

The battery provided is a nominal 12 volt sealed rechargeable lead-acid battery and can be operated in any position without leakage. It complies with non-spillable battery regulations. Its convenient size offers a 30% reduction over conventional batteries. Length = 5.94 inches, Width = 2.55 inches, Height = 4.39 inches, Weight = 7.05 lbs 10AH Rating UL Recognized
Battery Kit Parts List Item Description Qty A. *Bolt, 1/4-20 X 5.5” 2 B. *Washer 5/16 2 C. Hold down bar (P/N 0065057) 1 D. *Nyloc nut, 1/4-20 2
* These are standard parts available at your local hardware store.
Initial Battery Connection - Refer to the Installation Instructions Below.
Battery Removal & Installation:
Removal: Remove the wires from the negative and positive terminals, being careful not to short across the terminals. (Shorting the terminals together can cause sparks, damage to the battery or generator or even burns or explosions.) Always abide by the safety warnings provided with the battery. Remove the battery and re-cycle and dispose of properly.

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.