Manuel d'utilisation / d'entretien du produit Venice du fabricant Enviro
Aller à la page of 32
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE.
T able of Contents 2 Safety Precautions..........................................................................................3 Operating Instructions.....................................................................................4 Building Y our Fire.
3 Safety Prec autions FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” WOOD ST O VE, PLEASE CAREFULL Y READ THE FOLL OWING INFORMA TION: ● Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death.
Oper a ting Instructions FIRST START When rst installed, the chimney , rebricks and steel are cold and it usually takes sever al hours on a fairly high burn f or them to become hot and dry enough f or the sto ve to function well.
CREOSOTE - ITS FORMATION AND REMOVAL: When wood is burned slowly , it may produce tar and other vapors that, combined wi th moisture, form creosote. These vapors condense in the relatively cooler chimney ue of a slow burning re and, if ignited, make an extremely hot re.
6 Oper a ting Instructions d) Regulate the heat output of the stove by adjusting the air controls to allow a larger re and vice versa. A short period of experimentation with the control settings will allow you to regulate the heat output to keep your home comf ortable.
7 Oper a ting Instructions g) Once the kindling has started to burn, add some smaller pieces of seasoned, dry rewood. Note: Adding large pieces at the early stages will only serve to smother the re. Continue adding small pieces of seasoned dry rewood, keeping the door slightly open until each piece starts to ignite.
8 Oper a ting Instructions 7. What is draft? Draft is the ability of the chimney to exhaust or dr aw smoke produced during the normal combustion process. T oo much draft may cause excessive temperatures in the appliance and may damage the appliance. Inadequate draft may cause backpufng or “plugging” of the chimney .
9 Oper a ting Instructions H OW I T W ORKS : Exhaust Smoke 1 / 2 " Ceramic baffle; reflects heat down to burn the particles in the smoke. Secondary air tubes; creates a second burn on the particles in the smoke for a more efficient & cleaner burn.
S PECIFICATIONS : Table 1: 1200-V & 1700-V General Information. Model 1200 Insert 1700 Insert Width x Depth 27” x 21” (705 mm x 546 mm) 27” x 26” (705 mm x 660 mm) Height of body 19 1 / 16 ” (484 mm) or 19 9 / 16 ” (497 mm) Fire box size (depth x width x height) 16.
11 Specific a tions C LEARANCES T O C OMBUSTIBLES - 1200-V I NSERT : A Minimum clearance to an unshielded side w all 10” (254 mm) B Minimum clearance to an unshielded 8” (203 mm) mantel 21” (533.
12 Specific a tions C LEARANCES T O C OMBUSTIBLES - 1700-V I NSERT : A Minimum clearance to an unshielded side w all 10” (254 mm) B Minimum clear ance to an unshielded 8” (203 mm) mantel 24” (61.
13 Specific a tions D IMENSIONS - 1200-V I NSERT : 34 13 / 16 " (885mm) 19 1 / 16 " (484mm) or 19 9 / 16 " (497mm) 22 5 / 16 " (566mm) 26 15 / 16 " (684mm) 20 7 / 8 " (53.
Specific a tions D IMENSIONS - 1700-V I NSERT : 34 13 / 16 " (885mm) 19 1 / 16 " (484mm) or 19 9 / 16 " (497mm) 22 5 / 16 " (566mm) 26 15 / 16 " (684mm) 20 7 / 8 " (530mm.
Inst alla tion Please read and understand these instructions before installing pedestal or ash pan and leg option. F ailure to follow these instructions carefully could cause personal injury or property damage. All screws are pre-installed on the base of the unit.
Inst alla tion M ASONRY F IREPLACE I NSTALLATION : Unless you are experienced, we recommend installation by your dealer or a professional installer. Install only in a masonry replace with a good-condition chimney at least 15 ft (4 .6 m) high, both of which ha ve been constructed in accordance with the building code.
