Autotrol ® Brand 255 V alve / 400 Series Controls W ater Conditioning Control System Home Owner Inst allation, Operation, and Maintenance Manual For sales or service questions please cont act your local dealer: Y our Local Dealer Is: 1018075 Rev I.
2 T able of Content s Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 V alve Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Introduction . . . .
3 Safety Information This water conditio ner ’s control valve conf orms to NSF/ANSI 44 for materials and structural integrity only . Generic systems were tested and certified by WQA as verified by the performan ce data sheet. • Please review this entire Installation and Operation manual before installing unit.
4 V alve Illustration Autotrol 255 V alve Control Module Figure 2 B Y P A S S B Y P A S S Optional i-lid Cov er T ank Adapter Module Figure 1 Air Check Brine Line Fitting Connectio n Probe Connection .
5 Introduction The 255 series control incor porates five cycles during operation, Figure 3 and is responsible for directing the flo w of water during all phases of regeneration. The water conditioner consist s of a control valv e, mineral tank, re sin and a salt storage tank.
6 Figure 3 Inst allation All plumbing must conform to local codes. Inspect unit carefully for carrier sh ortage or shipping damage. Location Selection 1.
7 rated tempera ture and pressure safety r elief valve. Also, be cert ain that local codes are not violated. 5. Do not locate unit where it or it’ s co nnections (including the d rain and overflow lines) will ever be subjected to room temperat ures under 34 o F (1 o C) or ov er 120 o F (49 o C).
8 Drain Line Connection 1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the drain. For such inst allations, use an appr opriate adapter fitting (not supplied), to connect 1/2-inch (1.3-cm) plastic tubing to the drain line connection of the control valve.
9 Overflow Line Connection In the absence of a safety overflow and in the event of a malfunction, the BRINE T AN K OVERFLOW will direct “o verflow” to the drain instead of spilling on the floor where it cou ld cause con siderable dama ge. This fitting should be on the side of the cabinet or brine t ank.
10 Increasing the Length of the T ransformer Cord If it is necess ary to extend the length of the transf ormer cord, a n optional 15 -foot (4.6-m) ex tension is av ailable (see Fig ure 9).
11 Sodium or Calcium Hypochlorite Application These materials ar e satisfactory for use with polystyrene re sins, synthetic gel zeolite, greensand an d bentonites. 5.25% Sodium Hypochlorite These solutions are availab le under trade names such as Clorox*.
12 COUNTERCLOCKWISE only until arrow or knob point s to desired position. Rotation is made much easier if you grasp the camshaft with yo ur free hand and turn it at the same time. Then permit kno b to spring back out. 2. Insert screwdriver into slot in indicator knob (Figu re 1 1).
13 Control Valve Figure 10 - Control Valve 5. Put into operation. a. Open water supply valve slowly to full open posi tion. b. Carefully advance indicator knob COUNTERCLOCKWISE to center of F AST RINSE/REFILL position and hold there unt il air check (Figure 10) fills with water and water star ts to flow through brine line into b rine tank.
14 400 Series Control Settings 440i Control Figure 11 Programming 1. Set days of regeneration on skipper wheel (Figure 1 1). • Pull all skipper pi ns outward (away from control). • Rotate skipper wheel until day arrow points to curr ent day or number 1.
15 460i Control Figure 12 Programming Plug the wall-moun t transformer into a fu nc tioning electrical outlet that is not controlled by a switch. Plug the transfo rmer into the transformer plug recept acle on the control. Open the access door by pushing the raised tab on the door toward the lef t while pulling the tab out (Figure 12).
16 Hardness Setting Move the jumper to the set of pins next to the word HARDNESS (Figure 14). Press the bla ck TIME SET button until t he hardness of the incoming wate r supply is displayed.
17 4. Depress the black TIME SET button. The numbers will roll fr om “0” to “15.” Release the switch at the de sired number of days for the calendar override. For example, releasing the switch at “10” would pr ogram a 10-day calendar override.
18 *This setting requires the use of “XS” (e xtra salt) cam and double s the amount of the setting. The amount of salt placed in the brine t ank has nothing to do with the amount of salt used during the regeneration cycle. Wa ter will di ssolve and absorb salt only until it becomes satura ted.
