Honda 6500 – ELECTRIC GENERATOR Honda 6500 – GROUPE ELECTROGENE Honda 6500 – GENERADOR ELECTRICO

E. Voltmeter Provides visual indication of generator output voltage from 0-300 volts.
* 13 HP Honda OHV engine
F. 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with th other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a both through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc.
* Cast-iron cylinder sleeve
* Low oil sensor
* Receptacles on control panel
* Voltmeter and hour meter on panel
* Automatic voltage regulator (AVR)
G. 120 V, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps or 3600 watts from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.
* 4.6 gallon metal fuel tank

H. CordKeeper™ The CordKeeper™ is a unique feature used to prevent plugs from being pulled out of the 120-volt receptacles.
A. 120/240 V, 30 Ampere Twistlock Receptacle A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.
I. Battery Charger NOT RECOMMENDED FOR USE WITH GEL PACK, SEALED OR SMALL (MOTORCYCLE) BATTERIES.
These generators contain an additional circuit used for battery charging purposes. A double binding post is provided on the control panel. The battery charger on this generator is referred to as an unregulated taper charger - the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery's state of charge. As the on-charge output current to the battery decreases, the output current to the battery increases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after a maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery. The charge level of the battery should be checked periodically.
B. Idle Control Switch Some models are equipped with an idle control switch. (See Idle Control).
C. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
Before charging a storage battery, check the electrolyte fluid level in all the cells. Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer's required level.
D. Hour Meter An hour meter is provided to keep track of run time of the unit. This may be used to track maintenance schedules.


This product is warranted by Coleman Powermate, Inc. to the original retail consumer against defects in material and workmanship for a period of two years from the date of retail purchase and is not transferable. This two year warranty applies only to products used in consumer applications. If this generator is used in a commercial application, then the period of warranty coverage is limited to one (1) year from the date of purchase.
Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty.
WHAT IS COVERED: Replacement parts and labor.
WHAT IS NOT COVERED: Transportation charges to Coleman Powermate, Inc. for defective products. Transportation charges to consumer for repaired products. Brushes, fuses, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure to perform normal maintenance. Power units or engines which are covered exclusively by the warranties of their manufacturer. Sales outside of the United States or Canada. Any other expense including consequential damages, incidental damages, or incidental expenses, including damage to property. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES: Any implied warranties, including the Implied Warranties of Merchantability and Fitness For A Particular Purpose, are limited in duration to one (1) year from the date of retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
HOW TO OBTAIN WARRANTY PERFORMANCE: Replacement parts and service are available from Coleman Powermate, Inc. Service Centers. Locate your nearest Service Center by calling TOLL FREE 1-800-445-1805. In the unlikely event a Service Center can not be located you may call Coleman Powermate, Inc. for a return authorization number. Any unit returned WITHOUT an authorization number will be refused.
To the extent any provision of this warranty is prohibited by federal, state, or municipal law, and cannot be preempted, it shall not be applicable. This warranty gives you specific rights, and you may also have other rights which vary from state to state.


Electrical: For models approved for the City of Los Angeles (PL’s), the ampacity of the phase conductors from the generator terminals to the first over current device shall not be less than 115 percent of the nameplate rating of the generator.
Remarque A: Coleman Powermate ne fournit pas de moteurs dans ses pièces détachées. Les moteurs sont couverts par la garantie du fabricant de moteurs. Consulter le manuel du moteur inclus ou contacter notre département de service après-vente pour toute assistance. Remarque B: Ces pièces sont des pièces standard disponibles en quincaillerie. Remarque C: Pour commander un réservoir de rechange, contacter Centre de service Coleman Powermate le plus proche.
Électricité: Pour les modèles a approuvé pour la ville de Los Angeles (PL’s): La charge limite en ampères des fils de phase allant des bornes du groupe électrogène au premier appareil en surcharge ne doit pas être inférieure à 115% de la puissance nominale indiquée sur la plaque des caractéristiques du groupe électrogène.
Nota A: Coleman Powermate no proporcionará los motores como repuestos. Los motores están cubiertos por medio de la garantía del fabricante del motor. Consulte el manual adjunto del motor o comuníquese con nuestro departamento de servicio para recibir ayuda al respecto. Nota B: Estas son piezas estándar disponibles en su ferretería local. Nota C: Para hacer pedidos de tanques, localice el Centro de Servicio de Coleman Powermate más cercano.
Eléctricos: El amperaje de los conductores de fase desde los terminales del generador al primer dispositivo de sobrecorriente no podrâ ser menor que 115 porciento del valor nominal que aparece en la placa de identificación del generador en los modelos aprobados para la ciudad de Los Angeles (PL's).




1-800-445-1805 1-308-237-2181 Fax 1-308-234-4187
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| IDLE CONTROL TROUBLE SHOOTING | p.3 | ||
| IDLE CONTROL TROUBLE SHOOTING | p.3 | ||
| PROBLEM | p.3 | ||
| Unit will not idle | p.3 | ||
| Unit will not idle | p.3 | ||
| Unit idles even with load plugged in | p.3 | ||
| Unit idles even with load plugged in | p.3 | ||
| Unit tries to idle but won’t stay latched | p.3 | ||
| Unit tries to idle but won’t stay latched | p.3 | ||
| English | p.3 |
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.