Manuel d'utilisation / d'entretien du produit FR-M40 du fabricant 3M
Aller à la page of 22
1 FR- M40 Ser ies Full F acepie ce Air Purif ying R espira tor User Instructions for 3M™ FR-M40-10 Full Facepiec e Respirator (small), 3M™ FR-M40-20 Full Facepiece Respirator (medium) and 3M™ FR.
2 GE N E RA L SA F E TY I NF O R MA T I ON Inten ded Use The 3M™ FR-M40 Full Facep iece Respir ator is designed t o help provide respi ratory p rotect ion against cer tain a irb orn e cont ami nant s whe n used i n acco rda nce w ith a ll use a nd li mita tio n inst ruc tio ns and appli cable saf ety and heal th regula tions.
3 C A U T I O N • Cleanin g wi th so lvent s may de grade some respi rator compo nents an d re duce respira tor eff ec ti v en es s. See Maint enance and Cleaning s ectio n. • Inspect al l respi rator compon ents b efore each use to e nsure proper op erati ng co nditi ons.
4 Do Not Use For Atmos phere s with less than 19.5% oxygen, concent ratio ns of conta minan ts which are immedi ately dange rous to life or hea lth, a re unk nown o r when conce ntrat ions excee d the.
5 S-Special or Critical U se Instructio ns There is no NIOS H appr oval sc hedul e for che mical or biol ogica l warfa re agen ts; onl y the tea r agen ts CN & CS.
6 3M™ Spare Parts (Figures 3- 6) fi g . 3 fi g . 4 fi g . 5 fi g . 6 Pr od uc t Nu mb er Pr od uc t N am e FR- M40 -1 01 (a) H e ad H a r n e s s FR-M40-102 ( b ) Inhalation (Inlet) V alve Kit (incl.
7 fig . 19 fig . 20 fig . 21 fig . 22 fig . 23 Pro du ct Nu mb er Pr odu ct N ame W e i g h t FR-M40-1 (fig. 16) E y ep i ec e Outsert, Clear (2) 4.2 oz. (0.12 kg) FR-M40-2 (fig. 16 ) Eyepiece Outsert, Gray (2) 4.2 oz. (0.12 kg) FR-M40-3 (fig. 18) Quick D off Hood (Butyl Rubber Coated Fabric, Olive Drab) 8.
8 3M™ Combinatio n Cartridge/Filt ers fig . 7a fi g . 7 b Pro du ct Nu mb er Pro duc t Nam e W e i g h t FR-C2A1 (fig. 7a) Cartridge, Alumin um, Olive Drab 9.
9 IN ST R UC TI ON S FOR AS SE MB L Y AN D F I TT IN G For furth er i nfor mati on conce rnin g as semb ly a nd f itti ng, call 3M OH&ES D Te chni cal Serv ice Cartr idge (Figur e 8) fi g . 8 1. Screw the cart ridge into the f acepi ece inhala tion port.
10 4 . Remove t he side voicemitte r retainer by unscrewing counter clockwise using the D-r ing voice mitter remova l tool or a s tandard 1 3/1 6 x1 in ch D-ring or similar tool . 5 . Remove the side v oicemitter from the mas k assembly by pre ssing from t he inside of the mask as sembly.
11 Befo re you ente r a co ntami nate d atm osphe re we aring this resp irato r, yo u mus t ins pect the resp irato r, don the respira tor acc ordin g to the inst ructi ons prov ided wi th the compon ents of t he system you a re using a nd complete a U ser Seal Check.
12 Positive and Negative Pressure User Seal Checks Positive Pressure Seal Check (Figure 13) fig . 13 Close off the exhalation valve by pushing firmly on th e center of the exhala tion valve cover with t he heal of one hand. It may b e difficult to clos e the exhalation val ve completely , therefore you must bl ow out or exh ale hard.
13 Quantit ative Fit T esting (QNFT) can b e co nducted wit h 42 CFR 84 P 100 type fi lters. To conduct QNFT on the FR-M40 face piece, screw a 701 F ilter Adapter int o the filter inhal ation port in the fac epiece. Next, attach a 601 Q uantitativ e Fit T est Adap ter alon g with a 3 M 2000 Series P100 42 CFR 84 approved fi lter.
14 MA IN TE N AN CE AN D CL EA NI N G C A U T I O N Clean ing wit h solven ts may de grade some resp irato r compo nents and reduc e respi rator effect ivene ss. Insp ect all re spir ator co mpon ents be for e e ach use to ensur e p rop er opera ting co ndit ion s.
15 1 . The outserts ca n b e attached to the fa cepiec e b y f irst rolling th e r ubber ring up all ar ound the edge o f the outs ert. 2 . Posit ion t he outsert ove r the appro priat e eye ring and roll rubbe r ring dow n all aroun d the eye ring . 3 .
16 3M™FR- M40-5 Univer sal Second Skin, S 3M™ FR-M 40-6 Univ ersal Sec ond Skin, M/L (Fi gures 22 and 23) fig . 22 fig . 23 1 . Remove cartridge from facepiece (if applica bl e) . 2 . Remove the exhalation val ve cover from the facepiece (FR-M40-1 04).
17 Spare P arts 3M™ FR-M40-1 01 Head H arness (F igures 24 an d 2 5) fig . 24 fig . 25 1 . Leng then head har ness to it s ful l ex tent and then w ork tabs at the end s of the h ead h arne ss st raps out of buckles .
18 6 . To verify that the valve seat body ha s been properly re-installed, grasp the two little ta bs sticking straight up f rom the v alve seat body and try to tu rn th e en tire valve seat body in the port. If it turns freel y, th e valve seat body has been correctly re-installed.
19 3M TM 6889 Exhalation Valve Disk (Figure 30) fig . 30 1 . Remove external drink tu be fro m tab on exhalation valve c over, quick dis connect coupling from retaine r in exhalat ion v alve cover a nd ex halatio n val ve c over (see pre vious instructi ons f or 3 M FR- M40-104 exha lation valve c over).
20 1 . Inve rt he ad ha rness over fron t of mask asse mbly and la y the mask face down on a non-ab rasi ve surface with the exha lation valve closest to you. 2 . Gras p the i nter nal dr ink t ube at the d rink t ube c oupli ng an d pul l the i nter nal dr ink t ube aw ay fr om the cou pli ng.
21 1 . Re mo v e si d e voi cemitter retainer by unscrew ing cou nter c lockwise using the D-rin g side voi c e mi t t er remova l tool, or a st andard 1 3/1 6 x1 i nch D-ring o r similar tool. 2 . Remove the side voicemitt er f rom the mask by pressing from the inside of the mask assem bly.
22 4 . To in stall a new quick disconnect coupling lay the mask assembly fac e up. 5. Insert the quick disco nnect coupling int o the externa l drink tube and with a twisting mot ion, pres sing the drin k tube in place. The tube s hould ex tend ove r the n ipple en d of th e quick disconnect c oupling approxim ately 3 /4 inch (19 m m).
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté 3M FR-M40 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du 3M FR-M40 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation 3M FR-M40, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le 3M FR-M40 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le 3M FR-M40, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du 3M FR-M40.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le 3M FR-M40. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei 3M FR-M40 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.