Aller à la page of 27
INVERTER MULTI AIR CONDITIONER CONTENTS SPECIFICATIONS ..................... 1 OUTLINE AND DIMENSIONS ........... 3 REFRIGERANT SYSTEM DIAGRAM ..... 5 ERROR CONTENTS .................. 1 5 CIRCUIT DIAGRAM ................... 6 INDOOR PCB CIRCUIT DIAGRAM .
1 - 230 / (208) V 60Hz High Power source of specification : 230V DISCRIMINA TION Middle Low Quiet Hx WxD 10-13/16 x 31-1/8 x 8-7/16 inch (275 x 790 x 215 mm) F AN MOT OR MEASUREMENTS Net / Gross 18 lbs. / 23 lbs. (8.5 kg / 10.5 kg) MFD-34ROM 1,200 / 1,200 r .
SPECIFICATIONS (OUTDOOR UNIT) 2 2006.04.25 T otal Pipe Length ADDITIONAL CHARGE MODEL NAME POWER SUPPLY FREQUENCY NOISE LEVEL AIR CIRCULATION - High ELECTRICAL DA T A MEASUREMENT COMPRESSOR F AN MOTOR.
3 2006.04.25 SPECIFICA TIONS (COMBINA TION) MW12Y3FM x 2 + MW09Y3FM MW09Y3FM x 3 MW12Y3FM + MW09Y3FM x 2 Rated COMBINA TION 8.1 kW 27,600 BTU/h 9.7 kW 33,000 BTU/h ELECTRICAL DA T A ( 230 V ) COOLING CAP ACITY 9.7 kW 33,000 BTU/h HEA TING CAP ACITY Max Max Max Rated Rated Max Rated 1 1.
OUTLINE AND DIMENSIONS INDOOR UNIT Models : MW09Y3FM MW12Y3FM MW18Y3FM Unit : inch (mm) 4 2006.03.25 10-13/16 (275) 31-1/8 (790) 8-7/16 (215).
5 2006.04.25 Unit : inch (mm) OUTDOOR UNIT Model : MR36TQY3F 14-9/16 (370) 25-19/32 (650) Air Flow 35-7/16 (900) 1-9/16 (40) 1-7/32 (31) 15/32 (12) 32-7/8 (830) 13/16 (21) 11/32 (9) 15-3/4 (400) 13 (3.
REFRIGERANT SYSTEM DIAGRAM 6 2006.04.25 Outdoor unit Indoor unit A Indoor unit B Indoor unit C Indoor unit D THERMISTOR THERMISTOR (DIS.TEMP) OIL BACK CAPILLARY CAPILLARY TUBE PRESSURE SWITCH(A) PRESS.
INDOOR UNIT CIRCUIT DIAGRAM Models : MW09Y3FM MW12Y3FM MW18Y3FM 7 2006.04.25 ORANGE RED YELLO W PINK BLUE BLA CK BLA CK BLA CK BLA CK GRA Y GRA Y YELLO W BLUE WHITE BLA CK RED RED WHITE WHITE WHITE WH.
8 2006.04.25 Model : MR36TQY3F OUTDOOR UNIT BLACK RED RED RED RED RED RED RED RED GRA Y BRO WN ORANGE GREEN BLACK BLUE YELLOW RED BLACK WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE YELLOW ORANGE BL.
W4 GREEN W3 RED W2 BLACK W1 WHITE CN7 B3B-XASK CN10 B5B-XASK CN8 BS5P-SHF-1AA CN1 S 5(6-5) B-XARK CN2 53325-0510 CN5 2P-SAN CN6 2P-SCN CN12 B3B-XH CN1 1 B2B-XH 1 2 3 4 5 1 2 1 2 1 3 1 2 1 2 3 4 5 1 3 .
V A1 470V <TNR> V A2 470V <TNR> F1 3.15A - 250V W2 BLACK W1 WHITE W3 RED W4 GREEN GND TERMINAL BOARD 3N L C3 0.22 <LE> 1 1 5 7 8 4 4 3 2 1 6 10 7 5 4 1 2 2 3 2 4 3 L1 SS1 1V -13035 D1 GSIB460L -E3/45 R2 2.
11 2006.04.25 Models : MW09Y3FM MW12Y3FM MW18Y3FM 5V 5V 5V D204 SLR-325 < ORANGE> D203 SLR-325 <GREEN> D202 SLR-325 <GREEN> D201 SLR-325 <RED> 1 1 1 1 2 2 2 2 1 3 2 VCC OUT GND + I C201 GP1UM261R C202 47/ 10V R201 47 <1/4W> C201 0.
WHITE WHITE BLACK BLACK RED RED COMPRESSOR W12 W13 W305 W304 W303 2 3 1 2 3 1 B B B UL1015 AWG14 x 3 B B UL1015 AWG14 YELLOW UL1015 AWG14 BLUE UL1007 AWG24 x 4 YELLOW ORANGE RED BROWN UL1015 AWG14 RED.
CN802 B6P-VH-B WHITE DC FAN CN1 03 XA/172520 1007 L180 WHITE CT CN27 B6B-XARK-1-A RED EXPANSION VALVE-A CN50 06 XA/172520 1007 L300 WHITE EXPANSION VALVE-B CN51 06 XA/172520 1007 L300 WHITE EXPANSION .
5V TM101 TM102 B B C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N300300K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS INDOOR UNIT Models : MW09Y3FM MW12Y3FM MW18Y3FM Error contents Error display Indoor unit LED Outdoor unit temperature error Communication error Indoor unit control system error Indoor u.
OUTDOOR UNIT LEDS LED 1 LED 2 LED 3 LED 4 Communication error (indoor unit A to outdoor unit) Communication error (indoor unit B to outdoor unit) Communication error (indoor unit C to outdoor unit) Co.
DISASSEMBLY ILLUSTRATION 51 1 6 7 1 5 5 Models : MW09Y3FM MW12Y3FM MW18Y3FM 17 2006.05.12.
32 24 30 29 20 43 46 48 236 37 26 28 52 36 42 40 39 33 21 38 27 61-1 61-2 31 Models : MW09Y3FM MW12Y3FM MW18Y3FM 18 2006.04.26.
Model : MR36TQY3F 19 2006.04.26.
16 14 17 15 10 11 12 13 Model : MR36TQY3F 20 2006.04.26.
21 23 26 20 70 25 24 74 73 37 36 35 34 33 27 32 31 32 31 32 30 32 30 19 29 28 22 Model : MR36TQY3F 21 2006.04.26.
58 44 52 63 64 65 66 67 Connector : BLACK GREEN BLUE RED YELLOW WHITE Connector : RED 68 69 49 48 46 45 59 43 61 60 47 53 62 Model : MR36TQY3F 22 2006.
PARTS LIST INDOOR UNIT Ref. Ord. No MW09Y3FM MW12Y3FM MW18Y3FM Q'ty 1 AirFilter 67201200 67201200 67201200 5 Clamper (Grille) 67200936 67200936 67200936 6 FrontPanel 67201230 67201230 67201230 7 .
OUTDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MR36TQY3F Q'ty No MR36TQY3F Q'ty 1 Top Panel Sub Assy 67201640 41 Washer(Rubber) 67210118 2 Front Panel M 67201601 42 Frange Nut 6721011.
INDOOR UNIT OUTDOOR UNIT ST ANDARD ACCESSORIES Name and Shape Wall hook bracket Remote control unit Battery (penlight) Cloth tape Remote control unit holder Tpping screw (big) Tpping screw (small) Q&a.
0604G3076.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich R410A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich R410A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich R410A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich R410A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich R410A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich R410A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich R410A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich R410A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.