Manuel d'utilisation / d'entretien du produit 8000 du fabricant AT&T
Aller à la page of 77
AT&T SECURITY SYSTEM 8000 DEALER REFERENCE MANUAL INSTALLATION INSTRUCTIONS A T& T - PROPRIETAR Y (RESTRICTED) Soley for authorized persons having a need-to-know Pursuant to Company Instructions : http://www.
CUSTOMER RELATIONS CUSTOMER SERVICE Meeting customers’ needs and expectations is what good customer service is all about. Exceeding those expectations is what AT&T is all about. The homeowners you meet have expressed their confidence and trust in your dealership and AT&T by purchasing th e Security System 8000.
Good Service Accountability Attitude Customer Contact Providing the services that people have come to expect when they buy AT&T brand products. You are the official representative of AT&T and your dealership. Every claim a customer makes and every promise you mak e to the customer determines your accountability.
6. Reassure the customer that onc e you‘ve completed the installation, you’ll review the operation of the Security System 8000 thoroughly, and answer any and all of their questions. 7. During the installation, be conscientious of any disruptions you may incur, such as wakin g small children or elderly occupants.
These basic courtesies will yield several benefits to you, your company and you r customers. You will experience a better, easier installation because the customer wil l be on you r side, not at you r side. Your dealership will benefit from the rewards of a satisfied customer: .
USING THE RESIDENTIAL SURVEY We recommend you use the AT&T Residential Survey as a Job Aid The Salesperson will use i t first to aid in making the sale. It will give you information about the sale, the customer, the agreed-upon equipment, the locations for each component, and several other useful details.
EQUIPMENT LIST LIST OF EQUIPMENT Commo n Hand Tools Slotted-Head Screwdriver 1/8" tip x 4” blade 3/1 6" tip x 4” blade 1/4" tip x 6" blade 5/16’ tip x 8” blade Phillips-Head Screwdriver No. 0 tip x 2-1/2 blade No. 1 tip x 3 ’ blade No.
INSTALLATION INFORMATION GENERAL INFORMATION Wiring Environment U.L. Requirements Use #22 AW G minimum for sensor wiring and digital communicator channels. Use #18 AWG minimum for AC power. All wire should b e UL-listed The system is designed to work in an indoor heated environment (40 to 120 degrees F.
All sensor loops connected to any transmitter should be within the same room. The IEI-510UL glass break detector should be used for the auxiliary output.
INSTALLATION STEPS I STEP 1 Meet the Customer - Confirm Correct Location NOTE: Se e Customer Relations Sectio n - page 2-l. STEP 2 Do a Walk-Through with the Customer Make sure that the customer understands what you’re going to do. Confirm any questionable placements such as keypad height with the customer.
STEP 5 Choose Central Controller Location Precautions Choosing the appropriate location for the Central Controller is critical to the proper functioning of the system. The Central Controller should be installed in the center of all the transmitters, not necessarily in the middle of the house.
Avoid these Note: The operation of HAM radio equipment can cause serious interference which can not be avoided by moving the Central Controller. Avoid installin g the Central Controller near these large metal objects: . MetaI kitchen or bathroom cupboards .
Possible Central Controller and Transmitter Locations Supervised Smoke @!I Ial @!I ISI PIRT with Curtain Lens Transformer LIVING I--- ROOM P 4 I m GARAGE Universal Transmitter Wireless Remote Transmit.
Antenna Placement The antenna for the Central Controller must have a minimum length of 7 feet and should be run in an area central to all the transmitter locations. Increasing the length of the wire does not proportionally increase the effectiveness of the reception.
Possible Antenna Run in a Multi-level Home Central Controller / Antenna Attachment Antenna Run - Down Stackable Transformer AT&T Proprietary Information 2-14.
Sample Antenna Run in a Singl e Level Home I u I KITCHEN DINING LIVING ““ ” B4r-l Controller Central I GARAGE Transformer Antenna Run AT&T Proprietary Information 2-15.
BUILDING CONSTRUCTION CONSIDERATIONS Although the 40.68 MHz band is relatively immune to most small metal objects in the home or installatio n site, some house have building materials that must be taken into consideration. Often, it is a combination of several of these factors that cause problems.
