Manuel d'utilisation / d'entretien du produit PS40 du fabricant Lennox Hearth
Aller à la page of 28
INST ALLA TION AND OPERA TION MANUAL Retain These Instructions For Future Reference Pe ll et S to ve s Mo de l W in sl ow ™ (P S4 0) Fr ee -S ta nd in g Pe ll et S to ve P/N 775 ,228 M, R ev . A, 05/2 007 A Fr ench man ual is a vail able upo n re ques t.
2 F ea tures a nd s peciFica tions .......................................................................................... 3 L isting i nForma tion ................................................................................................... 3 a ppearance c hoices .
3 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Features and Specifications i nst aLLation o ptions • Residential • V ented vertical and horizontal (see venting instruc - tions) • Manufactured home and mobile home • Thermostat or manual operation • Bedrooms h ea ting • Max.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Clearances to Combustibles Corner Installations Left Wall Horizontal V enting 8 Side V iew Front V iew 8 Side V iew Front V iew 26-1/4” (667mm.
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Corner Installations Continued Vertical V enting Parallel Installations Vertical V enting Alcove Installations Minimum alcove height is 41” (1041mm), minimum width is 42-1/4” (1073mm), and maximum depth is 48” (1219mm).
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. h earth p rotection The floor protector must be a non-combustible material extending beneath the stove and to the front and sides as shown below . Minimum Size Hearth Protection v ent t ermina tion r equirements 1.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. V ent Installation v ent t ermina tion L ocations A = Clearance above grade, veranda, por ch, deck, or bal- cony (min. 12”/30cm) B = Cl earan ce to wi ndow or door that may be opened (min . 12”/30cm above - 48”/1.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. v enting Pellet pipe type PL or L must be used to vent the Winslow™ PS40 stove. Single wall pipe cannot be used with this pellet stove.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. m asonry c himney When venting into a masonry chimney , the pellet pipe can terminate just inside the chimney .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. m obiLe h ome i nst aLLations Th e fol lo wi ng are req uir ed fo r ins ta ll at io n of the Wi ns lo w™ PS 40 s tov e in m ob il e h om es .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Door T rim Installation Instructions Parts List (A): Qty (2) T rim Pieces (Gold, Nickel, Brushed Nickel or Black Nickel ) (6) #10 nuts (6) #10 .
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4. Place one washer on each stud. Using a 3/8” nut driver , snug up the nuts on each piece of trim.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Door Grill Installation Instructions Parts Needed: Qty (4) Button Head Screws (already in place in stove) T ools Required: Qty (1) 1/8” allen wrench T o install the Grill: 1. Remove the four button head screws from body of the stove with a 1/8” allen wrench.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: The brick panel comes pre-painted with Metallic Black paint. The brick panel may be painted with any color of Stove Bright® high-temp paint (paint may dis - color with use). 1. Remove the front door of the pellet stove.
.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Log Set installation Instructions Kit Contents (A): Part #H5142 Qty (1) left log (B) (1) right log (C) (1) front log (D) (2) log support bracke.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operation c ontroL b oard The control board regulates all functions of the stove. The following is a list of the board’ s components: • Feeding light - lights up when the auger is feeding pellets into the burn pot.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. s hut d own Normal - T o turn the stove off, turn the heat selector knob to off. The fans will continue to operate until the control board completes the shut down cycle. Power Outage - If the stove loses electrical power for less than 10 seconds it will continue to operate.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cleaning and Maintenance Unplug and let the Winslow™ PS40 stove cool before per - formi ng any mainten ance or clean ing.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. c Leaning the h ea t e xchanger Caution: Do not operate the heat exchange scraper when the stove is hot. Located at the center of the grill on the top front of the stove is a bent rod that is attached to a scraper on the heat exchange tubes.
.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. F ront d oor r emov aL Caution: Do not open the front door when the stove is hot. T o remove the door , swing the left and right side doors A open. Pull the front door handle B to the front and swing the front door open.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. b ack r emov aL and L ower c over p La te T o remove the back: 1. Remove the left and right side panels (see the previous page).
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. d raFt a djuster The Winslow™ PS40 stove has a draft adjuster located at the left side of the stove direc tly in front of the combust ion blowe r .
25 d iagnostic c odes If the stove operates abnormally , the ready light on the control board will signal the nature of the abnormal operation. The following is a list of possible signals or codes: Re.
26 e LectricaL g enera tor o peration Y our Winslow™ PS40 stove can be powered with a gas driv en elec trica l gerera tor . Howeve r , the genera tor’ s elec trica l regulator may not be compatible with the stove’ s electron - ics. The higher the quality of the gererator , the greater the chance that it is compatible with the stove.
27 Y our Stove’ s Model Number __________________________________________ Y our Stove’ s Serial Number ___________________________________________ The Date On Which Y our Stove Was Installed _____.
Printed in U.S.A. © Lennox Hearth Products 2007 P/N 775,228M REV . A 05/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lennox Hearth PS40 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lennox Hearth PS40 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lennox Hearth PS40, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lennox Hearth PS40 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lennox Hearth PS40, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lennox Hearth PS40.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lennox Hearth PS40. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lennox Hearth PS40 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.