Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.GarrettCom .
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) i www Garre t t C om com .. Magnum ™ FT14 and FT14H 10Mb/s Media Converters Installation and User Guide Part #: 84-00134 Rev.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) ii www Garre t t C om com .. Federal Communications C ommission Radio Frequency I nterference Statement This equipment generat.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) iii www Garre t t C om com .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) iv ww Garr w e t t C om com .. TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications .
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) v www Garre t t C om com .. 3.6 Connecting Ethernet Medi a ............................................................... 34 3.6.1 Connecting Twisted Pair (RJ-45 ports ) ......
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) vi www Garre t t C om com .. Revisions Rev A 09/04: Minor updates on UL Requirem ents, power supplies Rev A 06/04: Minor updates on Agency approvals and power supplies Rev A 05/03: Initial release of this user manual for FT14 and FT14H GarrettCom, Inc.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 1 www Garre t t C om com .. 1.0 SPECIFICATIONS 1.1 Technical Specifications Model FT14, FT14H multi-mode and single-mode Performance: Data Rate: 10 Mbps (IEEE 802.3), half duplex mode Network Standards: Ethernet: Ethernet V1.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 2 www Garre t t C om com .. Maximum Standard Ethernet Segment Lengths: 10BASE-T (twisted pair): 100 m (328 ft) 10BASE-FL Fiber optic : 2.0 km (6,562 ft) 10BASE-FL Single-mode Fi ber optic: 10.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 3 www Garre t t C om com .. Ambient Relative Hum idity: 5% to 95% (non-condensing) UL 2043 tested for above-the –ceiling (plenum) installation Conformal coating (hum id ity protection) option, request quote.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 4 www Garre t t C om c om .. 100-240V AC at 50-60Hz, for high temp. with built-in IEC320 connector for “-Hi” DC to unit : “Hi” international model 9V DC, 2.5mm jack, center +ve, 6ft.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 5 www Garre t t C om com .. RJ-45 Port: Modular 8-Pin female , with “cross-over” up-link switch Fiber Port: Fiber optic (standard ST type) Packaging: Enclosure: Rugged sheet metal (Steel).
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 6 www Garre t t C om com .. Metal Mounting clips for panel mou nting : included DIN-Rail mounting option : Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option : MC14-TRAY, see http ://www.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 7 www Garre t t C om com .. 1.2 Summary of models and de sc r i ptions: FT14-Hd = TP to 10Mb m m Fiber ST , external 115 60Hz .
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 8 www Garre t t C om com .. 2.0 INTRODUCTION This section describes the FT14 and FT14H models, including appearance, features and typical applications.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 9 www Garre t t C om com .. Remove the Magnum Media Converter from the sh ipping container. Be sure to keep the shipping container should you need to ship the unit at a later date.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 10 www Garre t t C om c om .. The FT14 regular-package units are for office and wiring closet environments and use an external AC power supply. A meta l case with convection cooling is featured.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 11 www Garre t t C om com .. Operation may be in 0° to 50°C ambient temp erature. The units can be mounted securely on a closet wall or metal cabinet, or by usi ng the metal panel mounting clips included.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 12 www Garre t t C om c om .. All units are compatible with Ethernet V 1.0 / 2.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 13 www Garre t t C om com .. The up-link (or crossover) switch on the RJ-45 por t simplifies cable installation. All fiber models operate in transparent full- or ha lf-duplex mode, supporting matched sets of either mode type, i.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 14 www Garre t t C om com .. extended temperature power supply AC/DC (External/Internal) to qualify for un- controlled and Industrial application. Each c onverter features two full sets of LEDs that convey essential diagnostic and st atus information at any angle.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 15 www Garre t t C om com .. 2.3 Features and Benefits Reduces Networ k Costs Magnum Media Converters offer the ideal solu.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 16 www Garre t t C om com .. Two sets of LEDs for viewing status from any angle.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 17 www Garre t t C om com .. Qualifie d to use for temperature un-c ontr olled “outdoor” appli c ati o n The Magnum FT.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 18 www Garre t t C om com .. 2.4 Applications for FT14’s and harde ne d FT14H’s The primary function of a 10Mb Ethernet Me.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 19 www Garre t t C om c om .. In this application, in a Industrial envir onment where extended temp .
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 20 www Garre t t C om com .. 2.5 Full / Half-duplex capability For 10Mb FT14-series Media convert ers, the twisted-pair to fiber combination is capable of full-duplex (i.e., sim ultaneously transmitting and receiving on the same cable segm ent) opera tion.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 21 www Garre t t C om c om .. networks, the LINK signal on a managed switch (o r hub) port is used as an indicator that the attached cable segment is installed and operable.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 22 www Garre t t C om c om .. the cable attached to a managed switch port. The Link-Pass-through in the FT14H models provides the LINK “see-through” feature desired for managed networks.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 23 www Garre t t C om c om .. 3.0 INSTALLATION This section describes the installa tion of the Magnum FT14-series Media Converters, including location, segment distance calculation and media connection.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 24 www Garre t t C om com .. Velcro strip may be used for mounting the unit on a vertical surface such as a w all or cabinet, or for securing the unit on a table-top or shelf.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 25 www Garre t t C om c om .. 3.2 MC14-TRAY for Rack Mounting of FT14 and FT14H Media Converter s For 19” rack-mounting of Magnum FT14-series Media Converters, a rack-mount tray is available, MC14-TRAY.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 26 www Garre t t C om com .. specific to the “14”-series, a nd do not permit other models).
