Manuel d'utilisation / d'entretien du produit ne-c801 du fabricant Omron
Aller à la page of 30
Compressor Nebuliser Mode l NE-C801 • Instruction Manual • Mode d’em ploi • Gebrauchsanweisu ng • Manuale di ist ruzioni • Manual de instruccion es • Gebruiksaanwijzin g • РУ К ОВОДСТВО ПО ЭКСПЛУ А Т АЦ ИИ TM TM EN FR DE IT ES IM-NE-C 801S- E-03-1 1/2011 948739 9-6C NL AR RU NE-C8 01S-E_B _M02_10 0827.
2 Contents Befo re using the de vice Introduction ............ ................... ............. ............. ................... ............. .......... 3 Intended use ................. ............. ............. ................... ............. .
3 EN Introduction Thank you for purchas ing the OMRON COMP AIR. This pr oduct was develope d in conj unction with resp iratory th erapis ts for the succe ssful treatmen t of asthma, chr onic bronchi tis, aller gies and othe r respirato ry disord ers. T he compr essor for ces air to the neb uliser k it.
4 Import ant safety instructions Read all the inform ation in the instruct ion manual and any other literat ure in clude d in the box before using the device.
5 Important safety instr uctions EN • Use o nly original OMRON A C adapter . U se of u nsupport ed AC adap ter may damage th e dev ice. • Do not operate t he dev ice with a dam aged p ower cord o r plug. • Keep the pow er cord awa y from h eated sur faces.
6 Importan t safety instructio ns • Do not block th e slit be tween th e cap and the inh alation ai r inlet . • Do not use a microwa ve oven o r hair dr yer to d ry the ne bulisin g parts. • Approv ed for h uman use o nly . • If the device is used continu ously , the serv ice life of the dev ice may be shor tened.
7 EN 1. Know your unit Air T ube (PVC, 100cm) Air T ube Connector Nebuliser Kit Holder Air Filter Cover *A ir f ilt er ins id e Power Connector Compress or (Main Unit) Cap Inhalation Air Inlet Inhalat.
8 1. Know your unit Accessories Compressor Nebuliser Model NE-C801 • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksa.
9 EN 2. Guide to using t he device Prep aring the Nebuliser for Use - Secti on 3 (p age 10-13) W arning: Clean and disinfec t the neb uliser ki t, mouthp iece and n osepiec e or mask s before using th.
10 3. Prep aring the nebuliser f or use W arning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the fi rst time after purchase, i f the device has not been used for a long period of time, or if more than one person uses the same device.
11 3. Preparing the nebuliser fo r use EN 3.2 Adding medication and ass embling the part s 1. Remo ve the mou thpiece a nd cap from the nebu lise r kit. 2. Remo ve the inh alation to p from the medicati on tan k. 1) Rotate the inh alatio n top anti-c lockwis e.
12 3. Preparin g the nebulis er for use 6. Attach the desired inhalati on attachment, as desc ribed be low . Attaching the mouthpiece 1) Attach the c ap to the i nhalat ion air inl et. 2) Attach the m outhpiece to the inh alatio n top. Attaching the nosepiece 1) Attach the c ap to the i nhalat ion air inl et.
13 3. Preparing the nebuliser fo r use EN 7. Attach the air tube. 1) T wist th e air tube pl ug sligh tly and p ush it firm ly into th e air tube connec tor on the compres sor . 2) T wist th e air tube pl ug sligh tly and p ush it firm ly into th e air tube connec tor on the medication tank.
14 4. T aking medication 1. Hold the nebul iser kit a s indic ated on the right. Caution: Do not t ilt the ne buliser kit at an angle of greater than 4 5° in all direction. Medication ma y flow into the mouth. 2. Press the powe r switc h to the on ( ) posi tion.
15 4. Tak ing me dica tion EN 3. Inhale m edic ation accor ding to y our doc tor ’s and/or he alth c are advi ser ’s instruct ions. Prepare the inhal ation attachme nt accordi ng to Sec tion 3 (page 12). Using the mouthpiece Inser t the mouthp iece into your mo uth and inhale the med ication breathing no rmally .
16 4. Takin g medication 4. When trea tment is com plete, turn th e power off. Check tha t there is no conden satio n or mois ture in the air tu be and unplug the device from the power outlet . W arning: Condensation may occur in the ai r tube. Do not store the air tub e while it cont a ins condensation or moisture.
