FR
Micron Technology logo
Notice d'utilisation officielle

Micron Technology USB Camera

90 pages·4.2 MB·Appareil photo numérique·PDF·EN
Micron Technology USB Camera
Table des matières 77 sections SMX-M8xx Series USB2.0 Camera User Guide · Contents · Introduction · Camera Specifications · … AfficherMasquer
SMX-M8xx Series USB2.0 Camera User Guidep.1Contentsp.5Introductionp.9Camera Specificationsp.10SMX-M8xx Camera Kitp.13Installationp.15Automatic Camera Installationp.15Manual Hardware Installationp.19Removing the SMX-M8xx Camerap.22Removing the Softwarep.22Removing the Hardwarep.23Updating the Hardwarep.25Getting Startedp.27Sensor Controlp.31Exposurep.31Gainp.31Frequencyp.31Decimationp.32Viewport Settingsp.32Image Correctionp.33Color Balancep.33Color Correctionp.35Snapshotsp.37Snapshots Basicsp.37Switching Between Camerasp.39Camera Device Settingsp.41Camera Infop.41Color Modep.41Flip Imagep.42Average Framesp.42Max Exposurep.43Direct Access To Driver Frame Memoryp.43Enable Image Correctionp.43Display Video on Program Startupp.43Auto White Balance Hardwarep.43Auto White Balance Softwarep.44Frame Rate Controlp.44Output Bits per Pixel Controlp.45Median Filterp.45Limit Gainp.45Profilesp.47Capturingp.49Guidelines for Using TWAIN Driverp.53Overviewp.53Installationp.53How It Worksp.53Locationp.53Getting Image Using Scanner and Camera Wizardp.55Getting Image Using Scanp.60Getting Image from Camera Using Microsoft Paintp.62Menu Overviewp.65Filep.65Editp.65Devicep.65Helpp.66Keyboard Shortcutsp.67Main Keyboard Shortcuts Operationsp.67Toolbar Overviewp.69Main Toolbar Operationsp.69Basic Guidelines on Using the SMX-M8xx Series USB2.0 Camerasp.71Introductionp.71Camera Kitp.71Use of C-mount Adapter with and without IR-cut Filterp.73Overviewp.73IR-cut filter Characteristicsp.73When to Use the C-mount Adapter with IR-cut Filterp.74C-mount adapter with IR-cut filter use with the color camerasp.74C-mount adapter with IR-cut filter use with monochrome camerasp.75Using the SMX-M8xx Camera as CS-mountp.75Using the SMX-M8xx Camera as C-mountp.75Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mountp.76Use of Tripod Adapter with the SMX-M8xx Camerasp.78Camera Installation Troubleshooterp.81Camera was not Detected or Recognizedp.81Cannot Install the Hardwarep.85Figuresp.87Tablesp.89
Page 1 of the Micron Technology USB Camera user manual — U s e r G u i d e
Page 1 · cliquer pour agrandir
Page 1
Micron Technology USB Camera — SMX-M8xx Series USB2.0 Camera User Guide diagram (page 1)
Fig. 1 · SMX-M8xx Series USB2.0 Camera User Guide
Micron Technology USB Camera — SMX-M8xx Series USB2.0 Camera User Guide diagram (page 1)
Fig. 2 · SMX-M8xx Series USB2.0 Camera User Guide

U s e r G u i d e

SMX-M8xx Series USB2.0 Cameras

Page 2 of the Micron Technology USB Camera user manual — SMX-M8 XX S ERIES USB2.0 C AMERA
Page 2 · cliquer pour agrandir
Page 2

SMX-M8 XX S ERIES USB2.0 C AMERA

U SER G UIDE

Copyright © 2001-2006 Sumix Corporation

Page 3 of the Micron Technology USB Camera user manual — SMX-M8xx Series USB2.0 Camera User Guide
Page 3 · cliquer pour agrandir
Page 3

Revision 2.0

Copyright © 2006 Sumix Corporation

3403 Southwood Dr.

Tel.: (877)233-3385; Fax: (508) 300 5526

Emailcamera@ sumix.com

www.sumix.com

The information in this document is subject to change without notice. The software described in this document is furnished under a license and be used or copied only in accordance with the terms of such license.

Oceanside, CA 92054

Page 4 of the Micron Technology USB Camera user manual — SMX-M8xx Series USB2.0 Camera User Guide
Page 4 · cliquer pour agrandir
Page 4
Page 4 of the Micron Technology USB Camera user manual — SMX-M8xx Series USB2.0 Camera User Guide
Page 5 of the Micron Technology USB Camera user manual — Table des matières
Page 5 · Table des matières
Table des matières

Table des matières

SMX-M8xx Series USB2.0 Camera User Guidep.1Contentsp.5Introductionp.9Camera Specificationsp.10SMX-M8xx Camera Kitp.13Installationp.15Automatic Camera Installationp.15Manual Hardware Installationp.19Removing the SMX-M8xx Camerap.22Removing the Softwarep.22Removing the Hardwarep.23Updating the Hardwarep.25Getting Startedp.27Sensor Controlp.31Exposurep.31Gainp.31Frequencyp.31Decimationp.32Viewport Settingsp.32Image Correctionp.33Color Balancep.33Color Correctionp.35Snapshotsp.37Snapshots Basicsp.37Switching Between Camerasp.39Camera Device Settingsp.41Camera Infop.41Color Modep.41Flip Imagep.42Average Framesp.42Max Exposurep.43Direct Access To Driver Frame Memoryp.43Enable Image Correctionp.43Display Video on Program Startupp.43Auto White Balance Hardwarep.43Auto White Balance Softwarep.44Frame Rate Controlp.44Output Bits per Pixel Controlp.45Median Filterp.45Limit Gainp.45Profilesp.47Capturingp.49Guidelines for Using TWAIN Driverp.53Overviewp.53Installationp.53How It Worksp.53Locationp.53Getting Image Using Scanner and Camera Wizardp.55Getting Image Using Scanp.60Getting Image from Camera Using Microsoft Paintp.62Menu Overviewp.65Filep.65Editp.65Devicep.65Helpp.66Keyboard Shortcutsp.67Main Keyboard Shortcuts Operationsp.67Toolbar Overviewp.69Main Toolbar Operationsp.69Basic Guidelines on Using the SMX-M8xx Series USB2.0 Camerasp.71Introductionp.71Camera Kitp.71Use of C-mount Adapter with and without IR-cut Filterp.73Overviewp.73IR-cut filter Characteristicsp.73When to Use the C-mount Adapter with IR-cut Filterp.74C-mount adapter with IR-cut filter use with the color camerasp.74C-mount adapter with IR-cut filter use with monochrome camerasp.75Using the SMX-M8xx Camera as CS-mountp.75Using the SMX-M8xx Camera as C-mountp.75Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mountp.76Use of Tripod Adapter with the SMX-M8xx Camerasp.78Camera Installation Troubleshooterp.81Camera was not Detected or Recognizedp.81Cannot Install the Hardwarep.85Figuresp.87Tablesp.89
Page 9 of the Micron Technology USB Camera user manual — Chapter 1
Page 9 · cliquer pour agrandir
Page 9

Chapter 1

I NTRODUCTION

SMX-M8xx Series Cameras - are megapixel CMOS cameras with USB2.0 interface suitable for scientific and industrial applications.

The cameras are designed for capturing, streaming and storing high quality digital images.

The SMX-M8xx Series Cameras are available in three modifications:

  • SMX-M81M (1.3 Megapixel, monochrome)
  • SMX-M82C (2 Megapixel, color)
  • SMX-M83C (3 Megapixel, color)

All the SMX-M8xx Cameras feature:

  • Communication interface - USB2.0
  • Form factor - a duralumin housing with C/CS - mount interface

All the SMX-M8xx Cameras benefit:

  • High speed
  • Low power consumption
  • No external power supply required
  • Ease of use
  • Compact size

The programmable functions include viewport window settings, adjustable exposure time and gain, selectable sensor clock frequency and image decimation, flipping image horizontally and vertically. The SMX-M8xx Series Camera can be used in microscopy, video conferencing, webcasting, surveillance and security systems, etc.

Introduction:

Page 10 of the Micron Technology USB Camera user manual — Max Frame rate at resolution (24MHz) *
Page 10 · cliquer pour agrandir
Page 10

Camera Specifications

Table 1-1 Output Video and Camera Control Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

Maximum resolutions of output window

1280x1024, full resolution mode

1600 x 1200, full resolution mode

2048 x 1536, full resolution mode

Max Frame rate at resolution (24MHz) *

15 fps at 1280 x 1024 24 fps at 1024 x 768 37 fps at 800 x 600 40 fps at 768 x 576 54.7 fps at 640 x 480 89.5 fps at 400 x 400 166 fps at 320x240

10 fps at 1600x1200 14 fps at 1280 x 1024 22.7 fps at 1024 x 768 34.6 fps at 800 x 600 37 fps at 768 x 576 50 fps at 640 x 480 79.6 fps at 400 x 400 145 fps at 320x240

6 fps at 2048x1536 10 fps at 1600x1200 13.9 fps at 1280 x 1024 21.9 fps at 1024 x 768 33 fps at 800 x 600 35.7 fps at 768 x 576 48 fps at 640 x 480 75 fps at 400 x 400 138.5 fps at 320x240

Output bit per pixel Selectable, 8 bits or 10

Selectable, 8 bits or 10 bits

Selectable, 8 bits or 10 bits

Lookup table Software, converts 10 bits of imaging chip's ADC to 8 bits of output for user selected 8 bits mode

Software, converts 10 bits of imaging chip's ADC to 8 bits of output for user selected 8 bits mode

Software, converts 10 bits of imaging chip's ADC to 8 bits of output for user selected 8 bits mode

Pixel rates 12 MHz, 24 MHz 12 MHz, 24 MHz 12 MHz, 24 MHz

Exposure range 0.06 - 65.7 ms (24 MHz, 1280 x 1024, 1:1); More than 2 sec with fps decrease

0.07 - 96.91 ms (24 MHz, 1600 x 1024, 1:1); More than 2.5 sec with fps decrease

0.09 - 156.92 ms (24 MHz, 2048 x 1536, 1:1); More than 200 sec with fps decrease

Pixel Gain Control Programmable (Hardware): 48 gain levels from 1 to 15

Programmable (Hardware): 48 gain levels from 1 to 15 Gain controls for R, G, B: 48 gain levels from 1 to 15

Programmable (Hardware):161 gain levels from 1 to 128 Gain controls for R, G, B: 161 gain levels from 1 to 128

IntroductionCamera Specifications

bits

Page 11 of the Micron Technology USB Camera user manual — Camera Specifications
Page 11 · cliquer pour agrandir
Page 11

Table 1-1 Output Video and Camera Control Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

View port (from 1280 x 1024 to 8 x 8 with 2 pixels/2 lines step positioning) Frame Decimation (1:1, 1:2, 1:4, 1:8) Horizontal mirroring, hardware Vertical flipping, hardware