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 27 www Garre t t C om c om .. MC14-TR+PS9 and 16 units of Fiber medi a converters for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of ei ght units per power s upply. These models are equipped with auto- ranging AC input to the power supplies for use worldwide.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 28 www Garre t t C om com .. The side-view picture shown here (above) is an example of an installation of the model MC14-TR+PS.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 29 www Garre t t C om c om .. The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model # DIN-RAIL- MC2. It comes with four screws to attach the bracket to the MC unit.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 30 www Garre t t C om com .. order to maintain optimum network perform ance. (See also Technical Specs, Maximu m Standard Ethernet Segment Distan ces, Section 1.1 of this manual.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 31 www Garre t t C om c om .. Twisted Pair ( 10BASE-T) Y = 55m Fiber optic - ST Connecto r (10BASE-FL and FOIRL) X = 780m LINK LINK RX/ACT PWR FIBER COPPER P 9VDC .
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 32 www Garre t t C om com .. Media Distance Formula for Magnum Media Converters: X% + Y% < 100% Where X = The segment distance on one side of the Magnum Media Converter divided by the Standard Maximum Media Distance for that media type, x 100%.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 33 www Garre t t C om com .. allowable distance for UTP 10BASE-T media (100 m) [55/100 x 100% = 55%].
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 34 www Garre t t C om com .. 3.6 Connecting Ethern et Media Connecting Ethernet media to the Ma gnum FT14 Series Media Converter is very simple and straightforward. Using pr oper media segment, simp ly attach the cable end to the appropriate connector.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 35 www Garre t t C om com .. 2. Connect the other end of the cable to the corresponding device. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the units are powered and proper connections established.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 36 www Garre t t C om com .. Fiber Cable Type cable diameter * Max. length Wavelength Multi-mode fiber 50/125, 62.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 37 www Garre t t C om com .. 5. The LINK LED corresponding to the fiber port on the front of the product will illuminate (for standard non-Link-Pass- thr ough models ) when a proper connection has been established at both ends (and when power is ON in the units at each end).
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 38 www Garre t t C om com .. The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide gui dance to network designers and installers.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 39 www Garre t t C om com .. 4.0 OPERATION This section describes the operati on of the Magnum FT14 and FT14H, 10Mb Media Converters, including power supply re quirements, up-link switch functionality, and a description of all LEDs.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 40 www Garre t t C om c om .. The FT14H Hardened media converters are designed to provide reliable operation, withstand higher temperature environments, a nd provide the direct DC power choices to the user to deploy in uncontro lled temperature environments.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 41 www Garre t t C om c om .. Note: When connected to a -48 V centralized dc source these products are to be installed only in Restricted Access Areas ( dedicated equipment rooms, electrical closets or the like).
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 42 www Garre t t C om com .. is also present and optionally can be used with an external AC power supply. DC Power Terminals : “+”, “-”, floating GND : Terminal for “earth” or ground wire connection to the FT14H chassis Input Voltage : 7.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 43 www Garre t t C om c om .. 0.2 amp max.(-48V DC) Power Consumpti on : 1.5 watts typical, 2 watts maxm.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 44 www Garre t t C om com .. terminals are identified as positive (+) and ne gative (-), and they are floating inside the unit so that either of the terminal may be gr ounded by the user if desired.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 45 www Garre t t C om com .. 4.4 Dual LEDs, front-panel and side -panel (Magnum FT14 and FT14H) LED Description PWR/P Illuminates GREEN to indicate power applied. LINK/L (TP) Illuminates GREEN, S teady ON when both attached cable segments are operational at the other end.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 46 www Garre t t C om c om .. 4.5 Up-Link (Cross -over) Switch The FT14 and FT14H Media Converter is equipped with an Up-Link slide switch.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 47 www Garre t t C om com .. 5.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 48 www Garre t t C om com .. 5.1 Before Calling for Assistance 1. If difficulty is encountered when insta lling or operating the unit, refer back to the Installation Section of the applicable chapter of this manual.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 49 www Garre t t C om com .. 4. If the problem is isolated to a network device other than the Magnum FT14/FT14H 10 Mb/s Media Converters product, it is recommended that the problem device is replaced with a known good device.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 50 www Garre t t C om com .. 5.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 51 www Garre t t C om com .. 3. It is useful to include other networ k equipment models and related hardware, including personal computers, workstati ons, terminals and pr inters; plus, the various network media ty pes being used.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 52 www Garre t t C om com .. Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure sy mptoms, including a full description of the problem.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 53 www Garre t t C om com .. GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of produc t that is not under warranty will result in a customer (user) charge.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 54 www Garre t t C om com .. 5.4 Shipping and Packaging Infor mati o n Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 55 www Garre t t C om com .. 4. Ship the package to: GarrettCom, I nc. 47823 Westinghouse Dr. Fremont, CA 94539 Attn.: Customer Service APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc.
FT14 and FT14H 10Mb Media Converters In stallation and User Guide (09/04) 56 www Garre t t C om com .. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GarrettCom FT14 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GarrettCom FT14 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GarrettCom FT14, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GarrettCom FT14 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GarrettCom FT14, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GarrettCom FT14.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GarrettCom FT14. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GarrettCom FT14 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.