17 EN 5. Cleaning and daily disinfecting 5.1 Cleani ng Follow ing the cleanin g instru ction s after each use will preven t any re mainin g medicat ion in t he tank from dr ying, re sulting i n the dev ice not ne bulisin g effectively and als o for preve nting infe ctions.
18 5. Clea ning and daily disinfectin g 7. If the co mpressor is dirty , wipe it clea n with a soft cloth moi stened with w ater or mild detergent. Caution: The compressor is not waterproof . 8. If the ou tside of the air tube is dirty , wipe it clean wi th a soft cloth moi stened with wate r or mild detergent.
19 5. Cle aning and daily disinfecting EN Handling t he V apori ser Head The vapor iser head i s an imp ortant part that is u sed to va porise medication. Be sure to obser ve the fol lowing pr ecautio ns when handling it. Caut ion: • Alway s wash the vapori ser head a f t er eac h use.
20 5. Clea ning and daily disinfectin g Use the table below as a guideli ne to selec t a metho d for disi nfecting. Part s Model Materials Mouthpie ce C28-3P-E PP Nosepi ece C28-7-E PP Nebuliser Kit S.
21 5. Cle aning and daily disinfecting EN O: app licab le ×: not applica ble * an exam ple of comme rcially availabl e disin fectant. Boiling Alcohol Sodi um hypoc hlo rit e Quatern ary ammonium Chlorhexidine Amphoteric surfact ant Disinfectin g etha nol Milton* (0.
22 6. Maintenance and storage T o keep your device in the best con dition and prote ct the device f rom damag e foll ow thes e dir ections : Caution: • Do not leav e the devi ce una ttended with infan ts or persons who canno t express thei r consent .
23 EN 7. Changing the air fi lter If the air filter has changed colou r , or has been used on aver age for m ore than 60 days , replace i t with a new one. 1. Pull the ai r filt er cov er of f the com pre ssor . 2. Chan ge the air fi lter . 3. Put the air filt er cover back in pl ace.
24 8. T roubleshooting Check th e followin g if your unit sh ould fa il during o perat ion. Y ou can also refer t o the pages of this m anual f or compl ete in structi ons. Note: If the suggest ed remedy doe s not solve the pr oblem, do not try to repair the devic e - no parts of the u nit ar e user ser viceab le.
25 EN 9. T echnic al dat a Notes: • Subjec t to techn ical mod ification witho ut prior not ice. • This OMRON prod uct is p roduced under the strict quality system of OMR ON HEAL THCARE Co., Ltd., Japan. • The device may not wo rk if the temperat ure and v oltage condi tions ar e different to those define d in the s pecific ations.
26 9. Te chnica l da ta T ech nical data for the OMRON NE -C801 Comp ressor with the OMRON V .V .T . (Virtua l V alve T echnology) Nebuliser kit: Result of cascade imp actor measure m ents for particle s ize** * Measured by OMRON HEAL THCA RE Co., Ltd.
27 9. Tech nical da ta EN Important information regar ding Electro Magnetic Compatibility (EMC) With the i ncreas ed num ber of ele ctronic devic es su ch as PC ’s and mobi le (ce llul ar) teleph ones, me dical devi ces in us e may be susceptib le to electro magnetic in terference fr om other devices .
28 9. Te chnica l da ta Correct Disposa l of This Product (Waste Elect rical & Ele ctronic Equipm ent) This ma rking sho wn on th e product or its literatur e, in dicates that it sho uld not be disposed of, with other hou sehold wa stes at the end o f its worki ng life.
29 EN 10. Optional p art s and accessori es O m r o n V. V. T . N e b u l i s e r K i t N-01 Set Model: C80 1S-NSET3-E Order No.: 951 5573-6 Air T ube (PVC, 100c m) Model: C801S-A TBP-E Order N o.: 951 5575-2 Mout hpiece Model: C28-3P-E Order N o.: 9956 273-5 Air T ube ( Sil i cone, 100 cm) Model: C28-6-E Order N o.
30 10. Opti onal parts and a ccessories Made in Ch ina Manufacturer OMRON HEAL THCARE Co., Lt d. 53, Kunot subo, T era do-cho, M uko, Kyoto , 617-0002 JAP AN EU-represent a tive OMRON HEAL THCARE EURO PE B.V . Scorpius 33, 2132 L R Hoofddorp, TH E NETHERLAND S www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omron ne-c801 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omron ne-c801 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omron ne-c801, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omron ne-c801 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omron ne-c801, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omron ne-c801.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omron ne-c801. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omron ne-c801 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.