View port (from 1600 x 1200 to 8 x 8 with 2 pixels/2 lines step positioning) Frame Decimation (1:1, 1:2, 1:4, 1:8) Horizontal mirroring, hardware Vertical flipping, hardware

View port (from 2048 x 1536 to 8 x 8 with 2 pixels/2 lines step positioning) Frame Decimation 1:1, 1:2, 1:3, 1:4, 1:5, 1:6, 1:7, 1:8 Frame Binning: 1:1, 1:2, 1:3, 1:4 Horizontal mirroring, hardware Vertical flipping, hardware

Gamma, brightness and contrast control

Programmable with lookup table, software gamma correction

Programmable with lookup table, software gamma correction

Programmable with lookup table, software gamma correction

* Listed frame rate values at the defined resolutions are not the maximal possible. Increasing of frame rate

can be done by reducing the current Exposure value (the lower Exposure the higher frame rate), hiding the active video window from the display, running the camera with a fast speed computer, etc

Table 1-2 Imaging Chip Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

Type Mono inch 1.3 megapixel CMOS sensor manufactured by Micron Technology, Inc

Color inch 2 megapixel CMOS sensor manufactured by Micron Technology, Inc

Color inch 3 megapixel CMOS sensor manufactured by Micron Technology, Inc

Pixel Size 5.2 um x 5.2 um 4.2 um x 4.2 um 3.2 um x 3.2 um

Image Array Size 8.4 mm diagonal 8.4 mm diagonal 8.4 mm diagonal

Shutter Rolling Rolling Rolling (Optional Global Reset)

Scanning mode Progressive Progressive Progressive

ADC Resolution 10 bit 10 bit 10 bit

Sensitivity 2.1 V/lux-sec 1.2 V/lux-sec (550nm) >1.0 V/lux-sec (550nm)

Dynamic Range 68.2dB >61dB 61dB

IntroductionCamera Specifications

Output window modes

Page 12 of the Micron Technology USB Camera user manual — Camera Specifications
Page 12 · cliquer pour agrandir
Page 12

Table 1-3 Camera Electrical Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

Supply Voltage 5 V supplied by USB2.0 interface

5 V supplied by USB2.0 interface

5 V supplied by USB2.0 interface

Table 1-4 Camera Physical Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

0 to +70 C 0 to +60 C 0 to +60 C

Dimensions, L x D 46 x 31.5 mm 46 x 31.5 mm 46 x 31.5 mm

Lens Mount Type C/CS - mount C/CS - mount C/CS - mount

Table 1-5 Camera Interface Characteristics

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

Interface Type USB2.0, 480Mbps USB2.0, 480Mbps USB2.0, 480Mbps

Connector Type USB mini-B, 5 pin USB mini-B, 5 pin USB mini-B, 5 pin

Table 1-6 System Requirements

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

Windows XP Professional SP1or SP2 Windows Server 2003 SP1

Windows XP Professional SP1or SP2 Windows Server 2003 SP1

Windows XP Professional SP1or SP2 Windows Server 2003 SP1

Processor Pentium 4, 3 GHz or higher, HT or dual- core recommended

Pentium 4, 3 GHz or higher, HT or dual- core recommended

Pentium 4, 3 GHz or higher, HT or dual- core recommended

RAM 256MB, recommended 384Mb 256MB, recommended 384Mb 256MB, recommended 384Mb

Hard Disk Space 5 MB for installation plus additional space for captured images

5 MB for installation plus additional space for captured images

5 MB for installation plus additional space for captured images

Video 24 bit True Color, 8 MB video memory

24 bit True Color, 8 MB video memory

24 bit True Color, 8 MB video memory

IntroductionCamera Specifications
Show 4 more labels / short text on this page
Operating Temperature · Camera Housing material · Duralumin Duralumin Duralumin · Operating System
Page 13 of the Micron Technology USB Camera user manual — SMX-M8xx Camera Kit
Page 13 · cliquer pour agrandir
Page 13

Table 1-6 System Requirements

SMX-M81M Camera SMX-M82C Camera SMX-M83C Camera

USB USB2.0 Host Controller, recommended Intel integrated host controller

USB2.0 Host Controller, recommended Intel integrated host controller

USB2.0 Host Controller, recommended Intel integrated host controller

SMX-M8xx Camera Kit

The SMX-M8xx Camera Kit includes the following items:

  • The SMX-M8xx Series Camera
  • The SMX-M8xx Series USB2.0 Cameras Software Package which is available for downloading via the provided URL
  • USB A to USB mini-B cable (optional)
  • Tripod adapter (optional)
  • C-mount adapter with IR-cut filter (optional)
  • C-mount adapter (optional)
IntroductionSMX-M8xx Camera Kit
Page 14 of the Micron Technology USB Camera user manual — SMX-M8xx Camera Kit
Page 14 · cliquer pour agrandir
Page 14
IntroductionSMX-M8xx Camera Kit
Page 15 of the Micron Technology USB Camera user manual — Automatic Camera Installation
Page 15 · cliquer pour agrandir
Page 15

Chapter 2

I NSTALLATION

Install (if needed) USB2.0 adapter card into your PC. Install all required drivers. Refer to your USB2.0 adapter card manufacturer's User Guide for detailed instructions for hardware and software installation.

Automatic Camera Installation

Browse to the downloaded via URL SMXM8X_CD folder. Open setup.exe to start the SMX-M8xx Series USB2.0 Software Package installation.

Welcome to the SMX-M8x USB2.0 Camera Software Setup Wizard will appear (see Figure 2-1 Welcome to the SMX-M8xx USB2.0 Camera Software Setup Wizard window).

Micron Technology USB Camera — Automatic Camera Installation diagram (page 15)
Fig. 3 · Automatic Camera Installation

Figure 2-1 Welcome to the SMX-M8xx USB2.0 Camera Software Setup Wizard window

In order to proceed with the SMX-M8xx USB2.0 Camera Software Package installation click the Next button.

On the third step the SMX-M8xx USB2.0 Camera Software Setup Wizard will determine whether your system configuration meets system requirements of the SMX- M8xx USB2.0 Camera (see Table 1-6 System Requirements).

The following system information will be displayed:

  • OS version
  • USB2.0 Host Controller availability
  • Memory Size
InstallationAutomatic Camera Installation
Page 16 of the Micron Technology USB Camera user manual — Installation
Page 16 · cliquer pour agrandir
Page 16
  • CPU Speed

Each point of the system information will be marked by its status according to the compatibility with the SMX-M8xx USB2.0 Camera.

The current system information will be marked as one of the following:

  • Ok (Found - for USB2.0 Host Controller)
  • Warning
  • Fail

System information that completely satisfy the SMX-M8xx USB2.0 Camera requirements will be marked by Ok (for USB2.0 Host Controller - Found). In this case the SMX-M8xx USB2.0 Camera will work properly (see Figure 2-2 Setup Wizard, System information window: the case of satisfactory system configuration).

Micron Technology USB Camera — Installation diagram (page 16)
Fig. 4 · Installation

Figure 2-2 Setup Wizard, System information window: the case of satisfactory system configuration

The Warning status will be displayed in cases when the SMX-M8xx USB2.0 Camera can be installed but might not work properly (see Figure 2-3 Setup Wizard, System information window: the case of warning system configuration).

InstallationAutomatic Camera Installation
Page 17 of the Micron Technology USB Camera user manual — Installation
Page 17 · cliquer pour agrandir
Page 17
Micron Technology USB Camera — Installation diagram (page 17)
Fig. 5 · Installation

Figure 2-3 Setup Wizard, System information window: the case of warning system configuration

The Fail status will be displayed in cases when the SMX-M8xx USB2.0 Camera will not work at all with current system configuration (see Figure 2-4 The SMX-M8xx Setup Wizard: failed to detect USB2.0 Host Controller).

Micron Technology USB Camera — Installation diagram (page 17)
Fig. 6 · Installation

Figure 2-4 The SMX-M8xx Setup Wizard: failed to detect USB2.0 Host Controller

In any of these cases click the Next button.

If the system information was marked as Warning or Fail, the Error message will appear and you will be asked to update your system configuration (see Figure 2-5 Error message box when the SMX-M8xx Setup Wizard failed to detect USB2.0 Host Controller).

InstallationAutomatic Camera Installation
Page 18 of the Micron Technology USB Camera user manual — Installation
Page 18 · cliquer pour agrandir
Page 18
Micron Technology USB Camera — Installation diagram (page 18)
Fig. 7 · Installation

Figure 2-5 Error message box when the SMX-M8xx Setup Wizard failed to detect USB2.0 Host Controller

It is strongly recommended to update the system configuration in the case of Fail status, otherwise the device will not work at all

If all the system information was marked as Ok, the next window of the SMX-M8xx USB2.0 Camera Setup Wizard will appear. Follow easy-on-screen recommendations and when ready press the Install button (see Figure 2-6 The SMX-M8xx Setup Wizard: ready to install).

Micron Technology USB Camera — Installation diagram (page 18)
Fig. 8 · Installation

Figure 2-6 The SMX-M8xx Setup Wizard: ready to install

InstallationAutomatic Camera Installation
Page 19 of the Micron Technology USB Camera user manual — Manual Hardware Installation
Page 19 · cliquer pour agrandir
Page 19

The SMX-M8xx USB2.0 Camera Setup Wizard will install the SMX-M8xx USB2.0 Camera Software Package and USB2.0 camera driver.

When done, in the Completing the SMX-M8xx USB2.0 Camera Software Setup Wizard window additionally choose:

  • Install a TWAIN driver ( see chapter “Guidelines for Using TWAIN Driver” )
  • Create Desk Top icon
  • Create Quick Launch icon
  • Launch the SMX-M8xx USB2.0 Camera Application Program after finishing

Click the Finish button and wait while TWAIN and/or Direct Show drivers are installed, if it was selected (see Figure 2-7 Completing the SMX M8x USB2.0 Camera Software Setup Wizard).

Micron Technology USB Camera — Manual Hardware Installation diagram (page 19)
Fig. 9 · Manual Hardware Installation

Figure 2-7 Completing the SMX M8x USB2.0 Camera Software Setup Wizard

Manual Hardware Installation

The camera installation using the Found New Hardware Wizard on Windows XP operating system is described below. On Windows 2000 the installation wizard slightly differs, although, it is built on the same principles.

InstallationManual Hardware Installation
Page 20 of the Micron Technology USB Camera user manual — Manual Hardware Installation
Page 20 · cliquer pour agrandir
Page 20

Connect the camera to your computer with the USB cable. The Found New Hardware message will appear in the right corner of the Taskbar (see Figure 2-8 Found New Hardware message in the Task bar).

Micron Technology USB Camera — Manual Hardware Installation diagram (page 20)
Fig. 10 · Manual Hardware Installation

Figure 2-8 Found New Hardware message in the Task bar

Then the Found New Hardware Wizard will start up (see Figure 2-9 Found New Hardware Wizard: welcome window).

