FR
Powermate logo
Notice d'utilisation officielle

Powermate PC0496504.18

16 pages·1 MB·Groupe électrogène portable·PDF·ENDEITNLJA
Powermate PC0496504.18
Table des matières 10 sections PC0496504.18 Insert Additif Adición · www.colemanpowermate.com LFL 10/02 0061908 · MAJOR GENERATOR FEATURES · CONTROL PANEL · … AfficherMasquer
Page 1 of the Powermate PC0496504.18 user manual — www.colemanpowermate.com LFL 10/02 0061908
Page 1 · cliquer pour agrandir
Page 1

PC0496504.18 Insert Additif Adición

Powermate PC0496504.18 — PC0496504.18 Insert Additif Adición diagram (page 1)
Fig. 1 · PC0496504.18 Insert Additif Adición

Honda 6500 – ELECTRIC GENERATOR Honda 6500 – GROUPE ELECTROGENE Honda 6500 – GENERADOR ELECTRICO

www.colemanpowermate.com LFL 10/02 0061908

Page 2 of the Powermate PC0496504.18 user manual — 2 English
Page 2 · cliquer pour agrandir
Page 2

MAJOR GENERATOR FEATURES

E. Voltmeter Provides visual indication of generator output voltage from 0-300 volts.

* 13 HP Honda OHV engine

F. 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with th other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a both through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc.

* Cast-iron cylinder sleeve

* Low oil sensor

* Receptacles on control panel

* Voltmeter and hour meter on panel

* Automatic voltage regulator (AVR)

G. 120 V, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps or 3600 watts from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.

* 4.6 gallon metal fuel tank

Powermate PC0496504.18 — MAJOR GENERATOR FEATURES diagram (page 2)
Fig. 2

H. CordKeeper™ The CordKeeper™ is a unique feature used to prevent plugs from being pulled out of the 120-volt receptacles.

CONTROL PANEL

A. 120/240 V, 30 Ampere Twistlock Receptacle A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.

I. Battery Charger NOT RECOMMENDED FOR USE WITH GEL PACK, SEALED OR SMALL (MOTORCYCLE) BATTERIES.

These generators contain an additional circuit used for battery charging purposes. A double binding post is provided on the control panel. The battery charger on this generator is referred to as an unregulated taper charger - the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery's state of charge. As the on-charge output current to the battery decreases, the output current to the battery increases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after a maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery. The charge level of the battery should be checked periodically.

B. Idle Control Switch Some models are equipped with an idle control switch. (See Idle Control).

C. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

Before charging a storage battery, check the electrolyte fluid level in all the cells. Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer's required level.

D. Hour Meter An hour meter is provided to keep track of run time of the unit. This may be used to track maintenance schedules.

