M GT - 16 OWNER’S MANUAL 16-Channel Mini UHF Wireless Instrument System.
Contents 2 Introduction ............................................................................................................................. 2 Using this Manual .................................................................................
System Features MGT -16 System Features UHF wireless system for guitar/bass • 16 user -selectable PLL frequencies • for interference-free operation Up to 250’ operating range, line-of-sigh.
4 Quick User Controls Guide MGT -16 Instrument Receiver POWE R AC T 10 13 14 11 12 2 1 3 6 5 15 IR PO LO RX LEVE L CHANNE L 1 234 SQ OFF ON 7 8 9 16 4.
1. ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter 2. POWER SWITCH Select OFF/MUTE/ON (MUTE=power On, audio out put highly attenuated) 3. VOLUME CONTROL Adjusts the audio output level — at maximum setting the gain will be about +4dB over a direct instrument-to- cord-to-amp connection 4.
6 Quick User Controls Guide MT -16A/R Instrument T ransmitter 17. POWER SWITCH T o power transmitter Off/On 18. 15dB A TTENUATION P AD Select to r educe the input gain b y 15dB for hi gher level au dio input signals 19. INPUT ¼” PLUG Connect directly into guitar/bass output jack 20.
7 IR Sync Selected Frequency Download from MGT -16 Receiver to MT -16A/R T ransmitter (1) ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter (21) IR RECEPTOR SENSOR/WINDOW Infrared LED sensor for l inking the TX to the RX du ring IR frequency download.
powers the u nit and will not charge Ni MH rechargeable batteries if installed. F or battery operation the AC adapter must be disconnected. Note: For quietest optimal perf ormance, use the AC/DC adapter as battery operation raises the noise floor around 4 dB.
9 When the RF Signal LED (10) on the rec eiver lights up, the system frequency is properly synchronize d. T o change to a different frequency , reset the Frequency Select DIP Switches (4) and sync t he transmit ter again to the new selected frequency first, after turning the transmitte r off and th en on again.
10 trim-pot counterclockwise reduces overall system audi o output (t hus lowering distortion but raising background noise), while turning clockwise increases overall system audi o output (t hus lowering background noise but r aising disto rtion).
11 Specifications MGT -16 SYSTEM Frequency Response 50Hz–16kHz (-3dB) Dynamic Range 120dB Oscillating System Phase Lock Loop (PLL) T otal Harmonic Distortion (THD) <0.
Cautions and T roubleshooting 12 No or Low Audio If you are not getting audio through the system, carefully re-check all setups. Especially note that the receiver and transmitter must be set to operate on the same RF channel.
13 Miscellaneous T ips The receive r antennas should be ke pt • away from a ny metal su rfaces whene ver possible as they can r eflect away o r shield the incoming RF signal. When insert ing batteri es, make sur e they • are inserte d with the correct pola rity .
14 MGT -16 DIP-Switch Frequency Selection Chart Frequency Plan: 902.4MHz-923.7MHz (16 Channels) U.S. Channel Selection Frequency 9 913.9 10 914.0 11 916.0 12 917.9 13 919.7 14 920.0 15 921.1 16 923.7 Channel Selection Frequency 1 902.4 2 904.8 3 905.4 4 906.
15 One-Y ear Limited Warranty Nady Systems , Inc. warran ts to the ori ginal consume r purchaser t hat the unit is free from any defects in material or workmanship for a period of one year from the date of original retail purchase. If any such defect is discovered within the warranty period, Nady Systems, Inc.
6701 Shellmound Street | Emeryville, CA USA 94608 T 510.652.2411 | F 510.652.5075 | www .nady .com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Nady Systems MGT16A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Nady Systems MGT16A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Nady Systems MGT16A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Nady Systems MGT16A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Nady Systems MGT16A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Nady Systems MGT16A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Nady Systems MGT16A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Nady Systems MGT16A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.