Micron Technology USB Camera — Manual Hardware Installation diagram (page 20)
Fig. 11 · Manual Hardware Installation

Figure 2-9 Found New Hardware Wizard: welcome window

Leave as it is suggested by default 'Install the software automatically (Recommended)' and click the Next button to go to the next step of the device installation.

The Found New Hardware Wizard automatically will search for the software for your video device (see Figure 2-10 Found New hardware Wizard: searching for needed files).

InstallationManual Hardware Installation
Page 21 of the Micron Technology USB Camera user manual — Manual Hardware Installation
Page 21 · cliquer pour agrandir
Page 21
Micron Technology USB Camera — Manual Hardware Installation diagram (page 21)
Fig. 12 · Manual Hardware Installation

Figure 2-10 Found New hardware Wizard: searching for needed files

You may be prompted for manufacturer's disk to be inserted (see Figure 2-11 Found New Hardware Wizard: Insert Disk message box).

Micron Technology USB Camera — Manual Hardware Installation diagram (page 21)
Fig. 13 · Manual Hardware Installation

Figure 2-11 Found New Hardware Wizard: Insert Disk message box

Browse to the SMXM8X.inf file which is normally located in the Drivers folder of the SMXM8X_CD (see Figure 2-12 Found New Hardware Wizard: Files Needed message box).

Micron Technology USB Camera — Manual Hardware Installation diagram (page 21)
Fig. 14 · Manual Hardware Installation

I Figure 2-12 Found New Hardware Wizard: Files Needed message box

When done, the Driver Files Search Results window will be displayed (see Figure 2-13 Completing the Found New Hardware Wizard).

InstallationManual Hardware Installation
Page 22 of the Micron Technology USB Camera user manual — Removing the SMX-M8xx Camera
Page 22 · cliquer pour agrandir
Page 22
Micron Technology USB Camera — Removing the SMX-M8xx Camera diagram (page 22)
Fig. 15 · Removing the SMX-M8xx Camera

Figure 2-13 Completing the Found New Hardware Wizard

Press the Finish button. Windows will warn you that the SMX-M8xx Camera driver does not contain Microsoft digital signature. In order to proceed with the camera installation click Continue anyway (Yes in Windows 2000) in the Digital Signature window (see Figure 2-14 Software has not passed Windows Logo Testing message box).

Micron Technology USB Camera — Removing the SMX-M8xx Camera diagram (page 22)
Fig. 16 · Removing the SMX-M8xx Camera

Figure 2-14 Software has not passed Windows Logo Testing message box

Removing the SMX-M8xx Camera

To remove the SMX-M8xx USB2.0 Camera Software Package click Start > Control Panel > Add/Remove Programs (Start >Settings> Control panel > Add or Remove Programs under Windows 2000). Find the SMX-M8x USB2.0 Camera Software in the registered applications list (see Figure 2-15 Removing the SMXM8xx USB2.0 Camera Software) and click the Change/Remove button. A message to confirm the removal will appear (see Figure 2-16 Removal Application Prompt).

InstallationRemoving the SMX-M8xx Camera

Removing the Software

Page 23 of the Micron Technology USB Camera user manual — Removing the Hardware
Page 23 · cliquer pour agrandir
Page 23
Micron Technology USB Camera — Removing the Hardware diagram (page 23)
Fig. 17 · Removing the Hardware

Figure 2-15 Removing the SMXM8xx USB2.0 Camera Software

Micron Technology USB Camera — Removing the Hardware diagram (page 23)
Fig. 18 · Removing the Hardware

Figure 2-16 Removal Application Prompt

To remove the SMXM8xx Camera Application, click Yes. The SMX-M8xx Camera Software will be removed from your computer.

To remove the SMX-M8xx USB2.0 Camera from your computer, connect the camera and click Start > Control panel > System (under Windows 2000 click Start > Settings > Control Panel > System).

In the System Properties window, select the Hardware tab and click the Device Manager button (see Figure 2-17 System Properties window).

InstallationRemoving the SMX-M8xx Camera

Removing the Hardware

Page 24 of the Micron Technology USB Camera user manual — Removing the Hardware
Page 24 · cliquer pour agrandir
Page 24
Micron Technology USB Camera — Removing the Hardware diagram (page 24)
Fig. 19 · Removing the Hardware

Figure 2-17 System Properties window

The Device Manager window will open. Choose Imaging devices and do the following: 1. Highlight the SMX-M8xx Series USB2.0 Camera 2. Right-click and select Uninstall (see Figure 2-18 Device Manager window: removing the SMX-M8xx Series USB2.0 Camera) 3. Click OK in the Confirm Device Removal prompt (see Figure 2-19 Confirm Device Removal prompt)

The SMX-M8xx USB2.0 Camera will be removed from your computer.

InstallationRemoving the SMX-M8xx Camera
Page 25 of the Micron Technology USB Camera user manual — Updating the Hardware
Page 25 · cliquer pour agrandir
Page 25
Micron Technology USB Camera — Updating the Hardware diagram (page 25)
Fig. 20 · Updating the Hardware
Figure 2-18 Device Manager windowremoving the SMX-M8xx Series USB2.0 Camera
Micron Technology USB Camera — Updating the Hardware diagram (page 25)
Fig. 21 · Updating the Hardware

Figure 2-19 Confirm Device Removal prompt

Updating the Hardware

To update the SMX-M8xx USB2.0 Camera with a newer driver, do the following: 1. Connect the camera to your computer 2. Open the Device Manager window (Start> Settings> Control Panel> System> Hard- ware tab) 3. Click Imaging devices, then SMX-M8xx Series USB2.0 Camera 4. Right-click and select Update Driver... (see Figure 2-20 Device Manager window: updat- ing of the SMX-M8xx USB2.0 Camera driver) 5. Run the Hardware Update Wizard that will appear - follow easy-on-screen instruc- tions that the Wizard will suggest (see Figure 2-21 Hardware Update Wizard: welcome window)

InstallationUpdating the Hardware
Page 26 of the Micron Technology USB Camera user manual — Updating the Hardware
Page 26 · cliquer pour agrandir
Page 26
Micron Technology USB Camera — Updating the Hardware diagram (page 26)
Fig. 22 · Updating the Hardware
Figure 2-20 Device Manager windowupdating of the SMX-M8xx USB2.0 Camera driver
Micron Technology USB Camera — Updating the Hardware diagram (page 26)
Fig. 23 · Updating the Hardware
Figure 2-21 Hardware Update Wizardwelcome window
InstallationUpdating the Hardware
Page 27 of the Micron Technology USB Camera user manual — Chapter 3
Page 27 · cliquer pour agrandir
Page 27

Chapter 3

G ETTING S TARTED

To start the SMX-M8xx camera, connect it with the USB cable to your computer. Since the camera is already installed (see chapter “Automatic Camera Installation” , see chapter “Manual Hardware Installation” ), the corresponding icon should appear in the right corner of the Taskbar:

To start the SMX-M8X Camera Application open Start> Programs> Sumix > SMX- M8X USB2.0 Camera > SMX-M8X> USB2.0 Camera Application Program (see Figure 3-1 Opening the SMX-M8xx Camera Software).

Micron Technology USB Camera — Chapter 3 diagram (page 27)
Fig. 24 · Chapter 3

Figure 3-1 Opening the SMX-M8xx Camera Software

Getting Started

Page 28 of the Micron Technology USB Camera user manual — Getting Started
Page 28 · cliquer pour agrandir
Page 28

The SMX-M8X Camera Application will start and you will see its main window (see Figure 3-2 The SMX-M8X Camera Application main window outlook).

Micron Technology USB Camera — Getting Started diagram (page 28)
Fig. 25 · Getting Started

Figure 3-2 The SMX-M8X Camera Application main window outlook

To see the video captured by the camera, press F5 or click the Start Video button:

The View window will appear (see Figure 3-3 The SMX-M8X View).

Getting Started

Page 29 of the Micron Technology USB Camera user manual — Getting Started
Page 29 · cliquer pour agrandir
Page 29
Micron Technology USB Camera — Getting Started diagram (page 29)
Fig. 26 · Getting Started

Figure 3-3 The SMX-M8X View

The SMX-M8xx Camera Application consists of 3 main parts:

  • Application main window
  • Histogram
  • Device Settings window

Application main window contain:

  • Sensor Controls, Image Correction
  • Color Balance and Color Correction Controls (for color models only)
  • Snapshot options

Histogram is reflecting all color settings that were done with the camera.

Device Settings window consists of:

  • Standard camera information
  • Color mode changing
  • Image flipping
  • Averaging frames
  • Exposure limiting
  • Frame rate controlling
  • Standard program options
  • 8/10 bit modes

Getting Started

Page 30 of the Micron Technology USB Camera user manual — Getting Started
Page 30 · cliquer pour agrandir
Page 30
  • Limit Gain 10
  • Filtering

Getting Started

Page 31 of the Micron Technology USB Camera user manual — Frequency
Page 31 · cliquer pour agrandir
Page 31

Chapter 4

S ENSOR C ONTROL

Exposure

The camera Exposure parameter is similar to exposure notion in photography. It defines time for which the sensor elements are gathering the energy of light.

Use the Exposure slider to adjust the camera exposure time. The current exposure time in milliseconds (ms) is displayed above the control. This value depends on viewport height, decimation and sensor frequency.

To perform Autoexposure, in the Device menu select the Auto Exposure command or simply press E keyboard.

Gain

Use the Gain controls to change the signal gain of the sensor. Increasing Gain is reasonable when light condition is poor and increasing time of exposure does not help. For color models Gain can be controlled independently for Red, Green and Blue channels (R, G, B).

Checking the Lock Ratio checkbox allows controlling gain on three channels simultaneously keeping the fixed R, G, B gain ratio.

All the Gain sliders control the camera's hardware gain amplifier. The R, G and B gain sliders control the software gain for each color channel.

Use the 'White balance (Hard)' menu item (Device> White Balance (Hard) or the 'Alt+W' keyboard shortcut to balance Gain of all three channels so they are equally intense.

Frequency

This control defines the pixel clock frequency of the sensor. The lower Frequency, the higher maximum possible Exposure time and the lower Frame Rate (see chapter “Frame Rate Control” ). Use the dropdown menu (near the Gain and Exposure controls) to define Frequency.

Sensor ControlExposure
Page 32 of the Micron Technology USB Camera user manual — Viewport Settings
Page 32 · cliquer pour agrandir
Page 32

Decimation

Use the Decimation control to decimate (sub-sample) the picture by 2, 4, etc. The decimation means excluding pixels and rows from the scan process (e.g. every second pixel and second row for the 1:2 decimation). This mode thus allows viewing the full picture at the higher Frame Rate (see chapter “Frame Rate Control” ). The decimation can be used for preview, when the full 1600x1200 image displayed as 800x600 with the frame rate twice higher. Use its dropdown menu to change Decimation.