2 English

Show 5 more labels / short text on this page
* Idle control · * Battery charger · * CordKeeper™ · * Spark arrester · * Portability Kit
Page 3 of the Powermate PC0496504.18 user manual — MAJOR GENERATOR FEATURES
Page 3 · cliquer pour agrandir
Page 3
Use cables approved for battery charging. Connect a red IDLE CONTROL OPERATION clip to the positive terminal of the battery. Connect a black clip to the negative terminal of the battery. Connect the other end of the clip wire to the corresponding black(-) and red (+)binding The Idle Control circuit is designed to extend engine life posts on the generator panel. After the battery is fully charged, and improve fuel usage by slowing the engine down to remove the battery charging cable from the generator and then approximately 2000 RPM in a “No Load” condition. The noise is disconnect from the battery posts. also greatly reduced during this condition. When power is required from the generator an electronic WARNING: Battery electrolyte fluid is control module automatically senses current flow in the comprised of sulfuric acid that can be very electrical outlet and allows the engine to return to full speed or dangerous and cause severe burns. Do not standard operating condition. Likewise, when the load is allow this fluid to contact eyes, skin, clothing, removed, the generator will automatically return to the idle etc. If contact or spillage does occur, flush condition after a 4-5 second delay. the area with water immediately. A convenient switch is mounted in the control panel for easy access and will disable the Idle Control circuitry when in WARNING: Do not continue to charge a the off position. battery that becomes hot or is fully charged. DC CIRCUIT BREAKER: The maximum current available from the battery charger circuit is 15 amps. An automatic DC circuit breaker has been provided to protect the circuit from overloads and assure that the battery gets recharged. If an overload occurs, the circuit breaker will trip. After it cools, it will automatically reset itself. The battery's maximum rate of charge will eventually reduce to less than 15 amps and then to zero as the battery approaches a 100 percent state of charge.IDLE CONTROL OPERATION IDLE CONTROL TROUBLE SHOOTING PROBLEMPOSSIBLE CAUSESOLUTION Unit will not idleControl panel switch not onTurn to idle on position Load plugged into receptacleUnplug load Poor connection or faulty cordCheck & repair Bad I.C. module; Bad electro-magnet or solenoids; Bad statorReplace Consult dealer Unit idles even with load plugged inLoad not heavy enoughTurn idle switch to off position Increase load Bad I.C. moduleReplace Consult dealer Unit tries to idle but won’t stay latchedElectro-magnet or solenoid position incorrectReset magnet or solenoid position for 2000 RPM idle speed Consult dealer Flapper bracket loose or bentTighten or straighten Replace flapper. Readjust to 2000 RPM Engine not running smoothlyAdjust carburetor Consult dealer English3
Page 4 of the Powermate PC0496504.18 user manual — 4 English
Page 4 · cliquer pour agrandir
Page 4

LIMITED WARRANTY (NOT VALID IN MEXICO)

This product is warranted by Coleman Powermate, Inc. to the original retail consumer against defects in material and workmanship for a period of two years from the date of retail purchase and is not transferable. This two year warranty applies only to products used in consumer applications. If this generator is used in a commercial application, then the period of warranty coverage is limited to one (1) year from the date of purchase.

Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty.

WHAT IS COVERED: Replacement parts and labor.

WHAT IS NOT COVERED: Transportation charges to Coleman Powermate, Inc. for defective products. Transportation charges to consumer for repaired products. Brushes, fuses, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure to perform normal maintenance. Power units or engines which are covered exclusively by the warranties of their manufacturer. Sales outside of the United States or Canada. Any other expense including consequential damages, incidental damages, or incidental expenses, including damage to property. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

IMPLIED WARRANTIES: Any implied warranties, including the Implied Warranties of Merchantability and Fitness For A Particular Purpose, are limited in duration to one (1) year from the date of retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

HOW TO OBTAIN WARRANTY PERFORMANCE: Replacement parts and service are available from Coleman Powermate, Inc. Service Centers. Locate your nearest Service Center by calling TOLL FREE 1-800-445-1805. In the unlikely event a Service Center can not be located you may call Coleman Powermate, Inc. for a return authorization number. Any unit returned WITHOUT an authorization number will be refused.

To the extent any provision of this warranty is prohibited by federal, state, or municipal law, and cannot be preempted, it shall not be applicable. This warranty gives you specific rights, and you may also have other rights which vary from state to state.

