PELLET ST OVE Mini PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area.
2 Introduction................................................................................................................ ...................3 Rating Label Location..................................................................................
3 Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * R ATING L ABEL L OCATION : The rating label is located on the back of the unit. S AFETY W ARNINGS A ND R ECOMMENDATIONS : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove.
4 Introduction SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger , the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient.
5 Introduction INSTALLATION: Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area. All local regulations, including those referring to national and Eur opean Standards need to be complied with when installing this appliance.
Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Remo ve the right and left hand cabinet sides by loosening the three (3) T -20 T orx screws on the back of the each panel. 2. Remo ve the screw located on the front of the cabinet side, below the louvers and loosen the screw behind the ash door .
7 Inst alla tion A PPLIANCE D IMENSIONS AND S PECIFICATIONS : Figure 2: Dimensions of Mini. 15 1 / 2 " (393 mm) 18 7 / 8 " (481 mm) 17 1 / 2 " (444 mm) 19 5 / 8 " (497 mm) 17 7 / 8.
Inst alla tion C LEARANCES TO C OMBUSTIBLES : IMPORTANT: Attach the Mini’ s Hearth P ad when installing the unit on a combustible floor . The supplied hearth pad meet all the r equirement of a proper hearth pad. If y ou do not use the supplied hearth pad a hearth pad must be used when on combustible material.
9 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elevation.
E XHAUST AND I NTAKE L OCATIONS : 10 1 / 16 " (255mm) 6 1 / 8 " (156mm) 2 1 / 16 " (53mm) Figure 8: Mini Inlet and Outlet Location. EXHAUST Base of unit to center of flue 10 1 / 16 ” (255 mm) Center of unit to center of flue 0” (0 mm) [at center of unit] FRESH AIR INTAKE.
11 Figure 10: Corner Installation. C ORNER T HROUGH W ALL I NSTALLATION : 3" (75mm) 3" (75mm) W all thimble manufactured by pellet vent manufacturer .
Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor , or ceiling.
13 Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble 90° elbow Concrete Wall Clean out tee Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble Clean out tee 90° elbow Wall strap Figure 13: V enting horizontally with rise.
.
15 Inst alla tion H EARTH M OUNT I NSTALLATION : Rain cap Storm collar Seal plate (cover plate) Existing masonry flue V ent pipe (single wall stainless flex pipe or solid PL vent) Fireplace damper loc.
Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER (20-070): The Mini can be equipped with an externally mounted exhaust blower . This optional kit includes al l components necessary to install the exhaust blower on any vertical w all surface. 1. Remove the left hand cabinet side by removing the two (2) screws down the front.
17 Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable 90° Elbow 45°Elbow with Rodent screen or stainless steel terminatio.
Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall installations.
19 Inst alla tion T HERMOSTAT I NSTALLATION : 1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area. 2. Install a 12 or 24 V olt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.
If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly , decreasing the air in the firebox.
21 Inst alla tion O PTIONAL P ANEL K IT : This kit must be installed before the unit is started. Figure 32: Screws at back of the cab side. Figure 30: Screws above door top corner .
Inst alla tion 1 2 3 Figure 33: Installing Hopper Lid. Installing Hopper Lid: 1. Attach the hopper brackets to the back of the unit with a screw in each top holes of the brackets (#1 in Figure 33). Do not tighten these screws until all six (6) screws are in place.
23 T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication.
T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if stov e now oper ates properly , the unit may require cleaning or a new sensor .
25 T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verify that the blower turns on; if , not contact your local dealer for service.
W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey .
27 P ar ts List Reference Number Description Part Number 1 120°F (49°C) Ceramic F an T emperature Sensor EC -001 2 Auger Motor - 115V EF-001 3 High Limit T emp Sensor 200°F (93°C) Manual Reset EF-.
P ar ts List Reference Number Description Part Number 17 Burn Pot 50-1166 18 Burn Pot Liner 50-1167 19 Burn Pot Bottom 50-1168 20 Front Louvers 50-1169 21 Lid Set 50-1171 22 Stove T op Assembly 50-117.
29 P ar ts Diagr am - Components Mini - Components November 2006 .
P ar ts Diagr am - Steel Mini - Steel Components November 2006 .
31 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do.
W arr anty Exclusions and Limitations: 1. This W arranty does not cov er tarnish, discoloration or wear on the plating or paint. 2. This W arranty excludes wear and tear or br eakage caused by cleaning, moving or service on log set. 3. A qualified installer must install this stove or fireplace.
33 W arr anty 17 . Damage to plated surfaces caused by fingerprints, scr atches, melted items, or other external scores and residues left on the plated surfaces fr om the use of abrasive cleaners or polishes is not cov ered in this warr anty . 18. The Limited W arranty does not co ver tarnish, discoloration or wear on the plated surf aces.
34 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Enviro C-11150 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Enviro C-11150 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Enviro C-11150, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Enviro C-11150 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Enviro C-11150, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Enviro C-11150.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Enviro C-11150. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Enviro C-11150 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.