17 The ue collar is removable for installations into replaces with low openings . a) Remov e the rear two (2) secondary air tube and C-Cast Cer amic Bafes, if installed (see C-C AST C ERAMIC B AFFLE I NSTALLATION ) .
Inst alla tion Leveling Legs Figure 14: Removable ue collar in place. Figure 15: Leveling legs. S URROUND P ANEL S EALED I NSTALLATION F OR USA O NLY : Note: Though this is an allowable installation, we do not r ecommend it because of the possibilit y of poor draft, and theref ore poor stov e performance.
19 Inst alla tion I NSTALLATION U SING A B LOCK -O FF P LATE F OR USA O NLY : If this unit is to be instal led into a masonry replace or a zero-clear ance replace with a direct connection you must install a non-combustible seal-off device such as a block -off plate or damper adapter .
Inst alla tion 5. Mount the block -off plate using masonry scr ews in a masonry replace and sheet metal screws on a zero- clearance replace (screws need only be long enough to penetrate the rst layer of metal). 6. Insulate the block -off plate using high - temperature berglass insulation and furnace cement.
21 Inst alla tion M ODEL 1200-V B RICK P LACEMENT & T UBE L OCATIONS : COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. When replacing bricks, use only pumas type re bricks. TOTAL BRICKS: 12 - Full size bricks 9” long x 4 .
22 Inst alla tion M ODEL 1700-V B RICK P LACEMENT & T UBE L OCATIONS : COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. When replacing bricks, use only pumas type re bricks. TOTAL BRICKS: 16 - Full size bricks 9” long x 4 .
23 C-C AST C ERAMIC B AFFLE I NSTALLATION : 1. Slide the right C -Cast Ceramic Bafe in o ver the secondary air tubes at the top of the rebox. The tab must be on the top and pointing towards the center and the smooth side is to f ace down. Left Ceramic Baffle Right Ceramic Baffle Figure 23: Installation of C-Cast Ceramic Bafe.
24 Fan White Black Black Black Fan temperature sensor Black Fan controller Power Supply Black Black Rocker Switch Manual Auto Off Black Inst alla tion Figure 24: Fireplace Insert Fan Kit Wiring Diagram. The Insert comes with the fan assembled installed in the left shroud.
Inst alla tion R EMOVAL O F F ACE : 1. Remove the cast top from the unit (lift up and forwar d) 2. Lift up and forward on the unit f ace, the entire face and surround panel will come away f rom the unit. Figure 26: Removal of Face. 25 Figure 27: Installation of Panel.
R a ting L abel 26 **Alcove (Use double wall pipe) / Alcôve (Utilisant le double connecteur de mur) I Total width / Largeur totale 55” (1397 mm) Model/Modèle 1200 J Total height / Hauteur totale 7.
P ar ts List Reference # Description Part # 1 120F (49C) Ceramic F an T emperature Sensor EC -001 2 Insert Burner Switch EC -026 3 FPI F an Controller 115V EC -039 4 Domestic Power Cor d 115V EC -042 .
28 P ar ts Diagr am 10 11 13 12 4 25 5 3 2 1 17 7 18 23 21 29 26 22 6 32 33 16 31 34 28 30 27 8 19 20 9 9 ITEM NO. Part # DESCRIPTION 2. 1200-V Options & Parts/QTY.
29 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do.
W arr anty 6. If the problem is not covered by the Limited Warr anty , the customer will be responsible for all repair costs, as well as all storage, shipping and the cost of remo ving and re-installing the stov e. If you are not satised with the service provided by the Enviro dealer , write to Sherwood Industries Ltd.
31 W arr anty negligence, misuse, improper installation, alter ation or adjustment of the manuf acturer’ s settings of components, lack of proper and regular maintenance, alter ation, or act of God. 14. The Limited Warr anty does not cover damage caused to the stove while in tr ansit.
32 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Enviro Venice c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Enviro Venice - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Enviro Venice, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Enviro Venice va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Enviro Venice, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Enviro Venice.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Enviro Venice. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Enviro Venice ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.