4 English

Page 5 of the Powermate PC0496504.18 user manual — LIMITED WARRANTY (NOT VALID IN MEXICO)
Page 5 · cliquer pour agrandir
Page 5
PARTS LIST / LISTE DES PIÈCES / LISTA DE REPUESTOS REF. NO.PART NO.DESCRIPTIONDESCRIPTIONDESCRIPCIÓNQTY 1Note AEngine, 13 hp Honda OHVMoteurMotor1 20050236.01Adapter, engineAdaptateur pour moteurAdaptador, motor1 30000919.01Bolt, wz 3/8-16 x 3/4BoulonPerno4 40052293Rotor, 6.5 kWRotorRotor1 5Note BWasher, lock 5/16Contre-écrou 5/16Arandela, de cierre 5/163 60049613.01Bolt, hex 5/16-24 x 8.69BoulonPerno1 70059100Stator, 6.5 kW, 60 HZStatorEstator1 80056717Connector, hsg. set, endbellJeu pr logement prise, couvre-enroul. alojamiento, termnador.Conector, conjunto2 8A0056720Connector, hsg. set, endbellJeu pr logement prise, couvre-enroul alojamiento, termnador.Conector, conjunto2 90046719Connector, hsg. set, panelJeu pr logement prise, tableau alojamiento, panelConector, conjunto1 100050511.02Endbell Wired AVRCouvre-enroulement, câblage complet tableauCaja posterior con cable1 10A0050439Brush, E-4RBalais, E-4REscobilla, E-4R2 10C0034819.01CapacitorCapaciteurCapacitor1 10D0034843.01DiodeDiodeDiodos2 10E0038976Heat SinkDiode dissipatrice de chaleurSumidero térmico diodos1 10F0048844Brush CoverCouvre-balaisCubierta de escobillas1 110035170Bolt, hex hd 1/4-20 x 8BoulonPerno4 120008854Lug, groundOeillet de mise à la terreTerminal, tierra1 13Note BWasher, flat 1/4Rondelles plates 1/4Arandela, plana 1/410 140049352Washer, flat 5/16 WRondelles plates 5/16Arandela, plana 5/164 150040832Nut, nyloc 1/4-20Écrous nyloc 1/4-20Tuerca, nyloc 1/4-2011 160061839Carrier, assembly, fullEnsemble transportTransportador, conjunto1 17Note BBolt HH 1/4-20 x 1.25BoulonPerno6 180052627AVRAVRAVR1 190051094IsolatorSectionneur moteurAislador4 200057190Bracket Idle Control SolenoidSectionneurConjunto de soporte1 210056039Bracket, statorSectionneur statorConjunto de soporte1 220049279Bolt, wz 5/16-18 x 1/2BoulonPerno3 230048736Nut, nyloc 5/16-18Écrous nyloc 5/16-18Tuerca, nyloc 5/16-185 25Note BWasher, flat 5/16Rondelles plates 5/16Arandela, plana 5/165 26Note BBolt, 5/16-18 x 1 1/2BoulonPerno2 280049224Assembly, ground wireEns. fil de masse tressé a tierraConjunto, cable trenzado1 29Note BWasher, star external 5/16Rondelles à dents 5/16 externa 5/16Arandela, estrella3 30Note BBolt, hex 5/16-18 x 3/4Boulon, tête hex 5/16-18 x 3/4Perno1 310057307Idle control assemblyCommande de ralentiConjunto del control de la marcha en vacio1 36Note CFuel tank assemblyAssemb. complet du réservoirConjunto tanque1 36A0061817Fuel Gauge/ScrewsCombustible Indicador/TornillosEssence Écartement/Visser1 36B0061942Strainer BasketPassoire PanierColador Canasta1 36C0061816Fuel CapCapuchonTapa de combustible1 370061811Fuel Shut OffFermeture d’essenceApagado combustible1 37A0061876Filter, fuel valve and washerFiltre et rondellesFiltro y arandela1 37B0061875Nut, fuel valveÉcrousTuerca1 37C0051102Filter, fuelFiltre à carburantFiltro combustible1 400059553Panel, wiredTableau compl. câbléPanel, abeado completo1 40A0049071Circuit Breaker 20 ampDisjoncteurs 20 ampCortacircuitos 20 amp1 40B0048337Circuit Breaker 35 ampDisjoncteurs 35 ampCortacircuitos 35 amp1 40C0056207Switch, RockerInterrupteurInterruptor1 40F0050625.02Module, idle controlModule de commande du ralentiMódulo, control en vacío1 40G0057308Assembly I/C wiresConnecteur de l’assemblage de filsConector conjunto alambre1 40H0053020GFCI receptaclePriseRecept1 40K0052553Circuit Breaker 30 amp dualDisjoncteurs 35 ampCortacircuitos 35 amp1 410056438Hour MeterHeure MétreHora Metro1 420057799VoltmeterVoltage métreVoltaje metro1 430057800DC ReceptacleDC PriseDC Recept.1 450053320Screw, 10-24 x .63VisTornillo4 480012526Bolt, hex 1/4-20 x .75BoulonPerno1 12
Page 6 of the Powermate PC0496504.18 user manual — LIMITED WARRANTY (NOT VALID IN MEXICO)
Page 6 · cliquer pour agrandir
Page 6