19 Preventive Maintenance Inspect and clean brine t ank and screen f ilter on end of brine pickup tube once a year or when sediment ap pears in the bottom of the brine tank. Clean injector scr een an d injector once a year : 1. Unplug the wall-mount transformer .
20 Replacement Part s for Autotrol Brand 255 Control V alve Body 19 21 18 6 5 4 3 2 1 7 8 9 10 11 12 7 16 15 13 23 22 22 23 21 21 22 17 22 i n l e t o u t l e t d r a i n 20 14 T ank Adapter Module 1018075 Rev I.
21 255 V alve & T ank Adapter Module Code Part No. Descripti on Qty . 1 1000232 V alve Assembly , w/o Flow Contro ls 1 2 Camshaft: 1 1031950 St andard, One-Piece 1033024 St andard, Segmented 10330.
22 * Not Shown **Flow control does not use Flow Control Ball (1030502). Kits: 21 1001404 O-Ring Gro up: T ank Adapter , 10101 17 (1), 1010407 (1), 101041 0 (4) 22 1040459 O-Ring Gro up: Piping Boss 1010431 (1), 101041 1 (2 ) 23 1041010 13/16 R ubber Insert (Optional) V alve Discs: * 1000250 S tandard 1018075 Rev I.
23 Replacement Part s T O S E T T IM E O F D A Y P U LL K N O B A N D R O T A T E MA NUAL REG ENERA ION : P R E S S K N O B A N D T U R N CO U N T E R - CL O CKWIS E T O"S T A R T" Ð R E L .
24 255 Series Acce ssories Code Part No. Description Qty . 1 440i Assembly 1 2 460i Assembly 1 3 T ransformer 1 1000810 Japanese 100081 1 North American 1000812 Austral ian 1000813 British 1000814 Europea n * 1030234 T ransformer Extension Cord 15 foot (4.
25 * 1001606 3/4-inch Copper Tube Adapter Kit 1 * 1001670 1-inch Copper Tube Adapter Kit 1 * 1041210 1-1/4-inch Copper Tube Adapter Kit 1 * 1040547 90 degree Elbow Adapter Kit 1 * 1001608 22-mm Copper.
26 T roubleshooting The technology upon which the Series 25 5 control is based is well est ablished and proven in service over many year s. Howe ver , shou ld a problem or quest ion arise regarding the operation of the system, the control can be very easily serviced.
27 4. Control will not draw brine. a. Low water pressure. b. Restricted drain li ne. c. Injec tor plugged ! d. Injector defecti ve ! e. V alve disc 2 and/or 3 not closed. f. Air check valve prematurely closed. a. Make correct setting according to instructions.
28 255/440i T roubleshooting Problem Possible Cause Solution 1. Control will not regenerate automatically . a. T ransformer or motor not connected. b. Defective timer mot or . c. Skipper pi ns not down on timer skipper wheel. d. Binding in g ear train of timer .
29 255/460i T roubleshooting 7. Control backwashes or purges at excessively low or high rate. a. Incorre ct drain cont roller used. b. Foreign matter af fecting controller operati on. a. Replace with correct size controller . (Contact dealer .) b. Remove drain controll er and clean ball a nd seat.
30 6. Control regenerates at wrong time of d ay . a. Power outages. b. Clock set in correctly . a. Reset cl ock to correct time of day . b. Reset cl ock to correct time of day . 7. T imer stalled in regenerati on cycle. a. Motor dead. b. Motor runs backward.
31 10. Control will not regenerate automatically but will regene rate when button is pressed. a. If water flow display i s not operative, refer to Item 5. b. Defective ci rcuit board. c. Incorrect h ardness and capacity settings . a. Same as Item 5. b.
© Copyright 2004 GE Water Technologies Printed in t he USA P/N 10180 75 Rev. I For service or parts, please c ontact your local professional water treatment dealer . V alve Specifications Working Pressure . . . . . . . . . . . . . . . . . . . . . . .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GE 255 Valve / 400 Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GE 255 Valve / 400 Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GE 255 Valve / 400 Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GE 255 Valve / 400 Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GE 255 Valve / 400 Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GE 255 Valve / 400 Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GE 255 Valve / 400 Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GE 255 Valve / 400 Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.