Viewport Settings

Viewport is a rectangular area of the sensor on which the image is scanned. It can have variable size, from the smallest area of 8x8 pixels to the full field of view of the sensor. The smaller the size of the Viewport, the faster the scan process, and the higher Frame Rate (see chapter “Frame Rate Control” ). To open the Viewport Settings dialog (see Figure 4-1 Viewport Setting dialog: the case of the SMX-M82C Camera), press Alt+V or click the corresponding button on the toolbar:

Micron Technology USB Camera — Viewport Settings diagram (page 32)
Fig. 27 · Viewport Settings
Figure 4-1 Viewport Setting dialogthe case of the SMX-M82C Camera

The blue rectangle represents the current viewport window related to the full possible field of view. Drag the rectangle across the full resolution area for the viewport panning. The changes are displayed in the View window immediately.

Use the boxes in the bottom part to set the viewport offset and size manually and click the Apply button to apply the settings. The values should be divisible by 8 and will be rounded and applied automatically within 2 seconds after last keystroke.

Sensor ControlDecimation
Page 33 of the Micron Technology USB Camera user manual — Color Balance
Page 33 · cliquer pour agrandir
Page 33

Use one of the radio buttons on the Predefined control to set one of the predefined viewport sizes. The Viewport rectangle position may also be changed by dragging the video image in the View window.

Image Correction

The Image Correction controls are designed for setting up the camera's Brightness, Contrast and Gamma (see Figure 3-2 The SMX-M8X Camera Application main window outlook).

This correction is done programmatically by the camera firmware using the conversion (look-up) table of the values. The correction does not affect any electrical settings of the camera. To use the Image Correction controls, check the Enable command - Brightness, Contrast and Gamma become editable.

The default values of Brightness, Contrast and Gamma are set to 0; 0; 1, 00, respectively.

You can restore the default values of the Image Correction controls on any step of changes: simply click the Default button on the Image Correction tab.

The Best button, if applied, activates application to transform the look-up table of 8 and10 bit to increase the dynamic range.

With every change of any image correction controls, you can view a graphical interpretation of the dependence of the image's changes on the changes of the Image Correction controls (see Figure 3-2 The SMX-M8X Camera Application main window outlook).

Color Balance

The Color Balance controls are designed to adjust the ratio of the main induced color components (Red, Green and Blue) on the image that is displayed by the camera software.

This correction is done on the software level and does not affect any electrical settings of the camera (see Figure 4-2 The SMX-M8X Camera Application Color Balance Controls).

Sensor ControlImage Correction
Page 34 of the Micron Technology USB Camera user manual — Image Correction
Page 34 · cliquer pour agrandir
Page 34
Micron Technology USB Camera — Image Correction diagram (page 34)
Fig. 28 · Image Correction

Figure 4-2 The SMX-M8X Camera Application Color Balance Controls

To use the Color Balance controls, check the Enable command - the R, G and B sliders becomes editable.

Use the White Balance (Soft) button for balancing white color (same can be done on Device> White Balance (Soft) or with the 'W' keyboard accelerator) in the Color Balance tab.

The Default button restores the default values of the Color Balance controls: 1, 00; 1, 00; 1, 00, respectively.

A single step of each Color Balance control is 10 times smaller than R, G,

B (Gain) of Sensor Controls, so all changes of Color Balance are performed with more exactness than using R, G, B (Gain) of Sensor Controls.

Sensor ControlColor Balance
Page 35 of the Micron Technology USB Camera user manual — Color Correction
Page 35 · cliquer pour agrandir
Page 35

Color Correction

The Color Correction controls are designed to adjust the intensity of the color properties (Brightness, Contrast and Saturation) of the image that is displayed by the camera.

This correction is also done on the software level and does not affect any electrical settings of the camera.

Check the Enable command to make the Color Correction controls available.

Use the Default button to restore the default values of Brightness, Contrast and Saturation - 0,0; 1,00; 1,00, respectively (see Figure 4-3 The SMX-M8X Camera Application Color Correction Controls).

Micron Technology USB Camera — Color Correction diagram (page 35)
Fig. 29 · Color Correction

Figure 4-3 The SMX-M8X Camera Application Color Correction Controls

Sensor ControlColor Correction
Page 36 of the Micron Technology USB Camera user manual — Color Correction
Page 36 · cliquer pour agrandir
Page 36
Micron Technology USB Camera — Color Correction diagram (page 36)
Fig. 30 · Color Correction

Figure 4-4 Application’s main window outlook when using the SMX-M81M Camera

Sensor ControlColor Correction
Page 37 of the Micron Technology USB Camera user manual — Snapshots Basics
Page 37 · cliquer pour agrandir
Page 37

Chapter 5

S NAPSHOTS

Snapshots Basics

The SMX-M8xx Series Camera has two modes of operation: Video and Snapshot. When the camera is not in the Video mode, it is possible to take a Snapshot - to capture a still image. For the SMX-M8xx series cameras a Snapshot can be triggered by software only.

Video is the normal mode when the camera is giving out the image data. The mode is On when View window is open. The Snapshot mode forces the camera to capture the still image (a single frame).

To take a Snapshot from the camera, use the Snapshot section of the SMX-M8X Series USB2.0 Camera window. Remember that you need to Stop Video (Shift+F5) in order to turn on the Snapshot mode.

The Snapshot button starts the snapshot process.

To take a Snapshot using software trigger, do the following: 1. Turn the video mode off(Shift+F5) 2. Set Exposure, Gain, Viewport, etc 3. Click the Snapshot button or press F9

The Snapshot View window will open (see Figure 5-1 The Snapshot View window).

Micron Technology USB Camera — Snapshots Basics diagram (page 37)
Fig. 31 · Snapshots Basics

Figure 5-1 The Snapshot View window

SnapshotsSnapshots Basics
Page 38 of the Micron Technology USB Camera user manual — Snapshots
Page 38 · cliquer pour agrandir
Page 38

For a continuous sequence of Snapshots, use the Loop option (see Figure 5-2 Running the Snapshot Loop mode): 1. Check the Loop checkbox 2. Click the Snapshot button

Micron Technology USB Camera — Snapshots diagram (page 38)
Fig. 32 · Snapshots

Figure 5-2 Running the Snapshot Loop mode

The stream of continuous snapshots will be displayed in the Snapshot View window (see Figure 5-1 The Snapshot View window). This mode can be useful to adjust the picture parameters for the Snapshot mode.

Click Cancel or uncheck Loop to stop capturing.

Timeout - defines time during which the SMX-M8X Software is waiting for a Snapshot.

Use the spin buttons to increase or decrease time of waiting for a Snapshot.

SnapshotsSnapshots Basics
Page 39 of the Micron Technology USB Camera user manual — Chapter 6
Page 39 · cliquer pour agrandir
Page 39

Chapter 6

S WITCHING B ETWEEN C AMERAS

If you have more than one SMX-M8xx Series Camera connected to your PC, the SMX- M8X Camera Application allows you to switch between them.

To switch between the multiple cameras, do the following: 1. In the Device menu, select the Switch Multiple command. The 'Choose a Cam- era…' window will appear (see Figure 6-1 Choosing active camera).

Micron Technology USB Camera — Chapter 6 diagram (page 39)
Fig. 33 · Chapter 6

Figure 6-1 Choosing active camera

2. From the list of available cameras select the one you want and click OK .

Switching Between Cameras

Page 40 of the Micron Technology USB Camera user manual — Switching Between Cameras
Page 40 · cliquer pour agrandir
Page 40

Switching Between Cameras

Page 41 of the Micron Technology USB Camera user manual — Color Mode
Page 41 · cliquer pour agrandir
Page 41

Chapter 7

C AMERA D EVICE S ETTINGS

The Device Settings dialog is activated with Alt+S or by selecting Settings…in the Device menu.

Micron Technology USB Camera — Chapter 7 diagram (page 41)
Fig. 34 · Chapter 7

Figure 7-1 Device Settings window for the SMX-M8xC Cameras

Camera Info

The Camera Info section contains information about the currently installed camera. It consists of:

  • The Camera type - the type of the camera that is connected
  • Maximal resolution (depends on the camera type)
  • ID of the camera

Color Mode

The Color Mode section defines rules for decoding source pixels stream from the sensor and transforming it into the output image. This control is available for the color models only:

  • The Monochrome mode forces transformation of sensor pixels data into monochrome stream
Camera Device SettingsCamera Info
Page 42 of the Micron Technology USB Camera user manual — Average Frames
Page 42 · cliquer pour agrandir
Page 42
  • The Nearest Color mode: the Bayer matrix from sensor is transformed into destination stream using the Nearest Color algorithm (the fastest algorithm that gives the worst image quality (compared to other algorithms)
  • The Bilinear mode: the Bayer matrix from sensor is transformed into destination stream using Bilinear algorithm (slower algorithm that gives better quality)
  • The Laplacian mode: the Bayer matrix from sensor is transformed into destination stream using Linear Interpolation with Laplacian second-order correction terms (the slowest algorithm that gives the best quality)
Micron Technology USB Camera — Flip Image diagram (page 42)
Fig. 35 · Flip Image

Figure 7-2 Device Settings window for the SMX-M81M Cameras

Flip Image

Use Flip Image controls to flip the image horizontally and/or vertically

  • Horizontal flipping is done by the camera software (as a result, frame rate may decrease, see chapter “Frame Rate Control” )
  • Vertical flipping is done by the camera hardware

Average Frames

The Average Frames controls are used to increase the image quality by compensating the random noise of the sensor

There are two averaging modes:

  • Last N frames : the currently displayed frame is the average of the last N frames. The picture is updated every frame
Camera Device SettingsFlip Image
Page 43 of the Micron Technology USB Camera user manual — Auto White Balance Hardware
Page 43 · cliquer pour agrandir
Page 43
  • Pack N Frames : the currently displayed frame is the average of the last N frames. The picture is updated every Nth frame

Max Exposure

The Max Exposure scales the exposure slider bar. This option is useful to setup the short exposure time.

To limit the maximal value of Exposure, do the following: 1. Enable the Limit Max Exposure command 2. Enter in the field the new maximal value of Exposure 3. Click the Set button

The maximal value of Exposure should be change to the one you entered.

Direct Access To Driver Frame Memory

The Direct Access To Driver Frame Memory option can be used to reduce CPU load by providing direct pointer to the driver frame memory instead of copying the frame to the user buffer. See the API documentation for the details.

Enable Image Correction

Enable Image Correction enables Brightness, Contrast and Gamma of the Image Correction controls.

Display Video on Program Startup

Checked Display Video on Program Startup starts the video display immediately after the program starts - there is no need to click the Start Video button.

Auto White Balance Hardware

Checked Auto White Balance Hardware performs White Balance (Hard) automatically every time when you move the Brightness, Contrast and Gamma sliders of the Image Corrections tab.