STEP 6 Install th e Central Controller Before you begin learning about how you will install the Central Controller, take a look at th e diagram below. Here we’ve shown you the DIP SWITCHES whic h will need to be set (or programmed). You can also see by the pointers where there switches are located.
A . Program th e Central Controller 1 . Set the House Code DIP switches. The HOUSE CODE is used to distinguish components in one system from those in a neighboring system. It must be the same for every component in a given system. Seven DIP switches are used to program the house code.
House Code DIP SWITCH Combinations House House Code Dip Switch Settings House House Code Dip Switch Settings Code 1 2 3 4 5 6 7 Code 1 2 3 4 5 6 7 000 OFF OFF OFF OFF OFF OFF OFF 001 OFF OFF OFF OFF O.
House Code DIP SWITCH Combinations House House Code Dip Switch Settings House House Code Dip Switch Settings Code 1 2 3 4 5 6 7 Code 1 2 3 4 5 6 7 064 ON OFF OFF OFF OFF OFF OFF 096 ON ON OFF OFF OFF .
2 . Set the Options DIP switches by following these guidelines: Switch 1 sets all system transmitters in the interior zone to either of the following ON = interior delayed OFF = interior instant Switch 2 determines whether the Central Controller’s internal sounder is on or off during an intrusion alarm.
Central Controller Terminal Strip USE UL LISTED COMPONENTS 12.0 to 14.5 VDC MAX I d 600 60 0 mA TOTAL Digital Communicator wired Horns Power Out Output senso r Sirens (12VDC) (12VDC ) CHANNELS loo p (.
STEP 7 Install the Digital Communicator NOTE: The 8700 Digital Communicator is probably installed. If it’s not, please follow these steps. 1. Plug the 8 wire ZONE INPUT connector into the Digital Communicator. 2. Plug the polarized 2 wire power connector into the Digital Communicator.
CAUTION: If it is necessary to change the time of the first test ) 6. The red LED (DS1) on the Digital communicator should be blinking to show normal operation. The LED will not ligh t if there is no DC power. A steady LED means the Watchdog circuit has detected a processor or memory problem .
STEP 8 Run the Central Controller Antenna Choose the antenn a r un Apply the information presented in the Installation Information section to the house in which you are installing the system.
STEP 9 Power Up th e Central Controller Attach th e Central Controllet antenna to th e transfomer Plug in th e Transformer Verify power CAUTION: BEFORE YOU POWER UP, PROGRAM AT LEAST ONE WIRELES S REMOTE/TRANSMITTER SO YOU CAN IMMEDIATELY ENTER TH E INSTALLER TEST MODE.
STEP 10 Enter the Installer Test Mode a. Enter the transmitter security code and then press the OFF key to put the system in the OFF state. b. Press the Test/Demo key on the Central Controller. The digital display will show a n ‘88’. Note: Quickly press the Test/Demo key.
STEP 11 Choose Transmitter Mounting Locations Wireless Remote/Transmitter and Keypad Transmitter The normal mounting height for the Wireless Remote/Transmitter and the Keypad Transmitter is between 4-l/2 to 5-l/2 feet for convenient access to the keypads.
PIRT NOTE: Avoid hot and cold air currents . Mount the unit at least three feet from strong forced-air heaters, air conditioners, or sources of drafts such as doors.The hot or cold air currents may cause false alarms, since the detector will sense a rapid change in temperature.
PIRT WIDE-ANGLE LENS COVERAGE ZONE Main Intermediate Lower Lookdown AT&T Proprietary Information 2-30.
Curtain Lens The curtain lens provides a long and narrow field of coverage for hallways and other such narrow areas. PIRT 8560 OR 8561 CURTAIN LENS COVERAGE TOP VIEW CURTAIN LENS 7 10 ZONE FIELD OF VI.
NFPA Recommendations for Detector InstalIation: Supervised Smoke Detector Transmitter (SSD T) The Nation Fire Protection Association’s Standard 74, Sectio n 2-l, reads as follows: ‘2-1.
