Manuel d'utilisation / d'entretien du produit EG40-071 du fabricant Enviro
Aller à la page of 23
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE .
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLOWING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Caref ully r ead all the instructions in this manual rst.
T able of Contents 3 Safety Precautions..........................................................................................2 T able of Contents...........................................................................................3 Codes And Approv als.
BV: This V ented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be v ented through a conv entional chimney using a chimney liner kit. This appliance has been tested and approved f or installations from 0 feet to 2000 feet (610 m) above sea level.
5 WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENTING : This model must have a v ent opening in the rear of the unit. Conrm this and also check that the label on the right side panel door states “V ented Room Heater” . WARNING: This appliance has been designed to operate by dr awing combustion air and dilution air from the room.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y T ERMINATION : 7 .
8 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y S TRAIGHT V ERTICAL I NSTALLATION : Figure 5: Straight vertical installation. This basic venting conguration shown ar e rough guidelines only . Follow national and local codes for other installation options.
9 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : The ENVIRO EG40 will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to operate the main burners.
A DJUSTING T HE V ENTURIES : • There is a separate v enturies for each burner , see Figure 9. • R emove one screw from the cov er plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
11 Initial Inst alla tion F UEL C ONVERSION : WARNING: This conversion kit shall be installed by a qualied service technician in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work wi th gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting.
13 Second ar y Inst alla tion I NSTALLATION OF L OG S ET AND E MBERS : CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other foreign materials on the burners may create dangerous conditions.
Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. 4. Upon the rst light up, watch for ignition to ALL burner ports. If a long delay is noted: First, w ait for the appliance to cool down. • Open the front door of the appliance.
Oper a ting Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OR LIFE. A) This appliance is equipped with a pilot that must be lit by hand by following these instructions exactly .
16 R outine Maintenance and Ser vice Annually check to ensure that your V enting system is clear . Periodically check the pilot and burner . Check to see that all the burner ports are clean and clear . Check the pilot head for blockage. Check to ensure the pilot ame is blue with no or very small yellow tips.
T rouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor . • Check connections to ignitor . • If ignitor connections are good but there is no spark; replace ignitor .
P ar ts List Reference Number Part Description Part Number 1 120 °F (49 °C) Ceramic T emperature Sensor EC-001 2 220 °F (104 °C) Ceramic Spill Switch EC-002 3 S.
19 P ar ts List Reference Number Part Description Part Number BV Owner ’s Manual EG40-071 14 Pedestal EG40-080 15 Side Panel EG40-086 16 BV Stove T op EG40-087 Firebox Bafe EG40-088 Stove T op Ba.
P ar ts Diagr am - Chas sis EG 40 Body (Chassis) July 2004 20.
21 P ar ts Diagr am - Gas T r a y & Door EG40 Gas Tray & Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4.
W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arrant y on this gas product. This limited lifetime warr anty covers the appliance for a period of seven years from the date of installation.
23 Inst alla tion Da t a Sheet The following information must be r ecorded by the installer for warr anty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRES.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Enviro EG40-071 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Enviro EG40-071 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Enviro EG40-071, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Enviro EG40-071 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Enviro EG40-071, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Enviro EG40-071.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Enviro EG40-071. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Enviro EG40-071 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.