Camera Device SettingsMax Exposure
Page 44 of the Micron Technology USB Camera user manual — Frame Rate Control
Page 44 · cliquer pour agrandir
Page 44

Auto White Balance Software

Checked Auto White Balance Software performs White Balance (Soft) automatically every time when you move the Brightness, Contrast and Gamma sliders of the Image Corrections tab.

Frame Rate Control

The speed of the camera is measured in fps (frames per second). The value means the number of frames (images) given by the camera per second. In the SMX-M8X Camera Software the option of controlling the current number of frames per second is called Frame Rate Control.

You can see the frame rate value in the right corner of the status bar in the main window of the SMX-M8X Camera Application.

To open the Frame Rate Control window, click the Frame Rate… button in the Device Settings window. The Frame Rate Control window will open (see Figure 7-3 Frame Rate Control window).

Micron Technology USB Camera — Frame Rate Control diagram (page 44)
Fig. 36 · Frame Rate Control

Figure 7-3 Frame Rate Control window

The Set Default button sets the default value of frame rate for the camera with current settings. The default value is flashed in every camera and is applying automatically when the camera's settings are changed.

The Set Maximum button sets the maximal possible value of frame rate for the camera with current settings.

To change the Frame Rate value manually, do the following: 1. Open the Frame Rate Control window 2. In the Frame Rate field enter the value you need 3. Click Set

The current frame rate value should change according to the one you entered in the Frame Rate Control window. Check it when running video: the frame rate value will be displayed in the right corner of the status bar of the main application window.

To restore the maximal or default value of frame rate, do the following:

Camera Device SettingsAuto White Balance Software
Page 45 of the Micron Technology USB Camera user manual — Limit Gain
Page 45 · cliquer pour agrandir
Page 45
1. Click the Frame Rate… button to open the Frame Rate Control window 2. Click the Set Maximum button to get the maximal value or click the Set Default button to get the default value 3. Close the window
Micron Technology USB Camera — Output Bits per Pixel Control diagram (page 45)
Fig. 37 · Output Bits per Pixel Control

Figure 7-4 Warning message of the Frame Rate Control window

Output Bits per Pixel Control

10 bit - enables the software to transmit 10 bit images from the camera as opposed to regular 8 bit.

Median Filter

Median filter - turns on pixel averaging. The brightness of every single pixel becomes affected by the brightness of its neighbor pixels and the whole image becomes smoother.

Limit Gain

Limit Gain 10 - limits maximal value of Gain to 10.

Camera Device SettingsOutput Bits per Pixel Control
Page 46 of the Micron Technology USB Camera user manual — Output Bits per Pixel Control
Page 46 · cliquer pour agrandir
Page 46
Camera Device SettingsLimit Gain
Page 47 of the Micron Technology USB Camera user manual — Chapter 8
Page 47 · cliquer pour agrandir
Page 47

Chapter 8

P ROFILES

The SMX-M8X Camera Application automatically stores all the camera and interface settings on exit and restores them on startup.

Also you can store current settings in the Profile files (*.pro) and load them whenever you need. Profiles are program settings saved as files. The number of stored profiles is not limited.

To save current settings to a profile, press Ctrl+S or in the File menu select the Save Profile command. To load a profile, press Ctrl+O or in the File menu select the Open Profile command.

Profiles

Page 48 of the Micron Technology USB Camera user manual — Profiles
Page 48 · cliquer pour agrandir
Page 48

Profiles

Page 49 of the Micron Technology USB Camera user manual — Chapter 9
Page 49 · cliquer pour agrandir
Page 49

Chapter 9

C APTURING

The SMX-M8X Camera Application allows user to capture images from the camera and

to store them as BMP or TIFF files.

To open the Capture Options dialog, do one of the following:

  • Press Alt+C
  • Open File>Capture Options…

The SMX-M8X Capture Options window will open (see Figure 9-1 SMX-M8X Capture Options window).

Micron Technology USB Camera — Chapter 9 diagram (page 49)
Fig. 38 · Chapter 9

Figure 9-1 SMX-M8X Capture Options window

The captured files are stored in the folder that can be selected in the Picture File Store Folder field.

The files are named automatically by combining the corresponding File Name Prefix and numerical value that is calculated by the number of last captured file + 1; for example, if the last captured file found is "FRAME_15.BMP" then the next file will be named as "FRAME_16.BMP". The file name prefixes for single frames and frame sequences can be set independently.

The Limits section allows controlling the sequence capture parameters.

For example, there will be a sequence of 5 frames (the 'Limit sequence count to' field) captured one by one every second (1000ms, the 'Capture a frame every' field, see Figure 9-1 SMX-M8X Capture Options window).

Capturing

Page 50 of the Micron Technology USB Camera user manual — Capturing
Page 50 · cliquer pour agrandir
Page 50

To perform the single frame capture procedure, press F2.

To perform the frame sequence capture procedure, press F3. To stop the sequence capture, stop the video stream by clicking the Stop Video button:

Sequence recording is automatically stopped when the number of saved frames reaches the sequence count limit.

The Snapshot Save Only option allows saving snapshots without showing it on the screen.

When this option is selected and the command to save snapshot is given, snapshot will be not shown on the screen but saved in the specified folder (the 'Picture File Store Folder' field).

You can save the video stream from the SMX-M8xx camera to .avi file. Start saving video by pressing F4 or the Save Video toolbar button:

Using the Stop Video button will stop the saving video process.

You can also take advantage of the faster video saving method invoked by the Save Video To Memory (Shift+F4) button:

When you click the Stop Video button, capture will stop and the SMX-M8X Application will flush the .smx file to the specified folder (the 'Picture File Store Folder' field). This file can be replayed and converted to .avi with the SMXView utility that comes with the standard SMX-M8X software package. Saving video directly to memory can slow down the camera's output visualization but this method insures that no frames are missed from the saved file.

Use the Save Video to Memory option to limit the number of grabbed frames when save video to the memory (the 'Capture Limit' field).

Capturing

Page 51 of the Micron Technology USB Camera user manual — Capturing
Page 51 · cliquer pour agrandir
Page 51

Captured file can be saved as BMP or TIFF image file.

Capturing with BMP format saves any 8 bit or 10 bit image as 8 bit BMP image.

Capturing with TIFF format saves 8 bit image as 8 bit TIFF image and 10 bit image as

10 bit TIFF image.

Use the dropdown menu near the TIFF radio button to specify saving TIFF image with or without compression.

  • NONE - to save image with TIFF format without compression
  • LZW - to save image with TIFF format with LZW (Lemple-Zif-Welch) - lossless type of compression, supported by TIFF format

Capturing

Page 52 of the Micron Technology USB Camera user manual — Capturing
Page 52 · cliquer pour agrandir
Page 52

Capturing

Page 53 of the Micron Technology USB Camera user manual — How It Works
Page 53 · cliquer pour agrandir
Page 53

Chapter 10

G UIDELINES FOR U SING TWAIN D RIVER

Overview

To get a picture from the SMX-M8xx Camera you can use the Scanners and Cameras operation - the standard Window's Administrative Tool (Start> Control Panel>Scanners and Cameras).

You can also use almost any of the image editing programs to get the image from the SMX-M8xx Camera using Scanners and Cameras. This action is available in almost all image editing programs.

The information in this section of the document is based on the image editor that is always available in Windows XP - Microsoft Paint.

To use the SMX-M8xx Camera for getting images, you should first install the required software - TWAIN Driver.

Installation and use of TWAIN Driver requires that the needed hardware for the camera use is already installed (see chapter “Installation” ).

Installation

If the TWAIN Driver was installed during the SMX-M8x USB2.0 Camera Software Package installation (see chapter “Automatic Camera Installation” ), it is ready to be used.

If the TWAIN Driver was not installed during the SMX-M8x USB2.0 Camera Software Package installation (see chapter “Automatic Camera Installation” ), browse to the Sumix folder where the SMX-M8xx USB2.0 Camera was installed and open the \SMX-M8X USB2.0 Camera\Drivers\TWAIN folder. In order to install the TWAIN Driver run the SMXM8WIA application file. Wait a few minutes for the driver installation to complete.

TWAIN Driver is installed and ready to be used.

How It Works

Open the Control Panel window (Start>Control Panel) and open Scanners and Cameras (see Figure 10-1 Scanners and Cameras in the Control Panel window).

Guidelines for Using TWAIN Driver

Location

Page 54 of the Micron Technology USB Camera user manual — Guidelines for Using TWAIN Driver
Page 54 · cliquer pour agrandir
Page 54
Micron Technology USB Camera — Guidelines for Using TWAIN Driver diagram (page 54)
Fig. 39 · Guidelines for Using TWAIN Driver

Figure 10-1 Scanners and Cameras in the Control Panel window

Since TWAIN Driver is already installed, the SMX-M8X Series USB2.0 Camera WIA should be available (see Figure 10-2 Scanners and Cameras).

Guidelines for Using TWAIN Driver

Page 55 of the Micron Technology USB Camera user manual — Getting Image Using Scanner and Camera Wizard
Page 55 · cliquer pour agrandir
Page 55
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 55)
Fig. 40 · Getting Image Using Scanner and Camera Wizard

Figure 10-2 Scanners and Cameras

Now you can use the SMX-M8X Series USB2.0 Camera WIA to get the image from your camera.

Getting Image Using Scanner and Camera Wizard

To get the image using the Scanner and Camera Wizard, do the following: 1. Connect the SMX-M81M, SMX-M82C or SMX-M83C USB2.0 Camera to your com- puter 2. Open Control Panel>Scanners and Cameras 3. Select the SMX-M8X USB2.0 Camera WIA and do one of the following:

  • Right-click and select Get picture using Scanner Wizard ( see Figure 10-3 Selecting Scanner Wizard for getting image from camera )
  • Double-click the selected

Welcome to the Scanner and Camera Wizard will appear (see Figure 10-4 The Scanner

and Camera Wizard welcome window)

Guidelines for Using TWAIN Driver

Page 56 of the Micron Technology USB Camera user manual — Getting Image Using Scanner and Camera Wizard
Page 56 · cliquer pour agrandir
Page 56
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 56)
Fig. 41 · Getting Image Using Scanner and Camera Wizard

Figure 10-3 Selecting Scanner Wizard for getting image from camera

Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 56)
Fig. 42 · Getting Image Using Scanner and Camera Wizard

Figure 10-4 The Scanner and Camera Wizard welcome window

4. Click the Next button to go to the next step of the Scanner and Camera Wizard ( see Figure 10-5 Scanner and Camera Wizard: selecting scanning preferences )

Guidelines for Using TWAIN Driver

Page 57 of the Micron Technology USB Camera user manual — Getting Image Using Scanner and Camera Wizard
Page 57 · cliquer pour agrandir
Page 57
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 57)
Fig. 43 · Getting Image Using Scanner and Camera Wizard

Figure 10-5 Scanner and Camera Wizard: selecting scanning preferences

5. Select Picture Type and adjust the image's settings ( see Figure 10-5 Scanner and Camera Wizard: selecting scanning preferences ):
  • Color picture - to get the color image
  • Grayscale picture - to get the black-and-white image
  • Click the Custom Settings button to adjust properties of the image ( see Figure 106 Scanner and Camera Wizard: Advanced Properties window )
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 57)
Fig. 44 · Getting Image Using Scanner and Camera Wizard