Other Installation Considerations: To minimize the risk of fire causing injury, loss of life or property, detectors should be located on every level of the home from the basement to the attic, (furnished or unfurnished), and in every sleeping area. More specifically, detectors should be located: .
TYPICAL SUPERVISED SMOKE DETECTOR PLACEMENT IN A MULTILEVEL HOME 0 BEDROOM 0 BED ROOM A El A UVlNG KITCHEN 9Tl 0 Cl-h. * RWM I El BASEMENT fl I ‘t J Smoke Detectors For Minimum Protection Smoke Dete.
To avoid false or improper operation, don’t install detectors in the following areas: . Bathrooms. Excessive steam from a shower may cause nuisanc e alarms. - Directly outside bathrooms. - Too near forced-air ducts used for heating or air conditioning .
STEP 12 Perform RF Link Tests on all locations 1. Use a pencil to press either the Home, Away, or Off key on the Wireless Remote/Transmitter. Transmitter Locations 2. Listen for the proper number of indication beeps from the Central Controller. 3 Beeps - 2 Beeps - No Beep s - Excellen t RF Link.
STEP 13 Install Sensors that Utilize the Central Controlle r hardwired Loo p and Auxiliary Power 1. 2. Select sensor location. Remove all power t o Central Controller before installing sensor. 3. Connec t hardwired loop sensor wire to the Central Controller.
STEP 14 Run the Phone Line for the Digital Communicator 1. 2. Locate the phone line protector block. Install an RJ3lX block. do not mount the RJ3lX inside of the Central Controller. Follow all manufactured installation procedures. 3. possible, to the phone protector block and attach at both ends.
STEP 15 Install Optional Auxiliary Sounding Devices Select location for th e auxiliary sounding device Follow manufacturer installation procedures Connect the auxiliary sounding device to the Central .
Using The High Power Siren Rela y Module HARD ~-60 0 m A TOTAL- : I :A,, j ;; / S;;;;R W ’ RED ‘ : ’ ‘ IRE, VDC) j 7 (12VDC) ‘““ r ” (12VDC) ““ ‘ , ~ 2 3 C;ANNy 6. 7 8 j 1 2 3 4 5 6 7 10 d 11 12 13 14 15 16 17 BLUE + BROWN LYll ‘ s all II 12 VOLT STANDBY BATTERY 11 .
If the auxiliary sounding device requires more powcr than 450 MA, then install the High Power Siren Rela y Module Use the following procedure: 1. Peel off the tape backing. 2. Mount anywhere on the inside of the Central controller plastic housing. Do not mount on a metal surface.
STEP 17 Progra m the Transmitters Identification Codes An easy way to program the transmitters is to begin by setting the I.D. code for each one while you have them all together (in the kitchen of wherever you’re working). That way, since you can look at them ail at once, you’ll be sure not to give the same I.
Use the Zone Locator Card (shown below) to record (IN PENCIL PLEAS E - neatly and accurately) the I.D. codes of each transmitter as soon as you se t them.
Prepare the Wireless Remote/Transmitter for Programming 1. 2. Remove the backplate from the Wireless Remote/Transmitter Press the release tab on the transmitter backpiate.
. Set House Code/Option DIP Switches: Switche s 1 - 7 set the house code. Switch 8 sets the selectable sensor loop zone to either of the following O N = interior OFF = perimeter delayed . Set ID/Options DIP switches: Switches 1 - 5 set the transmitter identification number.
. Set the security code: a. Determine the 3-digit security code. Consult the customer before programming the security code to determine: _ The number of different security codes to be used . For example, the customer may want a different number for each transmitter or one number to be used throughout the system.
b. Plug each security code post into the slot for the number desired. Blue Wiie = First Number White Wire = Second Number Yellow Wire = Third Number NOTE: The proper wire sequence is easy to remember since the alphabetical order of the colors is the same as the order of the numbers they represent: 1st = B 2nd = W 3rd = Y 3.
b. Pres s the Test/Demo key on the Central Controller. The digital display will show a n "88". C. Within 2 seconds , touch all four keys on the Central Controller at the same time (Messages, Clear Display , Cancel, and Test/Demo). The digital display will show a ‘ CC ” .