Electrical: For models approved for the City of Los Angeles (PL’s), the ampacity of the phase conductors from the generator terminals to the first over current device shall not be less than 115 percent of the nameplate rating of the generator.

Remarque A: Coleman Powermate ne fournit pas de moteurs dans ses pièces détachées. Les moteurs sont couverts par la garantie du fabricant de moteurs. Consulter le manuel du moteur inclus ou contacter notre département de service après-vente pour toute assistance. Remarque B: Ces pièces sont des pièces standard disponibles en quincaillerie. Remarque C: Pour commander un réservoir de rechange, contacter Centre de service Coleman Powermate le plus proche.

Électricité: Pour les modèles a approuvé pour la ville de Los Angeles (PL’s): La charge limite en ampères des fils de phase allant des bornes du groupe électrogène au premier appareil en surcharge ne doit pas être inférieure à 115% de la puissance nominale indiquée sur la plaque des caractéristiques du groupe électrogène.

Nota A: Coleman Powermate no proporcionará los motores como repuestos. Los motores están cubiertos por medio de la garantía del fabricante del motor. Consulte el manual adjunto del motor o comuníquese con nuestro departamento de servicio para recibir ayuda al respecto. Nota B: Estas son piezas estándar disponibles en su ferretería local. Nota C: Para hacer pedidos de tanques, localice el Centro de Servicio de Coleman Powermate más cercano.

Eléctricos: El amperaje de los conductores de fase desde los terminales del generador al primer dispositivo de sobrecorriente no podrâ ser menor que 115 porciento del valor nominal que aparece en la placa de identificación del generador en los modelos aprobados para la ciudad de Los Angeles (PL's).

Page 7 of the Powermate PC0496504.18 user manual — NOTES – REMARQUES – NOTAS
Page 7 · cliquer pour agrandir
Page 7

NOTES – REMARQUES – NOTAS

Page 8 of the Powermate PC0496504.18 user manual — NOTES – REMARQUES – NOTAS
Page 8 · cliquer pour agrandir
Page 8

NOTES – REMARQUES – NOTAS

Page 9 of the Powermate PC0496504.18 user manual — 4970 Airport Road P. O. Box 6001 Kearney, NE 68848
Page 9 · cliquer pour agrandir
Page 9
Powermate PC0496504.18 — 4970 Airport Road P. O. Box 6001 Kearney, NE 68848 diagram (page 9)
Fig. 3 · 4970 Airport Road P. O. Box 6001 Kearney, NE 68848

4970 Airport Road P. O. Box 6001 Kearney, NE 68848

1-800-445-1805 1-308-237-2181 Fax 1-308-234-4187

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
IDLE CONTROL TROUBLE SHOOTING p.3
IDLE CONTROL TROUBLE SHOOTING p.3
PROBLEM p.3
Unit will not idle p.3
Unit will not idle p.3
Unit idles even with load plugged in p.3
Unit idles even with load plugged in p.3
Unit tries to idle but won’t stay latched p.3
Unit tries to idle but won’t stay latched p.3
English p.3

Poser une question sur : Powermate PC0496504.18

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Powermate PC0496504.18

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Powermate PC0496504.18 manuel PDF

16 pages·1 MB·Groupe électrogène portable·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…