Figure 10-6 Scanner and Camera Wizard: Advanced Properties window

Guidelines for Using TWAIN Driver

Page 58 of the Micron Technology USB Camera user manual — Getting Image Using Scanner and Camera Wizard
Page 58 · cliquer pour agrandir
Page 58
6. Click the Preview button to view the image from the camera to be scanned ( see Figure 10-7 Scanner and Camera Wizard: previewing )
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 58)
Fig. 45 · Getting Image Using Scanner and Camera Wizard

Figure 10-7 Scanner and Camera Wizard: previewing

7. Resize the image if needed 8. Click Next to go to the next step of the Scanner and Camera Wizard ( see Figure 108 Scanner and Camera Wizard: picture name and destination window )
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 58)
Fig. 46 · Getting Image Using Scanner and Camera Wizard

Figure 10-8 Scanner and Camera Wizard: picture name and destination window

Guidelines for Using TWAIN Driver

Page 59 of the Micron Technology USB Camera user manual — Getting Image Using Scanner and Camera Wizard
Page 59 · cliquer pour agrandir
Page 59
9. Input the name, select file format and choose the location where you want to save your picture 10. Click the Next button - the Scanner and Camera Wizard starts scanning your picture ( see Figure 10-9 Scanner and Camera Wizard: scanning picture )
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 59)
Fig. 47 · Getting Image Using Scanner and Camera Wizard

Figure 10-9 Scanner and Camera Wizard: scanning picture

11. After the Wizard finishes scanning a picture, you will be asked for other options of the picture. Select the last option ( see Figure 10-10 Scanner and Camera Wizard: other options ) and click Next
Micron Technology USB Camera — Getting Image Using Scanner and Camera Wizard diagram (page 59)
Fig. 48 · Getting Image Using Scanner and Camera Wizard

Figure 10-10 Scanner and Camera Wizard: other options

Guidelines for Using TWAIN Driver

Page 60 of the Micron Technology USB Camera user manual — Getting Image Using Scan
Page 60 · cliquer pour agrandir
Page 60
12. View the last window of the Scanner and Camera Wizard and click the Finish button ( see Figure 10-11 Completing the Scanner and Camera Wizard window )
Micron Technology USB Camera — Getting Image Using Scan diagram (page 60)
Fig. 49 · Getting Image Using Scan

Figure 10-11 Completing the Scanner and Camera Wizard window

Microsoft Windows will open the folder, where you saved the scanned image.

Getting Image Using Scan

To get the image using Scan, do the following: 1. Connect the SMX-M81M, SMX-M82C or SMX-M83C USB2.0 Camera to your com- puter 2. Open Control Panel>Scanners and Cameras 3. Select the SMX-M8X USB2.0 Camera WIA and right-click. Select Scan (see Figure 10- 12 Scanners and Cameras: selecting Scan), as a result, a window with a list of available programs will appear - the programs that are installed on your computer, to launch for Scanning the image (see Figure 10-13 “Select the program to launch for Scanning” window)

Guidelines for Using TWAIN Driver

Page 61 of the Micron Technology USB Camera user manual — Getting Image Using Scan
Page 61 · cliquer pour agrandir
Page 61
Micron Technology USB Camera — Getting Image Using Scan diagram (page 61)
Fig. 50 · Getting Image Using Scan
Figure 10-12 Scanners and Camerasselecting Scan
Micron Technology USB Camera — Getting Image Using Scan diagram (page 61)
Fig. 51 · Getting Image Using Scan

Figure 10-13 “Select the program to launch for Scanning” window

Note: Some image editing programs that can be also used for scanning images might not be present in the list that is shown (see Figure 10-13 “Select the program to launch for Scanning” window). It might be due to the current operating system's settings or the image editing program configuration. For more information, see Help Topics of Windows operating system about Scanners and Cameras or Help Topics of the corresponding program

4. Select the program most suitable for you and click the OK button. The selected program will open and Scan Using SMX-M8X Series USB2.0 Camera WIA will open ( see Figure 10-14 Scan using SMX-M8X Series USB2.0 Camera WIA window )

Guidelines for Using TWAIN Driver

Page 62 of the Micron Technology USB Camera user manual — Getting Image from Camera Using Microsoft Paint
Page 62 · cliquer pour agrandir
Page 62
Micron Technology USB Camera — Getting Image from Camera Using Microsoft Paint diagram (page 62)
Fig. 52 · Getting Image from Camera Using Microsoft Paint

Figure 10-14 Scan using SMX-M8X Series USB2.0 Camera WIA window

5. Select Color or Grayscale picture or click the Adjust the quality of the scanned picture link to change the image's settings. Click the Preview button to preview the image to be scanned 6. When ready, click the Scan button - your image editor will start scanning and will show the scanned image in the current program’s window

Getting Image from Camera Using Microsoft Paint

To get the image from the camera using Microsoft Paint program, do the following: 1. Open Microsoft Paint (Start>All Programs>Accessories>Paint) 2. Connect the SMX-M81M, SMX-M82C or SMX-M83C USB2.0 Camera to your com- puter 3. In Microsoft Paint open File>From Scanner or Camera… - Scan Using SMX-M8X Series USB2.0 Camera WIA will open (see Figure 10-15 Getting image from camera using Microsoft Paint program)

Guidelines for Using TWAIN Driver

Page 63 of the Micron Technology USB Camera user manual — Getting Image from Camera Using Microsoft Paint
Page 63 · cliquer pour agrandir
Page 63
Micron Technology USB Camera — Getting Image from Camera Using Microsoft Paint diagram (page 63)
Fig. 53 · Getting Image from Camera Using Microsoft Paint

m Figure 10-15 Getting image from camera using Microsoft Paint program

4. Adjust the image's settings, click Preview to view the image that is scanned ( see Figure 10-15 Getting image from camera using Microsoft Paint program ) 5. When ready, click the Scan button 6. When done, save the scanned image ( see Figure 10-16 Microsoft Paint: Image, received after scanning )

Guidelines for Using TWAIN Driver

Page 64 of the Micron Technology USB Camera user manual — Getting Image from Camera Using Microsoft Paint
Page 64 · cliquer pour agrandir
Page 64
Micron Technology USB Camera — Getting Image from Camera Using Microsoft Paint diagram (page 64)
Fig. 54 · Getting Image from Camera Using Microsoft Paint
Figure 10-16 Microsoft PaintImage, received after scanning

Guidelines for Using TWAIN Driver

Page 65 of the Micron Technology USB Camera user manual — Device
Page 65 · cliquer pour agrandir
Page 65

Appendix 1

M ENU O VERVIEW

The Main menu includes three command groups described below.

File

Save Frame (F2) - saves a single frame as .bmp file to a location specified in Capture Options

Save Sequence (F3) - saves a sequence of frames to a location specified in Capture Options

Save Video (F4) - saves video as a video file to a specific location specified in Capture Options

Save Video To Memory (Shift + F4) - starts saving video to memory to a location specified in Capture Options

Capture Options… (Alt+C) - opens the Capture Options window

Load Profile (Ctrl+O) - opens the Load Camera Profile window

Save Profile (Ctrl+S) - saves all settings to Profile

Exit - closes the application

Edit

Copy (Ctrl+C) - copies an image from the camera to buffer

Device

Start Video (F5) - starts video stream

Stop Video (Shift+F5) - stops video stream

Viewport Settings…(Alt + V) - opens the Viewport Settings window

Auto Exposure (E) - performs auto exposure

White Balance (Soft) (W) - performs white balancing on software level

White Balance (Hard) (Alt+W) - performs white balancing on Hardware level

Histogram (H) - opens the Histogram view

Snapshot (F9) - saves single snapshot as .bmp file to a location specified in Capture Options

Menu OverviewFile
Page 66 of the Micron Technology USB Camera user manual — Help
Page 66 · cliquer pour agrandir
Page 66

Zoom In (Num +) - zooms in view

Zoom (Out Num -) - zooms out view

Original Size Num * - returns view to the Zoom=1x

Switch Multiple… - opens the Choose a Camera… window

Settings… (Alt+S) - opens the Device Settings window

Help

Help (F1) - opens the application help window

Version Info - opens window with the version information

About - opens the 'About' window

Menu OverviewHelp
Page 67 of the Micron Technology USB Camera user manual — Main Keyboard Shortcuts Operations
Page 67 · cliquer pour agrandir
Page 67

Appendix 2

K EYBOARD S HORTCUTS

Main Keyboard Shortcuts Operations

Table 2-1 Main Keyboard shortcut operations

F2 Captures a frame to bitmap file

F3 Captures a sequence of frames to bitmap files

F4 Captures a sequence of frames to AVI file

Shift + F4 Capture a sequence of frames to the memory

F5 Starts live video display in the View window

Shift+F5 Stops live video display and closes the View window

F9 Takes a snapshot

F12 Brings up the Main window when displaying the live video

Esc The same as Shift + F5, stops the video

Ctrl + O Opens Camera Profile

Ctrl + S Stores Camera Profile

Ctrl+C Copies an image from the camera to buffer

Alt + C Brings up the Capture Options window

Alt + S Brings up the Device Settings window

Alt + V Brings up the Viewport Settings window

H Brings up the Histogram

W Performs White Balance (Soft) using Color Balance

Alt + W Performs White Balance (Hard) using Gain Controls

Numpad +/- Zoom In/Zoom Out the picture in the View window

Numpad * Restores the picture in the View window to its original (100%) size

Keyboard ShortcutsMain Keyboard Shortcuts Operations

Keyboard operations Description · F1 Help

Page 68 of the Micron Technology USB Camera user manual — Keyboard Shortcuts
Page 68 · cliquer pour agrandir
Page 68
Keyboard ShortcutsMain Keyboard Shortcuts Operations
Page 69 of the Micron Technology USB Camera user manual — Main Toolbar Operations
Page 69 · cliquer pour agrandir
Page 69

Appendix 3

T OOLBAR O VERVIEW

Main Toolbar Operations

The most popular menu commands are duplicated on the application toolbar:

Starts live video display in the View window

Stops live video display and closes the View window

Brings up the Viewport Setup Dialog

Captures a frame to BMP/TIFF file

Captures a sequence of frames to BMP/TIFF files

Starts saving Video to a file

Starts saving Video to memory

Toolbar OverviewMain Toolbar Operations
Page 70 of the Micron Technology USB Camera user manual — Toolbar Overview
Page 70 · cliquer pour agrandir
Page 70
Toolbar OverviewMain Toolbar Operations
Page 71 of the Micron Technology USB Camera user manual — Introduction
Page 71 · cliquer pour agrandir
Page 71

Appendix 4

BASIC GUIDELINES ON USING THE SMX-M8XX SERIES USB2.0 CAMERAS

Introduction

The SMX-M8xx Series Cameras - are megapixel CMOS cameras with USB2.0 interface.