Prepare the Keypa d Transmitter 1. Remove the backplate from the Keypad Transmitter. Press the release tab on the backplate. 2. Program the Keypad Transmitter. . Set the House Code DIP switches. . Set the ID/Options DIP switches: Switches 1 - 5 set the transmitter identification number.
Switch 7 sets the batter y saver function to either of the following: ON = battery saver on OFF = battery saver off Switch 8 should be set ON for high security to allow for the RF link test.
_ Set the security code: a. Determine the 3-digit security code. b. Plug each security code pos t into the slot for the number desired. Blue Wire = First Number White Wiie = Second Number Yello w Wire.
3. Test battery, under load, then connect the 9-volt battery. It should register 9 volts on your meter. Check the current draw. 4. Log the transmitter location on the central controller Zone Locator Card. 5. Temporarily place the transmitter in the area that it will be mounted.
Prepare the Universal Transmitter 1. Remove the backplate from the Universal Transmitter. Press up on the tab at the bottom of the housing. 2. Program the Universal Transmitter. . Set the House Code DIP switches. . Set the ID/Options DIP switches: Switche s 1 - 5 se t the transmitter identification number.
AUDIBLE PANIC INTERIOR OPEN LOOP 11 Switch 7 sets the battery save r function to either of th e following: ON = battery saver on OFF = battery saver off Switch 8 sets the sensor loop zone to either of th e following: O N = interior OFF = perimeter instant Switch 9 sets the function of the button on the front of th e Universal Transmitter.
Switches 10 and 11 set the type of alarm that the transmitter wil l send. Use the chart below to set the transmitter to Intrusion, Fire, Auxiliary, or Environmental. Switc h 12 determines whether or not the transmitter is supervised. A supervised transmitter checks in to the central Controller.
3. Test the voltage of you r 9-volt battery. Connect the battery. Check the current draw. 4. Log the transmitter location on th e Centra l Controller Zone Locator Card. 5. Temporarily place the transmitter in the area that it will be mounted. Use double-sided tape, if necessary.
Prepare th e Passive Infrared Transmitter (PI R T) 1. Verify the proper location for the PIRT. Apply the information presented in the Pre-Installation section on PIRT placement considerations. 2. Remov e PIRT housing. Press the release tab on the top to the housing.
5. Program the PIRT. NOTE: The PIRT should be held upside-down for the DIP switches to be oriented properly for programming. . Set House Code DIP switches. . Set ID/Options DIP switches: _ Switches 1 - 5 set the transmitter identification number. Switch 6 should be placed in the OFF position.
Switch 8 sets the transmitter sensor zone to either of the following: ON = interior OFF = perimeter instant Stitches 9 - 12 should be set to the ON position. pscH8$E TRANSMITTER DIP SWITCHES l "Active ” Post o n PIRT Circuit Board 6. Test the battery voitage.
8. Activate the LED by connecting the walk-test LED plug to the ‘ Active ” post on the PIRT circuit board. 9 . Check to see that DIP switch 7 is set in the OFF position. 10. Temporaril y mount the PIRT with double-sided tape. 11. Perform th e PIRT RF link test.
Prepar e th e Supervised Smoke Detector Transmitter 1. Verify the proper location for the Supervised Smoke Detector Transmitter. Use the information presented in the Installation Information section to help determine the correct location. 2. Open the detector front housing.
Use the chart below to set the 3-DIGIT smoke detector identification number. Onl y I.D. number s 2 4 through 31 are available for the Smoke Detectors. l,D Switch ring 3 ;$t.ns~; 1 24 ON ON ON 25 OFF ON ON 26 ON OFF ON 27 OFF OFF ON 26 ON ON OFF 29 OFF ON OFF 30 ON OFF OFF 31 OFF OFF OFF 4.
a. Use a pencil to press the Test button on the detector. Hold it down until you hear an alarm tone (approximatety 20 seconds). b. Listen for the proper number of indication beeps from the Central Controller. C . Check the Central Controller to verify that the proper transmitter I.