The SMX-M8xx Series Cameras are available in three modifications:

  • SMX-M81M (1.3 Megapixel, monochrome)
  • SMX-M82C (2 Megapixel, color)
  • SMX-M83C (3 Megapixel, color)

All the SMX-M8xx cameras feature small size and C/CS-mount form factor.

The SMX-M8xx cameras are supplied with C-mount adapter and/or C-mount adapter with IR-cut filter for converting CS-mount to C-mount.

The SMX-M8xx Camera Kit includes:

  • SMX-M8xx Series Camera:
Micron Technology USB Camera — Introduction diagram (page 71)
Fig. 55 · Introduction
  • The SMX-M8xx Series USB2.0 Cameras Software Package which is available for downloading via the provided URL
  • USB A to USB mini-B cable (optional):

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Camera Kit

Page 72 of the Micron Technology USB Camera user manual — Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras
Page 72 · cliquer pour agrandir
Page 72
Micron Technology USB Camera — Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras diagram (page 72)
Fig. 56 · Basic Guidelines on Using the SMX-M8xx Series USB2.0…
  • Tripod adapter (optional):
Micron Technology USB Camera — Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras diagram (page 72)
Fig. 57 · Basic Guidelines on Using the SMX-M8xx Series USB2.0…
  • C-mount adapter with IR-cut filter (optional):
Micron Technology USB Camera — Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras diagram (page 72)
Fig. 58 · Basic Guidelines on Using the SMX-M8xx Series USB2.0…
  • C-mount adapter (optional):

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 73 of the Micron Technology USB Camera user manual — Use of C-mount Adapter with and without IR-cut Filter
Page 73 · cliquer pour agrandir
Page 73
Micron Technology USB Camera — Use of C-mount Adapter with and without IR-cut Filter diagram (page 73)
Fig. 59 · Use of C-mount Adapter with and without IR-cut Filte…

Use of C-mount Adapter with and without IR-cut Filter

The C-mount adapter is an adapter that converts the SMX-M8xx camera from SC- mount (the initial form factor of the SMX-M8xx cameras) to C-mount.

The C-mount adapter with IR-cut filter is a C-mount adapter that additionally contains a built-in IR-cut filter (see chapter “IR-cut filter Characteristics” ).

Both color and monochrome camera models can be used either with C-mount adapter or C-mount adapter with IR-cut filter.

IR-cut filter is a color filter that blocks infrared light.

The IR-cut filter characteristics are as follows:

  • Diameter = 20mm
  • Thickness = 2 mm

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Overview · IR-cut filter Characteristics

Page 74 of the Micron Technology USB Camera user manual — When to Use the C-mount Adapter with IR-cut Filter
Page 74 · cliquer pour agrandir
Page 74
Micron Technology USB Camera — When to Use the C-mount Adapter with IR-cut Filter diagram (page 74)
Fig. 60 · When to Use the C-mount Adapter with IR-cut Filter
Micron Technology USB Camera — When to Use the C-mount Adapter with IR-cut Filter diagram (page 74)
Fig. 61 · When to Use the C-mount Adapter with IR-cut Filter

Chart of the IR-cut filter transmission characteristics

When to Use the C-mount Adapter with IR-cut Filter

C-mount adapter with IR-cut filter use with the color cameras. Since the SMX-M8xx color cameras are sensitive to IR-light, use the C-mount adapter with IR-cut filter for the color camera models to make colors of the image more realistic.

Many light sources, including the sun, emit infrared light, so the color camera in daylight will see a significant amount of infrared light without the IR-cut filter. As a result, strange and non-realistic colors appear.

Another reason for using the IR-cut filter is the limited color correction for many lenses. A lot of lenses have different depth of focus for the visible and infrared spectrum. The IR-cut filter cuts away a significant amount of the overall collected light and thereby affects the sensitivity in a negative way. In general, color cameras are one factor less sensitive compared to monochrome (depending on the sensor). This is primarily due to the IR-cut filter.

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 75 of the Micron Technology USB Camera user manual — C-mount adapter with IR-cut filter use with monochrome cameras
Page 75 · cliquer pour agrandir
Page 75

C-mount adapter with IR-cut filter use with monochrome cameras. The SMX-M8xx monochrome cameras (the SMX-M81M cameras) are more sensitive to infrared light than color models. Using the cameras in environment rich for infrared light may result in highlighted images. In order to avoid highlighted images, use the C-mount adapter with IR-cut filter for monochrome cameras.

Using the SMX-M8xx Camera as CS-mount

Using the SMX-M8xx camera as CS-mount means using it without both C-mount adapter and C-mount adapter with IR-cut filter:

Micron Technology USB Camera — C-mount adapter with IR-cut filter use with monochrome cameras diagram (page 75)
Fig. 62 · C-mount adapter with IR-cut filter use with monochro…
CS-mountwithout C-mount adapter

Using the SMX-M8xx Camera as C-mount

Using the SMX-M8xx camera as C-mount means using it with the C-mount adapter or with the C-mount adapter with IR-cut filter:

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 76 of the Micron Technology USB Camera user manual — Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mount
Page 76 · cliquer pour agrandir
Page 76
Micron Technology USB Camera — Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mount diagram (page 76)
Fig. 63 · Converting the SMX-M8xx Camera from CS-mount to C-mo…
C-mountwith C-mount adapter or C-mount adapter

CS-mount: without both C-mount adapter and C-mount adapter with IR-cut fil- ter C-mount adapter with IR-cut filter or without IR-cut filter

Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mount

Usually the SMX-M8xx camera goes with the C-mount adapter or C-mount adapter with IR-cut filter already screwed in.

To use the SMX-M8xx camera as CS-mount screw the C-mount adapter/C-mount adapter with IR-cut filter out.

To use the SMX-M8xx camera as C-mount screw the C-mount adapter/C-mount adapter with IR-cut filter in.

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

with IR-cut filter

Page 77 of the Micron Technology USB Camera user manual — Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mount
Page 77 · cliquer pour agrandir
Page 77

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 78 of the Micron Technology USB Camera user manual — Use of Tripod Adapter with the SMX-M8xx Cameras
Page 78 · cliquer pour agrandir
Page 78

Use of Tripod Adapter with the SMX-M8xx Cameras

The SMX-M8xx camera may go with the Tripod adapter already on:

Micron Technology USB Camera — Use of Tripod Adapter with the SMX-M8xx Cameras diagram (page 78)
Fig. 64 · Use of Tripod Adapter with the SMX-M8xx Cameras

To remove the Tripod adapter from the camera:

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 79 of the Micron Technology USB Camera user manual — Use of Tripod Adapter with the SMX-M8xx Cameras
Page 79 · cliquer pour agrandir
Page 79
1. Loosen the screw of the Tripod adapter 2. Remove the Tripod adapter from the camera:
Micron Technology USB Camera — Use of Tripod Adapter with the SMX-M8xx Cameras diagram (page 79)
Fig. 65 · Use of Tripod Adapter with the SMX-M8xx Cameras
Micron Technology USB Camera — Use of Tripod Adapter with the SMX-M8xx Cameras diagram (page 79)
Fig. 66 · Use of Tripod Adapter with the SMX-M8xx Cameras

To put the Tripod adapter on the camera, do the following: 1. Loosen the screw of the Tripod adapter 2. Put the Tripod adapter on the camera and locate it as shown in the image below:

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 80 of the Micron Technology USB Camera user manual — Use of Tripod Adapter with the SMX-M8xx Cameras
Page 80 · cliquer pour agrandir
Page 80
Micron Technology USB Camera — Use of Tripod Adapter with the SMX-M8xx Cameras diagram (page 80)
Fig. 67 · Use of Tripod Adapter with the SMX-M8xx Cameras
Micron Technology USB Camera — Use of Tripod Adapter with the SMX-M8xx Cameras diagram (page 80)
Fig. 68 · Use of Tripod Adapter with the SMX-M8xx Cameras

Basic Guidelines on Using the SMX-M8xx Series USB2.0 Cameras

Page 81 of the Micron Technology USB Camera user manual — Camera was not Detected or Recognized
Page 81 · cliquer pour agrandir
Page 81

Appendix 5

C AMERA I NSTALLATION T ROUBLESHOOTER

Before following instructions of this chapter make sure that you follow all instructions and recommendations that are described in the See “Installation” on page 11 chapter of this Document.

If you face problems with installation and detection of the camera, use this Troubleshooter.

If you face problems that are not described below, contact Sumix Technical Department.

Camera was not Detected or Recognized

If after connecting the camera the system does not detect it: there is no icon

on your Taskbar; or the camera was not recognized by the system:

Micron Technology USB Camera — Camera was not Detected or Recognized diagram (page 81)
Fig. 69 · Camera was not Detected or Recognized

try to:

  • Check if the device was installed successfully: open the following system folder: WINDOWS> system32>drivers and check if the SMXM8X.sys file is present (normally it is located on the C hard disk). If not, run the Driver installation again. Be sure that no camera is connected during installation.

If the same problem still occurs, save manually the SMXM8X.sys file to the WINDOWS>system32>drivers folder (the SMXM8X.sys file is located in the \Sumix\SMX-M8x USB2.0 Camera\Drivers folder)

If you failed on previous step, try one of the following:

  • Reconnect the camera
Camera Installation TroubleshooterCamera was not Detected or Recognized
Page 82 of the Micron Technology USB Camera user manual — Camera Installation Troubleshooter
Page 82 · cliquer pour agrandir
Page 82
  • Use other USB2.0 port(s) of your computer - the problem might be due to the faulty USB2.0 port
  • Use another USB2.0 cable - the problem might be due to the faulty USB2.0 cable
  • Connect other (if any) SMX-M8xx camera to the same USB2.0 port(s) (if you have more than one) - the problem might be due to the faulty camera
  • Disconnect the camera and restart the computer

If none of the previous steps succeeded, and the device is not recognized yet, try to do the following: 1. Connect the problematical camera to your computer 2. Open the Device Manager window (right-click My Computer desktop icon, select Properties, then select the Hardware tab, and click Device Manager) 3. In Device Manager select one of the following:

  • Imaging devices> SMX M8X Series USB2.0 Camera with the Warning status, if it available:
Micron Technology USB Camera — Camera Installation Troubleshooter diagram (page 82)
Fig. 70 · Camera Installation Troubleshooter
  • Universal Serial Bus controllers> Unknown device (in the case if no SMX-M8X Series USB2.0 Camera with the Warning status available in the Imaging devices ):
Camera Installation TroubleshooterCamera was not Detected or Recognized
Page 83 of the Micron Technology USB Camera user manual — Camera Installation Troubleshooter
Page 83 · cliquer pour agrandir
Page 83
Micron Technology USB Camera — Camera Installation Troubleshooter diagram (page 83)
Fig. 71 · Camera Installation Troubleshooter
4. Right-click and select ' Update Driver… ':
Micron Technology USB Camera — Camera Installation Troubleshooter diagram (page 83)
Fig. 72 · Camera Installation Troubleshooter
5. Select ‘No, not this time’ in the Welcome to the Hardware Update Wizard window and click Next :
Camera Installation TroubleshooterCamera was not Detected or Recognized
Page 84 of the Micron Technology USB Camera user manual — Camera Installation Troubleshooter
Page 84 · cliquer pour agrandir
Page 84
Micron Technology USB Camera — Camera Installation Troubleshooter diagram (page 84)
Fig. 73 · Camera Installation Troubleshooter

Run the Hardware Update Wizard the same way as the Found New Hardware Wizard choosing the 'Install the software automatically (Recommended)':

Micron Technology USB Camera — Camera Installation Troubleshooter diagram (page 84)
Fig. 74 · Camera Installation Troubleshooter

See the ‘Manual Hardware Installation’ chapter of the SMX-M8xx USB2.0 Camera User Guide and follow its recommendations on this step (see chapter “Manual Hardware Installation” ).