STEP 18 Mount th e Transmitters Moun t Wireless Remote/Transmitter 1. Mount the sensor to be used with the transmitter. (Follow the sensor manufacturer ’ s instructions.) 2. Thread sensor wires through the Wireless Remote/Transmitter backplate. Too much wire can cause the housing to seat improperly and cause false alarms.
4. 5. Connect sensor wires to the screw terminals on the backplate for th e desired type of senso r loop. If wiring the 24-hour sensor loop, the preinstalled jumper must be removed. Otherwise, make sure the 24-hour jumper is firmly installed. Connect the snap caps or spade lug wires to the screw terminals.
Moun t Keypad Transmitter 7. Perform the sensor activation RF test. This test is used to verify the correct functioning of the sensor and the RF link of the mounted transmitter. a. Activat e th e sensor. b. Listen for the proper number of beeps from the Central Controller.
7. Perform the sensor activation RF test. a. Activate the sensor. b. Listen for the proper number of beeps from the Centra l ControIIer. C. Check the Central Controller t o verify that the proper transmitter I.D. number appears. d. Check the status LEDs on the Central Controller for more information.
3. Mount the backplate. Be careful not to over-tighten the backplate screws. 4. Connect sensor wires, if used, to the screw terminals on the backplate. 5. Connect the snap caps or spade lug wires to the screw terminals. 6. Attach the front housing. 7.
Universal Transmitter Applications UNIVERSAL TRANSMITTER SENSOR LOOP: PANI C APPLlCATiONS SEL ECTABLE I OOP PROGRAMMING UNIVERSAL TRANSMITTER SENSOR LOOP: AUXILIARY APPLlCATlONS SE L ECTABLE LOOP PROGRAMMING PORTABLE BACKPLATE 1. OPEN CIRCUIT . 2. PAN IC BUTTON ENABLED 3.
Mount Passive Infrared Transmitter (PIRT) 1. Mount the PIRT backpiate with #6 screws. For a corner mount, use the mounting guides on the angled sides of the backplate. 2. Attach the front housing to the backplate. Allow the unit several minutes to stabilize.
Moun t Supervised Smoke Detector Transmitter 1. Remov e the back bracket from the detector. Use the release tab marked "Press" to remove back for mounting. 2. Mount the detector bracket. 3. Install the detector onto the bracket. 4. Perform second R F link test.
STEP 20 Program the wireless Siren/Controller Set the House Code/Option DIP SWITCHES: - Switches 1 - 7 set the House Code. - Switch 8 determines whether the Witless Siren/Controller ’ s internal sounder is on or off during an intrusio n alarm. ON = Silent OFF = Sound - Switch 9 should ALWAYS be ON.
Run optiona l auxiliary sounding device wires to the Wireless Siren/Controller CAUTION: The Wireless Siren/Controller provides a total of 450 MA for auxiliary sounding devices. Do NOT exceed this total. If an auxiliary sounding device(s) is being installed, connect the wires to the terminals labeled ‘ ONE O R TWO EXTERNAL SIRENS ” .
Connect the Battery Use th e 9-volt battery that’s included. BE SURE TO TEST IT FIRST! Enter the Wireless Siren /Controller Test Mode 1. Press the internal ‘CANCEL’ button. Hold it for 6 SECONDS. The Wireless Siren/Controller will beep once when the button is pressed and again when it goes into the TEST MODE.
STEP 21 Perform the System Test System Test Intrusion Transmitters 1. Arm the system to the Away ststate using a wireless Remote/Transmitter. 2. Trip each intrusion transmitter. 3. Listen for the appropriate alarm sounding patterns from the the Central Controller.
System Tes t 24-Hour Zone Transmitters RF Scanner 1. Trip each 24-Hour zone transmitter (tire, panic, auxiliary, environmental). 2. Listen for the appropriat e alarm sounding patterns from the Central Controller. 3. Reset the alarm system (disarm or cancel).
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AT&T 8000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AT&T 8000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AT&T 8000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AT&T 8000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AT&T 8000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AT&T 8000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AT&T 8000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AT&T 8000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.