If some problems occur during the manual hardware installation, read the next chapter of this Troubleshooter (see chapter “Cannot Install the Hardware” ).

If the system still fails to detect the camera after all these actions, described above, contact Sumix Technical Department.

Camera Installation TroubleshooterCamera was not Detected or Recognized
Page 85 of the Micron Technology USB Camera user manual — Cannot Install the Hardware
Page 85 · cliquer pour agrandir
Page 85

Cannot Install the Hardware

If the Found New Hardware Wizard\Hardware Update Wizard failed to install the hardware (the Wizard that starts after the first connection of the camera or the Wizard that starts for updating the hardware; failure appears after you browsed to the needed files for the installing):

Micron Technology USB Camera — Cannot Install the Hardware diagram (page 85)
Fig. 75 · Cannot Install the Hardware

Try to do the following: 1. Click Back in the Found New Hardware Wizard and select 'Install from a list or specific location (Advanced)' 2. Click the Next button:

Micron Technology USB Camera — Cannot Install the Hardware diagram (page 85)
Fig. 76 · Cannot Install the Hardware
3. Select ' Search for the best driver in these locations. ' 4. Check the ' Include this location in the search ' checkbox
Camera Installation TroubleshooterCannot Install the Hardware
Page 86 of the Micron Technology USB Camera user manual — Cannot Install the Hardware
Page 86 · cliquer pour agrandir
Page 86
5. Browse to the Drivers folder - from the SMX-M8xx Camera CD or from the Sumix\SMX-M8x USB2.0 Camera folder (located on the hard disk where you installed the SMX-M8x Camera Software , normally it is C:\Program Files\Sumix\SMX-M8x USB2.0 Camera ) 6. Click the Next button:
Micron Technology USB Camera — Cannot Install the Hardware diagram (page 86)
Fig. 77 · Cannot Install the Hardware
7. Wait till the Wizard installs all needed files

Click Finish if installation passed successfully

Camera Installation TroubleshooterCannot Install the Hardware
Page 87 of the Micron Technology USB Camera user manual — Table of contents
Page 87 · cliquer pour agrandir
Page 87

Table of contents

SMX-M8xx Series USB2.0 Camera User Guidep.1Contentsp.5Introductionp.9Camera Specificationsp.10SMX-M8xx Camera Kitp.13Installationp.15Automatic Camera Installationp.15Manual Hardware Installationp.19Removing the SMX-M8xx Camerap.22Removing the Softwarep.22Removing the Hardwarep.23Updating the Hardwarep.25Getting Startedp.27Sensor Controlp.31Exposurep.31Gainp.31Frequencyp.31Decimationp.32Viewport Settingsp.32Image Correctionp.33Color Balancep.33Color Correctionp.35Snapshotsp.37Snapshots Basicsp.37Switching Between Camerasp.39Camera Device Settingsp.41Camera Infop.41Color Modep.41Flip Imagep.42Average Framesp.42Max Exposurep.43Direct Access To Driver Frame Memoryp.43Enable Image Correctionp.43Display Video on Program Startupp.43Auto White Balance Hardwarep.43Auto White Balance Softwarep.44Frame Rate Controlp.44Output Bits per Pixel Controlp.45Median Filterp.45Limit Gainp.45Profilesp.47Capturingp.49Guidelines for Using TWAIN Driverp.53Overviewp.53Installationp.53How It Worksp.53Locationp.53Getting Image Using Scanner and Camera Wizardp.55Getting Image Using Scanp.60Getting Image from Camera Using Microsoft Paintp.62Menu Overviewp.65Filep.65Editp.65Devicep.65Helpp.66Keyboard Shortcutsp.67Main Keyboard Shortcuts Operationsp.67Toolbar Overviewp.69Main Toolbar Operationsp.69Basic Guidelines on Using the SMX-M8xx Series USB2.0 Camerasp.71Introductionp.71Camera Kitp.71Use of C-mount Adapter with and without IR-cut Filterp.73Overviewp.73IR-cut filter Characteristicsp.73When to Use the C-mount Adapter with IR-cut Filterp.74C-mount adapter with IR-cut filter use with the color camerasp.74C-mount adapter with IR-cut filter use with monochrome camerasp.75Using the SMX-M8xx Camera as CS-mountp.75Using the SMX-M8xx Camera as C-mountp.75Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mountp.76Use of Tripod Adapter with the SMX-M8xx Camerasp.78Camera Installation Troubleshooterp.81Camera was not Detected or Recognizedp.81Cannot Install the Hardwarep.85Figuresp.87Tablesp.89
Page 88 of the Micron Technology USB Camera user manual — Table of contents
Page 88 · cliquer pour agrandir
Page 88

Table of contents

SMX-M8xx Series USB2.0 Camera User Guidep.1Contentsp.5Introductionp.9Camera Specificationsp.10SMX-M8xx Camera Kitp.13Installationp.15Automatic Camera Installationp.15Manual Hardware Installationp.19Removing the SMX-M8xx Camerap.22Removing the Softwarep.22Removing the Hardwarep.23Updating the Hardwarep.25Getting Startedp.27Sensor Controlp.31Exposurep.31Gainp.31Frequencyp.31Decimationp.32Viewport Settingsp.32Image Correctionp.33Color Balancep.33Color Correctionp.35Snapshotsp.37Snapshots Basicsp.37Switching Between Camerasp.39Camera Device Settingsp.41Camera Infop.41Color Modep.41Flip Imagep.42Average Framesp.42Max Exposurep.43Direct Access To Driver Frame Memoryp.43Enable Image Correctionp.43Display Video on Program Startupp.43Auto White Balance Hardwarep.43Auto White Balance Softwarep.44Frame Rate Controlp.44Output Bits per Pixel Controlp.45Median Filterp.45Limit Gainp.45Profilesp.47Capturingp.49Guidelines for Using TWAIN Driverp.53Overviewp.53Installationp.53How It Worksp.53Locationp.53Getting Image Using Scanner and Camera Wizardp.55Getting Image Using Scanp.60Getting Image from Camera Using Microsoft Paintp.62Menu Overviewp.65Filep.65Editp.65Devicep.65Helpp.66Keyboard Shortcutsp.67Main Keyboard Shortcuts Operationsp.67Toolbar Overviewp.69Main Toolbar Operationsp.69Basic Guidelines on Using the SMX-M8xx Series USB2.0 Camerasp.71Introductionp.71Camera Kitp.71Use of C-mount Adapter with and without IR-cut Filterp.73Overviewp.73IR-cut filter Characteristicsp.73When to Use the C-mount Adapter with IR-cut Filterp.74C-mount adapter with IR-cut filter use with the color camerasp.74C-mount adapter with IR-cut filter use with monochrome camerasp.75Using the SMX-M8xx Camera as CS-mountp.75Using the SMX-M8xx Camera as C-mountp.75Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mountp.76Use of Tripod Adapter with the SMX-M8xx Camerasp.78Camera Installation Troubleshooterp.81Camera was not Detected or Recognizedp.81Cannot Install the Hardwarep.85Figuresp.87Tablesp.89
Page 89 of the Micron Technology USB Camera user manual — Table of contents
Page 89 · cliquer pour agrandir
Page 89

Table of contents

SMX-M8xx Series USB2.0 Camera User Guidep.1Contentsp.5Introductionp.9Camera Specificationsp.10SMX-M8xx Camera Kitp.13Installationp.15Automatic Camera Installationp.15Manual Hardware Installationp.19Removing the SMX-M8xx Camerap.22Removing the Softwarep.22Removing the Hardwarep.23Updating the Hardwarep.25Getting Startedp.27Sensor Controlp.31Exposurep.31Gainp.31Frequencyp.31Decimationp.32Viewport Settingsp.32Image Correctionp.33Color Balancep.33Color Correctionp.35Snapshotsp.37Snapshots Basicsp.37Switching Between Camerasp.39Camera Device Settingsp.41Camera Infop.41Color Modep.41Flip Imagep.42Average Framesp.42Max Exposurep.43Direct Access To Driver Frame Memoryp.43Enable Image Correctionp.43Display Video on Program Startupp.43Auto White Balance Hardwarep.43Auto White Balance Softwarep.44Frame Rate Controlp.44Output Bits per Pixel Controlp.45Median Filterp.45Limit Gainp.45Profilesp.47Capturingp.49Guidelines for Using TWAIN Driverp.53Overviewp.53Installationp.53How It Worksp.53Locationp.53Getting Image Using Scanner and Camera Wizardp.55Getting Image Using Scanp.60Getting Image from Camera Using Microsoft Paintp.62Menu Overviewp.65Filep.65Editp.65Devicep.65Helpp.66Keyboard Shortcutsp.67Main Keyboard Shortcuts Operationsp.67Toolbar Overviewp.69Main Toolbar Operationsp.69Basic Guidelines on Using the SMX-M8xx Series USB2.0 Camerasp.71Introductionp.71Camera Kitp.71Use of C-mount Adapter with and without IR-cut Filterp.73Overviewp.73IR-cut filter Characteristicsp.73When to Use the C-mount Adapter with IR-cut Filterp.74C-mount adapter with IR-cut filter use with the color camerasp.74C-mount adapter with IR-cut filter use with monochrome camerasp.75Using the SMX-M8xx Camera as CS-mountp.75Using the SMX-M8xx Camera as C-mountp.75Converting the SMX-M8xx Camera from CS-mount to C-mount, from C-mount to CS-mountp.76Use of Tripod Adapter with the SMX-M8xx Camerasp.78Camera Installation Troubleshooterp.81Camera was not Detected or Recognizedp.81Cannot Install the Hardwarep.85Figuresp.87Tablesp.89
Page 90 of the Micron Technology USB Camera user manual — Tables
Page 90 · cliquer pour agrandir
Page 90

Tables

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Micron Technology USB Camera

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Micron Technology USB Camera

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Micron Technology USB Camera manuel PDF

90 pages·4.2 MB·Appareil photo numérique·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…